Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.3 LAccepted-AOC 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹93.7 L+₹3.4 L (3.73%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹94.8 L+₹4.5 L (5.03%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹1.0 Cr+₹13.7 L (15.2%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹1.1 Cr+₹15.3 L (17.0%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
18 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commander Works Engineer Hisar
Headquarters Commander Works Engineer Military Engineer Services Hisar, Military Station Hisar Hisar (Haryana)-125006
LEDISATION OF INTERNAL AND EXTERNAL ELECTRIC POINTS IN HISAR MIL STN UNDER GE HISAR
2024_MES_650334_1
CA NO CWE/HSR/43 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Hisar
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹1,000
Yes
GE Hisar
₹2.2 L
Yes
25 Jun 2024
17 Apr 2024
20 May 2024
17 Apr 2024
18 May 2024
11 May 2024
17 Apr 2024 - 18 May 2024
Amount
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
S & F modular switch, 1 way, 6 A, 1 module complete all as specified and as directed.
S & F modular white cover plate with frame, 2 modules complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F including testing LED batten light fitting 1 X 20 watt with aluminium housing and polycarbonate diffuser complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, including dismantling/removing of existing lights complete all as specified and directed. Note: - Rates quoted includes dismantling and nothing will be paid extra on this account.
S & F including testing LED high bay 120 watt luminaire with aluminium die cast housing with mechanical mechanism for mounting, with driver complete suitable for fixation on wall/roof/railings with robust body, corrosion resistant, superior finish. The system wattage of fitting should not be more than 120 watt ± 10%, having surge protection of minimum 4kV internal, power factor more than 0.95, corelated colour temperature should 5700⁰-6500⁰ Kelvin, total hormonic distortion (THD) should not be more than 10%, lumen efficacy should not be less than 130 lumens per watt, total input voltage range 140-270V AC, colour rendering Index should not be less than 70 including, dismantling/removing of existing lights complete all as specified and directed. Note: - (i) Cost of mechanical mountings and holders for lights, nut & bolts are inclusive in this item. (ii) Rates also includes dismantling and removing of existing lights and nothing will be paid extra on this account.
Supply, fixing and testing LED Building security light fitting of 25 Watt complete with robust body, corrosion resistant, superior finish, made in a single piece by high pressure die cast aluminium alloy with corrosion resistant polyester powder coated housing including fixing on wall with 1.2 metre long galvanised iron pipe 40 mm or suitable dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and waterproof with minimum IP66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 Hz, power factor should be more than 0.95 and Total Harmonic Distortion THD(I) less than 10%, corelated colour temperature should 5700⁰-6500⁰ Kelvin. Fitting should be provided with 4 kV surge protection. Driver should have high voltage withstanding capacity upto 300 volt AC. Driver should also have normal phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficacy of LED luminaries system shall be more than 100 lumens per watt. Note for ser Item Nos 5 to 7: - (i) On every fitting CA No. and office name shall be printed by screen printing (min size 20mm x 100mm) and quoted rate shall be deemed to include this factor. (ii) Contractor will arrange its own T&P for any of the schedule work and the rate of the same is deemed to be included in the respective items. (iii) Contractor will provide Certificate from Area Sales manager for purchasing and Genuity of LED Lights. (iv) Contractor will provide safety testing certificate as per IS:10322-2012/2013 all as directed by Engineer-in-charge.
Ashirwad Contractor and Supplier
malik constructions
Leo Network power systems
M/S Hind Constructions
Choice india
RAVI KUMAR
M/S Sulakh Brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .