Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-AOC | ₹3.4 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹4.4 Cr+₹97.0 L (28.5%)Rejected-Finance 201 BANSI PLAZA 581 M G ROAD PALASIA INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | ₹4.4 Cr+₹97.0 L (28.5%) | L2 | Rejected-Finance Being L2 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
23 Mar 2022, 5:00 pmClosed
Chief Executive Officer
Sagar Smart City Limited, Sagar Smart City Office, 2nd Floor, ICCC Building, New Collectorate Premises, Sagar, Madhya Pradesh-470002,
SELECTION OF CONTRACTOR FOR ESTABLISHMENT OF CONSTRUCTION AND DEMOLITION WASTE PROCESSING PLANT OF 50 TPD CAPACITY WITH OPERATION AND MAINTENANCE FOR 10 YEARS IN SAGAR CITY UNDER SMART CITY MISSION
2022_UAD_184028_1
2022/SSCL/108
Open Tender
Civil Works - Others
Item Rate
120 days
SAGAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹1.4 L
SAGAR
30 Mar 2022
10 Feb 2022
25 Mar 2022
10 Feb 2022
23 Mar 2022
10 Feb 2022
18 Feb 2022
CIVIL WORKS
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 meter outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete. Moorum/Hard Copra
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. Cement concrete grade M-10 (Nominal Mix) with 20 mm maximum size of stone aggregate
Centering and shuttering including strutting, propping etc.and removal of form for : Foundations, footings, bases of columns, etc. For mass concrete.
Centering and shuttering including strutting, propping etc.and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc.and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire upto floor two level including all wastage etc. complete. Thermo-Mechanically Treated bars.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor two level excluding cost of centering, shuttering, finishing and reinforcement. Cement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate.
Brick work with well burnt chimney bricks in bulls patent trench kiln manifactured by ghol process,crushing strength not less than 40kg /sqcm and water absorption not more than 15% in foundation and plinth. Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with of class designation 40 in super structure above plinth level up to floor 2 level including the cost of scaffolding. Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with modular fly ash lime bricks (FALG Bricks) conforming to IS:12894-2002, class designation 100 average compressive strength in superstructure above plinth level up to floor 2 level including the cost of scaffolding : Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6mm thick cement plaster 1:6 (1 cement: 6 fine sand).
Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work.
Providing and applying 1.0 mm thick white cement based wall putty of best quality, over plastered surface to prepare the surface even and smooth complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes.
Providing corrugated Galvanised sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in orizontal/vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00mm thick with zinc coating not less than 275gm/m²
Construction of Embankment/Sub grade/ earth shoulders, as per clause 305.1.1 inclusive of operation necessary as per clause 305 & its sub-clauses, Where required but with approved materials obtained from excavation for road construction (vide clause 301.3.11) i/c consolidating the original ground by rolling as directed by the Engineer-in-charge but with a maximum of 6 passes of 8-10 tonne roller & i/c compaction and maintenance of surface during construction to ensure shedding & preventing ponding of water (clause 305.3.7), finishing i/c all lifts but excluding scarifying existing granular/bituminous road surface vide clause 305.6.
Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with on prepared surface, mixing by mix in place method at OMC, and compacting with vibratory roller to achieve the desired density, complete in all respect and as per relevant clauses of section-400. for grading- I Material
Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table of MORTH Specifications 600-1, cement content not to be less than 200 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per relevant clauses of section-603.
Construction of dowel jointed, plain cement concrete pavement in M-40 grade concrete over a prepared sub base with 43 or higher grade cement, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plan as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar and tie rod, admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC-15 2002 and as per relevant clauses of section-602 of of MORTH specifications complete but excluding cost of steel in dowel bar & tie rod etc.
Supply of support for overhead line RS joist / H-beam of I.S. standard including welding, drilling of required hole etc. complete as required. H-Beam 152x152mm , Std weight 37.1 kg per meter
Erection of RS Joist pole/'H' beam/steel tubular/steel rail pole of lengt exceeding 10 metres but not exceeding 13 metres in cement concrete M-10 (1 cement:3 core sand: 6 graded stone aggregate 40mm nominal size) base, foundation, muffing including excavation and back refilling etc. as required.
Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above. Energy efficiency level -3 Aluminum wound 200 kVA
Supplying installing and testing of AB isolating switch assembly set gang operated suitable for 11/0.4 KV, DP structure with brass part contacts, operating rod with required GI pipe, handle locking arrangement on On-Off position conforming to IS complete with required material and installing on existing structure to complete the job as required as per specification. 11 kV
Supplying, installing, testing of 11 KV D.O. fuse assembly with brass part contact for 11/0.4 KV DP Structure set of 3 with fuse with barrel with required fuse element & other materials as per specification on existing D.P. structure as required.(set of 3nos.) 11 kV
(i)Supplying, installing, testing and commissioning of LT Distribution Box with TPN isolator of 600 amper on incoming,bus bar and 6 S.P.M.C.C.B.of 120 A" .on outgoing side for 200 KVA transformer
Supplying, installing, testing and commissioning of Lightning Arrestors (i) 11 KV Gapless, line type
Supplying, installing, testing of earth Coil (coil of 115 turns of 50mm dia, and 2.5 Mtrs. Lead of 4 mm G.I wire.
Supplying and drawing of stranded Aluminium Conductor Steel Reinforced (ACSR) confirming to IS:398-1976 of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc. ACSR 6/1 - 4.09mm dia (Raccoon) with equivalent copper area 48 Sqmm (0.075 sq inch) equivalent calculated Aluminium area 77.83 Sq.mm.
Supplying and drawing of stranded Aluminium Conductor Steel Reinforced (ACSR) confirming to IS:398-1976 of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc. ACSR 6/1 - 3.35mm dia (Rabbbit) with equivalent copper area 30Sqmm (0.05 sq inch) calculated aluminium area 52.21Sq.mm.
Supplying and erection of galvanised stay set for 11kV overhead line complete with 19/20mm dia x 1.8 meters long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle (20mmx 600mm), 7/4.00mm dia G.I. stay wire and 11kV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm. nominal size) foundation including excavation and refilling etc. as required.
Supplying and erection of 11kV pin insulator complete with large steel head G.I. pin, nut, washer etc. as required.
Supplying and erection of 11kV disc insulator for 11kV overhead lines with galvanised insulator fittings, ball and socket type, and complete with galvanised strain clamp,bolts,nuts washer etc. as required.
Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt ) complete as required.
Earthing with Copper Earth plate 600mm X 600mm X 3mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt) complete as required.
Add Extra for using salt and charcoal / coke for G.I. Plate or Copper plate earth electrode as required including excavation & refilling.
Providing and fixing 25mm X 4mm G.I. strip on surface or in recessed/concealed for connection etc. as required.
Providing and laying copper tape 32mm X 6mm thick for earth electrode directly in ground as required
Supplying and laying G.I. earth lead duly installed on wall or in G.I. Pipe including connections etc complete as required 13 sq mm ( 4 mm dia )
Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per specification
Supply of Hand Gloves 33KV Tested
Supply of Fiber Discharge Rod I/C Connection copper Lead Tested
Supply of shock instruction chart duly framed with glass, as required.
Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric sub-station including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided up to 2.00 mt. apart or as required .The panel frame with required angle iron/ flat iron members /cross members including mesh welded in frame panel, shall be erected between the post. The angle iron post shall be erected in cement concrete 1:2:4 ( 20 mm graded metal ) foundation, including excavation of pit and refilling the same . The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade
PVC sleeve RYB
L.T. Distribution Box for 200 KVA Tranformer (600 A. Isolator and 9 SP MCCB of 120 A.).
Supply of XLPE Insulated power cable (conforming IS-7098) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor UNARMOURED 3½ CORE 150 Sq.mm.(XLPE)
Supply of XLPE Insulated power cable (conforming IS-7098) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor UNARMOURED 3½ CORE 300 Sq.mm.(XLPE)
LT trivector Energy Meter, DLMS Compliant category-A(for Substatio/Feeder Metering), 3 Phase 4 wire, 440 Volts, 5 Amp, accuracy class 0.5S with GSM (GPRS Compatible) Modem with Box.
Anti Climbing Device (Barbed Wire 3.5 Kg) GS 2.5 mm Dia (12SWG)
Primer coat over new steel and other metallic surface with red oxide/zinc chromide paint complete with supply of material labour etc. including preparation of surface.
Primer coat with aluminium paint, brushing complete with material and labour including preparation of surface.
Supplying and fixing of LT Panel accessaries of approved make in existing LT Panel including connections etc.as required as per spececification. Frequency Meter
Supplying and fixing of LT Panel accessaries of approved make in existing LT Panel including connections etc.as required as per spececification. Aluminium bus bar strips with PVC sleeves
Supplying and fixing of LT Panel accessaries of approved make in existing LT Panel including connections etc.as required as per spececification. LED lamps
Supplying and erection of 30A aerial fuse complete as required.
MCCB with Breaking Capacity 35 KA at 415 V. Current Rating -400 Amps & Adjustable: 70% -100% thermal & 4- 10 times magnetic setting
MCCB with Breaking Capacity 35 KA at 415 V. Current Rating -200 Amps & Adjustable: 70% -100% thermal & 5- 10 times magnetic setting
MCCB with Breaking Capacity 35 KA at 415 V. Current Rating -160 Amps & Adjustable: 70% -100% thermal & 5- 10 times magnetic setting
MCCB with Breaking Capacity 25 KA at 415 V. Current Rating -25 to100 Amps & 70% -100% adjustable
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- FOR TRIPLE POLE (TP). 6 Amp to 32 Amp Rating
Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :- SINGLE POLE (SP). 6 Amp to 32 Amp Rating
Supply, installation, testing & commissioning of LT trivector energy meter, DLMS compliant category-A (for substation/feeder metering) , 3 phase 4 wire, 440 Volts, 5 Amp, accuracy class 0.5S with GSM(GPRS compatible) modem suitable for required C.T. 5A duly tested from electricity board with uPVC box .
Supplying and fixing MNx 32Amp
Supplying and fixing MNx 25Amp
Supplying, Fixing and Testing of mixed die-electric ultra heavy duty APP capacitor 440 Volt, 3 Ph., peak inrush current upto 500 x In, over current upto 3 x In(normal current), operating losses total not more than 0.35 W / KVAr, operating life not less than 300000 hrs, switching 20000 operation / year, as per IS:13340-1993, IS:133411992, IS:13585-1994, of approved make as required as per specification 5 to 25 KVAr bank
ON/OFF push button with WL ring
Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 3½ CORE. 240 Sq.mm.(XLPE)
Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 3½ CORE. 150 Sq.mm.(XLPE)
Supply of XLPE Insulated power cable (conforming IS- 7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductor. ARMOURED 4 CORE. 16 Sq.mm.(XLPE)
Cable Laying of one number PVC Insulated and PVC sheathed power cable of 1.1.kV grade of size exceeding 120 Sq mm but not exceeding 400 Sq.mm direct in ground including excavation and cushioning protective covering and refilling the pit etc. as required.
Cable Laying of one number additional PVC insulated and PVC sheathed power cable of 1.1kV grade of size exceeding 120 Sq mm but not exceeding 400 Sq mm direct in ground in the same trench in one tier horizotal formation including excavation, send cushioing, protective covering and refilling the pit etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed aluminium conductor cable of 1.1kV grade of size not exceeding 25 Sq.mm on surface etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed aluminium conductor cable of 1.1kV grade of size exceeding 120 Sq.mm but not exceeding 300 Sq.mm on surface etc. as required.
BRASS COMPRESSION GLAND Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland Size 70mm 3 x 240 Sq.mm 3½ x 300 Sq.mm
BRASS COMPRESSION GLAND Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland Size 50 mm 3½ x 150 Sq.mm 3 x 185 Sq.mm
BRASS COMPRESSION GLAND Supplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete. Gland size 28mm for 3,4 x 16 Sq.mm
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size-300 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 240 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 150 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 95 Sq.mm.
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 70 Sq.mm
LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.For Conductor Size- 6mm to 16 Sq.mm
Supplying Route Marker with 10cm x 10cm G.I. Plate 5mm. Thick with Inspection thereon bolted/welded to 35mm x 35mmx 6mm angle iron 60cm long and fixing the same in ground as required
Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt ) complete as required.
Point Wiring in surface rigid P.V.C. conduit system with Flush type Accessories. Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- Light Point/Fan Points. a) Short point
Point Wiring in surface rigid P.V.C. conduit system with Flush type Accessories. Point wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :- Light Point/Fan Points. a) Long point
Circuit Wiring Wiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) of ISI marked suitable size including painting etc. as required as per specification a) 2x2.5 Sq.mm.
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH MODULAR ACCESSORIES Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for :- Short Point
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH MODULAR ACCESSORIES Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for :- Medium Point
POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH MODULAR ACCESSORIES Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (MMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for :- Long Point
32 mm dia ISI marked, PVC conduit
Supplying,Fixing and Testing of Flourescent Tube rod T-5 ISI marked of approved make as required as per specification 28 watt T-5
Supplying and fixing down rod of MS pipe for ceiling fan including threading, painting, making holes etc. as required complete :-
Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS :374/1979 with upto date ammendments. Ceiling Fan (Energy Saver 60 W)-1400 mm Sweep
Supplying, erecting and testing of approved make Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished and as required. 450mm sweep 900 RPM
FIRE FIGHTING WORK
Supplying & fixing of fire extinguisher/refills as per IS specification. ABC type duly refilled 6 Kg & ready to use
Supplying & fixing of Fire Extinguisher/Refills as per IS specification 4 buckets set with sand, self supported M.S.stand i/c shed duly painted with red colour as per IS
CAMERA
2 MP IP IR eyeball camera with H.264 video compression Supply, Installation testing and commissioning of the IP dome camera shall be equipped with a 1/2.8 2 MP progressive scan CMOS imager to capture full HD 1080p (25/30 fps) images, a 3.6 mm fixed lens, and a waterproof (IP66) enclosure. As a true day/night solution, the camera shall use smart IR technology and provide up to 98 ft (30 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:-0.1 lux @F1.2, AGC ON, 0 lux with IR video compression :- H.264, noise reduction: 3DNR,backlight compensation :- BLC/HLC/DWDR, encode mode:- CBR/VBR (freely adjustable in CBR, 5 levels in VBR). UL listed
8 channel NVR with 1 SATA Supply, installation testing and commissioning of 8CHnetwork video recorder with real-time recording: up to 4 MP resolution live view, preview and playback/up to 8 channels at 1080p,withinbuilt PoE, up to 1TB supports complete with UL certification
Hard disk Providing &fixing of 2 TB hard disk
CCTV colour monitor Supply, installation, testing and commissioning of 32" flat LED colour monitors.
MACHINERY
Design, Engineering, supply & Installation of Plant & Equipment including Technological Structures of Construction & Demolition waste recycling plant. Including (Weigh Bridge, Primary Feeder and hopper, Horizontal Single Deck Screen dry type, Secondary Hopper and Vibratory Feeder, 3 deck Screen (Wet Screen), Jaw Crusher, Log washer, Hydro cyclone with Dewatering Screen, Rinsing Single Deck Wet Screen, Thickener with Flocculent Dosing Station, Water Recycle Tank, Pumps, Conveyers, Pipelines).
Tile Plant
VATS REAL TECH PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .