Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.1 LAccepted-AOC SANAT NAGAR SRINAGAR PIN 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹28.0 L+₹1.6 L (5.90%)Rejected-Finance RAWALPORA WANABAL PATI YAYIL POST OFFICE SANAT NAGAR SRINAGAR 190005 J K | SRINAGAR | JAMMU AND KASHMIR | 190005 | L-2 | Rejected-Finance other than L-1 | |
| 3 | L-3₹30.9 L+₹4.5 L (17.2%)Rejected-Finance | L-3 | Rejected-Finance other than L-1 |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
26 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt. Col Preetham P GE
GE 970 EWS C/o 56 APO PIN-913970
CERTAIN SANCTIONED OF EM WORK AT VARIOUS LOCATIONS UNDER GE 970 EWS
2024_MES_643906_1
GE 970 EWS-73/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
UNDER GE 970 EWS
AS PER TENDER
7 documents required · 7 mandatory
₹500
Yes
GE 970 EWS
₹65,000
Yes
24 May 2024
23 Feb 2024
1 Apr 2024
23 Feb 2024
26 Mar 2024
8 Mar 2024
Amount
Supply, installation, testing and commissioning of 500 Litres Kerosene/Diesel based hot water plant with fuel tank and 200 litres water heater Boiler with all accessories having capacity of 35000 Kcal/hr, oil fired with thermostate, one inch thick glass wool insulated, automatic air release valve, oil burner, MS Oil storage tank of 200 ltrs capacity with powder coated outer body complete all as specified and directed. Make: Thermax/Maktek/Rapidtherm/ Ecoflame /Zenith/ Western/Reillo
Supply and installation of MS flue gas exhaust pipe made out of 3 mm thick MS sheet, minimum 1.2 m above the highest point of the plant room and including connection from Hot Water generator to main vertical exhaust pipe fabricated from 3 mm MS sheet. The item shall be complete with the mounting/ fixing arrangement. The Hot Water generators shall be connected to an independent flue gas exhaust pipe of suitable size and as per manufacturers guide lines. The portion of the flue gas exhaust pipe inside the building shall be insulated with fiber glass insulation wool of 24kg/cum with aluminum cladding. The item shall be complete with mounting/fixing arrangement
M&L for 3-layer PP-R Polypropylene random copolymer pipes of 40mm dia, SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed.
M&L for 3-layer PP-R Polypropylene random copolymer pipes of 25mm dia, SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed.
M&L for 3-layer PP-R Polypropylene random copolymer pipes of 20mm dia, SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and directed.
M&L for Lagging on pipes used in water supply or plumbing all around with 25 mm thick bonded mineral wool performed SNAP ON pipe section of density 144 Kg/cm confirming to IS: 9842 provide with and including chicken mesh wire netting 25 gauge, 20mm mesh and 0.01mm aluminium foil for 40mm dia of pipe complete all as specified and directed.
M&L for Lagging on pipes used in water supply or plumbing all around with 25 mm thick bonded mineral wool performed SNAP ON pipe section of density 144 Kg/cum confirming to IS: 9842 provide with and including chicken mesh wire netting 25 gauge, 20mm mesh and 0.01mm aluminium foil for 25mm dia of pipe complete all as specified and directed.
M&L for Lagging on pipes used in water supply or plumbing all around with 25 mm thick bonded mineral wool performed SNAP ON pipe section of density 144 Kg/cum confirming to IS: 9842 provide with and including chicken mesh wire netting 25 gauge, 20mm mesh and 0.01mm aluminium foil for 20mm dia of pipe complete all as specified and directed.
M&L for 40 mm dia Gun-metal gate valve with iron head wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for 25 mm dia Gun-metal gate valve with iron head wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for Bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle screwed both ends for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm dia complete all as specified and directed.
M&L for cutting the existing GI Tubing of size 50mm dia for making new connection of 25/40 mm dia GI pipe complete with all fittings complete all as specified and directed
M&L for 50mm thick PUF insulated Rotational moulded polyethylene water storage tanks three layer of capacity 500 litre, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm ball valve high pressure of PTMT with epoxy coated Aluminum rod & high-density plastic ball etc complete all as specified & directed. Make- Sintex/Supreme/Plasto
Blank
Supply and laying under ground LT cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 16 Sqmm, 2 core, with aluminium conductor with suitable size aluminium cable lugs and jointed in any description complete all as specified and directed. NOTE:- 1. Excavation , earthwork, bicks, pipemand sand for cushioning will be measured and paid separately. 2. Cost of aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape), gable gland, new nut bolt and washers of required size shall deemed to be included in the unit rate quoted by the tenderer.
All as per item no 15 but for cable size of 50 Sqmm 3.5 Core
All as per item no 15 but for cable size of 35 Sqmm 3.5 Core
Material and Labour for cable end jointing kit for 1.1 KV grade cable for Indoor/oudoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3½ core XLPE armoured Aluminium conductor size of 25 to 50 sqmm complete all as specified and directed by Engr-in-Charge.
Excavation over areas n exc 1.5 cm deep and and getting out in any type of soil complete all as specified and diredted.
Excavation in trenches in any type soil not exceeding 1.5 Mtr in wide and not exc. 1.5m in depth for taking out / laying of under ground cable in trenches or cable ducts all complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil after repairing / jointing and laying and testing of cables complete all as specified
Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point complete all as specified
M&L for natural river sand as cushioning of cables including spreading and punning down all as per clause No 19.75 of SSR part -I all as specified. Note : punned thickness shall be measured for payment purpose
Supply and lay brick of conventional size 230x115x75mm locallly available as protection of cable in trenches complete all as specifed and as directed.
Supply and lay cable cover of size 250x150x40mm, class LV, type I, flat, as in protection of cable in trenches complete all as specifed and as directed.
S&F automatic voltage stablizer for low and high voltage connected equipped with electronic transistors relay suitable for connection of single phase, 50 Hz AC supply complete with voltmeter and designed for input voltage 170-220 Volts of capacity and output voltage stablized 230 Volts (+/-) 2.5% ) of capacity 01 KVA complete all as specifed and as directed. Make: Powerware/ Sinetrac/ Microtek/ V-Guard
Supply, installation, testing & commissioning of monoblock centrifugal pump driven by suitable capacity electric motor for hot water supply of 12/32Mtr head Range Discharge 3600/700 LPH complete with accessories including, pressure gauge, NRV,pressure cutout switch, pressure tank, cement concrete foundation and all as specified and directed. (Note:- Pump should be fitted with mechanical seal and operative under temperature between 60°C to 75°C) Make: Kirloskar/ Crompton/ Becon/ KSB/ Jyoti
BLANK
Material and labour for sub main wiring with two runs of single core PVC insulated (FRLS) unsheathed copper conductor multistranded cable of size 4 sqmm 1100 volts grade drawn through in & including PVC conduit 25mm dia & 4 sqmm single core copper conductor multistranded PVC insulated (FRLS) unsheathed cableas earth wire continuity conductor complete all as specified and directed by Engineer in charge. Note : (i) Two run of cable 4 sqmm and one run of 4 sqmm earth wire shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
M&L for hard core of guage exc 63mm broken stone or boulders, deposited spread and levelled in layers n exc 15cm thick, watered, rolled and rammed to a true surface complete all as specified and diredted.
M & L for 100 mm thick PCC 1:3:6 Type C 2 ( 40 mm graded aggregate ) as in Floor sub base complete all as specified and directed.
M & L for 40 mm thick PCC Type 1:2:4 B 1 ( 20 mm graded aggregate) as in floor finish to receive top finish of floor complete all as specified and directed.
M & L for PCC Type 1:2:4 B 0 ( 12.5 mm graded aggregate) as in coping or mud stops, rounded or chamferred on edges complete all as specified and directed.
Excavating in post holes each n exc 0.5cum, getting out, returning, filling in and ramming earthor broken rubble mixed with earth around, in layers not exceeding 25cm, complete all as specified.
Steel work in tubular trusses incl special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240
S & F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
M&L pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ caldding to wall fixed with self tapping screws as specified
M&L for preparing newly steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide all as specified.
Supply installation, commissioning and testing of LT panel, outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated out of 3mm thick mild steel sheet mounted, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-1, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN Aluminium bus bars suitable for 400 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs and cable glands complete all as specified and directed by Engr-in-Charge( LT Panel Make: CPRI approved) and also comprissing of following:- Incoming:- (i) MCCB 320 A 04 pole - 35 K 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider
Outgoing:- (i MCCB 100 A 04 pole - 25 K 02 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (ii) MCC 63 A 04 pole - 25 K 02 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (iii) Copper bus bar suitable of capacity 480 A - set of 4 (iv) Digital Voltmeter. Make: HPL/SEIMENS/L&T- 01 No (v) Digital Ammeter. Make: HPL/SEIMENS/L&T -01 No (vi) R-Y-B Neon indicator lamp panel mounting type (set of 03) = 01 Set (vii) CT as per suitable capacity (set of 03) (viii) Control wiring of suitable 4/6 sqmm copper wire for connecting above accessories-each job (ix) PCC Work for Panel foundation -each job
M&L LT indoor/outdoor end joint (Heat Shrinkable) for under ground XLPE , PVC insulated and PVC sheathed armoured heavy duty cables with aluminium conductor including jointing kit, including making joints for the cable of size 25 to 50 sqmm x 3.5 core cables including testing and commissioining complete all as specified ( Make : Densons / 3M / Raychem)
Aluminum strip of size 25 x 3mm with saddles and fixing screws etc. complete all as specified and directed.
Copper strip of size 32 x 6mm complete all as specified and directed.
Material and labour earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected togalvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.3 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia light grade protection pipe and salt etc and connected to earthing test point incl necessary earth work, testing complete all as specified and as directed.
Supply and fixing of Air termination, single pointed Aluninium rod 12 mm dia and 300mm long complete all specified and as directed by Engr-In-Charge.
Supply and fixing of terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 nos 8 mm dia 25mm long hex head screwed air termination single pointed aluminium rod 12mm dia and 300mm long complete all specified and as directed by Engr-In-Charge.
S & F, testing and commissioning in replacement of outdoor type factory made power coated AMF Panel board cubical type, overall size as per IS standerds, suitable for DG set 32.5 KVA capacity, with suitable size of 4 Nos copper bus bar 400 Amps, having locking arrangements floor mounted free standing weather proof panel with IP-54 protection fabricated out of suitable sizes angle iron and falts and covered with 3.15mm thick CRCA sheet duly pretreated in seven tank process for de- greasing, de- rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be furnished and then painted with final coat of epoxy based powder coated paint. Panel shall be compartmentrised with rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & Outging cables. Panel have CT 5/400 Amps -03 Nos, Digital Ammeter 0-200 Amps, Digital Voltmeter 0-500 Volts, phase indicator LED (RYB) -03 Nos. A clear space of 400 mm to be kept for floor level for switchgear compartment. Extended bbusbar links/ terminals to be provided for connecting cables. Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:-
Srl item No 46.0 Contd... (a) Power contractor -04 pole of suitable current rating with thermal overload relay-02 Nos (for alternator and Mains) (b) HRC fuse of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating functions:- - Supply Failure timer. - Restoration timer. - 3 Impulse automatic engine start/ stop logic - Mains / Generator Voltage & Frequency sencing (d) Aluminium bus bars of suitable capacity with incoming / outgoing terminals (e) Instrument fuses duly wired and ferruled (f) MCCB of suitable rating 4 Pole with overload and short circuit protection -02 Nos (for alternator & mains) (g) Current Transformer of suitable rating Note: Factory inspection for above breaker will be carried out by the officer detailed by Accepting officer before despatch of above breakers. The cost of the same shall be deemed to be included in the rate quoted
S & F, testing and commissioning in replacement of outdoor type factory made power coated AMF Panel board cubical type, overall size not less than 900x 750x 450 mm suitable for DG set 15 KVA capacity, with suitable size 4 Nos copper bus bar 400 Amps, having locking arrangements floor mounted free standing weather proof panel with IP-54 protection fabricated out of suitable sizes angle iron and falts and covered with 3.15mm thick CRCA sheet duly pretreated in seven tank process for de- greasing, de- rusting & phosphated painted with 2 coats of primer paint then the panel surface shall be furnished and then painted with final coat of epoxy based powder coated paint. Panel shall be compartmentrised with rubber gasketed hinged door. Panel shall be having only one side opening for installation of separate cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming & Outging cables. Panel have CT 5/400 Amps -03 Nos, Digital Ammeter 0-200 Amps, Digital Voltmeter 0-500 Volts, phase indicator LED (RYB) -03 Nos. A clear space of 400 mm to be kept for floor level for switchgear compartment. Extended bbusbar links/ terminals to be provided for connecting cables.
Srl item No 47.0 Contd... Air ventillation louvers to be provided for heat dissipation with earthing terminal at each end of the panel. Suitable sized knock-out holes consisting of the following:- (a) Power contractor -04 pole of suitable current rating with thermal overload relay-02 Nos(for alternator and Mains) (b) HRC fuse of suitable current rating for short circuit protection (c) Microprocessor based AMF module incorporating functions:- - Supply Failure timer. - Restoration timer. - 3 Impulse automatic engine start/ stop logic - Mains / Generator Voltage & Frequency sencing (d) Aluminium bus bars of suitable capacity with incoming / outgoing terminals (e) Instrument fuses duly wired and ferruled (f) MCCB of suitable rating 4 Pole with overload and short circuit protection -02 Nos (for alternator & mains) (g) Current Transformer of suitable rating Note: Factory inspection for above breaker will be carried out by the officer detailed by Accepting officer before despatch of above breakers. The cost of the same shall be deemed to be included in the rate quoted
Demolition of un-reinforced cement concrete in ground floor and pavings n.exc 15cm thickness (below or above ground level).
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and pigment, 30mm thick sand cushioing for interlocking tiles including watering and consolidation all as specified complete all as specified.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M & L for brick work with sub class B bricks, straight or curved on plan exc 6m mean radius built in CM1:6, complete all as specified and directed.
M&L for DPC 40mm thick in cement concrete 1:2:4, type B0 to horizontal surfaces including necessary formwork complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (40mm graded aggregate) in foundation filling and mass concrete, complete all as specified and directed.
Rendering 15 mm thick cement plaster on fair surfaces of brick work or concrete surfaces in CM 1:4 finished to even and smooth without using extra cement, complete all as specified and directed.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
Preperaing new plastered surfaces of wall and applying two coats of cement base paint , complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coat of oil bound distemper over a coat of alkali resistant primer on surfaces of wall complete all as specified and directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. steel conforming to E-250 (Fe 410) quality 'A' complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not ortherwise provided for , complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth by applying with two coats of synthetic enamel paint over a coat of red oxide primer , complete all as specified and directed.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
All as per item no 62 above but W/O glazing bar.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0
S&F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.00 mm fixed with tinned tacks, or galvanised wire staples wire, complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) in , plinth protection , including finishing the surface even and fair without using extra cement, complete all as specified and directed.
M & L for 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in hardstanding of ramp, path etc including finishing rough surface without using extra cement and laid in alternate bays, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in sub base, complete all as specified and directed.
M&L for 25 mm thick plain cement concrete 1:2:4 type B-0 ( using 12.50 mm graded stone aggregate) as in sub bases of floors finished even and fair, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (Square/Rectangular) area exceeding 0.11 sqm but not exceeding 0.18 sqm in floors set and jointed in neat cement slurry, over and including 15mm thick screed bed in CM (1:6), jointed in neat cement slurry and pointed in coloured cement, complete all as specified and directed.
Taking down chowkats or frames with shutters (with out taking off shutters from the frames) exc 1.5 Sqm but not exceeding 4 Sqm each all as specified and directed.
Taking down chowkats or frames with shutters (with out taking off shutters from the frames) not exc 1.5 Sqm each all as specifed and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each
M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete , of frame size 105 x 60 mm, incl provision of back filling of chowkhat with PCC 1:3:6 type C1,complete all as specified
S&F flush shutters 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified
M&L for preparation of new wooden surface of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
S&F Butt hinges of size 100mm length, extruded aluminium alloy with galvanished mild steel hinges pin, anodized & fixed, type C-21, complete all as specified and directed.
S&F Alluminium, anodized, barrel tower bolts 150mm extruded section.
S&F 150mm long extruded aluminium alloy anodised handles fabricated type complete all as specified and as directed by the Engineer-in-Charge.
S&F aluminium alloy sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia and including a minimum of 6 bolts and nuts,four on bolt type and two on staple plate 250 mm long, complete all as specified and directed.
S&F floor door stopper 150mm length of cover plate of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor, complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets any thikness including cover fillets, complete all as specified and directed.
M&L for anodised aluminium snap grid frame work size of grid 605 x 605mm for false ceiling , incl GI suspension, complete all as specified and as directed.
M&L for 8mm thick decorative coloured non asbestos fibre cement building boards fixed or laid/inserted to Aluminium framework with screws in any position flat or slop and fixed in jointless finish with jointing compound and jointing tape as per manufacturer instructions complete all as specified and as directed.
FIRDOUS AHMAD BABA
RASHID CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .