Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹19.6 L+₹90,571 (4.85%)Rejected-Finance | L2 | Rejected-Finance NOT A LOWEST BID | |
| 3 | L3₹19.9 L+₹1.3 L (6.73%)Rejected-Finance | L3 | Rejected-Finance NOT A LOWEST BID | |
| 4 | L4₹20.7 L+₹2.0 L (10.7%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L4 | Rejected-Finance NOT A LOWEST BID | |
| 5 | L5₹22.0 L+₹3.3 L (17.7%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L5 | Rejected-Finance NOT A LOWEST BID |
Tender Value
₹29.6 L
EMD Value
₹59,200
Closing Date
10 Apr 2021, 6:00 pmClosed
GE MH AND RH KIRKEE
GE MH RH KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
MAINT REPAIR AND RENEWAL OF INT ELECT WIRING INCL CERTAIN CONNECTED WORKS OF OTM ACCN AT AUNDH MIL STN UNDER GE MH AND RH KIRKEE
2021_MES_430272_1
8192/E8
Open Tender
Civil Works
Item Rate
270 days
KIRKEE AND AUNDH
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹59,200
Yes
7 May 2021
12 Mar 2021
12 Apr 2021
12 Mar 2021
10 Apr 2021
26 Mar 2021
12 Mar 2021 - 19 Mar 2021
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. all as specified and as directed.
M & L for point wiring complete with and including 1.5 sqmm (nominal area) single core multi stranded copper conductor PVC insulated unsheated FRLS cable 1100 Volts for Phase, Neutral and earth drawn in to and including ISI marked PVC rigid metallic / non metallic on open surface conduit with suitable clamps etc of suitable size including its accessories such as tee, bend ,elbow, socket complete and making good the disturbed surfaces, MS terminal box sunken to wall for housing Modular / piano type switches ,sockets,regulators etc complete all as directed and as specified for the One light point controlled by one switch
All as per item No 2 above but One Fan point controlled by one switch
All as per item No 2 above but One 5 pin 6 Amps socket outlet on independent board.
All as per item No 2 above but One 5 pin 6 Amps socket outlet on same board.
All as per item No 2 above but bell /buzzer point controlled by one push button on the same board with other switches or indipendent with cables 1.5 sqmm size.
All as per item No 2 above but one light point controlled by two way switch.
All as per item No 02 here-in-before but wiring with 2.5 sqmm single core multi stranded copper conductor 1100 v grade PVC insulated unsheathed FRLS cable 1100 volts grade for 16 Amps power point on independent board complete all as specified and directed by Engr-in-charge.
All as per item No 2 here-in-before but wiring with 4.0 sqmm single core multi stranded copper conductor 1100 v grade PVC insulated unsheathed FRLS cable 1100 volts grade for geyser on independent board complete all as specified and directed by Engr-in-charge.
M & L for point wiring complete with and including 1.5 sqmm (nominal area) single core multi stranded copper conductor PVC insulated unsheated FRLS cable 1100 Volts for Phase, Neutral and earth drawn in to and including ISI marked PVC rigid metallic / non metallic on existing concealed conduit with suitable clamps etc of suitable size including its accessories such as tee, bend ,elbow, socket complete and making good the disturbed surfaces,MS terminal box sunken to wall for housing Modular / piano type switches ,sockets,regulators etc complete all as directed and as specified for the One light point controlled by one switch
All as per item No10 above but One Fan point controlled by one switch
All as per item No10 above but One 5 pin 6 Amps socket outlet on independent board.
All as per item No10 above but One 5 pin 6 Amps socket outlet on same board.
All as per item No10 above but bell /buzzer point controlled by one push button on the same board with other switches or indipendent with cables 1.5 sqmm size.
All as per item No10 above but one light point controlled by two way switch.
All as per item No 10 here-in-before but wiring with 2.5 sqmm single core multi stranded copper conductor 1100 v grade PVC insulated unsheathed FRLS cable 1100 volts grade for 16 Amps power point on independent board complete all as specified and directed by Engr-in-charge.
All as per item No 10 here-in-before but wiring with 4.0 sqmm single core multi stranded copper conductor 1100 v grade PVC insulated unsheathed FRLS cable 1100 volts grade for geyser on independent board complete all as specified and directed by Engr-in-charge.
Supply and replace in repairs, switch piano type pole one way 6 Amps ISI marked AC 230V all as specified and directed. (Make : Anchor Penta or eqv)
Supply and replace in repairs, switch piano type pole two way 6 Amps ISI marked AC 230V all as specified and directed.
Supply and replace in repairs, switch piano type pole one way 16 Amps ISI marked AC 230V all as specified and directed.
Supply and replace in repairs, Bell push, flush type, 6 Amp ISI marked AC 230V all as specified and directed by Engr-in-Charge.
Supply and replace in repairs, socket outlet 2 in1,3 pin 5 Amps ISI marked , AC 230 V all as specified and directed.
Supply and replace in repairssocket outlet 2 in 1, 3 pin, 6 and 16 Amps flush type ISI marked AC 230V all as specified and directed.
Supply and replace in repairs, stepped fan regulator electronic type ISI marked AC 230V 120W all as specified and as directed.
Supply and replace in repairs, stepped fan switch type regulator electronic type ISI marked AC 230V 120W all as specified and as directed.
Supply and replace in repairs PVC ceiling rose 3-terminals ISI marked AC 230V all as specified and directed
Supply and replace in repairs PVC Angle holder ISI marked AC 230V all as specified and directed
Supply and replace in repairs PVC Batten Holder ISI marked AC 230V all as specified and directed
Supply and replace in repairs PVC Batten Holder plug ISI marked AC 230V all as specified and directed
Supply and replace in repairs Buzzer AC 230 volts all as specified and directed
Supply and replace in repairs Call bell ding dong AC 230 volts all as specified and directed
Supply and replace in repairs Call bell multimusic type AC 230 volts all as specified and directed
Supply and replace in repairs modular switch 1 way 6A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular switch 2 way 6A 1 module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular switch 1 way 10A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular switch 1 way 16A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular Bell push 1 way 6A 1 module, 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular socket 6A 2/3 pin combined 2 module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs modular socket 6A /16A 2/3 pin combined 2module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs module (step type) fan regulator,120 watt - 2 module 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs Modular switch socket combination multipurpose 3 pin, 15A and one pin, 5A controlled by one switch 230V AC ISI Marked complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 1module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 2 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 3 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 4 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 6 module complete all as specified and directed.
Supply and replace in repairs Modular white cover plate with frame 8 module complete all as specified and directed.
Supply and replace in repairs modular metal flush Box 1/2 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and replace in repairs modular metal flush Box 3 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and replace in repairs modular metal flush Box 4 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and replace in repairs modular metal flush Box 6 module complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and replace hylum sheet 3 mm thick for Junction boxes, circuit boxes and refixing the existing switches, sockets, regulators cut in to requied sizes including fixing with new cadmium plated screws and cup washers complete all as specified and as directed.
Taking down old unserviceable/burnt sub main wiring of 4 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC rigid metallic / non metallic on open surface conduit of suitable size including 4 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down old unserviceable/burnt sub main wiring of 6 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC rigid metallic / non metallic on open surface conduit of suitable size including 6 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down old unserviceable/burnt sub main wiring of 10 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 10 sqmm 1100 volt grade drawn into PVC rigid metallic / non metallic on open surface conduit of suitable size including 10 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down old unserviceable/burnt sub main wiring of 4 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn in existing PVC rigid metallic / non metallic on concealed/ surface conduit of suitable size including 4 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down old unserviceable/burnt sub main wiring of 6 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn in existing PVC rigid metallic / non metallic on concealed/ surface conduit of suitable size including 6 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down old unserviceable/burnt sub main wiring of 10 sq mm, M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 10 sqmm 1100 volt grade drawn in existing PVC rigid metallic / non metallic on concealed/ surface conduit of suitable size including 10 sqmm PVC multi standard copper conductor FRLS cable in green colour for earth wire including making good disturbed surfaces of wall/floor/ceiling to match with existing surface all as directed by Engr-in-Charge..
Taking down the unserviceable DB, Supply and replace distribution board factory made TPN 4- way vertical type with busbars & MCB TP as incoming, Double door metal type AC 415V suitable for fixing SP /TP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
Taking down the unserviceable DB, Supply and replace distribution board factory made TPN 6- way vertical type with busbars & MCB TP as incoming, Double door metal type AC 415V suitable for fixing SP /TP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
Taking down the unserviceable DB, fixing only distribution board factory made SPN 4- way vertical type with busbars & MCB SPN as incoming, Double door metal type AC 230V suitable for fixing SP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
Taking down the unserviceable DB, fixing only distribution board factory made SPN 8- way vertical type with busbars & MCB SPN as incoming, Double door metal type AC 230V suitable for fixing SP MCBs as out going all as specified & directed. Make; Legrand / L&T / ABB. Note; Cost of MCBs will be measured and paid seperately.
S & F Isolator TPN 63 Amps Make Anchor/ Legrand/ Seimense /ABB
S & F Isolator TPN 100 Amps Make Anchor/ Legrand/ Seimense /ABB
S & F MCB SPN 10 to 32 Amps .Make Havells/ Anchor/ Legrand/ Seimense /ABB
S & F MCB SP 5 to32 amps, .Make Havells / Anchor/ Legrand/ Seimense /ABB
S & F MCB SP 2 amps, .Make Havells / Anchor/ Legrand/ Seimense /ABB
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store
Hanging only ceiling fan (M.D. supply) and connecting up including providing of cable from ceiling rose or connector to fan
M & L for rewinding of ceiling fans of 1200 mm sweep of any make with supper enamelled copper winding wire appropriate gauge and after cutting the old burnt winding and cleaning the slots including varnishing and replacement of flexible cable 23/0.0076 mm to the required length, replacement of unserviceable bearing, PVC capacitor/terminal mounting as required including taking down and refixing, making connection and testing complete all as specified and directed by Engr-in-Charge. Note for item Nos 70 to 76: (a) The contractor will collect the U/S ceiling fans, Exhaust fans, geysers fro & Electric meters from JE through gate pass for repair in civil workshop. (b) In case, any item mentioned in note of item No 70 (a) is not returned to the dept the cost of the respective item will be recovered in RAR/FB from the contractor. No claim in this regard will be entertained. Decision of Engr-in-charge wiil be final. (b) Bearings will measured and paid separately under relevant item of sch.
All as per item No 70 above but ceiling Fan of sweep 1400 mm sweep all as speciifed and as directed.
All as per item No 70 above but Exhaust Fan with metal frame and of sweep 225-300 mm all as speciifed and as directed.
All as per item No 70 above but Exhaust Fan with metal frame and of sweep 450 mm all as speciifed and as directed.
All as per item No 70 above but Exhaust Fan PVC frame of sweep 225-300 mm all as speciifed and as directed.
Supply & replace broken wings of Exhaust Fan PVC of sweep 225-300 mm all as speciifed and as directed.
Supply & replace broken wings of Exhaust Fan PVC of sweep 225-300 mm all as speciifed and as directed.
Supply & replace capacitor for PVC Exhaust Fan( Square Type) 0.5 mfd all as specified and as directed by Engr-in-chargeMake:Havells/Epcos)
Supply and replace ball bearings of suitable size for 1200/1400 mm sweep ceiling fan complete all as specified and directed . Make : SKF/NBC or equivalent
Supply and replace ball bearing of suitable size for 225-300 mm sweep exhaust fan complete all as specified and directed . Make : SKF/NBC or equivalent
Supply and replace ball bearing of suitable size for 450 mm sweep exhaust fan complete all as specified and directed . Make : SKF/NBC or equivalent
S&F in split pin for ceiling fan 1200/1400 mm sweep as directed.
S&F in rubber yoke with clamps for ceiling fan 1200/1400 mm sweep as directed.
M & L only capacitor 2.5 mfd for ceiling fan all as specified and as directed by Engr-in-chargeMake:Havells/Epcos)
M & L only capacitor 4 mfd for ceiling fan all as specified and as directed by Engr-in-chargeMake:Havells/Epcos)
M & L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. all as specified and as directed.
M & L for repairs to storage type elect. water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following tasks at different locations as directed. (a) Inspection, taking down, opening ( dismantling ) descaling, brushing, cleaning of storage tank and painting internally with one coat of proprietary bituminous composition not liable to impart test or otherwise contaminate the water. (b) Replacement / repair of neon lamp / indicator lamp. (c) Replacement of the rubber / PVC gasket to ensure water tightness. (d) Testing of geysers after repairs.
Supply and replace in repairs thermostats ISI marked as per sample at site for geyser of capacity 25/35/50 Ltr of any make all as directed.
Supply and replace in repairs of safety valve/high pressure valve ISI marked as per site requirement or all as per directed.
Supply and replace in repairs heating element of rating 1.5/2 KW as required at site including rubber washers all as specified and directed by Engr-in-charge..
Supply and replace in repairs of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 cm long for cold water connection all as specified and directed by Engineer-in-charge.
Supply and replace in repairs metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge.
Supply and replace in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
Supply and replace in repairs, 25 ltrs copper container for geyser all as specified and directed by Engineer-in-charge.
M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 x 100 mm and 50 mm deep make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
M & L replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 200 x 150 mm and 50 mm deep make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
M & L replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250 x 200 mm and 50 mm deep make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
Decarbonizing of indoor MCB / meter box any type removing unserviceable MCBs, burnt connecting wires,replacing burnt, damaged wires of any size, welding of hinges including welding using extra sheets replace burnt thimbles of existing size , dismantling the existing connected cables/wires and re-connecting the same cables/wires complete all as specified and directed by Engr -in- charge. Note : (i) MCB will be measured & paid separately as supply only . (ii) necessary MS sheet and welding incuding sealing the meter with sealing Lead/PVC seal with MES Emblum empossing on it all are inclusive coated rate. (iii) Required size of copper cable for connecting MCBs and meters are including quoted rate.
M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate.
Labour only for attending Arman complaints received through Mobile App/complaint slip by deploying necessary skilled tradesman with helper as required at site on working hours from 0830 Hrs to 1730 hrs on all working days at OTM Area, Aundh Mil station. Note: - (i) The complaints will be entered in complaint slip by JE E/M MCM. (ii) The complaint slip should be returned to JE E/M on completion of the work with stores consumed. (iii) Any delay in attending the complaints for more than 03 days, a penalty of Rs 50/- per complaint will be adhered to the contractor. (iv) The details of stores consumed, complaint slip are to be produced during the RAR bills. (v) T & P, Minor spares like nuts, bolts, screws, washers insulation tape etc required for attending the complaints shall be provided by the contractor and the rate for the same is deemed to be included in the rate quoted..
Taking down old unserviceable conventional fitting and S & F wall mounted high quality indoor batten LED tube light with PVC housing,T-8 LED tube rod 20 Watt with T-8 LED Batten type with integral electronic driver 20 W, colour temperature 6500 K (4') , operating lifte 50000 hrs, lumen 1800-3000, diffused connecting with three core flexible copper wire from connector to ceiling rose / Angle Holder as per existing site requriement as directed by engineer in charge. Make: Havells / Bajaj / Philips / Crompton Greaves
Taking down old unserviceable conventional light fitting and S & F wall/ceiling mounted high quality indoor T-8 LED tube light 10 watt with PVC housing and T-8 batten with intergrated electronic driver 10 watt, colour temperature 6500 K, operating life 30000 hrs, 900-1350 lumen (2'), diffused connecting with three core flexible coopper wire from connector to ceiling rose/ Angle Holder as per existing site requriement as directed by engineer in charge. Make: Havells / Bajaj / Philips / Crompton Greaves
S & F in repairs 30 W Street /buidling security light fitting cast aluminium housing, toughened glass, IP 65/66, and pre wired with all accessories complete including entry for mounting on pipe bracket including extendable/supported 40 mm GI medium grade pipe of suitable size bracket bend to shape fixed as on wall / pole with suitable size of MS flat iron clamps 02 nos including grouting on wall / fixed on pole with nut, bolts and washers and painting with single coat of aluminium paint over one coat of primer on MS items complete all as specified & directed. Make; Havells / Bajaj /Crompton Greaves/Philips.
Supply and fixing including taking down MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, upto 100 amps, incl dismentling taking down unsv one, make- L & T Schneider/ABB /Legrand/Merlin Gerin.
Supply and fixing including taking down MCCB, 4 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, upto 160 amps, incl dismentling taking down unsv one, make- L & T Schneider/ABB /Legrand/Merlin Gerin.
M & L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire all as directed by Engr-in-Charge
Taking down carefully existing unserviceable Aluminium strip complete with saddles and screws . all as specified and directed by Engr In Charge.
Taking down care fully unserviceable Air terminations Aluminium rod 12 mm dia and 300 mm long all as specified and as directed by Engr In Charge.
Taking down unserviceablet test point terminal block all as specified and as directed by Engr In Charge.
Taking down unserviceable corroded rusted GI Pipe of any size with all fitting all as specified and as directed by Engr In Charge.
Supply & fix Aluminium strip 25 mm x 3 mm complete with porcelain insulated saddles and fixing screws for fitting the strip.
Fixing in repair aluminium strip 25 mm x 3mm complete with saddles and screws for fitting the strip.
M&L for Air terminations single pointed Aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangements on roof all as directed.
Supply and fix test point terminal block made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. head screw.
Repair /Maint of earthing pits by cleaning inside the pit ,removing the wastage material ,removing the vegetable groth surrounding the pit including replace the nut ,both ,washers and GI strip up to replaced lenght, Funnel etc and reflect near by the earthing number and test result complete all as specified and directed by Engr-in-Charge.
Material and labour for cement concrete in foundations/ trench filling and mass concrete type C2 1:3:6 (40mm graded aggregate) complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of size 40 mm bore for strip protection.
M & L for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x150mm duly fixed in MS angle iron 25mm x 25mm of 450 mm long to befixed to groundby means of cement concrete including painting with two coats fo synthetic enamel paint over a coat of reoxide primer complete including excavation and earth work. :- Fundation concreteexcavation and writing letters will be measured and paid separately.
Supply and lay 15 mm bore tubes medium grade galvanised with all fittings such as tees, bends, unions, elbows, reducers, clamps etc.
All as per item No 118 but 20 mm bore
Taking down UNSV GI tubing of 15 mm bore
All as per item No 120 but 20 mm bore
Taking down UNSV gun metal gate valve of size 15mmto 20mm all as directed by Eng in charge
Supply and fix 15 mm bore gun metal gate valve, cast copper alloy, screwed down, high pressure with iron wheel handle, screwed both ends for iron pipe or unions of the following sizes:-
All as per item No 123 but 20 mm bore
M&L for replacing bib taps cast copper alloy with crutch or butterfly handle screwed down for iron pipe or brass ferule of size 15mm including taking down.all as specified and directed
PURVA ELECTRICALS AND ENGINEERS
M/s. ANAND ENTERPRISES
Adinath Technical Services
M/S. Niksun Electro-Infra Private Limited
SKS Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .