| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC LOKMAT BHAWAN A WING 808 WARDHA ROAD RAMDASPETH NAGPUR 440010 | NAGPUR | MAHARASHTRA | 440010 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹7.2 L+₹6,251 (0.88%)Rejected-AOC | L2 | Rejected-AOC Not being the lowest | |
| 3 | L3₹7.4 L+₹34,277.33 (4.83%)Rejected-AOC | L3 | Rejected-AOC Not being the lowest |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
7 Jul 2023, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg No. P-51, 44 wing Air Force Station, Sonegaon, Nagpur 440 005
PROVN OF TEMPORARY STORAGE SHED NEAR MES OFFICE AT AF STN SONEGAON, NAGPUR
2023_MES_602568_1
8456/E8
Open Tender
Civil Works
Item Rate
180 days
Sonegaon
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF Sonegaon
₹19,200
Yes
7 Aug 2023
10 Jun 2023
12 Jul 2023
10 Jun 2023
7 Jul 2023
24 Jun 2023
10 Jun 2023 - 17 Jun 2023
Amount
Surface dressing not exceeding 15cm deep in soft/ loose soil complete all as specified and directed.
M&L for providing PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling mass concrete complete all as specified and directed.
Excavation over areas in soft/ loose soil n. exc. 1.50m deep and getting out complete all as specified and directed.
Excavation over areas in soft/ loose soil exc. 1.50m and n. Exc 3.00 deep and getting out complete all as specified and directed.
M&L for 100mm thick sand bed under sub base of foundation complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in soft/loose soil complete all as specified and as directed.
Removing excavated soil exceeding 250m and not exceeding 500m and depositing where directed complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for hardcore of broken stone or boulders of gauge not exceeding 63mm,deposited, spred and levelled in layer not exceeding 15cm thick, watered and rammed to true surface complete all as specified and as directed.
M&L 75mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L for providing RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., and mass concrete complete all as specified and directed.
M&L for providing RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in chajjas complete all as specified and directed.
M&L for providing RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in ramps and as in coping, channels, water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc. complete all as specified and directed.
Use and waste of formwork to foundations, fillings, bases of columns, rafts & raft beams, sides & soffits of foundation & plinth beams and similar works; vertical or batter for rough finished surface of concrete complete all as specified and as directed.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, including supports, overhangs, etc. also splays between floors and beams complete of flat rough finished surfaces of concrete all as specified.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and as directed.
S&F105X60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
S&F 2nd class hardwood plain framed panelled shutters 35mm thick, (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
S&F mild steel butt hinge, medium weight cold rolled 100mm size all as specified and directed.
S&F in extruded aluminium alloy handle cast type anodised 150mm size all as specified and directed.
S&F aluminium alloy anodised sliding door bolts 300mm long with hasp, staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded sections complete all as specified and directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed.
S&F figured glass 4mm thick quality pin head type and glazing with oil putty in sequence not exceeding 0.5 sqm in each pane complete all as specified and as directed.
M &L for PCC 1:3:6 type C1 (Using 20mm graded stone aggregate) as in block for hold fast block or similar work and finished the surface with existing and including form work complete all as specified and as directed.
M&L for Fe 410-W (Gde-E- 250) quality-A Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.complete all as specified and as directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. Fe 410-w (Gde-E-250)quality A complete all as specified and directed.
S&F 16mm to 20mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and not exc 15cm long complete all as specified and directed.
S&F framed work such as grills, gratings etc., with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks & similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8, type D2, using 40mm graded stone aggregate as in sub base of flooring all as specified and as directed.
M&L for 100mm thick PCC 1:3:6, type C2, using 40mm graded stone aggregate as in sub base of flooring all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base 20mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick on vertical surfaces such as skirting/dados including back coat of plaster in CM 1:3 10mm thick complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 metre mean radius with modular size bricks built in CM 1:6 all as specified and as directed.
M&L rendering 15mm thick in cement mortar (1:6) with sagol finish on fair faces of brick/ concrete surface and the surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering in Cement Mortar 15mm thick in two coats, i.e, in Cement Mortar 1:4, 5mm thick mixed with liquid water proofing compound as per manufacturers' instructions over in Cement Mortar 1:6, 10mm thick on fair faces of brick/concrete surfaces, finished even and fair externally all as specified and as directed. Note: WPC will be measured and paid separately.
M&L preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
Material and labour for applying three coats of white wash on walls including preparation of newly plastered surfaces all as specified and as directed.
M&L preparation of new steel surfaces of any description not otherwise described over 10cm girth or width and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparing new surfaces of wood of any description not otherwise described over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed.
S&f pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Supply only liquid water proofing compound
M&L for concealed point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20mm bore with conduit accessories concealed in wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light/ fan point controlled by one switch.
One three pin 5 Amps switch socket outlet on independent board
Supply and fix switch piano, flush type, single pole, one way, 5 Amps, 230 volts all as specified and directed.
S&F ceiling rose surface backlite, 65x50mm, three terminals, 5 Amps,240 Volts AC complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal complete all as specified and directed.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories tube,driver,with surge protector complete wired with multistranded copper cable & connecting to ceiling rose with 3 core ,multistranded flexible copper cable complete all as specified and directed. Make CGCta No-CCS-100-20-65-HL2-DP-NWH/Havells/ philips/ Bajaj.
S & F 20 Watt LED Bldg security light with a nominal system. The luminaire shall have rated system lifetime of 50,000 burning hours at L70. The luminaire should have cool white colour temperature (CCT>5000K) and a CRI>70. The luminaire shall meet IP66 rating with THD<20% & pf>0.9. The luminaire housing should be made of pressure die cast aluminimum. The total power consumption should not exceed 25W (including driver) pre wired fitted on and including two Nos PVC block of suitable size and connection up to tube light fitting with connecting up with copper 3 core flexible cord of minimum size 0.5 Sqmm and testing complete including LED lamp complete all as specified and as directed. Make : BAJAJ ENXT P 24L WH CR PC SD or its equivalent in Wipro, Bajaj, Philips, Shakti
Supply, fix, connecting and testing factory made, MCB distribution board (MCB DB), IP 38, SPN, 4 way, 240 Volts, single door, flush type made out of 1.2mm thick CRCA sheet metal, Phosphatised, duly powder coated and conforming to IS 13032 with 200 Amps rated bus bar, neutral link, earth bar and din rail etc. complete fixed in switch board/ wall complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, fix, connecting and testing MCB single pole and neutral (MCB SPN), 32Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
Supply, fix, connecting and testing MCB single pole (MCB SP), 6 to 32Amps, 240 volts of rupturing capacity 10kA, C curve type complete all as specified and directed.
Removal of excavated materials to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply, lay / spread in trenches clean dry sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and as directed. Note : Punned thickness only will be considered for payment.
Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 115 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed.
Supplying & laying GI Tubing 40 mm dia Light grade pipe with connecting acessories complete in trench for road and on surface/,wall for protection complete all as specified and directed.
Earthing with galvanised iron earth plate electrode 600 x 600 mm & 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal GL) with top of earth plate not less than 1.5 metre below GL connected to GI earth lead wire 4 mm dia connected to earth plate electrode by means of GI nuts, bolts & washers earth wire protected with & including 15 mm dia medium grade ISI marked GI pipe not less than 7.5 metre long all as shown in electrical plate No. 3 MES Schedule Part 1, with & including ; PCC 1:3:6 type B1 reinforced with welded steel wire fabric not less than 4 Kg per Sq M, watering arrangements with 20 mm GI medium grade pipe ISI marked , GI funnel with GI mesh, filling with mixture of common salt & charcoal, necessary excavation and earth work in any type of soil, including test point, testing & commissioning, complete all as specified and as directed. Note : On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost to the Government. GI earth wire with GI pipe protection beyond 7.5 metre measured & paid separately
Supply and lay in trenches/drawn through pipes or in road crossings / paths/ drains / ducts / floors / along poles / equipments etc., of LT cable under ground, XLPE insulated, screened, PVC bedded, galvanised strip or wire armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade of cross sectional area 10 Sqmm 2 core including connecting up using suitable size aluminium lugs testing and commissioning complete all as specified and as directed. Note : Excavation , earth work, sand cushioning and brick protection shall be measured and paid separately.
chronicle enterprises
PURVA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .