Commandant ARC and MC
Assam Rifles Constr and maint coy
Repair Maint of VCBs, Control Panels with connected accessories at 33 KV main power house at Laitkor
2023_ARMHA_761820_1
ENG/III-235/2023-24/46 dated 14 Jul 2023
Open Tender
Civil Works
Works
270 days
Laitkor
As per Tender document
2 documents required · 2 mandatory
₹500
Yes
Commandant ARC and MC
₹36,000
Yes
21 Aug 2023
14 Jul 2023
21 Jul 2023
14 Jul 2023
20 Jul 2023
14 Jul 2023
14 Jul 2023 - 20 Jul 2023
Servicing of HT Breaker 11KV, 3 Phase with cleaning of breaker panel inside out and enclosure, cleaning of VI Housing and breaker spout, tightining of LT terminal of CT/PT and control terminals, CT ratio and insulation test and busber cleaning for following makes:- (a) BIECCO-VB8A-800A-12KV-4 Nos (b) CG-UNTVAC-400A-12KV-4 Nos Note: Spare required for servicing will be measured separately Note: All HT cable and power control wiring disconnection after repair of VCB to be connected with HT cable.
Testing of HT Breaker 11KV, 3 Phase including testing of breaker timing and contact resistance test (CRM)., Relay test by primary / secondary injection set (Over current & Eart fault relay).for following makes:- (a) BIECCO-VB8A-800A-12KV-4 Nos (b) CG-UNTVAC-400A-12KV-4 Nos
Servicing of HT Breaker 33KV, 3 Phase consisting of cleaning of breaker panel inside out and enclosure, cleaning of VI Housing and breaker spout, tightining of LT terminal of CT/PT and control terminals, CT ratio and insulation test and busber cleaning for following makes:- (a) 33KV-ARVA VCB-1 No (b) CG-SF6 BKR -1 No Note: Spare required for servicing will be measured separately
Testing of HT Breaker 33KV, 3 Phase including testing of breaker timing and contact resistance test (CRM)., Relay test by primary / secondary injection set (Over current & Eart fault relay).for following makes:- (a) 33KV-ARVA VCB-1 No (b) CG-SF6 BKR -1 No
Servicing of On Load Tap Changer of 33/11 KV Power Transformer of capacity 3.2 MVA strip opening of transformer after unscrewing nuts /bolts screws and connected accessories such as breather, conservator tank, temp gauge, taking out the core for replacement of defective parts and transportation back to the site after repairs and installing, connecting up, testing and commissioning at the site complete all as specified and directed. Spare will be measured separately. Notes : - (a) Transformer oil shall be drained out by the contractor in suitable capacity MS drums to be arranged by the contractor. The said drained out transformer oil shall be refilled in the transformer duly dehydrated after repair and the cost thereof shall be included in unit rate quoted against the respective item of this schedule. (b) Testing of transformer after repair shall be carried out with the following test and the cost of testing shall deem to be included in unit rate quoted against this item
Supply only Closing coil for VCB Make: BIECCO-VB8A-800A-12KV
Supply only Tripping coil for VCB Make: BIECCO-VB8A-800A-12KV
Supply only digital, avana relay for Over current/Earth Fault protection including replacement of old CDG relay to dighital relay for VCB Make: BIECCO-VB8A-800A-12KV
Supply only Battery power pack for VCB Make: BIECCO-VB8A-800A-12KV
Supply only 86 master trip relay for VCB Make: BIECCO-VB8A-800A-12KV
Supply only Porcelin spout with shutter for VCB Make: BIECCO-VB8A-800A-12KV
Supply only rear and front bushing for VCB Make: BIECCO-VB8A-800A-12KV
Supply only VI Bottle for VCB Make: BIECCO-VB8A-800A-12KV
Supply only KV meter digital for VCB Make: BIECCO-VB8A-800A-12KV
Supply only Amps meter digital for VCB Make: BIECCO-VB8A-800A-12KV
Supply only TNC switch for VCB Make: BIECCO-VB8A-800A-12KV
Supply only Indication lamp for VCB Make: BIECCO-VB8A-800A-12KV
Supply only 11KV Insulator for VCB Make: BIECCO-VB8A-800A-12KV
Supply only Closing coil for VCB Make:CG-UNTVAC-400A-12KV
Supply only Tripping coil for VCB Make: CG-UNTVAC-400A-12KV
Supply only digital, avana relay for Over current/Earth Fault protection including replacement of old CDG relay to dighital relay for VCB Make: CG-UNTVAC-400A-12KV
Supply only Battery power pack for VCB Make: CG-UNTVAC-400A-12KV
Supply only 86 master trip relay for VCB Make: CG-UNTVAC-400A-12KV
Supply only Porcelin spout with shutter for VCB Make: CG-UNTVAC-400A-12KV
Supply only VI Bottle for VCB Make: CG-UNTVAC-400A-12KV
Supply only KV meter digital for VCB Make: CG-UNTVAC-400A-12KV
Supply only Amps meter digital for VCB Make: CG-UNTVAC-400A-12KV
Supply only TNC switch for VCB Make: CG-UNTVAC-400A-12KV
Supply only Indication lamp for VCB Make: CG-UNTVAC-400A-12KV
Supply only 11KV Insulator for VCB Make: CG-UNTVAC-400A-12KV
Supply only SF6 Gas filing for CG SF6 out door breaker
Supply only Pressure gauge for CG SF6 out door breaker
Supply only moving parts for CTR on load tap changer 33/11 KV Power transformer
Supply only fix copper connector terminal for CTR on load tap changer 33/11 KV Power transformer
Supply only breader wire for CTR on load tap changer 33/11 KV Power transformer
Supply only for Rubber mat of 1 meter x 2 meter x 19 mm
Supply only for Electric rubber hand gloves 11 KV
Supply only for Electric rubber hand gloves 33 KV
Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of a set of three 11 KV disc insulator for 33 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Shree Meghalaya Construction & Supply Co.
M/S B T ENGINEERS
Arbind Enterprise
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .