Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
28 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
CWE Lucknow
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
SPECIAL REPAIR TO JOINERY AND ROOF TREATMENT OF VARIOUS BUILDINGS UNDER AOR OF AGE B/R-II OF GE (WEST) LUCKNOW
2026_MES_775295_2
CWE/LKO/W/T-13 OF 2026-27
Open Tender
Civil Works
Item Rate
180 days
Lucknow
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE west Lucknow
₹2.2 L
Yes
14 Oct 2026
14 Oct 2026
30 Oct 2026
14 Oct 2026
28 Oct 2026
21 Oct 2026
14 Oct 2026 - 21 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for brick work with fly ash bricks, straight or curved on plan including demolition exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed. | 6.9 | Cum | - | - |
| 2 | M & L rendering/ plastering by using ready mix mixture of thickness 12mm to 15mm and plastering the wall surfaces with white cement based polymer modified self curring mortar all complete as per the direction on engr-in-charge. | 85 | Sqm | - | - |
| 3 | M&L for joint free glazed coloured GLOSSY tiles, superior quality of size 300 x 450 x 7mm thick/300 x 600 x 7mm thick, in vertical surfaces etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 and dismantling of existing tiles complete all as specified and directed. | 96 | Sqm | - | - |
| 4 | Dismantling brick tiles or terracing tiles, single layer of roofs including mud pushaka etc roughening surfaces of old concrete by picking, sweeping/Brushing clean and washing down with water to remove dust and complete all as directed. | 2,600 | Sqm | - | - |
| 5 | M&L PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs/padding /benching or mud stops, and platform for mounting service tanks, rounded,chamfered on edges including applying neat cement slurry with 3.0kg of cement per sq. metre necessary use and waste of from work etc all as specified and directed. | 130 | Cum | - | - |
| 6 | M&L for rendering/ plaster by using readymix mixture of thickness 8 mm to 10 mm on newly prepared surface and plastering the wall/ floor surface with white cement based polymer modified self curing mortar, all complete as per the direction of Engineer-in-Charge. | 2,700 | Sqm | - | - |
| 7 | M & L for cleaning of all loose dirt and dust from roof surfaces and applying roof treatment as under :-
Providing and applying fibre reinforced liquid applied elastomeric membrane made of PU PolyUrethane over epoxy based primer 16D (consumption 0.20-0.25 kg/sqm) and let dry for 4-6 hrs. Furthur apply two coats of water proofing treatment fibre reinforced liquid applied elastomeric membrane made of PU Polyurethane in a gap of 4-6 hrs. The applied material should have specific gravity of 1.25 g/cc with minimum recommended coverage of 2.3-2.5 kg/sqm in 2-3 cats to build DFT of 1.5 mm the cured membrane shall exhibit -
1. Tensile Strength ASTM D412 : 1.4 - 2.5 Mpa.
2. Elongation ASTM D412 : 400-500%
3. Adhesion Strength :>2N/Sqm as per ASTM D4541.
4. Crack Bridging Ability : >3-4 mm as per AS/NZS 4548: 5:1999
5. Water Permeability : NIL as per DIN 1048.
6. Separation layer of geo-textile membrane 100-200 gsm with overlaps of 50 mm in both directions over the 1st coat when the surface is still tacky.
Note : (A) The Contractor shall furnish a valid Memorandum of Understanding (MOU) with the manufacturer (makes are mentioned in CA) prior to execution of this items.
(B) Before carrying out roof treatment the building, the contractors shall replace the existing water tanks and their PCP tubing. | 2,700 | Sqm | - | - |
| 8 | S&F in repair PVC (SWR) pipes size 110 mm bore of rating 6kgf/cmsq in any length fixed to walls with M.S. clamp 50 x 5mm and SS screw and other necessary fitting including taking down old pipe complete all as specified and directed | 720 | RM | - | - |
| 9 | S&F in repairs PVC bends 110 mm bore of rating 6kgf/cmsq fixed to wall with M.S. clamps 50 x 5mm and SS screw and other necessary fitting including taking down old pipe complete all as specified and directed | 160 | Each | - | - |
| 10 | Taking down steel tubing of 15 mm dia (Nominal bore) and connections, including cleaning for refixing or removal to store complete all as specified and directed. | 110 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.26 MB
TenderWT13.pdf
Tender Documents • 1.73 MB
BOQ_890330.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .