Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance C 36 DUGGAL COLONY KHANPUR DEVLI ROAD DELHI 110062 | SOUTH | DELHI | 110062 | Admitted-Finance |
| 2 | Admitted-Finance 1ST FLOOR B 3 111 9 YASHIKA APARTMENT KISHAN GARH VASANT KUNJ NEW DELHI 110070 | NEW DELHI | DELHI | 110070 | Admitted-Finance |
| 3 | Admitted-Finance F 2 87 88 ROHINI NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance SHAHDARA | DELHI | 110095 | Admitted-Finance |
Tender Value
₹16.1 L
EMD Value
₹16,100
Closing Date
20 Dec 2021, 2:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Secretary, APMC, Azadpur
EE (E) APMC, Azadpur
Re electrification of the road crossing including supply and fixing of main panels, distribution boards at F and V and Onion Mkt Okhla
2021_DAMB_212615_1
APMC/ED(E)/Ohla
Open Tender
Electrical Works
Works
90 days
APMC, Okhla
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹16,100
31 Dec 2021
10 Dec 2021
20 Dec 2021
10 Dec 2021
20 Dec 2021
10 Dec 2021
90 days
Amount
S/I/T/C of L T feeder pillar weather proof out door type of size 1500 x 1000 x 600 mm deep with 300 amp capacity 4 strip Aluminum Bus Bar dully fabricated with 2 mm thick (load bearing members) and 1.6 mm thick (non load bearing members) front door covers with locking arrangement CRCA sheet with detachable glands plate with knockouts equal to members of MCCB, suitable iron choki, strength channels, solid connections with color coded al bus strips cable alley and channel ms stand as per site requirement with powder coated i/c providing and fixing all accessories with connections etc as required . The feeder piller shall be comprise following accessories. (Onion Shed & Office) ) 125 amp DH MCCB 4P 36 KA :- 1 No. ii) 63 amps. ratings, DP MCB, “C” curve, 10 KA breaking capacity:- 12 Nos.
S/I/T/C of Main panel size 1000x 1000x 300 mm deep and 16 SWG CRCA sheet with primer powder cost material i/c suitable iron choki, nut bolts, clamps as per site requirment. (Onion Shed & Office) i) 250 amp DH MCCB 4P 50 KA :- 1 Nos. ii) 125 amp DH MCCB 4P 36 KA :- 4 Nos.
Supply & Fixing of outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals Havells
Supply of 4 x 16 sq. mm (Armoured ) size PVC insulated PVC sheathed aluminum conductor cable of 1.1 KV Grade.
Supply of 4 x 25 sq. mm (Armoured ) size PVC insulated PVC sheathed aluminum conductor cable of 1.1 KV Grade.
Supply of 4 x 35 sq. mm (Armoured ) size PVC insulated PVC sheathed aluminum conductor cable of 1.1 KV Grade.
Supply of 4 x 50 sq. mm (Armoured ) size PVC insulated PVC sheathed aluminum conductor cable of 1.1 KV Grade.
Supply of 4 x 70 sq. mm (Armoured ) size PVC insulated PVC sheathed aluminum conductor cable of 1.1 KV Grade.
Supplying and fixing of surface mounting junction box of PVC material of size (230 mm out side dimension 350mm x250mmX150 mm deep single door 4 way junction box front cover side hinged type, having 2 number Alumunium bus bar fixing with suitable accesories i.c nut, bolts, washer stud and Red bus bar insulator 4 nos. of size 25mm as required . The box shall be fixed with suitable size of fastener truss / coloumn etc as reqd. Make Sintex
Supply of M.S tubular stepped and swaged type pole length of 12 mtr.with 300 mm X 300 mm X 6 mm thick M.S. plate in bottom and including primer, painting of approved color etc. as required. SP 410-66
Making of CC coller in shape of round at the bottom of M.S. pole to protect from the weather.The size of CC coller should be . 8 mtr. Height and .6 mtr. Dia and the ratio of CC should be used 1:4:8 ( 1 cement : 4 coarse sand (zone -III) : 8 graded stone aggregate 40
S/F of steel wire rope 16 mm dia (6/19 construction )from cross arm to cross arm existing top of poles with 3 nos of U clmaps nuts, bolts, washers at each side to bind of steel wire rope etc as required
S/I/T/C of Main panel size 1000x 1000x 300 mm deep and 16 SWG CRCA sheet with primer powder cost material i/c suitable iron choki, nut bolts, clamps as per site requirment. (F &V Market Okhla) 6300 amp DH MCCB 4P 50 KA :- 1 Nos.
Erection of metallic pole above 10.00 meter and upto 12.00 meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Dismantling of pole/ street light standard/ strut embedded in brick ballast fundations etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required .
4 X 16 sq. mm (28mm)
4 X 25 sq. mm (28mm)
4 X 35 sq. mm (32mm)
4 X 50 sq. mm (35mm)
4 X 70 sq. mm (38mm)
Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket,bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
90 mm dia (OD-90 mm & ID-76 mm nominal )
120 mm dia (OD-120 mm & ID-103 mm nominal )
Supplying of channel iron 75 mm X 40 mm 6 mm ( 7.14 kg per meter) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing ) and painting with primer and finished paint as required
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm), G.I bolts, nuts and washers, coach screws etc. as required.
Dismantling of over head lines comprising of copper/ aluminium over head conductor/aluminium Cabels , G.I. wire, cross arms, insulators etc. as required. (Varies Size)
Buy back Rate of dismantled old panels and scrap material
Buy back Rate of dismantled old Cabels.
M/S MASTER ELECTRIC STORE
SM ELECTROTECH PRIVATE LIMITED
BHARDWAJ BROTHERS
RAMESH ELECTRIC WORKS
SRS ENGINEERS
ANU ENGINEERING CORPORATION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .