Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹7.0 L+₹87,800 (14.5%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹7.2 L+₹1.1 L (17.8%)Rejected-Finance E 140 2010 BKP VILL AMTALLA PO DUMARCHIR DIST PAKUR PIN 814111 JHARKHAND | PAKUR | PAKUR | JHARKHAND | 814111 | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹7.8 L+₹1.8 L (28.9%)Rejected-Finance | L4 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
9 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AJIT KUMAR DWIVEDI
AGE I AF SINGARSI
Repair Maintenance of pump motor panel starter MCCB and connected works at AF Station Singarsi Under AGE I AF Singarsi
2022_MES_557613_1
C/8574/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹16,000
Yes
19 Nov 2022
13 Oct 2022
11 Nov 2022
14 Oct 2022
9 Nov 2022
20 Oct 2022
Amount
Repair and Maint Old LT panel suitable for 3 Phase 415 Volts of indoor floor mounted double door with locking arrangement ,both side open type made out 2 mm thick CRCA sheet with 600 amps rated copper bus bar for phases, and 600amps for neutral ,insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTs and internal wiring with suitable size of PVC insulated copper wire thimbling and cable entry boxes with cable glandand power coated paint with following :- INCOMER (a) Voltmeter(digital type) 0-600 volt -01No (Make : AE or equivalent as approved by AGE(I)) (b) Ampere meter (digital type) 0-630 amps - 01 No (Make : AE or equivalent as approved by AGE(I)) (c ) Watt meter (digital type) (Make :L&T or equivalent as approved by AGE(I)) (d) Rotere switch (digital type)Make :L&T or equivalent as approved by AGE(I) (e) Power factor meter (digital type)Make :L&T or equivalent as approved by AGE(I) (f) Indicator lamp (set of3) - 01 Set (g) Phase Sequance indicater(digital type) (h) Frequency meter (digital type) 40 Hz to 90 Hz
Repair and Maint Old, LT panel suitable for 3 Phase 415 Volts of indoor floor mounted double door with locking arrangement ,both side open type made out 2 mm thick CRCA sheet with 600 amps rated copper bus bar for phases, and 600amps for neutral , insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTs and internal wiring with suitable size of PVC insulated copper wire thimbling and cable entry boxes with cable glandand power coated paint with following :- INCOMER (a ) Voltmeter(digital type) 0-600 volt (Make : AE or equivalent as approved by AGE(I)) (b) Ampere meter (digital type) 0-630 amps (Make : AE or equivalent as approved by AGE(I)) (c) Watt meter (digital type) (Make :L&T or equivalent as approved by AGE(I)) (d) Rotere switch (digital type)Make :L&T or equivalent as approved by AGE(I) (e) Power factor meter (digital type)Make :L&T or equivalent as approved by AGE(I) (f ) Indicator lamp (set ) (g) Phase Sequance indicater(digital type) (h) Frequency meter (digital type) 40 Hz to 90 Hz
S & F for fully automatic star-delta starters in sheet-steel enclosure type MN 16F with single phase protection feature suitable for 75 HP Motor, 60 KW, rating AC-3 duty, 415V, 50 Hz 3 phase, relay max range 45-75 Amp after taking down old u/s starter complete all as specified and directed. (Make : L&T,or equivalent of Havells / Legrand)
S & F for fully automatic star-delta starters in sheet-steel enclosure type MN 16F with single phase protection feature suitable for 60 HP Motor,48 KW, rating AC-3 duty, 415V, 50 Hz 3 phase, relay max range 30-50 Amp after taking down old u/s starter complete all as specified and directed. (Make : L&T,or equivalent of Havells / Legrand)
Supply and fixing Euroload Change over switch 630 Amps rated capacity,(with box) FN- TPN in SS enclosure , mounting on wall /Panel,including cable interlock top & bottom , cofirming to IEC 60947-3, IS/IEC 60947-3 of 50 Hz, 415 Volt as per following amps rated capacitycomplete with cable connection of existing DG set and Transformer as directed by Engr-in Charge . Make- L&T/ Havells or equiavelent.all as specified and as directed by Engineer-in-charge.
Supply and fixing Euroload Change over switch 400 Amps rated capacity,(with box) FN- TPN in SS enclosure , mounting on wall /Panel, including cable interlock top & bottom , cofirming to IEC 60947-3, IS/IEC 60947-3 of 50 Hz, 415 Volt as per following amps rated capacitycomplete with cable connection of existing DG set and Transformer as directed by Engr-in Charge . Make- L&T /Havells or equiavelent.all as specified and as directed by Engineer-in-charge.
M&L and testing of cable XLPE insullated screened PVC beaded galvnized steel strip electric power cable (heavy duty) with aluminum stranded conductor,1100V Grade of size 120 sqmm 3.5 core cross sectional area complete connection with copper lugs. all as specified and as directed by Engineer-in-charge.
M&L and testing of cable XLPE insullated screened PVC beaded galvnized steel strip electric power cable (heavy duty) with aluminum stranded conductor,1100V Grade of size 150sqmm 3.5 core cross sectional area complete connection with copper lugs.complete all as specified and as directed by Engineer-in-charge.
M&L and testing of cable XLPE insullated screened PVC beaded galvnized steel strip electric power cable (heavy duty) with aluminum stranded conductor,1100V Grade of size 35 sqmm 3.5 core cross sectional area complete connection with copper lugs. all as specified and as directed by Engineer-in-charge.
M&L for disconnecting/taking out unserviceable MCCB from existing panel board and supply and fix MCCB 3 pole 415 Volts adjustable type 630 Amps with breaking capacity 50KA. (Make L&T or equivalent in Havells/BCH) /). all as specified and directed by Engr-in-Charge.
M&L for disconnecting/taking out unserviceable MCCB from existing panel board and supply and fix MCCB 3 pole 415 Volts adjustable type 400 Amps with breaking capacity 36KA.(Make L&T or equivalent in Havells/BCH) /) complete all as specified and directed by Engr-in-Charge.
M&L for disconnecting/taking out unserviceable MCCB from existing panel board and supply and fix MCCB 3 pole 415 Volts adjustable type 160 Amps with breaking capacity 36KA.(Make L&T or equivalent in Havells/BCH) /) complete all as specified and directed by Engr-in-Charge.
Three Phase preventor relay SPPR type with timer 415 volts of (Make : L&T or equivalaent in Havells/BCH).complete all as specified and directed by Engr-in-Charge.
M&L for painting steel and iron surfaces of any description (in old surfaces), over 10 cm in width or girth not otherwise described with 1coat of synthetic enamel paint(ordinary tint). all as specified and directed.
S&F LED street light fitting 60 watt 230 V AC out door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermai management in multiple optics complete with IP 65/66 protection complete.
S&F for LED flood light 70 watt 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driverr and lamp. all as specified and directed by Engr-in-Charge.
S&L synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006(superseding IS 5424) suitable for electrical shock safety of sizes 2mx1m. all as specified and directed by Engr-in-Charge.
S&F exhaust fan, steel body AC single phase. 230 V of size 450mm sweep with, blades, and louvers.all as specified and directed by Engr-in-Charge.
M&L for providing cement concrete type C1 1:2:4 (20 mm graded aggregate) in lintels upto 1.5 m clear span, cills, steps, seismic and other similar using bands plinth courses, string courses lacing courses, parapets and railings upto 60 cm in height.copings, kneelers, apex stones bed plates, water troughs and the like including weathering slightly rounded or chamfered angles and throating as directed.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by medium 40mm dia GI pipe connected to main switch board or main control board or equipment and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2020(Part-I).
M/S SINGH ENTERPRISE
M/S MBS TRADING CO
M/S AMARNATH AGARWALLA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .