| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 LAccepted-AOC | 1 | Accepted-AOC L1 bidder and work awarded by the SPC | |
| 2 | 2₹5.1 L+₹11,800 (2.37%)Rejected-AOC VPO SHODHAPUR PANIPAT 132103 | PANIPAT | PANIPAT | HARYANA | 132103 | 2 | Rejected-AOC L2 being higher rates |
Tender Value
₹3.7 L
EMD Value
₹8,800
Closing Date
5 Oct 2024, 3:00 pmClosed
BRIJENDER SARSOOT
CE PTPS Panipat
ARC of repair and maintenance of Pumps and Gear Boxes of DM, ET and PT plants of 250 MW, Unit-7and8, PTPS, Panipat
2024_HBC_398695_1
2024179F7607 9288 4B6A AA2D 399C82EEB9EC713PGC
Open Tender
Machineries/ Mechanical Engg Items
Works
821 days
ASSAN KHURD
As Per NIT
2 documents required · 2 mandatory
₹1,180
Yes
₹8,800
Yes
26 May 2025
9 Aug 2024
9 Oct 2024
9 Aug 2024
5 Oct 2024
9 Aug 2024
9 Aug 2024 - 4 Oct 2024
Amount
REPAIR AND MAINTENANCE OF SLUDGE DISPOSAL PUMP OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF DM TRANSFER PUMP OF DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF DM REGENERATION PUMP OF DM PLANT OF 250 MW, UNIT 7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF DEGASSER PUMP OF DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF ACID UNLOADING PUMP OF DM PLANT OF 250 MW, UNIT 7and8, PTPS PANIPAT
REPAIR AND MAINTENANCE OF ALKALI UNLOADING PUMP OF DM PLANT OF 250 MW, UNIT-7 and 8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF N-PIT PUMP OF DM PLANT OF 250 MW, UNIT-7 and 8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF FLUCULATOR GEAR BOX WITH ASSEMBLY AT MAIN CLARIFIER OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF MAIN DRIVE GEAR BOX WITH CHAIN WHEEL AT MAIN CLARIFIER OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF FLASH MIXER GEAR BOX WITH ASSEMBLY AT MAIN CLARIFIER OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF FLUCULATOR GEAR BOX WITH ASSEMBLY AT DMPT CLARIFIER OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF MAIN DRIVE GEAR BOX WITH CHAIN WHEEL AT DMPT CLARIFIER OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF FLASH MIXER GEAR BOX AT DMPT CLARIFIER OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF AGITATOR GEAR BOX AT CHEMICAL HOUSE OF PT PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF BLOW DOWN SUMP PUMP OF BOILER AREA OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF DRAIN SUMP PUMP OF BFP AREA OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF DRAIN SUMP PUMP CONDENSAR AREA OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF DRAIN SUMP PUMP TRANSFORMER YARD OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF COMMON LUB OIL SUMP PUMP OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF COMMON SLUDGE SCREW PUMP OF ET PLANT OF 250 MW, UNIT 7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF GUARD POND PUMP OF ET PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF DRAIN SUMP PUMP OF ET PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF OIL WATER SUMP PUMP OF DAY TANK AREA OF ET PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPA
REPAIR AND MAINTENANCE OF ALUM AGITATOR GEAR BOX OF ET PLANT OF 250 MW, UNIT 7and8, PTPS, PANIPAT
REPAIR AND MAINTENANCE OF LIME AGITATOR GEAR BOX OF ET PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPLACEMENT/LAYING OF MS/MSRL PIPES OF SIZE 50 TO 75 NB IN ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPLACEMENT/LAYING OF MS/MSRL PIPES OF SIZE 100 TO 125 NB IN ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPLACEMENT/LAYING OF MS/MSRL PIPES OF SIZE 150 NB IN ET, PT and DM PLANT OF 250 MW, UNIT 7and8, PTPS, PANIPAT
FABRICATION/ ERECTION OF BENDS/ TEES (90°/45 deg. OR AS PER SITE REQUIREMENT) OF SIZE 150 NB and ABOVE IN ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
FABRICATION/ ERECTION OF BENDS/ TEES (90°/45 deg. OR AS PER SITE REQUIREMENT) OF SIZE 50 TO 75 NB IN ET, PT and DM PLANT OF 250 MW, UNIT 7and8, PTPS, PANIPAT
FABRICATION/ ERECTION OF BENDS/ TEES (90°/45 deg. OR AS PER SITE REQUIREMENT) OF SIZE 100 TO 125 NB IN ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
WELDING WORKS OF M.S. PIPES/ VALVES/ BENDS/TEES FOR REPAIR WITH MEASUREMENT OF PER INCH DIA
RUNNING WELDING IN ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
WELDING PATCH UP TO 1 SQ. FEET
FABRICATION and ERECTION OF MS CLAMPS UP TO 100 MM DIA
FABRICATION and ERECTION OF MS CLAMPS FROM 101 TO 500 MM DIA
SERVICING OF SLUDGE VALVE OF SIZE-500 NB OF MAIN CLARIFIER BRIDGE
SERVICING OF GATE VALVE OF SIZE-100 NB OF SLUDGE PUMPS AT MAIN CLARIFIER PIT
SERVICING OF CHECK VALVE OF SIZE-100 NB OF SLUDGE PUMPS AT MAIN CLARIFIER PIT
SERVICING/REPAIRING/REPLACEMENT OF GATE VALVES, GLOBE VALVES, NRV, BUTTERFLY VALVES FROM 15 TO 50 MM OF ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
SERVICING/REPAIRING/REPLACEMENT OF GATE VALVES, GLOBE VALVES, NRV, BUTTERFLY VALVES FROM 50 TO 100 MM OF ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
SERVICING/REPAIRING/REPLACEMENT OF GATE VALVES, GLOBE VALVES, NRV, BUTTERFLY VALVES FROM 100 TO 150 MM OF ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
SERVICING/REPAIRING/REPLACEMENT OF GATE VALVES, GLOBE VALVES, NRV, BUTTERFLY VALVES FROM 150 TO 200 MM OF ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
SERVICING/REPAIRING/REPLACEMENT OF PNEUMATIC VALVES, DIAPHRAGM VALVES OF ET, PT and DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
REPAIR OF EXCHANGERS/ REPAIR OR REPLACEMENT OF BRINE DIFFUSER OF EXCHANGER OF DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
CLEANING OF STRAINERS OF ANION/CATION/MIX BED EXCHANGER OF DM PLANT OF 250 MW, UNIT-7and8, PTPS, PANIPAT
M/S RAJINDER CONSTRUCTION (BID ID -1148980)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .