| 1 | L1₹32.7 LAccepted-AOC 1ST FLOOR GURJEET MARKET DHANGU ROAD | L1 | Accepted-AOC Accepted | |
| 2 | L2₹42.2 L+₹7.3 L (20.9%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
REPAIR / REPLACEMENT OF LT DISTRIBUTION SYSTEM AND CONNECTED ITEMS AT D-1B AREA UNDER AGE E/M-I OF GE (N) MAMUN
2023_MES_575780_1
GE(N)/M-63/2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹80,000
13 Mar 2023
18 Jan 2023
16 Feb 2023
18 Jan 2023
14 Feb 2023
2 Feb 2023
Amount
Dismantling old unserviceable steel poles/Strut any size and shifting n.exceeding 50 meters for setting aside for disposal action all as specified and directed.
Dismantling old unserviceable concrete pole/Strut any size and shifting n.exceeding 50 meters for setting aside for disposal action all as specified and directed.
M&L for erection of steel tubular swaged pole 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting the pole with two coat of synthetic enamel paint over a coat of red oxide primer coat and 30cm thick strip painting in alternate colours upto 1.5m height from coping.
M&L for prestressed cement concrete pole 9 mtr long, 102 mm x 172 mm at top and 102 mm x 289 mm at bottom class-10 complete, erected truly in vertical position and painting the poles with alternate layer of 30 cm, black and yellow paint with with two coats of synthetic enamel paint over a coat of primer upto 1.5 mtr above from the coping complete all as specified and directed.
Dismantling aluminium conductor of LT OH line after unbinding from insulators for replacement/re-stringing of damaged conductors including seggregating serviceable/unserviceable conductors for re-use or for shifting to MES store for taking credit to contractor all as specified and as directed .
Restringing and restretching aluminium conductor on LT OH line with new aluminium binding wire including stretching with 3% sag, re-connecting of all cables, jumpers with binding wire complete all as specified and as directed.
M&L for ACSR conductors of LT OH line including securing with insulators using aluminium binding wire, jointing jumpers etc including all disconnected cables, jumpers with proper binding complete all as specified and as directed.
Dismantling earth wire from LT OH line after unbinding from pole for re-use or for shifting to MES store for taking credit to contractor complete all as specified and as directed.
Restringing and restretching dismantled earth wire from LT OH line including securing with insulators using GI binding wire complete all as specified and as directed.
M&L for Galvanised steel earth wire of service feeder or distributor span of street light poles including binding with cross arm channel using GI binding wire complete all as specified and as directed.
Dismantling cross-arms of M.S. channel or angle sections etc from LT poles complete, setting aside for re-use or shifting to MES store for taking credit to contractor complete all as specified and as directed.
Fixing only cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed ,welding and inclusive of one primer coat, one under coat and one finishing coat with synthetic enamel paint complete all as specified and as directed.
M&L for replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed ,welding and inclusive of one primer coat, one under coat and one finishing coat with synthetic enamel paint complete all as specified and as directed.
Dismantling and taking old/UNSV stay assembly including Stay wire and insulator complete all as specified and directed.
M&L for replacement stay assembly complete with MS stay plate of size 300x300x6mm thick, stay rod 20 mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR Part-I, 2009 complete all as specified and as directed. ( Excavation, PCC, saty wire and loop type insulators will be measured separately)
Dismantling insulators of any type, any size complete all as specified and as directed.
M&L for loop type insulator large size with overall dimensions 90x140 mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified and as directed.
Fixing only shackle type insulators retrieved from item No 16 complete all as specified and as directed.
Fixing only pin type insulators retrieved from item No 16 complete all as specified and as directed.
M&L for shackle type insulator,100 mm height,115 mm dia, 31x5 mm strap,14 mm dia bolts Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, complete all as specified and as directed.
M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed.
Taking out LT aluminium conductor cable,1100 volts grade heavy duty, of size upto 35 Sqmm from trench/cable duct/through wall/pole carefully, removing defective length and stacking aside for re use or for taking credit to contractor all as specified and directed.
All as per Srl Item 22 but of size 50 Sqmm to 95 Sqmm
All as per Srl Item 22 but of size 120 Sqmm to 185 Sqmm
All as per Srl Item 22 but of size 240 Sqmm to 400 Sqmm
Laying only cable of size upto 35 sqmm all as specified and directed.
Laying only cable of size of size 50 Sqmm to 95 Sqmm all as specified and directed.
Laying only cable of size 120 Sqmm to 185 Sqmm all as specified and directed.
Laying only cable of size 240 Sqmm to 400 Sqmm all as specified and directed.
Supply,laying,connecting and testing in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 400 Sqmm 3.5 core with aluminium termination lugs, laid in trench/cable duct/through wall/pole and making good disturbed surface complete all as specified and directed.
All as above mentioned in item No 30 but Size 300 sqmm 3.5 core
All as above mentioned in item No 30 but Size 240 sqmm 3.5 core
All as above mentioned in item No 30 but Size 185 sqmm 3.5 core
All as above mentioned in item No 30 but Size 150 sqmm 3.5 core
All as above mentioned in item No 30 but Size 120 sqmm 3.5 core
All as above mentioned in item No 30 but Size 95 sqmm 3.5 core
All as above mentioned in item No 30 but Size 70 sqmm 3.5 core
All as above mentioned in item No 30 but Size 50 sqmm 3.5 core
All as above mentioned in item No 30 but Size 35 sqmm 3.5 core
All as above mentioned in item No 30 but Size 25 sqmm 4.0 core
All as above mentioned in item No 30 but Size 16 sqmm 4.0 core
All as above mentioned in item No 30 but Size 16 sqmm 2.0 core
All as above mentioned in item No 30 but Size 10 sqmm 2.0 core
M&L for Cable end jointing kit, heat shrinkable, 1100 volts grade complete with jointing material and accessories suitable for 2/3.5/4.0 core XLPE armoured aluminium conductor cable of size 10-16 sqmm size complete all as specified and directed. Note: Cost of excavation,returning filling, taking out cable from trench or any other situation, disconnection and connection etc if required is deemed to be included in the quoted rate.
All as mentioned in item No 44 but size of 25-50 sqmm, 3.5 core
All as mentioned in item No 44 but size of 70-150 sq mm, 3.5 core
All as mentioned in item No 44 but size of 185-240 sq mm, 3.5 core
All as mentioned in item No 44 but size of 300-400 sq mm, 3.5 core
Supplying and fixing in replacement 1100 volts grade heavy duty cable ,10 sq mm, 2 core,flat, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, all as specified and directed.
Supply, connecting and testing XLPE insulated, unarmoured, single core Aluminium conductor cable, extruded PVC type, Outer Sheathed, 1100 V grade of size 95 sqmm as per IS 7098 (Part 1) 1988 with upto date amendments for using on LT OH line to connect ACSR conductors as jumper complete all as specified and as directed.
All as mentioned in item No 50 but 150 sqmm
S&F GI tubing, light grade 25 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately ) including taking down/up existing tubing with fitting of any description complete all as specified and as directed.
All as mentioned in item No 52 but 40 mm bore
All as mentioned in item No 52 but 50 mm bore
All as mentioned in item No 52 but 80 mm bore
All as mentioned in item No 52 but 100 mm bore
S&F MCCB 3 pole 415 volts , fixed type 25 Amps to 100 Amps with breaking capacity 16 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu, have reverse load and line termination,rotary handles, direct and variable depth and common auxiliaries for entire range. CE marked, conforming to IEC-60947-2,Maximum operational voltage 550 VOlts ( Ue)(AC 50/60 Hz), Insulation voltage (Ui) of 800 Volts and rated Impulse withstand voltage (Uimp) not less than 8000 volts. Ambient temperarture of 50 degree centigrade. MCCB operated by a rotary handle with indication the three distinctive position (ON/OFF/TRIPPED) including spreadres for connecting cable after taking out old U/S MCCB all as specified and directed.
All as mentioned in item No 57 but 125 amps
All as mentioned in item No 57 but capacity 160 Amps with breaking capacity 25 KA, thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics = 100% Icu
S&F MCCB, 4 pole 415 volts,160 Amps with breaking capacity 25 KA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu, have reverse load and line termination, rotary handles, direct and variable depth and common auxiliaries for entire range. CE marked,conforming to IEC-60947-2, Maximum operational voltage 550 Volts ( Ue)(AC 50/60 Hz), Insulation voltage (Ui) of 800 Volts and rated Impulse withstand voltage (Uimp) not less than 8000 volts. Ambient temperarture of 50 degree centigrade. MCCB operated by a rotary handle with indication the three distinctive position (ON/OFF/TRIPPED) including spreadres for connecting cable after taking out old U/S MCCB all as specified and directed.
All as mentioned in item No 60 but 200 amps
All as mentioned in item No 60 but 250 amps
All as mentioned in item No 60 but 315 amps
All as mentioned in item No 60 but 400 amps
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as mentioned in item No 65 here in above but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay including necessary form work complete all as specified and directed.
Supply and laying in repairs Double Wall Corrugated pipe, 75 mm dia, SN 8 for drawing electric cable in trench all as specified and directed
Supply and laying in repairs Double Wall Corrugated pipe, 100 mm dia, SN 8 for drawing electric cable in trench complete all as specified and directed.
Supply and laying in repairs Double Wall Corrugated pipe, 135 mm dia, SN 8 for drawing electric cable in trench complete all as specified and directed.
Supply and laying in repairs Double Wall Corrugated pipe, 150 mm dia, SN 8 for drawing electric cable in trench complete all as specified and directed.
Pruning up of tree branches upto 6" girth, 3 mtr all around of LT overhead lines including provision of cutting tools, supports and safety equipments, removing cut branches from site all as directed Note: (i) Distance between two poles shall be measured as one span irrespective of the Nos of trees. (ii) Shut down permission shall be obtained from concerned power house before commencement of pruning.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level)with top edge of earth plate not less than 1.5 meters below ground level connected by 25X4 mm GI strip as earth lead by means of nuts and bolt, thimbles, check nuts, washers of GI or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x 300 mm dia,15 mm thick plaster in CM 1:4 funnel with wire guage mesh ,CI cover 10mm thick hinged to CI frame of 320x320mm size made out of 5mm thick angle iron and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part -1 and specified including provision of GI strip upto 7.5 metre long protected by 40 mm dia medium grade pipe and watering pipe shall be 20 mm bore medium grade , including all excavation and earth work and connecting the earthing to an earthing test point and to main switch board as specified and testing on completion complete all as specified and directed.
Supply & fix in replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking out old strip all as specified and directed.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 220919.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
KULBHUSHAN AGGARWAL
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .