| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹26.8 L+₹59,020 (2.25%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹27.0 L+₹76,239 (2.91%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹37.5 L+₹11.3 L (43.0%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹38.2 L+₹12.0 L (45.6%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 bidder |
| Sl No | Description | Qty | Unit | KRISHNA ENGINEERING ENTERPRISES L2 | M/S JIWAN SINGH L1 | M/s Chopra Constructions L5 | M/S AKHILESHWAR ASSOCIATES L4 | narayan construction L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of overhead ACSR conductor of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse serviceable ACSR in the work & removing unserviceable conductor from site, complete all as specified & as directed. | 6 | Qtl | 100 ₹600 | 20 ₹120 Lowest | 50 ₹300 | 210 ₹1,260 | 200 ₹1,200 |
| 2.00 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified & as directed. | 1,200 | RM | 540 ₹6,48,000 Lowest | 620 ₹7,44,000 | 710 ₹8,52,000 | 550 ₹6,60,000 | 550 ₹6,60,000 |
| 3.00 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as specified & as directed. | 300 | RM | 256 ₹76,800 | 245 ₹73,500 Lowest | 280 ₹84,000 | 250 ₹75,000 | 280 ₹84,000 |
| 4.00 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified & as directed. | 3,025 | RM | 180 ₹5,44,500 Lowest | 182 ₹5,50,550 | 210 ₹6,35,250 | 200 ₹6,05,000 | 185 ₹5,59,625 |
| 5.00 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete all as specified & as directed. | 760 | RM | 70 ₹53,200 Lowest | 90 ₹68,400 | 110 ₹83,600 | 125 ₹95,000 | 115 ₹87,400 |
| 6.00 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified & as directed. | 980 | RM | 55 ₹53,900 Lowest | 80 ₹78,400 | 100 ₹98,000 | 115 ₹1,12,700 | 60 ₹58,800 |
| 7.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm for laying of cable and foundation of poles stays and getting out in soft / loose soil, complete all as specified & as directed. | 1,566 | Cum | 80 ₹1,25,280 | 65 ₹1,01,790 | 85 ₹1,33,110 | 250 ₹3,91,500 | 60 ₹93,960 Lowest |
| 8.00 | Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick (soil), complete all as specified & as directed. | 907.36 | Cum | 10 ₹9,073.6 Lowest | 10 ₹9,073.6 Lowest | 10 ₹9,073.6 Lowest | 104 ₹94,365.44 | 10 ₹9,073.6 Lowest |
| 9.00 | Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified & as directed. | 658.64 | Cum | 10 ₹6,586.4 Lowest | 10 ₹6,586.4 Lowest | 10 ₹6,586.4 Lowest | 240 ₹1,58,073.6 | 10 ₹6,586.4 Lowest |
| 10.00 | M & L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed.
Note: Punned thickness of sand shall be measured. | 469.8 | Cum | 380 ₹1,78,524 | 200 ₹93,960 Lowest | 300 ₹1,40,940 | 1,500 ₹7,04,700 | 280 ₹1,31,544 |
Tender Value
₹48.1 L
EMD Value
₹96,200
Closing Date
22 Jul 2025, 6:00 pmClosed
GE 862 EWS
GE 862 EWS PIN-913862 c/o 56 APO
SPL REPAIR TO LT OH LINE TO LT UG CABLE FROM POWER HOUSE TO ADS BUTALIYA GATE SUPPLY AREA AND SPL REPAIR TO UG LT ELECTRIC LINES WITH CABLES AT ADHOC TRANSIT FACILITY NARIAN AT NAUSHERA UNDER AGE EM OF GE 862 EWS
2025_MES_716299_1
GER-42/2025-26
Open Tender
Civil Works
Works
120 days
GE 862 EWS
As per Tender Document
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹96,200
10 Sept 2025
23 Jun 2025
25 Jul 2025
23 Jun 2025
22 Jul 2025
8 Jul 2025
Amount
Dismantling of overhead ACSR conductor of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse serviceable ACSR in the work & removing unserviceable conductor from site, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 2 core, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sq mm 2 core, complete all as specified & as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm for laying of cable and foundation of poles stays and getting out in soft / loose soil, complete all as specified & as directed.
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick (soil), complete all as specified & as directed.
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified & as directed.
M & L for sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable, complete all as specified and directed. Note: Punned thickness of sand shall be measured.
Supply and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified & as directed.
Supply & Laying in GI tubing light grade of 80 MM with necessary fittings as in cable protection in trenches/fixed on wall / floor including necessary clamps bolts and nuts complete all as specified and as directed.
Supply, installation, testing and commissinoning LT Feeder piller box outdoor type 1.0mx1.0mx0.6m suitable for working on 3 phase ,4 wire ,415 volts AC, 50Hz ,outdoor cubical type, and tested at CPRI, Outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 x 50 x 6mm frame, with front & back open, double door system lockable, inner shell shall be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof, entry holes for incoming & outgoing cables as approved by GE including taking down of old LT Panel. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following:-
Incoming MCCB (a) MCCB 250 Amp,4 pole, 50 HZ,415 V having rupturing capacity 35 KA-01 Nos as incoming (thermal magnetic) release and adjustable on load. Outgoing MCCB (a) MCCB 200 Amp,4 pole, 50 HZ,415 V having rupturing capacity 35 KA-01 Nos as outgoing (thermal magnetic) release and adjustable on load. (b) MCCB 100 Amp,4 pole, 50 HZ,415 V having rupturing capacity 25 KA-04 Nos as outgoing (thermal magnetic) release and adjustable on load. (c )MCCB 4 pole 40 amps - 0 2 Nos. (d) Digital voltmeter (0-500) & Digital Ammeter (0-100) Amps with suitable CTs. (e) LED phase indication lamps RYB-01 set ( f) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade and Cupper Bus Bar including Painting etc. (g) Copper bus bar ,TPN 400 Amp rating -04 Nos Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 nos legs of 50 mm x 50 mmx6mm & 60 cm height for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclosure made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02) Nos LT size 20 cmx 15 cm shall be fixed on the panel. (iv) Panel shall be from CPRI approved make. (v) make of panel and drawing shall be approved from GE before placing order for procurement.
Supply, installation, testing and commissinoning LT Feeder piller box outdoor type 1.0mx1.0mx0.6m suitable for working on 3 phase ,4 wire ,415 volts AC, 50Hz ,outdoor cubical type, and tested at CPRI, Outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 x 50 x 6mm frame, with front & back open, double door system lockable, inner shell shall be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof, entry holes for incoming & outgoing cables as approved by GE including taking down of old LT Panel. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following:-
Incoming MCCB (a) MCCB 160 Amp,4 pole, 50 HZ,415 V having rupturing capacity 35 KA-01 Nos as incoming (thermal magnetic) release and adjustable on load. Outgoing MCCB (a) MCCB 100 Amp,4 pole, 50 HZ,415 V having rupturing capacity 25 KA-01 Nos as outgoing (thermal magnetic) release and adjustable on load. (b) MCCB 63 Amp,4 pole, 50 HZ,415 V having rupturing capacity 25 KA-02 Nos as outgoing (thermal magnetic) release and adjustable on load. (c )MCB SPN 63 amps -05 Nos. (d) Digital voltmeter (0-500) & Digital Ammeter (0-100) Amps with suitable CTs. (e) LED phase indication lamps RYB-01 set ( f) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade and Cupper Bus Bar including Painting etc. (g) Copper bus bar ,TPN 400 Amp rating -04 Nos Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 nos legs of 50 mm x 50 mmx6mm & 60 cm height for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclosure made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02) Nos LT size 20 cmx 15 cm shall be fixed on the panel. (iv) Panel shall be from CPRI approved make. (v) make of panel and drawing shall be approved from GE before placing order for procurement.
Supply, installation, testing and commissinoning LT Feeder piller box outdoor type 1.0mx1.0mx0.6m suitable for working on 3 phase ,4 wire ,415 volts AC, 50Hz ,outdoor cubical type, and tested at CPRI, Outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 x 50 x 6mm frame, with front & back open, double door system lockable, inner shell shall be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof, entry holes for incoming & outgoing cables as approved by GE including taking down of old LT Panel. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following:-
Incoming MCCB (a) MCCB 250 Amp,4 pole, 50 HZ,415 V having rupturing capacity 35 KA-01 Nos as incoming (thermal magnetic) release and adjustable on load. Outgoing MCCB (a) MCCB 200 Amp,4 pole, 50 HZ,415 V having rupturing capacity 25 KA-02 Nos as outgoing (thermal magnetic) release and adjustable on load. (b) MCCB 63 Amp,4 pole, 50 HZ,415 V having rupturing capacity 25 KA-01 Nos as outgoing (thermal magnetic) release and adjustable on load. (c )MCB SPN 63 amps -2 Nos. (d) Digital voltmeter (0-500) & Digital Ammeter (0-100) Amps with suitable CTs. (e) LED phase indication lamps RYB-01 set ( f) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade and Cupper Bus Bar including Painting etc. (g) Copper bus bar ,TPN 400 Amp rating -04 Nos Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 nos legs of 50 mm x 50 mmx6mm & 60 cm height for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclosure made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02) Nos LT size 20 cmx 15 cm shall be fixed on the panel. (iv) Panel shall be from CPRI approved make. (v) make of panel and drawing shall be approved from GE before placing order for procurement.
Supply, installation, testing and commissinoning LT Feeder piller box outdoor type 1.0mx1.0mx0.6m suitable for working on 3 phase ,4 wire ,415 volts AC, 50Hz ,outdoor cubical type, and tested at CPRI, Outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50 x 50 x 6mm frame, with front & back open, double door system lockable, inner shell shall be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof, entry holes for incoming & outgoing cables as approved by GE including taking down of old LT Panel. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, and consisting of following:-
Incoming MCCB (a) MCCB 250 Amp,4 pole, 50 HZ,415 V having rupturing capacity 35 KA-01 Nos as incoming (thermal magnetic) release and adjustable on load. Outgoing MCCB (a) MCCB 100 Amp,4 pole, 50 HZ,415 V having rupturing capacity 25 KA-03 Nos as outgoing (thermal magnetic) release and adjustable on load. (b) MCCB 63 Amp,4 pole, 50 HZ,415 V having rupturing capacity 25 KA-01 Nos as outgoing (thermal magnetic) release and adjustable on load. (c )MCB SPN 40/ 63 amps-2 Nos. (d) Digital voltmeter (0-500) & Digital Ammeter (0-100) Amps with suitable CTs. (e) LED phase indication lamps RYB-01 set ( f) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade and Cupper Bus Bar including Painting etc. (g) Copper bus bar ,TPN 400 Amp rating -04 Nos Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 nos legs of 50 mm x 50 mmx6mm & 60 cm height for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclosure made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02) Nos LT size 20 cmx 15 cm shall be fixed on the panel. (iv) Panel shall be from CPRI approved make. (v) make of panel and drawing shall be approved from GE before placing order for procurement.
Supply, install,testing and commissioning of factory made bus bar chamber panel of size 600mm x900mmx350mm(CPRI approved outdoor type 3.15 mm qith four strips 200 Amps bus bar aluminium with MCCB 100 Amp -02 nos ,FP 16 KA adjustable type duly connected to aluminium strip at incoming side with suitable space for 2 incoming cable and outgoing of cable 2 cable bus bar fixed on insulators in zig zag position,clearance in each strip and clearance in both side should not be less than 125mm with sufficient working space,height of bus bar chamber not less than 1 mtr, mounted on MS angle 50 x50x6mm made of CRCA sheet 2mm thickoutdoor type powder coated after seven tank process both side opening shutter in two parts,cable opening from bottom side with indicators RYB hinges through out the length of shutter with half turn locking arrangements including grounting in PCC, including taking down old bus bar chamber complete all as directed.
M&L for FRP junction box of size 30X25X15cm, four strip aluminium bus bar of capacity 63 Amps mounted on epoxy insulators weather proof, MCB SP 6 Amps -01 No including provision for fixing to electric poles with 02 Nos MS clamps of flat 40 x 6mm suitable size complete with nuts & bolts making connection with cable & including thimbles at suitable size, complete all as specified & as directed.
Supply and fixing twin core copper flexible cable for connection of security lights of 1.5 sq mm from junction box to security lights, complete all as specified & as directed.
S & F in repair of Street light bracket made out of 32 mm dia GI light grade pipe 1.2 mtr long bend to shape 120 degree and duly fixed alongwith existing pole/bldg with the help of 2 Nos of MS clamp of sizes 32x3 mm including suitable size of bolt ,nuts, and washers, complete all as specified & as directed.
M&L in replacement for earthing complete with steel earth plate eletrode 60cmx60cmx6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts,check nuts and washers etc including protection pipe 40mm bore GI light grade up to 7.5m length, provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts, bolts, earthing shall be done all as per shown electrical plate No 3 of SSR part 1 Including neccessary excavation in soft disintergrated rock and provision of 15mm dia GI pipe light grade with funnel, PCC earth chamber of 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of GE, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core, complete all as specified & as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as specified & as directed.
Supply, installation, testing and commissinoning LT panel board of size 1.5mx1.5mx0.6 m suitable for working on 3 phase ,4 wire ,415 volts AC, 50Hz ,outdoor cubical type, and tested at CPRI for rupturing capacity upto 25KA, Outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle iron frame duly powder coated of size 50x50x6 mm frame, with front & back open, double door system lockable, inner shell shall be made out of 2.0 mm thick CRCA sheet and completely vermin & dust proof, entry holes for incoming & outgoing cables including Glands as approved drawing before manufacturing of Panel by GE including taking down of old LT Panel. Panel shall have bus bar chamber and switch gear compartment, hinged door with rubber gasket, earthing terminals, bus bar capacity 400 amps and consisting of following:-
Incoming MCCB (a) 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA Nos-01 Outgoing MCCB (a) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA. Nos- 02 (b) MCCB 40 Amps, 4 pole with rupturing capacity 16 KA ,415 V ,50 HZ Nos -02 (c) Digital voltmeter (0-500) & Digital Ammeter (0-100) Amps with suitable CTs. (d) LED phase indication lamps RYB-01 set (e) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade and Cupper Bus Bar including Painting etc. (f) Copper bus bar ,TPN 400 Amp rating -04 Nos Notes: (i) Rates are deemed to be inclusive of PCC platform of suitable size of 45 cm height and 04 nos legs of 50 mm x 50 mmx6mm & 60 cm height for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclosure made up of 3.15mm thick CRCA sheet. (iii) Danger notice plate (02) Nos LT size 20 cmx 15 cm shall be fixed on the panel. (iv) Panel shall be from CPRI approved make. (v) make of panel and drawing shall be approved from GE before placing order for procurement.
KRISHNA ENGINEERING ENTERPRISES (BID ID -3359400)
narayan construction (BID ID -3356520)
M/S AKHILESHWAR ASSOCIATES (BID ID -3359254)
M/s Chopra Constructions (BID ID -3366909)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .