Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.0 LAdmitted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | -11.37% | ₹14.0 L | L1 | Admitted-Finance |
| 2 | L2₹14.2 LAdmitted-Finance C 9 9 KRISHAN NAGAR DELHI 110051 | SHAHDARA | DELHI | 110051 | -10.10% | ₹14.2 L | L2 | Admitted-Finance |
| 3 | L3₹17.6 LAdmitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | SHAHDARA | DELHI | 110032 | +11.60% | ₹17.6 L | L3 | Admitted-Finance |
Tender Value
₹15.9 L
EMD Value
₹31,782
Closing Date
4 Apr 2026, 11:00 amClosed
Executive Engineer (Elect.)
EE(E),PWD NES/M-251, LM Bund Road, Ramesh Park, Delhi
(1) Providing and Fixing LED TV in Wards of HLTB/OAH, Tahirpur, Delhi - 110095. (2) SITC of Air Conditioner and Deep Freezer at OAH/HLTB, Tahirpur, Delhi - 110095.
2026_PWD_289379_1
122/EE(E)/PWD NES ED/2025-26
Open Tender
Electrical Works
30 days
Under Sub-2/M-2512
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹31,782
Yes
7 Apr 2026
28 Mar 2026
4 Apr 2026
28 Mar 2026
4 Apr 2026
28 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. | - | - | - | - | |
2 X 4 sq. mm + 1 X 4 sq. mm earth wire | - | Mtr | - | - | |
2 X 6 sq. mm + 1 X 6 sq. mm earth wire | - | Mtr | - | - | |
4 X 6 sq. mm + 2 X 6 sq. mm earth wire | - | Mtr | - | - | |
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required | - | Each | - | - | |
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole | - | Each | - | - | |
Supply, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).Inverter Type - Cooling only | - | - | - | - | |
1.5 TR with 5 Star BEE Rating | - | Each | - | - | |
Supply, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R- 32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filtration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electro technical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required | - | - | - | - | |
3.0 TR with 5 Star BEE Rating | - | Each | 0.29 | - |
stage.html
html • 0.03 MB
technical_384306.pdf
techsummary_384306.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.76 MB
BOQ_384306.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid