| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | UV-VIS Spectrophotometer• Spectrophotometer should be of True Double – Beam Optics system. Sample compartment should have dedicated one reference cell holder and one sample cell holder.• System should be Czerny-Turner monochromator with LO-RAY-LIGH grade blazed holographic grating or equivalent.• System should have a light source of 20-W halogen lamp and deuterium lamp.• Automatic switch over of light source to be possible and auto position adjustment.• System should have a Fixed Spectral Bandwidth of 1nm.• System should have facility to use as stand-alone Keyboard-Display and with PC-controlled software.• Wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be ±0.1 nm at D2 656.1 nm & ± 0.3 nm for entire range.• Stray Light: Less than 0.02% at 220 nm (NaI)Less than 0.02% at 340 nm (NaNO2) Less than 0.5% at 198 nm (KCl)•Photometric range:Absorbance: -4 to 4 Abs Transmittance: 0% to 400%• System should have Photometric accuracy : ± 0.002 Abs at 0.5 Abs
± 0.004 Abs at 1.0 Abs
± 0.006 Abs at 2.0 Abs(measured using NIST930D/NIST1930 or equivalent)
• System should have a Baseline flatness: Less than ± 0.0006 Abs (1,100 to 190 nm, one hour after light source turned ON)• System should have a noise level: Less than 0.00005 Abs (700 nm).• Detector should be Silicon photodiode only.• System should have a USB Drive port to connect the printers or external drives.• System should compulsorily have Bio-method mode of measurement for Determining DNA and protein concentrations. Quantitates DNA or protein using the absorbance at 260/230nm.• System should be capable of Identification of organic compounds, Chemical reaction tracking and Enzyme reaction measurement.• PC with relevant hardware including monitor keyboard, mouse. | 3 | Nos | - | - | item1 |
| 2 | Fuming Hoods The proposed floor-mounted aerodynamic fume hood (1800 × 1000 × 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. The system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards—ideal for advanced research and chemical handling applications.1) Design & Compliance • Aerodynamic structure with automatic bypass airflow system.• Conforms to ASHRAE 110:2016 / EN 14175 standards, including tracer gas containment test.• Certified ASHRAE compliance required 2) Construction & Materials• Made of powder-coated Galvanized Iron (GI, 120 GSM, IS 277 compliant) • Sheet thickness: ≥1 mm (1.2 mm for structural supports) • Heavy-duty base frame: 60 × 40 × 2 mm• Phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean• SS 304 worktop with 15 mm raised edges for spill containment• SS 304 aerodynamic airfoil with anti- corrosive coating 3) Dimensions & Workspace• Usable workspace: 1500 mm (W) × 850 mm (D) × 1180 mm (H)• Clear viewing height: ≥1100 mm• Modular base cabinets with maintenance access 4) Coating & Finish• 8-stage chemical pre-treatment • Epoxy polyester / polyurethane coating (70–80 microns) • Corrosion resistance validated by 1000-hour salt spray test 5) Functional Features • Vertical sliding toughened glass sash (4–5 mm), counterbalanced • Openable front top panel for easy maintenance • Aerodynamic baffle system for efficient fume removal (light to heavy fumes) • Flow control damper for airflow regulation 6) Utilities & Safety • Integrated gas, water, and electrical fittings in corner posts • Remotely operated, color-coded service valves • Safety partition between utilities • No cable entry below sash (enhanced safety design) • Electrical fittings: Norysis /Legrand (230V, 5/16A, 50 Hz) 7) Accessories • PP cup sink with water tap and drainage • LED lighting with protective enclosure • Adjustable leveling screws (±10 mm) • Storage base cabinets with shelves and self-closing shutters 8) Centrifugal Blower Specifications • Remote, silent MS + FRP blower with chemical-resistant impeller • Designed to meet ANSI/AIHA Z9.5 face velocity standards • Airflow optimized for safe fume extraction • Motor: 1.5 / 2 / 3 HP, 3-phase, continuous duty
• Includes drain plug and corrosion-resistant construction. | 3 | Nos | - | - | item2 |
| 3 | Ice Cube Machine
Production in 24hrs -20kg
Store capacity -3.5kg
Cooling system -air cooled
Type of ice -bullet ice
Mass of ice -15gm
Refrigerant-R600a
Voltage/frequency /phase -200-240v-50Hz
Rated power-128w
Product dimension (WXDXH)
440x530x647 mm
Net Wt-27kg | 1 | Nos | - | - | item3 |
| 4 | weighing balance
capacity 0.001gm to 300gm , readability 0.001gm /1mg, repeatability 0.001g | 1 | Nos | - | - | item4 |
| 5 | Melting Point Apparatus
microprocessor apparatus, power supply 220V AV 50/60Hz, | 1 | Nos | - | - | item5 |
| 6 | Binocular microscope Total magnification: 40x- 1000x
Viewing head: Sling type Binocular head with 45o inclined and 360o rotable
Nose piece: Quadrupole Eyepiece: Wf 10× / 18 mm
Achromatic objective: DIN: 4×, 10×,40×,100 (oil immersion)
Focusing range: Coaxial coarse and fine adjustment, 13mm five division (0.002 mm) with tension control and locking stage
Stage: Double layer mechanical stage 140 mm×140mm
Moving range: 60×30mm
Condenser: Abbe type N.A (1.25) with iris diaphragm and filter
Illumination system: LED | 3 | Nos | - | - | item6 |
| 7 | Autoclave ( single lever Fully Automatic Verticle Autoclave The Vertical Autoclave should have Chamber Capacity of 35 ltr. • Working Chamber Dimension :300x500mm • The units internal chamber, cover lid and all wetted parts should be fabricated from stainless steel of 304 grade. • The Vertical Autoclave’s all joints should be smooth finished for crevice free internals. • The chamber should be hydrostatically tested
at 1.5 times of its working pressure. • The outer body should be made up of MS sheet with heat cured epoxy coating on both sides. • The cover lid should be equipped with single lever lock mechanism and lever handle molded from Industrial grade plastic.
•The lid cover should be provided with auto purge cum vacuum breaker valve and a manually operable valve for exhaust. • The unit should have a solenoid valve for additionally purging the air & normal exhaust. • The Vertical Autoclave should have stainless steel pressure gauge with dual range dial display in KPA and PSI along with a corelated temperature scale for steam in degrees Celsius. • The operations of the unit should be controlled by a microprocessor based controller. • The user should be able to set the temperature up to 122˚C in steps of 0.1˚C each. • The user should be able to set the Sterilization hold time in steps of 1 minutes each. • The timer range should be up to 95 mins. • In case of abrupt power failure / switching off, the Last Cycle which was set should remain in the memory. • The display for the parameters should be two line Alpha-Numeric digital display.• The unit should be equipped with Low Water Detection unit and should give Audio- Visual alarm in case of Low Water in the chamber and cut off the supply to the heater. • The unit should have safety valve to protect the equipment in case of over-pressurization. • The cover should be equipped with pressure interlock device. Also the heater should not start if the cover is open. • It should be provided with safety cut-out for high temperature. • The unit should give indication by audiovisual alarm on completion of set autoclave cycle. • The electrical safety should be ensured by inbuilt MCB.• The unit should be mounted on 04 Nos. PU coated castors out of which atleast 2 should have locking mechanism.• The Vertical Autoclave is pressure equipment & hence from safety point of view chamber should be designed as per ASME guidelines &Should be PED certified from a notified body. Photocopy of PED certificate to be submitted.
Supply Voltage: 230 V AC, 50HZ,Single phase. | 1 | Nos | - | - | item7 |
| 8 | Horizontal laminar air flow with Stainless Steel 304 Work Area in Fit:4x2x2 • Material of Construction: Stainless Steel 304 grade 1.2 mm complete. • Internal Dimensions: 1010 x 560 x 610 mm (L x B x H) +/- 5 mm 39.84" x 22" x 24" inches
• External Dimensions: 1130 x 740 x 2025 mm (L x B x H) +/- 5 mm 44.5" x 29.33" x79.72" inches • Velocity: 90 FPM at 6” from face of the filter +/- 20 Feet Per Minute • Table Top: Stainless Steel 304 Grade 1.2 mm Thickness • Body Finish: Off White Colour
• Design & Classification: Front Top Loading Pre-Filters / Complete work area will be of SS 304 including HEPA Grill, Table Top and Light Canopy Internal surface. As per IEST – RP – CC002.4 • Cleanliness Class: ISO Standard 14644 – 1 - Class 5 Noise Level: Less than 60 Db at 1 Meter from the face of the filter • Stages of Filtration: 1) Pre-Filters = 10µ with an efficiency of 90% (Washable HDPE media in FRP PU Coated Frame) 2) Mini pleat HEPA Filter Encased in Aluminum Frame Final = 0.3µ with an efficiency of 99.995% (HEPA Filter : AAF India Ltd.) • Front Door: Vertical Sliding Door 6 mm toughened glass with counter weight. • HEPA Filter Grill: Stainless Steel 304 Grade grills duly perforated and polished • Motor Blower Assembly :Motor Blower Assembly: Godrej” make variable speed motor mounted on PU coated FRP Blowers with Aluminum Impellers Switches & Speed Controller: Feather Touch Microprocessor Controlled • Fluorescent lighting: Osram” make 18 Watt Slim Tubelight – 2 nos. • Chokes for lighting: Philips” make Electronic Choke 18 watts – 3 nos. Ultra Violet Lighting: 1.5 feet length G15T8 15 Watt Sankyo Denki/ Philips make Electrical socket: 5 / 15 Amps socket – 1 Nos. • Side Panels: Stainless Steel 304 Grade • Pressure gauge: Minihelic gauge (Dwyer/Aerosense make) Made in U.S.A Gas / Vacuum Cock: Standard make (Optional)• Wheels & Leveling Lugs: PU solid wheels with plated brackets & Metallic Leveling Lugs • Power Supply & Service: Single phase 230V, 50Hz power supply Consumption : 230 Watts All services from Front and Back • Digital Display: With Digital Pressure indicator, UV Life indicator, UV Timer, HEPA Filter Life indicator (Optional) • Shipping Size: 1195 x 895 x 1550 mm ( L x W x H ) 47"x35"x61" inches • Weight with Wooden Packing: 260 Kgs
Net Unit Weight: 205 Kgs | 1 | Nos | - | - | item8 |
| 9 | Electronic Balance Top Loading with transparent glass/ Acrylic case cover Weighing Range: 10 mg to 200 g Minimum weighing capacity: 10 mg Maximum weighing capacity: 200 g Readability: 1 mg Display: Electronic (LCD) Weighing Pan: Stainless steel Weighing Pan Size: 90 mm to 120 mm Adjustable Tare range up to maximum capacity of the balance Level Indicator Response Time: 4 to 5 Sec Calibration: Built in Calibration/Auto calibration GMP Compliance Unit: mg, g, ct Key sound: Yes; Class:1; Power supply: AC 220V/50-60 HZ | 2 | Nos | - | - | item9 |
| 10 | High Precision PEN pH Meter Operating temperature: 0 to 99 °C Measurement resolution: 0.01 pH pH range: 0.00 to14 pH Unit Display: LCD/LED pH accuracy: ±0.05 Temperature Display Fully waterproof Moisture, Dust, Sand and Heat resistant Material: Epoxy shaft Other features: Auto off function, low battery indicator, units for temperature Power supply: AAA(1.5Volt) battery powered Accessories: pH calibration solutions | 5 | Nos | - | - | item10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
TermsConditions.pdf
Tender Documents • 0.45 MB
BOQ_30362.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid