| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.5 LAccepted-AOC AT BACHRA P O BACHRA DIST CHATRA JHARKHAND | ₹3.5 L Quoted ₹3.0 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹3.8 LRejected-Finance AT DAKRA P O DAKRA DISTT RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | ₹3.8 L | L-2 | Rejected-Finance L-2 |
| 3 | L-3₹3.8 LRejected-Finance PANCHSHEEL NAGAR PANDRA MEHAL RANCHI | ₹3.8 L | L-3 | Rejected-Finance L-3 |
| 4 | L-4₹5.2 LRejected-Finance HOUSE NO 345 SHREE RAM ELECTRICALS SONIPAT ROAD LAWANSPUR SONIPAT HARYANA 131021 UDYAM HR 18 0041413 | SONIPAT | HARYANA | 131021 | ₹5.2 L | L-4 | Rejected-Finance L-4 |
| 5 | L-5₹5.5 LRejected-Finance AT KDHA TYPE KALI MANDIR DAKRA KHALARI RANCHI | RANCHI | ₹5.5 L | L-5 | Rejected-Finance L-5 |
| Sl No | Description | Qty | Unit | M/S MEHTA ELECTRONICS L2 | M/s.Pooja Construction L1 | SRI RAM CONSTRUCTION L3 | SHREE RAM ELECTRICALS L4 | B.K.ELECTRICAL L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
(Location of earthing W/B no- 10- 2 no., W/B no-01- 02 no., W/B no- 11- 3 no. and 02 no in each RFID porta cabin) | 11 | No | 9,206.2 ₹1.0 L | 7,301.88 ₹80,320.68 | 8,800 ₹96,800 | 12,792 ₹1.4 L | 13,000 ₹1.4 L |
| 2.00 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) | 110 | Mtr. | 96.14 ₹10,574.96 | 76.25 ₹8,387.50 | 100 ₹11,000 | 134 ₹14,740 | 150 ₹16,500 |
| 3.00 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 130 | Mtr. | 84.32 ₹10,961.08 | 66.88 ₹8,694.40 | 88 ₹11,440 | 117 ₹15,210 | 120 ₹15,600 |
| 4.00 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A. | 14 | No. | 1,969.21 ₹27,568.97 | 1,561.88 ₹21,866.32 | 2,050 ₹28,700 | 2,736 ₹38,304 | 2,800 ₹39,200 |
| 5.00 | Supply and Fixing of Havells Surge Protection Devices 320 V DHSAARBC50320 (TP+N) with MCB BOX | 9 | Set | 12,607.21 ₹1.1 L | 9,999.38 ₹89,994.42 | 13,120 ₹1.2 L | 17,519 ₹1.6 L | 18,000 ₹1.6 L |
| 6.00 | Providing ang fixing 16 Sq mm Single Core copper Flexible Cables (Yellow/Green) for earthing connection. | 180 | Mtr. | 119.15 ₹21,446.21 | 94.5 ₹17,010 | 124 ₹22,320 | 165 ₹29,700 | 170 ₹30,600 |
| 7.00 | Supply and Fixing of LED Digital AC Voltmeter Ammeter Signal Lights 220 V Volt Amp Tester Detector Meter. | 30 | No. | 423.38 ₹12,701.54 | 335.8 ₹10,074 | 441 ₹13,230 | 588 ₹17,640 | 590 ₹17,700 |
| 8.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
a) 0.45m x 0.45m x 1m = 0.2025 m3
b) 0.35m x 0.35m x 1m = 0.1225 m3.
a-b = 0.2025 m3 - 0.1225m3 = 0.080 m3 x 44 no. = 3.52 m3. | 3.52 | sqm | 5,114.12 ₹18,001.70 | 4,056.8 ₹14,279.94 | 5,322 ₹18,733.44 | 7,107 ₹25,016.64 | 7,200 ₹25,344 |
| 9.00 | Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
a) 0.45 m x 1 m = 0.45 sqm
0.45sqm x 4side x 44 no.= 79.2 sqm
b) 0.35m x 1 m = 0.35 sqm
0.35 sqm x 4 side x 44 no. = 61.6 sqmm
a+b = 79.2 sqm + 61.6 sqm = 140.8 sqm | 140.8 | sqm | 424.54 ₹59,774.53 | 336.71 ₹47,408.77 | 442 ₹62,233.60 | 590 ₹83,072 | 600 ₹84,480 |
| 10.00 | Total impact of GST for the purpose of CTC | 1 | Nos | - | - | - | - | - |
Tender Value
₹5.6 L
EMD Value
₹7,100
Closing Date
18 Dec 2025, 5:00 pmClosed
PE(Elect.)
FFICE OF PO CHP-CPP, Piparwar Area, CCL, PO - Bachra, Dist - Chatra, Jharkhand - 829201 CHP-CPP,PIPARWAR
Proper Earthing Arrangement and Installation of Three Phase Surge Protection Devices (SPD, TPN) with MCB DB Box at Weighbridges and RFID based entry exit porta cabins under CHP CPP, PPR.
2025_CCL_348968_1
PE/Elec/CHP/PPR/E-NIT/25-26/15
Open Tender
Electrical and Maintenance Works
15 days
OFFICE OF PO CHP-CPP, Piparwar Area, CCL, PO - Ba
2 documents required · 2 mandatory
₹7,100
13 May 2026
8 Dec 2025
19 Dec 2025
8 Dec 2025
18 Dec 2025
8 Dec 2025
8 Dec 2025 - 15 Dec 2025
Amount
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (Location of earthing W/B no- 10- 2 no., W/B no-01- 02 no., W/B no- 11- 3 no. and 02 no in each RFID porta cabin)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A.
Supply and Fixing of Havells Surge Protection Devices 320 V DHSAARBC50320 (TP+N) with MCB BOX
Providing ang fixing 16 Sq mm Single Core copper Flexible Cables (Yellow/Green) for earthing connection.
Supply and Fixing of LED Digital AC Voltmeter Ammeter Signal Lights 220 V Volt Amp Tester Detector Meter.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) a) 0.45m x 0.45m x 1m = 0.2025 m3 b) 0.35m x 0.35m x 1m = 0.1225 m3. a-b = 0.2025 m3 - 0.1225m3 = 0.080 m3 x 44 no. = 3.52 m3.
Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. a) 0.45 m x 1 m = 0.45 sqm 0.45sqm x 4side x 44 no.= 79.2 sqm b) 0.35m x 1 m = 0.35 sqm 0.35 sqm x 4 side x 44 no. = 61.6 sqmm a+b = 79.2 sqm + 61.6 sqm = 140.8 sqm
Total impact of GST for the purpose of CTC
M/S MEHTA ELECTRONICS (BID ID -1202867)
SRI RAM CONSTRUCTION (BID ID -1203754)
SHREE RAM ELECTRICALS (BID ID -1203371)
B.K.ELECTRICAL (BID ID -1202832)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.42 MB
BOQ_361701.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid