Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹18.5 L+₹96,110.50 (5.49%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹20.4 L+₹2.9 L (16.6%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹20.7 L+₹3.2 L (18.5%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L5₹21.9 L+₹4.4 L (25.2%)Rejected-Finance BHAIRAVNATH NAGAR AT KUSGAON POST LONAVLA 410 401 DISTT PUNE | PUNE | MAHARASHTRA | 410401 | L5 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
1 Nov 2022, 6:00 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
ADDITION / ALTERNATION AND SPECIAL REPAIRS TO BLDG. NO P-259 IN SMQ AT INS SHIVAJI LONAVLA
2022_MES_557249_1
GE/LONAVLA/8100/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹48,000
Yes
10 Dec 2022
12 Oct 2022
3 Nov 2022
12 Oct 2022
1 Nov 2022
19 Oct 2022
12 Oct 2022 - 18 Oct 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M/L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.18 sqm n exc 0.36 sqm in floors/vertical surfaces etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
S&F Non Skid (coloured) ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15 mm thick screed bed in cement mortar (1:6) complete all as specifed and as directed.
S&F glazed ceramic coloured tiles (300mmx 450mmx7 mm) in vertical surfaces jointed in neat cement slurry and pointed in white cement. Incl cutting the tiles to the required size whereven required incl mitring the corners etc over 10 mm thick backing coats of cement plaster in CM (1:4) complete all as specified and directed.
Taking down existing doors/windows/ventilators (without taking off shutters and guard bars) of n exe 1.5 sqm complete all as specified and as directed incl stacking the materials properly.
Taking down existing doors/windows/ventilators (without taking off shutters and guard bars) of exe 1.5 sqm & n. exc 4 sqm etc complete all as specified and as directed incl stacking the materials properly.
Taking down Shutters of any Description exc 1Sqm but n.exc 2 Sqm Each complete all as specified
M&L for powder coated aluminium three track, three shutter (of equal width) sliding type window without sash bar including necessary jointing clip, rubber packing, neoprene rubber gasket, locking arrangement (star lock) bearing (two no's for each sliding shutter ) &4 mm thick plain glass for glazing with for two shutters and aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire stapless complete all as specified and directed for one shutter & including following powder coated section as given in 'JINDAL' catalouge complete all as specified and as directed (i) Frame (Bottom) -20620, (ii) Frame top & Side - 20621, (iii) Shutter Vertical (Handle Lock) - 20846, (iv) Shutter Vertical -(int lock) - 20845, (v) Shutter (Top) - 20844, (shutter Bottom) - 20847
S&F aluminium ventilator louvered type without sash bar section as per designation 63400 of IS 737 approved by GE( minium 15 micron anodised) including necessary jointing clip, rubber packing,including necessary locking arrangement , anodised snap beading screws and 4mm thick pin headed glass etc complete
S&F factory made Solid PVC Double door frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, supplying & Fixing in opening as directed by EIC
S&F factory made PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube all as specified and as directed.
S & F 30mm thick second class hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, with commercial face veneers complete all as specified and as directed.
S & F factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F for 35 mm Factory made Moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness,lipped with 15 mm (5mm x 3) thick x30 mm width on the other stiles & bottom rails & 10mm (5mm x 2) thick x 30 mm width on other stiles & bottom rails , The inner panel laminated with 2 mm thick termite proof, water proof and fire resistant molded PVC sheet with 2,4,6 raised panel designs in different plain and / or prelam colours after routing the Moulded design on one side & 2 mm plain and / or prelam PVC sheet on other side using rubber adhesive on flush door & solvent cement adhesive on the PVC Lipping and manufacturer's specification & drawing etc, complete all as specified and directed.
Ditto all as SI Item No 14 above but wire gauzed i.e pannel will be of wire gauze in lieu of single side prelam PVC sheet pannel. The wire gauze shall be wrapped on an addtional square 8 mm MS solid tube and and this tube shall be welded to MS tubes. The wire shall be streched to tighten firmily all as specified and directed
S&F Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165
S/F Screw eye 10 to 12 mm internal dia and fixed
M&L preparation of new/old steel surface and applying two coats of synthetic enamel paint ovre a coat of red oxide primer.
M&L for machine cut Granite (of any type) tiles 20-25mm thick for kitchen platform over and including bedded and jointed with grey cement slurry/backing coat 15 mm thick in CM (1:4) and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types
M & L for Machine cut kota stone slab flooring 20-25mm thick for window cill, jambs and sofits over and including cement screed base 20 mm thk in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M & L for Rounding to edges of stone slabs on edge, such as in steps, cooking platform, and other similar situations
S&F Butt hinges,125mm stainless steel, with stainless steel hinge pin complete.
S&F aluminium handles cast type anodised 150mm size.
S&F aluminium anodised barrel tower bolts of extruded section and fixed 200 mm size.
S&F aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of sextruded sections or cast aluminium alloy and fixed 300mm length.
M&L for preparation of new/ old wooden surfaces by applying two coats of synthetic enamel painting over one coat of pink primer on wooden surfaces exceeding 10 cm width or girth including preparation of new/old surfaces.
Disconnecting existing tanks disconnecting existing tank, setting aside (or lowering if required) for repairs, cheaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repainring, etc. measured separately) , exc 250& not exc 500 litrs tanks complete all as specified.
Dismantling of water tanks exc 500 & n exc 1000 ltr capacity and removing to store complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltrs capacity hoisted and fixed in position including 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified
Taking up or down steel tubing and connections, 15 mm bore including cleaning for re-fixing or removal to store
Taking up or down steel tubing and connections, 20 mm bore including cleaning for re-fixing or removal to store
Taking up or down steel tubing and connections, 25 mm bore including cleaning for re-fixing or removal to store
S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all fittings such as Tee, bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
Tubes, ‘medium grade’ galvanised, 25 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors
S&F in repairs brass chromium plated shower rose with or without swivel joints 75mm size, including fixing to steel pipe or union complete all as specified and as directed.
S/F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC with PVC telescopic pipe complete all as specified and directed.
S &F PVC connections 15 mm size with PTMT nuts of length 450 mm
S&F in repairs brass Chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type. Make -Jaqur,Prayag polymers Pvt Ltd or equivalent.
S & F Bib taps, fancy type chromium plated with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore
S & F Stop valves, fancy type chromium plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed 15mm bore
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm
S&F stainless steel kitchen plate rack of size 90cm X120cm X 1mm thick (18 gauge) in repair, complete all as specified and directed.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, as in floors or fixed to walls 75 mm bore
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or fixed to walls 110 mm bore
PVC (SWR) bends any radius 75 mm bore
PVC (SWR) bends any radius 110 mm bore
PVC (SWR) floor trap, plain with grating including jointing with solvent cement diameter of outlet 75 mm
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L for rendering 5 mm thick cement plaster in CM 1:3 on ceiling or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified.
M&L for preparation of new plastered surface of ceiling and applying three coat of white wash over 3mm thick wall care putty complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces and finished even and smooth without using extra cement on walls
M&L for rendering 20mm thick cement plaster in CM 1:4 (12mm as 1st coat and 8mm in finishing coat using water proofing compound @ 3% by the weight of cement on brick/ stone surfaces finished fair and even without using extra cement etc complete all as specified and directed.Note : Water proofing compound and will be measured and paid separately.
Supply only integral water proofing compound.
M&L for preparation of new plastered surface of wall and applying Two coat of oil bound distemper over the alkali resistance priming paint primer over 3mm thick wall care putty complete all as specified and as directed.
Preparing new plastered external surface of wall and applying 2 Coats of Acrylic elastomeric exterior waterproof coating (Dr. Fixit Raincoat or of equivalent make mentioned in list of manufacturers herein after) with extra coat on rain lashed walls, dead walls, projections & Parapet wall top on primed surface with Efflorescence resistant penetrating primer (Dr. Fixit Primeseal or of equivalent make mentioned in list of manufacturers herein after) diluted with 50% water. Work shall be executed by engaging the approved applicator of the manufacturer and as approved by GE.
M&L for preparation of old painted surfaces including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss; efflorescent salts & trading oil, greasy spots and applying two coat of lime white wash on the ceiling etc complete all as specified and directed (Rate inclusive of necessary scaffolding, trestels, ladders, cradles etc required for execution of work)
M&L for preparation of old plastered surface of wall and applying two coat of white wash complete all as specified and as directed.
M&L for complete removal of existing treatment of old painted wall surfaces and applying two coats of oil bound distemper over a coat of primer over 3mm thick wall care putty of approved make & shade on walls and other places as directed by Engr-in-Charge. (Rate including the required scaffolding & other accesories required for painting)
M&L for complete removal of existing treatment of old painted external surface of wall and applying 2 Coats of Acrylic elastomeric exterior waterproof coating (Dr. Fixit Raincoat or of equivalent make mentioned in list of manufacturers herein after) with extra coat on rain lashed walls, dead walls, projections & Parapet wall top on primed surface with Efflorescence resistant penetrating primer (Dr. Fixit Primeseal or of equivalent make mentioned in list of manufacturers herein after) diluted with 50% water. Work shall be executed by engaging the approved applicator of the manufacturer and as approved by GE.
M & L for Preparation of old painted steel surfaces of any description having execcding 10cm width or girth and applying two coat of synthatic enamel paint complete all as specified (Rate inclusive of necessary scaffolding and cradles for hoisting and lowering etc required for execution of work)
Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris to a distance exc. 1500m but n.exc. 2000m etc complete all as specified and directed by Engr-in-charge.
M/L for rendering 10mm thick in cm 1:4 on concrete roof and chajja surface finished even and smooth without using extra cement to get a uniform level surface for laying of membrane treatment .
M/L for PCC 1: 2 : 4 type B-1 (using 12.5mm graded agg) for PCC padding on RCC roof surface finished even and smoother using extra cement all as specified and directed by Engr-in-Charge.
M/L for applying oil based bituminous primer @ 0.10 Kg/Sqm providing and laying 4mm thick. APP modified water proofing membrane weighing not less than 4kg/sqm re-inforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 650 N/Sqm, tearing strength of 180N and with thermal insulation with the mineral / graved finish on upper side and laying with torches application and with 10 cm minimum lap in both direction length wise and width wise all as specified and directed by Engr-in-charge.
S&F 20mm dia towel rail chromium plated 60cm long including bracket fixed with stainless screws complete all as specified.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate), 75mm thick as in plinth protection, subbase of flooring etc.
M&L for 18/19mm thick pre-laminated particle boards , interior grade , prelaminated both sides with decorative choice lamination fixed to timber frame-work with screws fixed in repairs complete all as specified and directed.
M&L for second class clean sawn hardwood in scantling fixed in timber framed work for cupboardframe complete all as specified and directed.
S&F Magnetic catcher for cupboard fixed with fixing arrangement complete all as specified .
S&F 15mm dia Al plain rod with clip fixing in cupboard complete all as specified.
Dismantiling and removing sunken slab filling of brick bats/cinder/light weight concrete including plastering on sunken floor/sides of floor slab/tiles of toilets in all the floors including all the water and sanitary fixtures and removing all rubbish/debris outside MoD land as per instruction complete all as specified and directed.
The sunken floor RCC slab including sides to the full extent of sunken portion in upper floor shall be prepared and plastered with 15 mm thick cement plaster in CM 1:3 with water proofing compound as per manufacturer's instructions and finished even and smooth without using extra cement. When the plaster is cured and dried up, apply a uniform coat of blown grade bitumen 85/25 @ 1.2 kg/Sqm confirming to IS 702 over a coat of primer @ 0.70 Kg.Sqm over plastered surface complete all as specified and as directed. Note :- Integral water proofing compound shall be measured and paid separately as "Supply only".
Water proofing treatment to Sunken floor slabe complete as specified bellow and as directed. (a) Provide and lay 3mm thick APP modified torch applied prefabricated five layer water proofing membrane weight not less than 3.60 Kg/Sqm. (b) Apply a uniform coat of blown grade bitumen 85/25 @ 1.2 Kg/Sqm confirming to IS 702 of the surface area.
PCC lean concrete 1:5:10 type E2 laid in layers of not more than 100 mm thick tamping etc complete all as specified and directed by Engineer-in-Charge.
50mm thick PCC 1:2:4 type B0 as padding concrete over lean concrete.
Cutting holes into or through brick/ stone walls built in cement mortar of superficial area n exc 150 Sq.cm and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. Note: Sl Item Nos 1 to 82 is required to be carried out at height upto 15 m above GL in narrow spaces/widths.rate is deemed to be included for all necessary scaffolding, protective measures required to carried out work ay above mentioned heights
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S&F 20mm dia SS curtain rod with fancy brackets with fixing arrangement complete all as specified and directed
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. (a) One light point or one fan point or bell point controlled by one switch
(b) One 3 pin socket outlet, 5 Amp independent
(c) One 3 pin socket outlet, 5 Amp on the same board with other switches
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item No.86 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type with fuse & neon incator complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
Supply and fixing LED lights fitting Rod and Batten for 1x 18W, 220V,AC decorative type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete.Make: Bajaj(BLRB-DB 118 for Batten and BLRB 18W LED Rod,18W LED) or equivlent Philips/Havells
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make: Crompton or equivlent Bajaj/Philips/Havells
S/F switch bell push, flush type 5 Amp.
S&F in repairs bell, electronic type AC, 230 Volts single pole.
M&L lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings.
Supply and fix new adore LED lamp 9 Watt confirming to Cat No LHLDBWH4L8R009 of Havell's or euivalent in Philips / Bajaj
Supply and fix Inverter Bulb LED lamp 9 Watt confirming to Cat No LHLDEGEDML8009 of Havell's or euivalent in Philips / Bajaj
Labour only for taking down and fixing repairs to Ceiling Fan with Fan regulator/Exhaust Fan, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
S&F in repairs fan regulator electronic step type complete all as directed by EIC at site
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter ,and Refixed same Nos of meter on wooden board in metal box of suitable size in same Nos of qtr after repair works completed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Two run of 6 sqmm wire and One run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
S&F in replacement Triple pole and neutral (8 Way) Double door, (VTPN) suitable for and including MCCB 4 pole, 160 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed , Make Havells (DHDLVDOBGSFE08)HSN CODE 8537 or equivalent indoasian/Standered.
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
M & L for cutting/making hole for fixing of ser item No 15 and making good disturbed surface with existing surface all as specified and directed by Engr-in-charge.
VIJAYA ENTERPRISES
SAI SAMARTH ENTERPRISES
M/s S.D Construction Co
seema enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .