Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹15.2 L+₹2.1 L (16.2%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹18.6 L+₹5.6 L (42.9%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹20.0 L+₹6.9 L (53.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
10 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY AT TECHNICAL AREA AT AF STN GORAKHPUR.
2021_MES_422601_1
8763/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE(AF) GORAKHPUR
As Per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹36,000
Yes
25 Mar 2021
16 Feb 2021
11 Mar 2021
16 Feb 2021
10 Mar 2021
24 Feb 2021
60 days
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for cable trench complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F in replacement 80mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Boring of holes horizontally for laying of 80 mm dia pipe (minimum depth 1200mm from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply, laying and testing in replacement 10 Sqmm, 2 core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
All as per item No. 8 above but for 25 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 50 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 70 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 95 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 120 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 150 Sqmm, 3.5 core XLPE cable.
All as per item No. 8 above but for 185 Sqmm, 3.5 core XLPE cable.
Taking out old existing LT UG cable of any size from trench and relaying of LT Cable after repair in trench including excavation, returning, refilling of sand and bricks complete all as specified and directed. Note:- Cable joint will be measured and paid separately under relevant item.
M&L for straight through LT cable joint kit including cutting of faulty cable, preparation and jointing complete of size 16 sqmm to 50 sqmm 3.5 core including taking out old joint complete all as specified and directed. Make: Dension/ MS-Seal/ Fontech/3-M
M&L for straight through LT cable joint kit including cutting of faulty cable, preparation and jointing complete of size 70 sqmm to 150 sqmm 3.5 core including taking out old joint complete all as specified and directed.
M&L for straight through LT cable joint kit including cutting of faulty cable, preparation and jointing complete of size 185 sqmm to 240 sqmm 3.5 core including taking out old joint complete all as specified and directed.
Restringing of old ACSR or AAAC conductor of any size and make on LT/HT 9/11 mtr long poles including earth wire, replacement of binding wire and aluminium taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including pruning and cutting of tree branches 3 mtr all around OH LT/HT line and cleaning of creepers around pole complete all as specified and directed. Note: 04/03 Nos of ACSR or AAAC conductor shall be measured as one unit length.
Repairing/ replacement of unserviceable MCCBs/ MCBs/ changeover switch in LT panel boards/ DBs any type including replacing of burnt out lugs, including cutting of burnt cable terminals, prepare and crimping the cable lugs with LT cables in no light/ unhealthy light complaints and making serviceable in all respect by providing skilled manpower. Work shall also include checking and removal of leakages in neutral and phase in 440/220 Volts connection as and when directed. NOTE:- (a) The rate quoted by the contractor for Each Job is deemed to inclusive of minimum 2 complaints. (b) The contractor or his representative will take complaints from MES and rectify the complaint. (c) The ladder and T&P as required will be provided by the contractor (d) Risk factor will be on the contractor's end (e) Minor items like cable lugs, Insulation tape, nut, bolts etc deemed to be included in rate quoted (g) MCCB/changeover will be measured and paid separately in the relevant items as under in supply only:-
Supply only in replacement MCCB, 100 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 16 KA complete all as specified and directed.
Supply only in replacement MCCB, 160 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
Supply only in replacement MCCB, 200 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
Supply only in replacement MCCB, 250 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
Supply only in replacement MCCB, 400 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 36 KA complete all as specified and directed.
Supply only in replacement MCCB, 630 Amp, 4 Pole, 50 HZ, 415 Volt, with thermal magnetic based release and rupturing capacity 50 KA complete all as specified and directed.
Supply only in replacement on load change over switch in steel sheet enclosure, 4 pole of capacity 200 Amps complete all as specified and directed.
Supply only in replacement on load change over switch in steel sheet enclosure, 4 pole of capacity 400 Amps complete all as specified and directed.
M&L in replacement for earthing with Galvanised iron earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top of earth plate not less than 1.5 mtr below GL connected to GI strip of size 25x6 mm connected to earth plate electrode by means of GI nuts, bolts, and washers with and incl, PCC 1:3:6 type C-1 pit with cover of RCC 1:2:4 type B-1 reinforced with welded steel wire fabric not less than 4 Kg per Sqm, watering arrangements with 20mm dia GI medium grade pipe, GI funnel with GI mesh, filling with mixture of common salt and charcoal, necessary excavation and earth work in any type soil, including test point, testing and commissioning complete all as specified and directed. Note: GI strip upto 7.5 mtr will be included in quoted rate.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in pole foundation complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in pole coping including necessary form work for fair finish surfaces complete all as specified and directed.
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) at bottom in true vertical position including dismantling of existing unserviceable pole complete all as specified and directed. Note: Excavation, earth work & PCC for foundation shall be measured and paid separately.
M&L for stay assembly comprising of 7/8 SWG galvanised stay of standard wire of reqd length fixed to pole with and including MS flat iron clamps, bolts, nuts and washers etc including galvanised steel 14mm dia, 400mm long stay bow and GI stay plate of size 300x300x6 mm thick, thimble MS clamp made out of 50x6mm and loop insulators porcelain brown complete all as shown in EP No.1 of SSR part - I including all accessories and excavation, earth work and PCC work including taking down old stay assembly complete all as specified and directed.
M/s Suresh Traders
M/S DIVYA TRADERS
Hindustan Power Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .