| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC D 249 GREEN ESTATE A2Z BUILDER DEVELOPERS NH 58 ROORKEE ROAD MODIPURAM MEERUT UP 250110 | MEERUT | MEERUT | UP | 250110 | L1 | Accepted-AOC Accepted and admitted being L1 | |
| 2 | L2₹13.8 L+₹1.3 L (10.8%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.0 L+₹2.5 L (20.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹15.2 L+₹2.7 L (21.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹20.0 L+₹7.5 L (60.5%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
29 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North)
GE (North) Meerut Cantt PIN 250001
CLEANING OF SEWAGE LINE SEPTIC TANKS, SOAKAGE WELL UNDER ZONE II AND ZONE III OF UNDER AGE BR I OF GE NORTH MEERUT CANTT
2021_MES_426382_1
8225/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut
Class E
Category a i
13 documents required · 13 mandatory
₹500
₹50,000
Yes
31 May 2021
27 Feb 2021
31 Mar 2021
27 Feb 2021
29 Mar 2021
15 Mar 2021
60 days
Amount
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m depth in soft/ loose soil for foundation etc or for shaft, wells, manholes,pier holes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out and levelling of bottom surface to required level complete all as specified and directed.
Returning ,filling in including spreading ,levelling watering and well ramming of soft/loose soil in layers n exc 25 cm thick each complete all as specified and directed.
Removing excavated material ( spoil ) not exceeding 50 m distance and depositing where directed at a level n exc 1.5 metre above the starting point complete all as specified and directed.
M& L for providing Cement concrete 1:4:8 Type D 2 (using 40 mm graded crushed stone aggregates) ,in foundations, filling and mass concrete complete all as specified and directed.
M&L for providing Cement concrete 1:2:4 Type B1 (using 20 mm graded crushed stone aggregates) in suface channels and drains including necessary form work, stops, moulds etc complete all as specified and directed.
M&L for providing cement concrete 1:3:6 Type C-1 (using 20 mm graded crushed stone aggregates) in cills, copings, kneelers, bed plates, kerbs hold fast, fillings in pressed steel door frame and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
M&L for providing reinforced cement concrete 1:2:4 (nominal mix) type B 1 (using 20 mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M &L for Brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in Cement mortar 1:4 complete all as specified and directed.
M&L for flat fair finished formwoark to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20 cm wide
M&L for flat fair finished surfaces formwoark to soffits of suspended slab such as roof slabs, floors slabs, landing & similar work not exceeding 200mm thick (Horizontal or sloping) etc all as specified and directed
Supply only Integral water proofing compound (I.S.I marked on packing)complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality conforming to Fe- 415, Fe 500 or Fe-550 as in steel reinforcement for concrete complete all as specified and directed. Note :- Weight of binding wire shall not be considered for measurement and payment purpose.
All as per Srl item No 12 here-in-before but 6mm to 8mm dia
M & L Non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed".
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B1 (Using 20 mm graded stone aggregate) as in floors finished even & smooth with out using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and directed.
M&L for rendering 15mm thick cement plaster with cement mortar (1:4) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement with using water proofing compount (@ 3% of weight of cement) Note :- Water proofing compound will be measured and paid seperately.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm / 600mm long complete all as specified and directed.
Supplied and fixed 110mm bore UPVC(SWR) pipes single socketed in any length with rubber ring joint, laid in trenches/under floor complete all as specified and directed.
Supplied and fixed 110mm bore UPVC(SWR) pipes single socketed in any length with rubber ring joint, fixed to walls complete all as specified and directed.
Supplied and fixed 75 mm bore UPVC(SWR) pipes single socketed in any length with rubber ring joint laid in trenches/under floor complete all as specified and directed.
Supplied and fixed UPVC (SWR) bends 110 mm bore complete all as specified and directed
Supplied and fixed UPVC (SWR) bends 75 mm bore complete all as specified and directed
Supply and fixing in repairs vitreous china squatting pan, Orissa' pattern, size 580 x 440mm white, with integral foot rests with and including cast iron 'P' or 'S' trap and setting the trap and pan in and including PCC 1:4:8, type D-2 minimum 150mm thick all round and finished just below level of rim of pan to receive the floor finishing, making all connections complete all as specified and directed.
Supply and fixing in repairs PVC low level flushing cistern of 10 Ltr capacity syphonic action type with inlet ball valve, float and handle including PVC brackets for mounting of cistern complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (padestal pattern), white (excluding flushing cistern and flush pipe) including connection to drain or out going pipe and to flushing pipe, antisyphonage pipe etc and S/F Plastic water closet seat cover black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
M&L for providing concrete bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe in PCC 1:3:6 type C2 (using 40 mm graded crushed stone stone aggregates) complete all as specified and directed.
M&L for providing concrete bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 200 mm bore pipe in PCC 1:3:6 type C2 (using 40 mm graded crushed stone stone aggregates) complete all as specified and directed.
M&L for SGSW 'grade 'A' drain pipe 150 mm internal dia laid in trenches , jointed and tested complete all as specified and directed.
M&L for SGSW 'grade 'A' drain pipe 200 mm internal dia laid in trenches , jointed and tested complete all as specified and directed.
Cutting into existing manholes for connecting new drains,( internal dia of pipe 150 mm / 200mm ) making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished, and reforming benching as required complete all as specified and directed.
Demolition and breaking up drain pipes ( SGSW, AC or reinforced concrete ) set in cement mortar for 150 mm internal dia of pipe complete all as specified and directed.
Demolition and breaking up drain pipes ( SGSW, AC or reinforced concrete ) set in cement mortar for 200 mm internal dia of pipe complete all as specified and directed.
M&L for dewatering of soak well completely of size n.exc 3mtr dia and n.exc 6mtr depth by means of pumping out of water to movable transport like tanker (attached to tractor / truck) and disposing off the water out side of defence land complete all as specified and directed
M&L for dewatering of soak well completely of size n.exc 1.8mtr dia and n.exc 4.5mtr depth by means of pumping out of water to movable transport like tanker (attached to tractor / truck) and disposing off the water out side of defence land complete all as specified and directed
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of RCC in floors(other than ground floors) beams, chajjas, landing slab and similar suspended works and including reinforcement cut on required to facilitate demolition and removing of debris & rubbish from the site complete all as specified and directed.
Dismantling and breaking up or down PVC / AC / CI / cement drain pipe 75/100mm / 110 mm bore dia fixed in any position and including removal from the site complete all as specified and directed.
To attend and rectify sewage complaint such as blockage/ chocked WCs and also outlet PVC/CI pipe and making functional up to Ist man hole sewage line etc complete all as specified and directed any type any time between 8.30 AM to 5 PM excluding sunday & closed holiday all as specified and directed. Workers shall report daily to complaint cell at 0830 hrs Contractor or his representative collect the complaints at 0830 hrs from compliant cell of AGE B/R - I and the complaints shall be attended/make good/rectified with in 24 hrs on receipt of the complaints and info the status of the compaints at 1700 hrs every day to complaint cell. On failure of the same a panelty of Rs 200/- per day per compaint shall be charged.). Note for item No 41 & 42 : Experienced four Nos Safaiwala should be provided to attend day to day complaints for above mentioned complaints.
To attend and rectify sewage complaint such as blockage of chocked kitchen area / chocked bathroom / WHB drainage chamber including floor trap gully trap and also tightening of loose rainwater pipe and also outlet PVC/CI pipe and making functional up to Ist man hole sewage line etc complete all as specified and directed any type any time between 8.30 AM to 5 PM excluding sunday & closed holiday all as specified and directed. workers shall report daily to complant cell at 0830 hrs Contractor or his representative collect the complants at 0830 hrs from complaints cell of AGE B/R - I and the complaints shall be attended/make good/rectified with in 24 hrs on receipt of the complaints and info the status of the compaints at 1700 hrs every day to complaint cell. On failure of the same a panelty of Rs 150/- per day per compaint shall be charged.).
Disconnecting existing tanks, of capacity exc 250 Ltrs & n.exc 500 Ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and cleaning and removing all scale, foreign matters, peat, mud, dirt etc from tanks surfaces and from mouths of circuating pipes, etc hoisting the same reconnecting and re-fixing in position. complete all as specified and directed.
Disconnecting existing tanks, of capacity exc 500 Ltrs & n.exc 1000 Ltrs setting aside (or lowering if required) for repairs, cleaning, etc. and cleaning and removing all scale, foreign matters, peat, mud, dirt etc from tanks surfaces and from mouths of circuating pipes, etc hoisting the same reconnecting and re-fixing in position. complete all as specified and directed.
S&F in repairs, Ready made precast reinforced cement concrete 1:2:4 type B1, using 20mm grade stone aggregate, factory made manhole covers of size 450 x 900 x 50mm thick, set in cement mortar 1:6 complete all as specified and directed
All as per Srl item No 45 here-in-before but manhole covers of size 450 x 1200 x 50mm thick
All as per Srl item No 45 here-in-before but manhole covers of size 450 x 450 x 50mm thick
Cleaning of manholes by taking out complete sludge water solids, brick bats, polythene silt etc complete by mannually or mechanically by HCV mounted suction discharge machine, removing / disposing the entire retrieved materials outside periphery of defence land including taking off manholes cover and refixing the same after clening size of manholes 600x600 and depth upto 750mm complete all as specifed and directed.
All as per Srl item No 48 here-in-before but size of manholes 900x900 and depth upto 1000mm
All as per Srl item No 48 here-in-before but size of manholes 1200x1200mm / 1200x900mm / 1500x900mm and depth upto 1.5m
Cleaning and maint of sewage line of size 75/100mm dia incl removing of all types of blockage of any length between two any consecutive manhole and to keep smooth functoining without any blockage and in any situation with manually or mechanically process incl removel and covering to existing man hole complete all as spefied and directed
All as per Srl item No 51 here-in-before but bore of pipe 150mm
All as per Srl item No 51 here-in-before but bore of pipe 200mm
All as per Srl item No 51 here-in-before but bore of pipe 300mm
Cleaning of septic tank up to 25 users capacity by mannually/Machanically in the following steps:- (i) Dewatering of septic tank (ii) Removing of all sludge/waste material from all chambers of the septic tank, clean the floor and walls of the tank after removing complete sludge/materials with clean water (iii). Removing the temprary blockage of inlet/outlet pipe and making functional the septic tanks. (iv) Remove all taken out sludge/ waste materials in covered containers out side the Defence Land. by any means and getting out and removing sludge to a distance up to 3 km out side of defence land complete all as specified and directed.
Cleaning of septic tank above 25 users and up to 50 users capacity by mannually/Machanically in the following steps:- (i) Dewatering of septic tank (ii) Removing of all sludge/waste material from all chambers of the septic tank, clean the floor and walls of the tank after removing complete sludge/materials with clean water (iii). Removing the temprary blockage of inlet/outlet pipe and making functional the septic tanks. (iv) Remove all taken out sludge/ waste materials in covered containers out side the Defence Land. by any means and getting out and removing sludge to a distance up to 3 km out side of defence land complete all as specified and directed.
Cleaning of septic tank above 50 users and up to 100 users capacity by mannually/Machanically in the following steps:- (i) Dewatering of septic tank (ii) Removing of all sludge/waste material from all chambers of the septic tank, clean the floor and walls of the tank after removing complete sludge/materials with clean water (iii). Removing the temprary blockage of inlet/outlet pipe and making functional the septic tanks. (iv) Remove all taken out sludge/ waste materials in covered containers out side the Defence Land. by any means and getting out and removing sludge to a distance up to 3 km out side of defence land complete all as specified and directed.
Cleaning of septic tank above 100 users and up to 200. users capacity by mannually/Machanically in the following steps:- (i) Dewatering of septic tank (ii) Removing of all sludge/waste material from all chambers of the septic tank, clean the floor and walls of the tank after removing complete sludge/materials with clean water (iii). Removing the temprary blockage of inlet/outlet pipe and making functional the septic tanks. (iv) Remove all taken out sludge/ waste materials in covered containers out side the Defence Land. by any means and getting out and removing sludge to a distance up to 3 km out side of defence land complete all as specified and directed.
Cleaning of septic tank above 200 users and up to 300 users capacity by mannually/Machanically in the following steps:- (i) Dewatering of septic tank (ii) Removing of all sludge/waste material from all chambers of the septic tank, clean the floor and walls of the tank after removing complete sludge/materials with clean water (iii). Removing the temprary blockage of inlet/outlet pipe and making functional the septic tanks. (iv) Remove all taken out sludge/ waste materials in covered containers out side the Defence Land. by any means and getting out and removing sludge to a distance up to 3 km out side of defence land complete all as specified and directed.
Manglam Engineers and Construction Co
M/s D.K.Enterprises
H.B. Traders
A V ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .