Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹28.3 L+₹4.8 L (20.6%)Rejected-AOC | L2 | Rejected-AOC higher rate | |
| 3 | L3₹30.9 L+₹7.4 L (31.8%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC higher rate | |
| 4 | L4₹35.2 L+₹11.8 L (50.3%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Rejected-AOC higher rate | |
| 5 | L5₹36.1 L+₹12.7 L (54.2%)Rejected-AOC A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L5 | Rejected-AOC higher rate |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
25 Jun 2022, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI, NEAR GATE NO 5, ABHM, SP MARG, NEW DELHI-21
REPAIR MAINT OF DG SETS SECURITY LIGHTS LT XLPE CABLES LT PANEL AND CONNECTED WORKS AT KASHMIR HOUSE UNDER GE NEW DELHI
2022_MES_527044_1
GE/ND-21/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
REPAIR/MAINT OF DG SETS,SECURITY LIGHTS,LT XLPE CABLES,LT PANEL AND CONNECTED WORKS AT KASHMIR HOUSE UNDER GE NEW DELHI
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹92,000
Yes
22 Aug 2022
28 May 2022
27 Jun 2022
28 May 2022
25 Jun 2022
11 Jun 2022
Amount
Supply and laying XLPE LT cable 1100 volts grade heavy duty with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC Tape armoured with galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS-7098 (Part-I) with latest amendments laid in tranches/fixed to wall/pole/laid in floor including taking out old unserviceable existing cable s any sizes and necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-Charge of following sizes :-
(a) 16 Sqmm 4 core.
(b) 25 sqmm 4 core
(c) 35 sqmm 3.5 core
(d) 50 sqmm 3.5 core
(e) 70 sqmm 3.5 core
(f) 120 sqmm 3.5 core
(g) 150 sqmm 3.5 core
(h) 185 sqmm 3.5 core
(j) 240 sqmm 3.5 core
Comprehensive maintenance of automatic power correction system of the rating 125/100/70 KVAr including replacement of capacitor if required ,replacement of fuse,cleaning of capacitor terminal,Check that the capacitor current is not lower than 25 % nor greater than 120 % of the nominal value by phase and there is no phase unbalance greater than 15 % ,check the continuity and temperature of the two pole circuit breaker. Note : Spare parts like capacitor and fuse included in the quoted rate.
Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular of size 10 sqmm
Demolition of cement concrete (un-reinforced) in ground floor and paving thickness not exc. 15 cm (below or above ground level) for removal of LT underground cable/GI pipe of any size description and making good (Type C2 PCC 1:3:6 40 mm aggregate) the same as per existing specifications after relaying new cable complete all as specified and as directed by the Engineer -in-Charge Note : GI pipe shall be measured and paid separately.
Supply only in replacement of MCCB, TP/TPN pole, 415 volt of capacity 125 amp, with breaking capacity 25 KA all as specified
Supply only in replacement of MCCB, TP/TPN pole, 415 volt of capacity 160 amp, with breaking capacity 25 KA all as specified
Supply only in replacement of MCCB TP/TPN pole 415 volt of capacity 200 Amps breaking capacity not less than 25 KA
Supply only in replacement of MCCB TP/TPN pole 415 volt of capacity 400 Amps breaking capacity not less than 35/36 KA
Supply & Fix in replacement MCCB TP/TPN 415 volts 63 amps with 16KA breaking capacity.complete all as directed.
Supply only in replacement saddle for Electrical cable mounting metal,strong corrosion condition resistance,easy installations of sizes 6cmX4.5cmX2.5cm
Supply only in replacement Electrical cable lugs aluminium,strong corrosion condition resistance,easy installations of sizes 16 Sqmm to 50 sqmm all as directed.
S & F Cable jointing kit for 1100 volt complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 35 sqmm all as directed.
S & F Cable jointing kit for 1100 volt complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm all as directed.
S & F Cable jointing kit for 1100 volt complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 120 t0 185 sqmm all as directed.
Supply and fix indicator lamp in different colour code LED/Neon type(as per sample) complete (RYB) including repair to wiring with copper conductor cable of existing suitable size all as specified
Supply, installing, testing and commissioning factory made and tested Outdoor type, platform mounted, Phase Sequence Corrector of capacity 63 A , 3 Phase 4 Wire, 415 volts, 50 Hz, platform mounted. The Phase Sequence Corrector shall be dust and vermin proof, protection class (IP-54) and made of 2.00 mm thick Stainless Steel Sheet 316L thick & suitable frame work/ support made out of 75 mm Stainless Steel flat channel, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. Make:- Havells/ Schneider / ABB/ L&T/ Universal Switch Gear Control. Note- Work includes civil work like excavation and preparation of PCC Plinth The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-54 2. CPRI Certification Short Circuit withstand strength should be 50kArms for 1.0 Sec with initial peak of 105kA 3. CPRI Certification Rated current for short circuit not less than 4000A with rated insulation voltage 660V 4. ISO 9001 CERTIFIED
Supply & fix in replacement of factory made vertical type load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified. Note: work includes cutting of wall as per DB size and requirement and making good to disturbed surfaces as existing surface.
Supply & fix in replacement of factory made vertical type load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 12 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified. Note: work includes cutting of wall as per DB size and requirement and making good to disturbed surfaces as existing surface.
Supply & fix in replacement of MCCB TP 100 Amp, 25 kA micro processor energy released type with OLED display complete all as specified.
Supply & fix in replacement of MCCB TP 125 Amp, 25 kA micro processor energy released type with OLED display complete all as specified.
Supply and fix in replacement only MCB SPN 40 to 63 Amp 220 volt with 10KA breaking capacity.complete all as directed.
Supply and fix in replacement MCB SP 5to 32 Amp 220 volt with 10KA breaking capacity.complete all as directed.
M& L for shifting of LT panel board/LT feeder pillar box from low line side to as required level minimum 1.2 Mtr hight including taking down existing LT cable of any size,refixing as same condition incoming and out going cables and grouting of LT panel, provn of PCC foundation all as directed by Engr-in-Charge.
Supply and fix in replacement install in replacement ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 125 Amps.
Supply and fix in replacement install in replacement ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps.
Preventive maintenance of DG sets(125X01 ,160X1 ) installed at different location of Kashmir House .The following daily maint to be carried out as under (i) Check levels in oil through ,fuel tank cooler and replenish if necessary (ii) Re-grease all grease points (iii) Tighten the nuts bolts of pipeline of fuel oil ,lubricating oil,water and check leakages (iv) Check the water level in radiator and top up the coolant as required (v) Clean oil filters (vi) Check viscosity of lube oil (vii) Check crank case for leakage (viii) Clean air filters (ix) Check the radiator fan belt (x) Timely replace the engine oil/oil filter/diesel filter/air filter (xi) Check distilled water for battery and top up (xii) Check battery cover condition from cover and battery voltage (xiii) Check the insulation resistance of alternator
M&L for"B" Check with kit DG set of following capacity at different location by taking out U/S spares,l, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, check the serviceability of AVR ,frequency etc greasing oiling and checking For smooth functioning of DG Set Note :- Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid separately under respective items .
(a)125 KVA DG SET
(b) 160 KVA DG SET
Supply and replacement of battery 12V 90AH maintenance free battery, 12 Volt intially charged with suitable size of copper leads and brass terminals complete as directed by Engr-in-charge.
Servicing of Generator AMF Panel of following Gen set at different location complete including labour for replacement of u/s spares, testing complete all as specified and directed (Note:unserviceable spares required to be replaced shall be measured paid for separately under respective items .)
(a)125 KVA DG SET
(b) 160 KVA DG SET
Supply in replacement Fan belt B-56, for DG set
Supply in replacement Air cleaner for DG set
Supply in replacement Diesel Filter for DG set
Supply in replacement Oil filter for DG set
Supply in replacement High pressure wire braided diesel pipe with benjo bolt 1 mtr long for DG Set
Supply in replacement Kirloskar Engine Oil 20W 40 Make: Castrol/HP
Supply in replacement battery 12V
Supply in replacement Battery terminal gun metal as per sample
Supply in replacement Coolant ready mix make Castrol /Equivalent
Supply in replacement Battery Charger 12 Volt DC,for AMF Panel
Supply in replacement Battery water with electrolyte.
Supply in replacement AMF panel timer relay for circuits 230Volt AC supply as per existing make and capacity.
Supply in replacement fuse 250Amps for AMF Panel
Supply in replacement 3 pole power contactor 160 A ,MNX 140 for AMF Panel Make: L&T /Siemens
Supply in replacement 3 pole power contactor 100 A, MNX 80 for AMF Panel Make: L&T /Siemens
Supply in replacement MCCB 3 pole 200 A 25 KA for AMF Panel
Supply in replacement MCCB 3 pole 125 A 16 KA for AMF Panel
Supply in replacement MCCB 3 pole 100 A 16 KA for AMF Panel
Taking down the DG Set of cap upto 160 KVA from base frame dismantling the engine transporting to repairer workshop for overhauling and replacement of unserviceable spare part lathe work required for the repair ,assembling after repair and transporting back to site ,installation ,connection and load testing complete all as specified and directed Note: Spares required for replacement shall be measured and paid separately under respective item.
Supply in replacement Cylinder liner with joint ring
Supply in replacement Piston assembly complete
Supply in replacement Gasket for cylinder head (1.22mm)
Supply in replacement Set of joints (for PG )/4H.3031
Supply in replacement Inlet and exhaust valve pair
Supply in replacement Valve guide (for inlet & exhaust)
Supply in replacement Valve seat insert (inlet)
Supply in replacement Valve seat insert (exhaust)
Supply in replacement Valve seal
Supply in replacement LE bearing STD
Supply in replacement Lube oil 20 Ltrs Pack
Supply in replacement Cylinder head repair
Supply in replacement Turbo Repair kit
Supply in replacement Injector Repair
Supply in replacement Fuel Pump repair
S&F in repair of Self Starter 24 volts suitable for upto 160 KVA DG Sets complete all as specified and directed.
S&F in replacement flood light/street lights/recess mounted LED lights drivers 36/70/90/120 watts, 230 volts AC out door type with rectangular with innovative thermal management in multiple optics and equipped with IP 66 protection all as specified.
M&L in replacement LED inverter based 90 watt building security(street light) fitting complete with accessories made of aluminium housing having minimum system efficiency 100 lm/watt operating at full load at AC supply & minimum 20 watt during battery back up , power factor is equal to or greater 95, CCT 6500K, CRI -80, IP-20, inbuilt Li-ion battery for backup, back up to 4 Hrs for complete tube light (partial back up not allowed), LM-79 & 80 complete including taking down old U/S light fittings all as specified and directed. Make-Halonix HLSLD-ML04-45CWL-INV or equivalent in Havells. Note: Two year warranty shall be provided by the manufacturer from the date of supply.
S&F in replacement street light luminaires, LED type 90 watts, 230 volts AC out door type with high pressure die cast aluminium housing and heat resistant flat complete with driver, lamp bracket GI pipe light grade 1.5 meter long made out of 40 mm bore bend to shape, flat iron clamps made out of 50x6mm flat iron with nut bolts and washers including taking down old u/s lighting fittings and painting clamps and electric connection with three core 1.5 sqmm copper cable complete as directed.all as specified.
S&F in replacement flood light luminaires, LED type100 watts, 230 volts AC out door type with rectangular with innovative thermal management in multiple optics and equipped with IP 66 protection resistance to impact and corrosion glare free complete with driver, lamp including taking down old U/S lightning fittings all as directed and specified.
Supply and fixing in replacement post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp including taking down old U/S lightning fittings all as directed and specified.
M&L for Removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth all as per specified and directed by Engg-in-charge.
M&L for spots with thinner applying two coats of spray painting priming with aluminium oxide on outside with spraying machine to LT Panels indoor/outdoor after disconnecting of power supply from incoming and LT supply from outgoing complete all as specified and directed .
Supply and fixing of Monkey menace protection device with pvc spikes size as per sample all as specified and directed
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for laying of LT under ground cable/ GI pipe complete all as specified
Returning filling including spreading, levelling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removing excavated materials to a distance not exec. 50 mtr and deposing where directed at a level not exec 1.5 mtr above the starting point and making good surface of disturbed st site all as specified.
M&L for Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed
Supply and fix CABLOFIL wire meshed Hot dip Galvanized cable tray 54mm (h) x 100 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable any size ,if require through wall cutting and making to good surface in disturbed area all as directed by Engr-in- Charge
Supply and fix CABLOFIL wire meshed Hot dip Galvanized cable tray 54mm (h) x 200 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable any size,if require through wall cutting and making to good surface in disturbed area all as directed by Engr-in- Charge.
Supply and fix CABLOFIL wire meshed Hot dip Galvanized cable tray 54mm (h) x 300 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends.for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable,LAN /signal cable ,if require through wall cutting and making to good surface in disturbed area all as directed by Engr-in- Charge.
S.R. Constructions
RUCHIKA ENGG.WORKS
SANJEEV ENTERPRISES
M/s Adhikari construction co.
Surjit and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .