Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹20.9 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹23.6 L+₹2.7 L (12.8%)Rejected-Finance 21 333 031 | JHUNJHUNU | RAJASTHAN | 333031 | 2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | sihag construction L2 | MANIS AND COMPANY L1 |
|---|---|---|---|---|---|
| 1.00 | Providing and fixing aluminium body Cam Action Slide Channel Overhead hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment and 90 degree stop arrangement, of approved quality and make with necessary accessories and screws etc. complete. | 4 | Each | 1,600 ₹6,400 Lowest | 1,749 ₹6,996 |
| 2.00 | Providing and fixing bright SS finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of stainless steel 304 lever handles of approved quality and make with necessary screws etc. complete. | 4 | Each | 1,900 ₹7,600 | 1,499 ₹5,996 Lowest |
| 3.00 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. | - | - | - | - |
| 3.10 | Hot finished welded type tubes | 160 | Kg | 128 ₹20,480 Lowest | 139 ₹22,240 |
| 4.00 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. | 110 | Kg | 120 ₹13,200 Lowest | 149 ₹16,390 |
| 5.00 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : | - | - | - | - |
| 5.10 | Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60 | 30 | Sqm | 1,650 ₹49,500 Lowest | 1,749 ₹52,470 |
| 6.00 | 15 mm cement plaster on rough side of single or half brick wall of mix before placing fibre glass mesh 150 mm wide of approved quality at joint of RCC and brickwork or as required as per direction of Engineer-In-Charge | - | - | - | - |
| 6.10 | 1:4 (1 cement: 4 coarse sand) | 15 | Sqm | 390 ₹5,850 | 349 ₹5,235 Lowest |
| 7.00 | French spirit polishing : | - | - | - | - |
Tender Value
₹21.5 L
EMD Value
₹44,000
Closing Date
10 Sept 2025, 3:00 pmClosed
Sr SE
CSIR CEERI PILANI
Civil and Electrical renovation of Conference room at CSIR-CEERI, Pilani
2025_CSIR_247307_1
14/496/2025-CE
Open Tender
Construction Works
Item Rate
120 days
CSIR CEERI PILANI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
DIRECTOR CSIR CEERI
₹44,000
13 Oct 2025
3 Sept 2025
11 Sept 2025
3 Sept 2025
10 Sept 2025
3 Sept 2025
Amount
Providing and fixing aluminium body Cam Action Slide Channel Overhead hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment and 90 degree stop arrangement, of approved quality and make with necessary accessories and screws etc. complete.
Providing and fixing bright SS finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of stainless steel 304 lever handles of approved quality and make with necessary screws etc. complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge and as per manufacturer's specification, with all 4 side tapered and backed by acoustical tissue with NRC value not less than 0.60
15 mm cement plaster on rough side of single or half brick wall of mix before placing fibre glass mesh 150 mm wide of approved quality at joint of RCC and brickwork or as required as per direction of Engineer-In-Charge
1:4 (1 cement: 4 coarse sand)
French spirit polishing :
Two or more coats including a coat of wood filler ,scraping of existing surface with sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required and including water thinnable priming coat with cement primer, to achieve even shade & colour and scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Two or more coats
Taking out existing wooden door/window shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of heavy duty hinges (stainless steel) with screws and making opening of size upto 300mmx300mm with fixing 5 mm float glass supported by same exing wooden beading etc. as required, all complete as per the direction of the Engineer-in-charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within CEERI campus lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing brick work,stone work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within CEERI campus lead as per direction of Engineer - in - charge.
In cement mortar
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within CEERI campus as per direction of Engineer-In-Charge.
Providing and Fixing of Fibre Glass Acoustical Suspended Ceiling System with 15mm thick Microlook 90 Edge Tiles with 15mm Bolt Slot exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 20/25mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%.SUSPENSION: The tile shall be laid on grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour with mitred ends & “bird’s mouth” notches to provide mitred cruciform junctions colour global white. Grid shall have double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 7.9 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 9.5 kg/m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of 90 gsm as per IS 277 (2003) pre-painted steel with baked polyester paint of 0T bending capability. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall.
Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners
Providing and Fixing Channelled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side with backfill upto 75 mm thick Resin Bonded Rockwool 48 kg/m3 as per requiments. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 5mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.65. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by approved brand as per direction of Engineer-in-Charge. Properties of material Relevant Standards Base Material Moisture Resistant Medium Density Fibre board Panel Dimensions 2400mm x 192mm x 15mm Panel Weight ≅ 8.5kgs/m2 Perforation Details “Helmholtz” fluted perforation on reverse side with consecutive of 3mm wide groove followed by 5mm of visible pane.Panel Finish Laminate (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) finish Noise Reduction Co-efficient 0.65 ASTM C423 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) Humidity Resistance RH 70% Dimensional tolerances ± 5mm The panel shall be mounted by tongue and groove mechanism using inside clip on aluminium extruded keel made of Grade 6063-T5 having dimensions 3000(L) x 24(H) x 15.5(W). The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. Installation System Details Aluminium Keel/ Transition Profile Base Material Extruded Aluminium Grade 6063-T5 Construction Method Aluminium Extrusion Dimensions 3000(L) x 24(H) x 15.5(W) mm Accessories Clip Inside Clip
INSTALLATION: An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface for fixing Keel. Install Keel vertically using screws and plugs at spacing of not more than 600mm centre-to-centre. The first and last keel should not be more than 150mm from the ends. Trim the tongue of the first bottom panel and install using headless nail with groove side upward. Subsequent panels are installed with tongue side downward by engaging with each other using tongue and groove mechanism and secured by inside clip. Continue this process until required height is achieved. Shorter butt edges need to be joined using industrial/wood glue. The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. Install the skirting of width 50mm or more as required as per direction of Engineer-in-Charge. Finish off the edges using wooden moulding of matching colour. Installation should be carried out as per approved brand recommended procedure.
Supply and installation of 2.50 mm thick approved Linoleum flooring as per EN 428, made of natural raw material which is permanently bacteriostatic flooring of approved make as per manufacturers specifications.The product has Top shield finish comprising of primer and Acrylic coating to provide better performance.The product should not have a PUR coating on the top surface.The joints between the flooring shall be hot seamed /welded using multicoloured welding rods(similar to the shade of floor covering as per manufacturers approval after 24 hours of laying of rolls.The welding/seaming shall be done using hot air welding machine.The product should have accoustical sound impact of 19db.Reaction to fire should be EN 13501-1Cfi-SI. as per approved make , manufacturer's specification and as per direction of Engineer-in-charge
Providing and applying one coat of cement based ready made wall putty including preparing the surface smooth by san papering etc as per directions of the Engineer-in-charge. Consumption of the putty shall be not less than 5 Kg per 10 Sqm. Preperation and application of the putty shall be strictly as per the manufacturers guidelines and as per the directions of the Engineer-in-Charge. The putty shall be applied only after cleaning the surface thoroughly. Required curing shall be done before application of both the coats shall also be sand papered to make the surface smooth and even suitable for any kind of wall painting. The rate includes all operations and all the material and necessary scaffolding etc. Complete as per direction of Engineer-In-Charge.
Supply and Installation of 3mm average thick self leveling compound of approved brand required for linoleum flooring etc. Complete as per direction of Engineer-In-Charge.
Supply and Installation of 12 mm thick skirting High-Density High Moisture Resistance board of approved brand and shade colour.The rate shall include the cost of fixing with headed nails and adhesive etc. complete as per direction of Engineer in Charge.
Part-II Electrical Work: -POINT WIRING Rewiring for light/fan/exhaust fan point with 1.5 sq. mm FR PVC insulated flexible copper conductor 1.1 KV grade and 1.5 sq .mm FR PVC insulated flexible earth copper conductor 1.1KV grade IS: 694 only of approved make (Group-1) in existing surface/recessed conduit pipe including dismantling of existing wiring, switchboard of any size with accessories/fittings etc. as required.
Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C (Irrespective of any length)
Supplying and fixing following size/ modules, GI box alongwith modular base, cover & blanking plate for modular switches in recess etc. as required. etc as required.
1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supplying & Fixing of 3Pin, 5Amp. Ceiling rose on juction box with provinding round phinolic sheet, including making connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required.
10 A switch
20 A switch
3 pin 5/6 A socket outlet
Telephone socket outlet RJ 11
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3pin, 6 amps modular socket outlet with 2 Nos. 16 amp moduler switch and 1No. 6 pin 5/6 & 15/16 amps modular socket with blanking ,connection, painting etc. as required (different in colour of cover plate from general power for UPS / computer applications), making good the wall with matching colour distemper/ white wash etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch/removing recessed existing board, disconnection making connections and testing etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
2 x 1.5 Sq. mm
3 x 1.5 Sq. mm
4 x 1.5 Sq. mm
6 x 1.5 Sq. mm
8 x 1.5 Sq. mm
3 x 2.5 sq. mm
3 x 4 sq. mm
6 x 4 sq.mm
Telephone & Data Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying & Fixing of following sizes of steel conduit along with heavy duty accessories, junction box etc. in surface / recesse including painting in case of surface conduit, or cutting the wall, repair and making good the same as required.
Supplying & Fixing of following sizes of PVC conduit along with heavy duty accessories, junction box etc. in surface / recesse, or cutting the wall, repair and making good the same as required.
Supplying and drawing of 23 AWG UTP Data Cable (CAT 6) gigaspeed LAN Cable in the existing surface/ recessed Steel/ under floor trunking as required.
1 run of cable
P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts Simplex Faceplate with RJ-45, information outlet with shutter with colour coding on existing modular plate, including making connections testing etc. as required
Light and Fan Supplying of recessed mounted 35 Watt full glow, slim energy efficient, Green Square 2'x2' LED 110 lu/w, 6500 K lighting luminaires approved make complete with hanging arrengment all accessories, metallic CRCA powder coated housing etc. complete as required.
Installation, testing and commissioning of above LED tube light fittings complete with all accessories on surface of wall/ ceiling or suspended from ceiling including providing hanging arrangment with clutch wire, transperent connection wire/ 1.5Sq.mm FR PVC copper conductor etc. as required.
Supplying of Surface / Ceiling mounted LED 13.5 watt light fixture- Circuler light Surface Light, 6500 K with housing approved make including, connection wire of suitable length, all accessories etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of length upto 30 cm with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. complete as required.
Supply of 400mm size wall mounting oscilating type wall mounting fan having 3 speed push button control suitable for operation on 230volts, 50Hz, AC supply approved make complete with continuous duty, motor, chrome plated front and rear guards etc.
Installation, testing and commissioning of ceiling/ wall mounting fan, including wiring the down rods of length upto 30 cm with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. complete as required.
Cables: Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of XLPE insulated PVC sheathed 1.1 kv. Grade copper/Al. conductor armoured Cable IS: 7098 Part-1 of approved make.
2 X 10 Sqmm. Al. cable
4 X 10 Sqmm. Al. cable
4 X 50 Sqmm Al. Cable
4 X 25 Sqmm Al. Cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on wall/ roof/ duct/ shaft including fixing by means of screws & rag bolts, suitable size MS U clamps complete as per specifications, repairing works etc as reqd. of following sizes of cables.
upto 35 Sqmm.(clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on wall/ roof/ duct/ shaft including fixing by means of screws & rag bolts, suitable size MS U clamps complete as per specifications, repairing works etc as reqd. of following sizes of cables.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x2mm MS flat clamp
Supply& making one end termination with heavy duty single compression brass gland SIBG type, aluminium/ copper lugs duly crimped with crimping tool, PVC tape etc. for following size of XLPE insulated & PVC sheathed aluminium/ copper cable of 1.1 KV grade as required.
2 X 10 Sqmm.
4 X 10 Sqmm.
4 X 50 Sqmm
4 X 25 Sqmm
Distribution Boxes (Main DBs) P & F Recessed/ surface mounting vertical type heavy duty Double door type TPN-4 way sheet steel phosphatised powder painted Distribution Board with loos wire box, incomer 1No. MCCB-125A, 16KA and 12 Nos. SP AC MCB-16-32A 10KA ( 'C' breaking characteristic) for outgoing circuits, 125 Amp busbar, neutral link, earth bar & din rail etc conforming to IS; 13032, IS; 8623, BS; 5486 of approved make including making all the incoming/ outgoing connections, internal DB terminations with copper lugs, testing etc. as required.
Supplying and fixing of ,4 Way three pole and neutral, prewired, sheet steel, per phase isolation ( PPI ) MCB distribution board, 415 volts on surface / recess, complete with loose wire box, Incomer 1No. 40A, 4 Pole isolator, Outgoings- 3Nos. DP RCCB 40A, 240 volts, having a sensitivity current 30 milliamperes, 12 Nos. SP AC MCB-32A, 10KA, 240V ( 'C' curve ), terminal blocks, duly prewired with suitable size FRLS PVC insulated copper conductor upto terminal blocks, tinned copper bus bar, seperate neutral links for each phase, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted, making internal DB terminations with copper lugs including all the existing incoming/ outgoing connections, earthing, testing, repair & making good the wall with matching colour distemper/ white wash etc. as required.
Supplying & fixing following rating, 240/415 volts, "C" curve, MCB suitable for inductive load of folloing pole with suitable size MCB box encloser complete with connections, testing and commissioning etc. as required.
Double Pole 32 amp with encloser
Four Pole 32 amp with encloser
Dismantling: Labour charges for dismantling of surface/ recessed light power point switch board of any size and depositing the same with listing of material in store.
Labour charges for dismantling of all types/ industrial type tube light fixtures/exhoust fan/Ceiling fan with down rod, ball and socket arrangements from wall/ ceiling with all accessories etc. as required and depositing the same in stores.
Dismantling of existing armoured UG cables of following sizes safely from Lab room duct/ shaft/ wall/ board including disconnections & making good the damages,return back the dismantled items to store/ EME Div. etc as required.
Upto 35Sqmm.
sihag construction (BID ID -896940)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .