S.E. Electrical Circle (RandB) Odisha, BBSR
S.E. Electrical Circle (RandB) Odisha, BBSR, Nirman Soudha, Unit-V, 751001.
Shifting of line and Sub-Station for Road Widening work for improvement such as widening and strengthening to Paralakhemundi Municipality road from Ch. 0/000Km to 10/400 Km , Gajapati.
2026_EICCL_125524_4
Bid Identification No.S.E.E.C (RandB) 27/2025-26
National Competitive Bid
Electrical Works
Percentage
180 days
Paralakhemundi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹1.0 L
6 Mar 2026
11 Feb 2026
26 Feb 2026
11 Feb 2026
25 Feb 2026
11 Feb 2026
11 Feb 2026 - 18 Feb 2026
1. Khetri sahi-Namangada WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
9Mtr long 300Kg PSC Pole
RCC Base Plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (2Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
11 KV Pin Insulator (polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
Part-II 9Mtr long 300Kg PSC Pole
RCC Base plate
1.1KV LT AB Cable 4x50+1x50+1x16
1.1KV LT AB Cable 4x35+1x35+1x16
CAP CABLE END FOR ABC 50 SQMM
CAP CABLE END FOR ABC 35 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sundries
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 11M WPB Poles in ratio 1:1.5:3 =0.45Cum. @ 6648.85 =0.45 x 6648.85 =Rs.2991.98
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6400=Rs.720.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Dismantling charges of LT Pole
Dismantling charges of LT Line
2.Khetri Sahi 9Mtr long 300Kg PSC Pole
RCC Base Plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
Galvanisation of all RS and MS materials
11 KV Pin Insulator (polymer)
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
Part-II 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 2X35+1x25
CAP CABLE END FOR ABC 35 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 11M WPB Poles in ratio 1:1.5:3 =0.45Cum. @ 6648.85 =0.45 x 6648.85 =Rs.2991.98
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6400=Rs.720.00
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Dismantling charges of LT Pole
Dismantling charges of LT Line
3.Nalu sahi 9Mtr long 300Kg PSC Pole
8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 2X35+1x25
CAP CABLE END FOR ABC 35 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6400=Rs.720.00
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Dismantling charges of LT Pole
Dismantling charges of LT Line
4.Chandangiri-Nalusahi WPB 160x152 (30.44KG/Mtr.), 11 mtr-with base plate 300x300x12
9Mtr long 300Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
Galvanisation of all RS and MS materials
11 KV Pin Insulator (polymer)
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
Top Pressure channel (GI) 100x50x6mm 2.8mtr long ,2nos(9.2kg/Mtr)
(75x40x6mm chanel (GI) for bracing 2.8Mtr, 2Nos) (6.8Kg/Mtr)
50x50x6mm angle (GI) for bracing, 3mtr long, 2Nos. (4.5kg/mtr) (total 6mtr long)
AB Switch mounting channel (GI) (75x40x6mm, 2.8Mtr,2Nos)(6.8Kg/Mtr)
AB Switch side support G.I. channel 100x50x6mm, each 0.35kgmtr, 2nos (@9.2Kg per meter)
Channel support for down pipe 75x40x6mm, 6.8Kg/mtr, each channel length 0.8Mtr, 1NO
11 KV A.B Switch 3pole (400A)
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
11 KV Pin Insulator (polymer)
12KV 10KA 11 KV Lighting Arrestor
H.T.Stay Set (Complete)
Stay Insulator
Stay Clamp
7/10 (3.25mm dia per strand) SWG GI stay wire (2.19Mtr/Kg)
25 X 6 mm GI Flat(For others)
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
Black Paint
Yellow colour paint for back ground
GI Bolts, Nuts & washers
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 11M WPB Poles in ratio 1:1.5:3 =0.45Cum. @ 6648.85 =0.45 x 6648.85 =Rs.2991.98
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6400=Rs.720.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Dismantling charges of LT Pole
5.Chandangiri village 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x50+1x50+1x16
CAP CABLE END FOR ABC 50 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6400=Rs.720.00
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Dismantling charges of LT Pole
Dismantling charges of LT Line
6.Adwanaguda-Chandangiri village WPB 160x152 (30.44KG/Mtr.), 11 mtr-with base plate 300x300x12
10Mtr long 330Kg PSC Pole
9Mtr long 300Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
Galvanisation of all RS and MS materials
11 KV Pin Insulator (polymer)
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
Concreting of 11M WPB Poles in ratio 1:1.5:3 =0.45Cum. @ 6648.85 =0.45 x 6648.85 =Rs.2991.98
Concreting of 10 Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Concreting of 10 Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6400=Rs.720.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Dismantling charges of LT Pole
7.Adawanvillage 9Mtr long 300Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (6Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
11 KV Pin Insulator (polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
55mm² AAA Conductor
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
25 KVA DSS 9Mtr Long 300Kg PSC Pole
RCC base Plate
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Top Pressure G.I. channel 100x50x6mm 2.8mtr long ,2nos (@9.2kg/Mtr)
Transformer mounting G.I. channel 100x50x6mm 2.8mtr long, 2nos (@9.2kg/Mtr)
HG Fuse and AB Switch mounting G.I. channel (75x40x6mm, 2.8Mtr,4Nos) (6.8Kg/Mtr)
Cantilever GI Channel for supporting AB Switch arm, 75x40x6mm, 1mtr long, 2Nos (6.8Kg per meter)
Contilever angle for supporting AB Switch 50x50x6mm GI angle 1mtr long, 2Nos (4.5Kg per meter)
Transformer Belting 50x50x6mm G.I. angle, 2.8mtr long, 2nos (4.5kg/mtr) with side angle (total 7mtr long)
G.I. Angle for mounting LT Distribution box 50x50x6mm 1mtr long ,2nos(3.5Kg/Mtr)
AB Switch side support G.I. channel 100x50x6mm, each 0.35kgmtr, 2nos (@9.2Kg per meter)
G.I. Channel support for down pipe 75x40x6mm, 6.8Kg/mtr, each channel length 0.8Mtr, 1NO
Disc insulator (T&C) 45KN Polymer
Hardware fitting (T&C) 45KN
11 KV A.B Switch 3Pole (200A)
11 KV H.G fuse 3Pole (200A)
12KV 10KA 11 KV Lighting Arrestor
H.T.Stay Set(Complete)
Stay Insulator
Stay Clamp
7/10 (3.25mm dia per strand) SWG GI stay wire(2.19Mtr/Kg)
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
25 X 6 mm GI Flat
25 x 4 mm GI Flat (For Neutral)
55mm² AAA Conductor
PG clamp for 55mm² AAA Conductor
25KVA, 11/0.4KV (AL)Transformer, BIS Energy level-II
LT distribution box with MCCB, Aluminium Busbar of single Bay with Kit Kat fuse for 25KVA S/S
1Cx50m LT XLPE Cable(Un-armoured) 4Nos 10Mtr each
GI Bolts, Nuts & Washers of assorted size
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
L.T.line-0.565 KM 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x35+1x35+1x16
CAP CABLE END FOR ABC 50 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @ 6648.85=0.375x6400 =Rs.2400.00
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85= 0.1125x6648=Rs.748.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Brick wall boundaring (size =3Mtrx3Mtrx1.5Mtr) with fixing of iron gril gate sand and metal spreading etc
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Survey and digitization of New DSS and its internals including attrubutes
Dismantling charges of 9M PSC Pole
Dismantling charges of HT Line
Dismantling charges of 25kVA DSS
Dismantling charges of 8M PSC Pole
Dismantling charges of LT Span
8.jhulla Village 9Mtr long 300Kg PSC Pole
8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable (2x35+1x25)
CAP CABLE END FOR ABC 35 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6400=Rs.720.00
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
9.Rasik Rajpur vil. WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
9Mtr long 300Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (10Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
11 KV Pin Insulator (polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
55mm² AAA Conductor
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
25 KCA DSS 9Mtr Long 300Kg PSC Pole
RCC base Plate(500mmX500mmX10mm) for PSC pole
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Top Pressure G.I. channel 100x50x6mm 2.8mtr long ,2nos (@9.2kg/Mtr)
Transformer mounting G.I. channel 100x50x6mm 2.8mtr long ,2nos (@9.2kg/Mtr)
HG Fuse and AB Switch mounting G.I. channel (75x40x6mm, 2.8Mtr,4Nos)(6.8Kg/Mtr)
Contilever GI Channel for supporting AB Switch arm, 75x40x6mm, 1mtr long, 2Nos (6.8Kg per meter)
Contilever angle for supporting AB Switch 50x50x6mm GI angle 1mtr long, 2Nos (4.5Kg per meter)
Transformer Belting 50x50x6mm G.I. angle, 2.8mtr long,2nos(4.5kg/mtr) with side angle(total 7mtr long)
G.I. Angle for mounting LT Distribution box 50x50x6mm 1mtr long ,2nos(3.5Kg/Mtr)
AB Switch side support G.I. channel 100x50x6mm, each 0.35kgmtr, 2nos (@9.2Kg per meter)
G.I. Channel support for down pipe 75x40x6mm, 6.8Kg/mtr, each channel length 0.8Mtr, 1NO
Disc insulator (T&C) 45KN Polymer
Hardware fitting (T&C) 45KN
11 KV A.B Switch 3Pole (200A)
11 KV H.G fuse 3Pole (200A)
12KV 10KA 11 KV Lighting Arrestor
H.T.Stay Set(Complete)
Stay Insulator
Stay Clamp
7/10 (3.25mm dia per strand) SWG GI stay wire(2.19Mtr/Kg)
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
25 X 6 mm GI Flat
25 x 4 mm GI Flat (For Neutral)
55mm² AAA Conductor
PG clamp for 55mm² AAA Conductor
25KVA, 11/0.4KV (AL)Transformer, BIS Energy level-II
LT distribution box with MCCB, Aluminium Busbar of single Bay with Kit Kat fuse for 25KVA S/S
1Cx50m LT XLPE Cable(Un-armoured) 4Nos 10Mtr each
GI Bolts, Nuts & Washers of assorted size
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
L.T. Line 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x35+1x35+1x16
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 11Mt WPB Poles in ratio 1:1.5:3 =0.450Cum. @ 6648.85= 0.450x6648 =Rs.2991.6
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @ 6648.85=0.375x6400 =Rs.2400.00
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85= 0.1125x6648=Rs.748.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Brick wall boundaring (size =3Mtrx3Mtrx1.5Mtr) with fixing of iron gril gate sand and metal spreading etc
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW database
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Survey and digitization of New DSS and its internals including attrubutes
Dismantling charges of 9M PSC Pole
Dismantling charges of HT Line
Dismantling charges of 25kVA DSS
Dismantling charges of 8M PSC Pole
Dismantling charges of LT Span
10.Bidua Village WPB 160x152 (30.44KG/Mtr.), 11 mtr- with base plate 300x300x12
10Mtr long 330Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (2Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
11 KV Pin Insulator (Polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
55mm² AAA Conductor
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
16 KVA 9Mtr Long 300Kg PSC Pole
RCC Base plate
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
Top Pressure G.I. channel 100x50x6mm 2.8mtr long ,2nos (@9.2kg/Mtr)
Transformer mounting G.I. channel 100x50x6mm 2.8mtr long ,2nos (@9.2kg/Mtr)
HG Fuse and AB Switch mounting G.I. channel (75x40x6mm, 2.8Mtr,4Nos)(6.8Kg/Mtr)
Contilever GI Channel for supporting AB Switch arm, 75x40x6mm, 1mtr long, 2Nos (6.8Kg per meter)
Cuntiliver angle for supporting HG fuse (50x50x6) MM, 1.5 Mtr. ling, 2Nos.(4.5Kg/Mtr)
Transformer Belting 50x50x6mm G.I. angle, 2.8mtr long,2nos(4.5kg/mtr) with side angle(total 7mtr long)
G.I. Angle for mounting LT Distribution box 50x50x6mm 1mtr long ,2nos(3.5Kg/Mtr)
AB Switch side support G.I. channel 100x50x6mm, each 0.35kgmtr, 2nos (@9.2Kg per meter)
G.I. Channel support for down pipe 75x40x6mm, 6.8Kg/mtr, each channel length 0.8Mtr, 1NO
Disc insulator (T&C) 45KN Polymer
Hardware fitting (T&C) 45KN
11 KV A.B Switch 2pole(200A)
11 KV H.G fuse 2 pole (200A)
11 KV Lighting Arrestor (12KV,5KA)
H.T.Stay Set(Complete)
Stay Insulator
Stay Clamp
7/10 (3.25mm dia per strand) SWG GI stay wire(2.19Mtr/Kg)
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 2.5 mtr long
25 X 6 mm GI Flat
25 x 4 mm GI Flat (For Neutral)
55mm² AAA Conductor
PG clamp for 55mm² AAA Conductor
Cost of 16 KVA,11/0.23KV transformer
LT Distribution box for 16KVA S/S
16 mm² LT 2core PVC cable
GI Bolts, Nuts & Washers of assorted size
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape)
L.T.line- 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 2x35+1x25
CAP CABLE END FOR ABC 35 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
civil Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 11M WPB Poles in ratio 1:1.5:3 =0.450Cum. @ 6648.85=0.450x6648 =Rs.2991.6
Concreting of 10Mtr. poles in ratio 1:1.5:3 =0.415Cum.
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum.
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85= 0.1125x6648=Rs.748.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Brick wall boundaring (size =3Mtrx3Mtrx1.5Mtr) with fixing of iron gril gate sand and metal spreading etc
Survey of incremental/delta network and assets changes of HT network and updation in GESW databas
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Survey and digitization of New DSS and its internals including attrubutes
Dismentling Dismantling charges of DP Structure
Dismantling charges of 16KVA DSS
Dismantling charges of 8Mt PSC Pole
Dismantling charges of LT Span
11.Paricha village-I WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
Top Pressure channel (GI) 100x50x6mm 2.8mtr long ,2nos(9.2kg/Mtr)
(75x40x6mm chanel (GI) for bracing 2.8Mtr,2Nos)(6.8Kg/Mtr)
50x50x6mm angle (GI) for bracing, 3mtr long, 2Nos. (4.5kg/mtr) (total 6mtr long)
AB Switch mounting channel (GI) (75x40x6mm, 2.8Mtr,2Nos)(6.8Kg/Mtr)
AB Switch side support G.I. channel 100x50x6mm, each 0.35kgmtr, 2nos (@9.2Kg per meter)
Channel support for down pipe 75x40x6mm, 6.8Kg/mtr, each channel length 0.8Mtr, 1NO
11 KV A.B Switch 3pole (400A)
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
11 KV Pin Insulator (polymer)
12KV 10KA 11 KV Lighting Arrestor
H.T.Stay Set (Complete)
Stay Insulator
Stay Clamp
7/10 (3.25mm dia per strand) SWG GI stay wire(2.19Mtr/Kg)
25 X 6 mm GI Flat(For others)
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
Black Paint
Yellow colour paint for back ground
GI Bolts, Nuts & washers
Sunderies (Al Binding tape,Insulation tape, etc.)
2ph,2 watt 9Mtr long 300Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100X50X6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (2Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
11 KV Pin Insulator (polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
55mm² AAA Conductor
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
Civil Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 11M WPB Poles in ratio 1:1.5:3 =0.450Cum. @6400=0.450x6648=Rs.2991.6
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6648=Rs.748.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
12.paricha village-II 9Mtr long 300Kg PSC Pole
8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x50+1x50+1x16
CAP CABLE END FOR ABC 50 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
CIVIL Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6648=Rs.748.00
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
13.Jhami -Oli-I 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x35+1x35+1x16
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6648=Rs.748.00
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
14. Jhami Hanuman Mandir 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x35+1x35+1x16
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6648=Rs.748.00
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
15.Jhami G.P-63 KVA 9Mtr long 300Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100x50x6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (10Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
11 KV Pin Insulator (polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
55mm² AAA Conductor
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
63 KVA DSS 9Mtr long 300Kg PSC Pole
RCC Base Plate
Top Pressure channel (100x50x6) MM MS, 2.8Mtr. long , 2Nos. (9.2kg/Mtr)
Transformer mounting channel (100x50x6) MM MS, 2.8Mtr. long , 2Nos. (9.2kg/Mtr)
HG Fuse and AB Switch mounting channel (75x40x6) MM MS, 2.8Mtr. ling, 4Nos.(6.8Kg/Mtr)
Transformer Belting (50x50x6)MM MS angle, 2.8Mtr long, 2Nos.(4.5kg/mtr) with side angle(total 7.0 Mtr long)
Cuntiliver channel for supporting HG fuse (75x40x6) MM MS, 1.0 Mtr. ling, 2Nos.(6.8Kg/Mtr)
Cuntiliver angle for supporting HG fuse (50x50x6) MM MS, 1.5 Mtr. ling, 2Nos.(4.5Kg/Mtr)
Angle for mounting LT Distribution box (35x35x5) MM MS, 1Mtr long , 2Nos. (3.5Kg/Mtr)
AB Switch side support channel 100x50x6mm, 9.2Kg/Mtr, each chanel length 0.35Mtr, 2nos of chanel required
Channel support for down pipe 75x40x6mm, 6.8Kg/mtr, each channel length 0.8Mtr, 1No
11 KV A.B Switch (200A, 3Pole, 50Hz)
11 KV HG Fuse (200A, 3Pole) with PI
Disc Insulator (T & C) 45 KN (Polymer)
Hard Ware Fitting(T & C ) 45 KN
25 X 6 mm GI Flat(For others)
25 x 4 mm GI Flat(For Lightning Arrestor)
12KV 10KA 11 KV Lighting Arrestor
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
55mm² AAA Conductor
1Cx95mm² XLPE Cable 4Nos 10Mtr each
LT distribution box with MCCB, Aluminium Busbar of single Bay with Kit Kat fuse for 63KVA S/S
63KVA, 11/0.4KV (AL)Transformer, BIS Energy level-II.
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
PG Clamp for 55mm² AAA Conductor
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
GI Bolts, Nuts & washers
Black Paint
Yellow colour paint for back ground
Sunderies(Al Binding tape,Insulation tape,Fencing, Metal Spreding, Paint, etc.)
L.T Line 9Mtr long 300Kg PSC Pole
8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x50+1x50+1x16
CAP CABLE END FOR ABC 50 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
CIVIL Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2cUM @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @6400=0.375x6400=Rs.2400.00
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @6400=0.1125x6648=Rs.748.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Brick wall boundaring (size =3Mtrx3Mtrx1.5Mtr) with fixing of iron gril gate sand and metal spreading etc
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Survey and digitization of New DSS and its internals including attrubutes
Dismenting Dismantling charges of 9Mt PSC Pole
Dismantling charges of HT Line
Dismantling charges of 63KVA DSS
Dismantling charges of 8M PSC Pole
Dismantling charges of LT Span
16.Jhami high school-100 KVA 9Mtr long 300Kg PSC Pole
RCC Base plate
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100x50x6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (4Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
11 KV Pin Insulator (polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
55mm² AAA Conductor
PG Clamp for 55mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
100 kva dss 9Mtr long 300Kg PSC Pole
RCC Base Plate
Top Pressure channel (100x50x6) MM MS, 2.8Mtr. long , 2Nos. (9.2kg/Mtr)
Transformer mounting channel (100x50x6) MM MS, 2.8Mtr. long , 2Nos. (9.2kg/Mtr)
HG Fuse and AB Switch mounting channel (75x40x6) MM MS, 2.8Mtr. ling, 4Nos.(6.8Kg/Mtr)
Transformer Belting (50x50x6)MM MS angle, 2.8Mtr long, 2Nos.(4.5kg/mtr) with side angle(total 7.0 Mtr long)
Cuntiliver channel for supporting HG fuse (75x40x6) MM MS, 1.0 Mtr. ling, 2Nos.(6.8Kg/Mtr)
Cuntiliver angle for supporting HG fuse (50x50x6) MM MS, 1.5 Mtr. ling, 2Nos.(4.5Kg/Mtr)
Angle for mounting LT Distribution box (35x35x5) MM MS, 1Mtr long , 2Nos. (3.5Kg/Mtr)
AB Switch side support channel 100x50x6mm, 9.2Kg/Mtr, each chanel length 0.35Mtr, 2nos of chanel required
Channel support for down pipe 75x40x6mm, 6.8Kg/mtr, each channel length 0.8Mtr, 1No
11 KV A.B Switch (200A, 3Pole, 50Hz)
11 KV HG Fuse (200A, 3Pole) with PI
Disc Insulator (T & C) 45 KN (Polymer)
Hard Ware Fitting(T & C ) 45 KN
25 X 6 mm GI Flat(For others)
25 x 4 mm GI Flat(For Lightning Arrestor)
12KV 10KA 11 KV Lighting Arrestor
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
55mm² AAA Conductor
1Cx150mm² XLPE Cable 4Nos 10Mtr each
LT distribution box with MCCB, Aluminium Busbar of two Bay with Kit Kat fuse for 100KVA S/S
100KVA, 11/0.4KV (AL)Transformer, BIS Energy level-II.
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
PG Clamp for 55mm² AAA Conductor
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
GI Bolts, Nuts & washers
Black Paint
Yellow colour paint for back ground
Sunderies(Al Binding tape,Insulation tape, etc.)
L.T.Line 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x50+1x50+1x16
CAP CABLE END FOR ABC 50 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
Dismentling Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @ 6648.85
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648=Rs.748.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Brick wall boundaring (size =3Mtrx3Mtrx1.5Mtr) with fixing of iron gril gate sand and metal spreading etc
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
Survey of incremental/delta network and assets changes of LT network and updation in GESW databas
Survey and digitization of New DSS and its internals including attrubutes
Dismentling Dismantling charges of 9Mt PSC Pole
Dismantling charges of HT Line
Dismantling charges of 63KVA DSS
Dismantling charges of 8M PSC Pole
Dismantling charges of LT Span
17.Jhami H/S 8 Mtr long 200kg PSC pole
RCC Base plate
1.1KV LT AB Cable 4x50+1x50+1x16
CAP CABLE END FOR ABC 50 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
CIVIL Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @ 6648.85
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648=Rs.748.00
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
Dismentling Dismantling charges of 9Mt PSC Pole
Dismantling charges of LT Span
18.Jhami A.B. Switch WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
MS 11 KV 'V' Cross Arm (10.2Kg Each)
MS 'F' Clamp (Pole top Bracket) (2.9Kg each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100x50x6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (6Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T&C) 45 KN Polymer
11 KV Hard Ware Fitting(T&C Type) 45KN
11 KV Pin Insulator (polymer)
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
80mm² AAA Conductor
PG Clamp for 80mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
75X40X6 mm, GI Channel St Cross arm 1.5Mtr @ 6.8Kg/mtr (4Nos) for road cross guarding
No-6 GI Wire for road cross Guarding
G.I pipe Earthing 40 mm dia medium gauge(3.25mm thick ness) 3 mtr long
50x6mm GI Flat for earthing
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
Dismentling Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @ 6648.85
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648=Rs.748.00
Material for earthing including masonary work for earth pit, and cement plate cover with salt, charcoal etc.
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
Dismentling Dismantling charges of H.T. Pole
Dismantling charges of HT Line
00.0/00 km to 10/400 km WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300x12
MS 11 KV 'V' Cross Arm (10.2Kg Each)
G.I. Back Clamp for 'V' Cross Arm (11KV) (0.85Kg Each)
100x50x6 mm, G.I. Channel St Cross arm 1.45Mtr @ 9.2Kg/mtr (8Nos) including top piece
Galvanisation of all RS and MS materials
11 KV Disc Insulator (T & C) 45 KN Polymer
11 KV Hard Ware Fitting(T & C Type) 45KN
Tension Assembly Wedge Type with Anchoring Clamp for 11KV covered conductor
IPC for Covered Conductor 11 KV 100 Sqmm
11 KV Pin Insulator (polymer)
Non metallic ties for 11 kv covered conductor
H.T. Stay set complete
H.T. Stay Insulator
H.T. Stay Clamp (1.9Kg/pair)
7/10 SWG G.I. Wire (Grade-2)
Earthing Support (Coil Type)
No.8 GI wire(dia-4.6mm) 0.131Kg/Mtr, 2Mtr for connecting pole with coil earthing
100mm² AAA Conductor
11KV XLPE COVERED CONDUCTOR 100 SQMM,AAA
PG Clamp for 100mm² AAA Conductor
Fish Plate 50x6mm, 2.36Kg/Mtr, each 0.280Mtr Length
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
GI Bolts, Nuts & Washers of assorted size
Black Paint
Yellow colour paint for back ground
Sunderies (Al Binding tape,Insulation tape, etc.)
CIVIL Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @ 6648.85
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648=Rs.748.00
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
Dismentling Dismantling charges of H.T. Pole
Dismantling charges of HT Line
20.Jhami road 9Mtr long 300Kg PSC Pole
RCC Base plate
1.1KV LT AB Cable 4x50+1x50+1x16
CAP CABLE END FOR ABC 50 SQMM
LT Stay Set (Complete)
LT Stay Insulator
LT Stay Clamp
7/12 SWG GI stay wire
Suspension clamp with Eye hook
Dead End Clamp with Eye hook suitable for XLPE Cable
Pole clamp for Eye Hook (For AB Cable)
Piercing Connector
Neutral Connector
Earthing Support (Coil Type)
No-8 GI wire (Dia 4.6mm) 0.131KG/Mtr - 2Mtr. For connecting pole with coil earthing
Danger Plate
Back clamp for danger plate 25x3mm flat, 0.59Kg/Mtr flat of 0.510mtr 1No
GI 2Ply, 2.5mm dia barberd wire for anticlimbing device
Back clamp for barbed wire anticlimbing device 25x3mm flat, 0.59Kg/Mtr flat of 0.510 mtr length 4Nos/pole
G.I. Nuts and Bolts
Black Paint
Yellow colour paint for back ground
Sunderies
CIVIL Stay concreting in ratio 1:2:4 as per TPSODL specification and drawing = 0.2Cum @ 6648.85=0.2X6648.85=Rs.1329.77
Concreting of 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.375Cum. @ 6648.85
Couping of 11M WPB & 9Mtr/8Mtr Poles in ratio 1:1.5:3 =0.1125Cum. @ 6648.85=0.1125x6648=Rs.748.00
Survey of incremental/delta network and assets changes of 11 kV network and updation in GESW databas
Dismantling Dismantling charges of L.T. Pole
Dismantling charges of L.T Line N:B:. Salvage value @ 8% to be deducted from the contractor's value.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.62 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
DTCN.pdf
Tender Documents • 1.87 MB
BOQ_580795.xls
BOQ • 0.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .