Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC 39 MAHESHMATI BANK COLONI MALDA WEST BENGAL | MALDA | MALDA | WEST BENGAL | 732101 | L1 | Accepted-AOC Amount
quoted stood
lowest | |
| 2 | L2₹3.9 L+₹10,002 (2.60%)Rejected-Finance PURATULI MALDA 732101 | MALDA | MALDA | WEST BENGAL | 732101 | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹4.0 L+₹15,719 (4.09%)Rejected-Finance GROUND FLOOR 109 186 114 LAHIRI VILLA NEW BANSBARI MALDA WEST BENGAL 732102 | MALDA | MALDA | WEST BENGAL | 732102 | L3 | Rejected-Finance Higher Bid |
Tender Value
Refer Docs
EMD Value
₹7,712
Closing Date
25 Mar 2023, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
O/o AE/MESD-I PWD,
O/o AE/MESD-I PWD,
Campus lighting as per boundary basis with renovation work at Electrical Lab at ITI Habibpur -- Additional Work
2023_WBPWD_495829_1
WBPWD/AE/MESD-I/e-NIQ-28/22-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
MALDA
Please refer Tender Documents
5 documents required · 5 mandatory
₹7,712
Yes
4 Apr 2023
20 Mar 2023
28 Mar 2023
21 Mar 2023
25 Mar 2023
22 Mar 2023
Amount
S&F of 2 ton capacity split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R410A/R-32 having PCB in metal enclosure on wall using angle iron frame incl. charging the refregerent as per direction of EIC. (Make-O-General or equivalent model of Mitsubishi Heavy/Daikin/Hitachi as approve by the E.I.C.) (SRK24CW-S6/ ASGA24FUTC/ FTKL60)
S&F of 1.5 ton capacity split Air-conditioner machine fitted with Rotary compressors suitable for Refrigerant-R410A/R-32 having PCB in metal enclosure on wall using angle iron frame incl. charging the refregerent as per direction of EIC. (Make-O-General or equivalent model of Mitsubishi Electric/Daikin/Hitachi as approve by the E.I.C.) (SRK20CSS-S6/A) ASGA18FUTD/FTKL50)
Supply & Laying Extra Add-on items- 5/8"(for suction) & 3/8"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 1.5/2/2.5 TR A.C. Machine. as per direction of E.I.C.
Supply and fixing of 3 core starneded copper cable for Working Voltage up to 1100 Volts of following sizes as per direction of EIC.
3 Core 2.5 sq. mm. Communication Cable
S&F of 25mm Dia uPVC pipre for AC drain pipe on wall, ceiling with saddles and other accessories as required and mending good damages to building works
upply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand Legrand Myrius/Schneider Zencelo/C&S Electric Divino /Havells Thames as approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [ 5(a) / E-17]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug top with indicator (Brand Legrand Myrius/Schneider Zencelo/C&S Electric Divino /Havells Thames as approved by E.I.C) & necy. Connections as per GS. [ 5(b) / E-17]
Supply & Fixing 240 V, 25 A, Modular type AC starter (Brand Legrand Myrius /Schneider Zencelo/ C&S Electric Divino /Havells Thames as approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [17 / E-19]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. [ 7/E-16]
a) 20mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.
(i)2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ]
SFinishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5sqmm [9 (i)/F-5]
4 sqmm [9 (ii)/F-5]
Supply of 2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco/Havells/Fort Gloster/Kei]
2 Core 6 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 core 6 sqmm [8(b)/F-5]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 core 6 sqmm [7(a)/F-4]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as per GS. [2(a)/F-1]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core as per GS. [3(a)/F-1]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
(i)32 mm dia [11(b)/F-6]
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint as per GS. [5/H-5]
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate will have to be submitted during delifery of the material.
ARGHYA BHATTACHARYA
M/S EASTERN ENGINEERING
technical_1010413.pdf
PDF • 0.06 MB
techsummary_1010413.pdf
PDF • 0.49 MB
finance_1010413.pdf
PDF • 0.06 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1010413.pdf
PDF • 0.98 MB
AOC.pdf
PDF • 0.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .