Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.9 L+₹24,535 (0.50%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹49.1 L+₹49,535.50 (1.02%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹50.1 L+₹1.5 L (3.09%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹50.7 L+₹2.1 L (4.26%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹65,000
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN 913862 c/o 56 APO
GER-76/2020-21Spl repair to bldg No T50 OR living T29 T38 T50 OR toilet and provn of air conditioners under AOR of AGE BR Dett B
2021_MES_422520_1
GER-76/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹65,000
Yes
25 Mar 2021
16 Feb 2021
24 Mar 2021
16 Feb 2021
22 Mar 2021
8 Mar 2021
60 days
Amount
Sch 'A' Part-I B/R Works Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Dismantling timber scantling 40 Sq cm and over in section, in any position (framed work) complete all as specified and directed.
Dismantling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
Rolled mild steel joist, channel, angle, flat iron or Tee section, fixed independently, without connecting plates etc (cut to ordinary length ie within 20mm of the length indicated) conforming to Fe 290 grade E-165 complete all as specified and directed.
0.63 mm galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' or 'J' type hooks or cranked hook bolts and washers in roofs, walls etc with grade of zinc coating 275 gm/sqm complete all as specified and directed.
0.80 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of Zinc coating 275 gm/sqm complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Walling of random rubble masonry (except stone), uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Racking out joints/pointing to block in course masonry or concrete block walling builing in cement mortar or cement lime mortar complete all as specified and directed.
Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM 1:4 complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 20mm thick on stone masonry or other than fair faces of brick wall in CM 1:6, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20mm thick on stone masonry or other than fair faces of brick wall in CM 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
Machine cut Kota stone slab flooring 18.20 mm thick as in flooring area of each slab not less than 0.30 sq.m, (cut to size in square shape) laid over & including 20 mm thick cement mortar (1:3) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and grinding to achieve mirror finish complete, all as specified and directed.
Machine cut Kota stone slab flooring 18.20 mm thick as in skirting and dado, cut to size in square shape laid over & including 20 mm thick cement mortar (1:3) screed and jointed with grey cement slurry mixed with matching shade pigment including rubbing and grinding to achieve mirror finish complete, all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4.00 Sqm each and removing to store complete all as specified and directed.
Pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
Factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
4mm thick sheet glass ordinary quality and glazing with oil putty/wooden beads in square in any size complete all as specified and directed.
Aluminium anodized barrel tower bolts 150 mm long of extruded section all as specified and directed.
Extruded aluminium alloy handles size 125 mm fabricated type anodised complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 300mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
140mm floor door stopper of brass body and tongue with hard drawn steel spring, fixed in floor complete all as specified and directed.
Preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of new steel surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
50mm thick PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled with mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand(all by weight) complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjustacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions inlcuding dismantling of exisiting board and cover fillets complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Brick work using old size bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4), complete all as specified and directed.
Vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (Ist quality) Square/rectangular, area of each tile exceeding 0.11sqm but n.exc 0.18 sqm in floors, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Glazed ceramic coloured tiles of size 350x 250x7mm or 450x350x7mm thick as on vertical surface of wall such as skirting, dado, riser etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and as directed.
Factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
75mm thick PCC 1:5:10, type E-2 using 40mm graded stone aggregates as in sub base of floors complete all as specified and directed.
Pre-polished chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 15 mm thick cement screed bed in CM 1:6 complete all as specified and as directed.
PCC type B-1 (1:3:6), using 20 mm graded stone aggregates in surface channels and drains complete all as specified and directed.
Extra for forming fair finish to drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds etc complete all as specified and directed.
Steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161 (1979) grade ST-240 complete all as specified and directed.
Viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern and flush pipe) and inlcuding set of CP jet with PVC pipe of superior quality complete all as specified and directed.
Supply only PVC low level flushing cistern 10 ltrs capacity white with inlet ball valve, float valve and handle including providing & fixing MS angle iron brackets, PVC flush pipe complete all as specified and as directed.
Vitreous China wash basin, oval shape white, flat back, size 550x 400mm including 15mm bore pillar tap cast copper alloy, PVC connection 15mm, length 450mm, low density PVC waste pipe of pressure 6kg/sqm including MS angle brackets complete all as specified and directed.
PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete as in repair all as specified and directed.
32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete as in repair all as specified and directed.
PVC waste pipe 32mm or 40 mm dia 750mm long complete all as specified and directed.
15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete as in repair all as specified and directed.
1000 ltr capacity three layer (ISI marked) rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete as in repair all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2010 complete all as specified and directed.
Butt hinges 100mm medium weight cold rolled mild steel complete all as specified and directed.
Taking up or down GI tubing 15 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Taking up or down GI tubing 20 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Angle valve fancy type, chromium plated, cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed with suitable for 15mm bore complete as in repair all as specified and directed.
Gun metal/glove valve with iron wheel head screwed on both sides for iron pipes of 20mm internal dia complete as in repair all as specified and directed.
PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints , laid in trenches or in floor, of bore 110 mm complete all as specified and directed.
PVC (SWR) pipes type 'B' single socketed in any length with rubber ring joints , laid in trenches or in floor, of bore 110 mm complete all as specified and directed.
PVC SWR bends of 110 mm bore complete all as specifed and directed.
PVC (SWR) reducer or reducing tee of size of 110 mm bore complete all as specifed and directed.
PVC (SWR) vent cowl of size of 75 mm bore complete all as specifed and directed.
PVC (SWR) WC connector with lip ring of size of 110 mm bore complete all as specifed and directed.
PVC (SWR) floor trap of size 75mm bore, plain with grating including jointing with solvent cement complete all as specified and directed.
25mm thick PCC type B0 1:2:4 (using 12.5mm graded aggregate) as in sub floor, finished even & fair complete all as specified and directed.
White Marble 20mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 15mm screed bed in CM 1:6 complete all as specified and directed.
Rendering 15mm thick in CM 1:6 on other than fair faces of brick work, surface finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5mm thick in CM 1:4 over/soffit of chajja finished surface even and smooth without using extra cement complete all as specified and directed.
Dismantling AC sheets corrugated in roof coverings includings ridges complete all as specified and directed.
Complete removal of existing treatment from old decorated surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specifed and directed.
Complete removal of existing treatment from old decorated surfaces of walls and applying two coats of cement base paint over and including a coat of cement primer complete all as specifed and directed.
Preparation of old steel surface and applying two coats of synthetic enamel paint any tint including preparation of surface complete all as specified and directed.
35mm thick flush shutter solid core construction with block board core and plywood face panel, commercial type on both sides complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates (Fe-410W) complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
300mm MS ordinary rat tail spring of approved make including roller and roller plate complete all as specified and directed.
Surface dressing n exc 15 cm deep in soft/loose soil including removing n exc 50m from the site complete all as specified and directed.
PCC 1:4:8 type D-2 (Using 40mm graded stone agg) as in foundation complete all as specified and directed.
Reinforced Cement concrete type B1, 1:2:4 ( using 20 mm graded stone agg.) in foundation inlcuding rafts, fotings, foundation beams, plinth beams, base for columns etc basement slab under reamed piles and mass concrete complete all as specified and as directed.
Reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in column, pillars, piers, struts etc complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1 (using 20mm graded aggregates) as in chajjas and similar works complete all as specified and directed.
Reinforced cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, columns , roof, landings, shelves and the like complete all as specified and directed .
Use & waste of formwork to sides of concrete foundation, footing, bases of colums, raft & raft beams, sides and soffits(if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, column etc for rought finished surface of concrete complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, landings and similar work; n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete complete all as specified and directed.
Formwork to chhajjas for flat, fair finished surfaces complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 5mm to 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Spreading, levelling, watering and well ramming the earth filliong under floor not exc 25 CM thick in layers complete all as specified and directed.
Hard core of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work, surface finished even and smooth without using extra cement including mixing of water proofing compound as per manufracturer's instructions complete all as specified directed.
Supply only integral water proofing compound complete all as specified and directed.
Rendering 10 mm thick in CM 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces on ceiling and applying three coats of white wash complete all as specified and directed.
Steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
Anodised aluminium frame for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
5.5mm thick sheet glass, ordinary quality fixed to aluminium doors in square exc 0.5 sq. m in each pane complete all as specified and directed.
75mm thick PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in sub base complete all as specified and directed.
40mm thick PCC 1:2:4, type C-1 (using 20mm graded stone aggregate as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC casing & caping complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 116 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 116 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 116 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
Switch piano, flush type single pole, one way 16 Amp, 240 volts complete all as specified and directed.
Socket 2 in 1, 3 pin 5 amp flush type complete all as specified and directed.
Socket out let 2 in 1, multipurpose 5 & 15 Amp flush type complete all as specified & directed.
Bell push, flush type, 6 amp 240 volts complete all as specified and directed.
Door bell ding dong AC 230 volts single pole complete all as specified and directed.
LED tube light fitting complete integrated type with indoor decorative PVC extruded body of 7 watt 2 feet (white) with all accessories pre-wired and connecting electrically to ceiling rose using using PVC insulated and over all sheathed flexible copper conductor cable of size 0.75 sqmm 3 core complete all as specified and directed. Crompton Cat Part No-LCL-07-CDL or equivalent in Havells/Bajaj
Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. Make Bajaj /Usha/havells/CG
Taking down ceiling fan carefully during re-wiring work & after complete re-wirng connecting, hanging disconnect fan with connecting wire including servicing, spray painting same colour of ceiling fan complete all as specified and directed.
Exhaust fan of size 300 mm heavy duty metalic body complete with louver 1400 RPM speed 230 volts AC electrical operated 50 HZ Model No. Turbo Force SP of Havells or its equivalent of Orient/ Usha/ Bajaj/CG.
LED Tube light fitting T-5 LED, Battens type 1x 20 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F20WLED P/W or its equivalent technically and commercially in Philips/Havells/Bajaj/Crompton
Sheet metal enclosure MCB distribution board in repairs single pole & neutral 430 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .(Note-MCBs will be measured and paid for separately).
MCB SP 240 volt any rating from 5 to 32 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB SPN 240 volts 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor cable as earth continuity conductor drawn through and including PVC casing caping of size 25mm width accessories fixed on wall/floor/ceiling etc complete after taking down old unserviceable sub main wiring complete all as specified and directed. Note : One run of cable and one run of casing caping shall be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete as in repair all as specified and directed.
Supply, Laying, connecting and testing in replacement of service cable of size 6 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete after taking down old unserviceable service connection etc complete all as specified and directed.
Street light fitting LED 30 watt made up of grey powder coated pressure die cast aluminium housing having IP66 control gear and lens compartment as in repair. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-30-CDL or its commercially and technically equivalent in Bajaj/Philips/Havells/C&S Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
GI bracket pipe of size 25mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket shall be fixed on wall/pole surfaces by providing suitable MS iron 25x4 mm clams 2 Nos of 25 cm long duly to the bracket pipe and painting to MS camps and fixing with necessary suitable nuts, bolts and washers and removing of old unserviceable item complete all as specified and directed.
XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. includig testing complete after taking down old unserviceable cable etc all as specified and directed.
GI pipe 40mm bore light grade (ISI marked) with all fitting fixed to wall, poles or under road crossing etc with suitable size clamps for protection of cable complete all as specified and directed.
Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electricaly using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed. Cat part No HEXAFT10WLED857SSYMBOPC,Make-Havells or equivalent model in Bajaj, C&S
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for laying of cable and foundation of poles and stays and n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
Sand cushioning to underground cable, provided with a layer of 8 cm deep before laying the cable and 15 cm thick after laying and stretching jointing and testing the cable complete all as specified and as directed Note: Punned thickness of sand shall be measured and paid.
Supplying and laying reinforced precast concrete cable cover, class LV, type 1 flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 18 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete as in repair all as specified & as directed by Engr in Charge. Make Crompton Cat Part No-LCTL-18-CDL or its equivalent technically and commercially in Philips/Havells/Bajaj/C&S
LED street light fitting 40 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lense with IP 65 complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and removing old unserviceable item complete as in repair all as specified and directed Make - Crompton model No FREEDOM+LSTS-40-CDL LED or equivalent model in Bajaj/Havells/C&S
Sheet metal enclosure MCB distribution board in repairs single pole & neutral 430 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .(Note-MCBs will be measured and paid for separately).
XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. includig testing complete after taking old unserviceable cable etc complete all as specified and directed.
GI pipe 50mm bore light grade (ISI marked) with all fitting fixed to wall, poles or under road crossing etc with suitable size clamps for protection of cable complete all as specified and directed.
Cutting, threading and inserting tee for taking new branch connection from existing pipe line of any size for the pipe size 40mm including necessary GI fittings ISI marked complete all as specified and directed.
XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm 3.5 core laid in trenches/ on poles/ under road crossing etc. includig testing complete all as specified and directed.
Supply , install, testing and commissioning of factory made outdoor type floor mounted LT panel board cubicle type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved copper bus bar of rating 300 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-55 class protection and made out of 3.15 mm CRCA sheet and 50 X 50 X 6 mm thick MS angle iron frame work front and rear side opening with adequate size for housing LT switch gear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm. The size of panel shall be 450x1800x1500mm, minimum clearance from ground level should be 450mm and comprising of followings components:- (a) MCCB 250 Amp 4 Pole, 35KA, 415 V, 50 HZ - 01 No (b) MCCB 100 Amp 4 Pole, 16KA, 415 V, 50 HZ - 03 Nos (c) MCCB 63 Amp 4 Pole, 10KA, 415 V, 50 HZ - 02 Nos (d) Digital voltmeter with VSS -01 set (e) Digital ammeter with CTs and ASS - 01 Set (f) LED indicators lamps-01 set (h) Aluminium bus bar TPN 400 Amp rating . Notes : (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 Nos legs of 50mm x 50mmx6mm for fixing the panel (ii) MCCB shall be fixed in suitable sheet metal enclouser made up of 2mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement
Supply, installation and testing of air cooled split unit air conditioner electric driven (single phase), copper kit for cooling and heating type of capacity 4500 K cal per hour 1.5 Ton, 3/5 star rating with remote control, wall mounted with suitable arrangement including all piping etc. complete all as specified and directed. Make :- LG/Voltas/Blue star/Samsung.
Supply, install, commissioning and testing vertical storage water heater (geyser) 5 star rated as per BEE norms electricity operated suitable for 230 volts, 50 hz, AC supply system complete with porcelen/ glass coated insulated heating element, copper tank, external thermostat and docorative of capacity 25 Ltrs, including 01 No. CP connection for hot water and 01 No PVC connection for cold water including fixing on suitable bolts and nuts complete all as specified and directed.
Bib tap cast copper alloy with crutch or butterfly handle, screwed for iron pipe, suitable for 15 mm bore complete all as specified and directed.
Lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 15 watt complete all as specified and directed.
Supply, Laying, connecting and testing in replacement of service cable of size 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular complete after taking old unserviceable service connection etc complete all as specified and directed.
House service bracket (hook type complete with 3.0m long G.I. pipe 40mm dia Med. grade, two nos900 bends. M.S. hook and stay or guy complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S MINTA & CO
VIJAY KUMAR SURI AND SONS
SATVIR GUPTA ENGINEER and CONTRACTOR
M/S Jyoti Parkash Tilak Raj Gupta
M/S RAHUL GUPTA
M/s Parvesh Gupta
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .