Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹10.3 L+₹54,000 (5.52%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹10.4 L+₹57,690 (5.90%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹10.6 L+₹79,715 (8.16%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹10.6 L+₹86,430 (8.84%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
1 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001(Punjab)
Repair and Maint to capacitor bank and misc works at Dholewal, Doraha, CG Complex, Phillaur, Baddowal and Moga under GE Ludhiana
2024_MES_641673_1
GE/LDH-66/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
DHOLEWAL, CG, DORAHA, PHILLAUR, BADDOWAL
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹20,000
Yes
7 May 2024
10 Feb 2024
4 Mar 2024
10 Feb 2024
1 Mar 2024
24 Feb 2024
10 Feb 2024 - 23 Feb 2024
Amount
Supply & fixing in replacement current transformer CT 25/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement current transformer CT 50/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement current transformer CT 75/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed .
Supply & fixing in replacement power factor controller relay latest micro controller based tech with true RMS sensing alarm available , delay adjustment , LCD display range 08 steps , 7 segment LED display size 144 X 144mm Auxillary supply 90-550 VAC, NTC tempature sensor , power factor measurement range 0.8 lag to 0.8 le suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement power factor controller relay latest micro controller based tech with true RMS sensing alarm available , delay adjustment , LCD display range 12 steps , 7 segment LED display size 144 X 144mm Auxillary supply 90-550 VAC, NTC tempature sensor , power factor measurement range 0.8 lag to 0.8 le suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 1 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 3 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 5 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 10 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 15 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement heavy duty cylindrical capacitor 20 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed.
Supply and fix in replacement capacitor duty contactor 3P, AC3 , 12 amp (2NO, 2NC) of suitable up to 5 KVAR APFC panel ratings for APFC Panels complete all as specified and as directed.
Supply and fix in replacement capacitor duty contactor 3P, AC3 , 20 amp (2NO, 2NC) of suitable up to 10 KVAR APFC panel ratings for APFC Panels complete all as specified and as directed.
Supply and fix in replacement capacitor duty contactor 3P, AC3 , 32 amp (2NO, 2NC) of suitable up to 15 KVAR APFC panel ratings for APFC Panels complete all as specified and as directed.
Supply and fix in replacement capacitor duty contactor 3P, AC3 , 40 amp (2NO, 2NC) of suitable up to 20 KVAR APFC panel ratings for APFC Panels complete all as specified and as directed.
Supply and Fixing in replacement 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed.
Supply and Fixing in replacement 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed.
Supply and Fixing in replacement 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed by Engr-in-charge
Supply and Fixing in replacement 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed by Engr-in-charge
Supply and Fixing in replacement 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed.
Supply and Fixing in replacement C Curve 3 Pole MCB 32 TO 63 Amp, 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and as directed.
Supply and fix in replacement wiring complete 6.0 Sqmm single core PVC insulated FR LS cable 1100 volts grade multistranded copper conductor cable with multistranded copper conductor cable as earth continuity conductor, all as specified and as directed .
Supply & fixing in replacement panel mounted voltmeter three phase incl with CTs/ PT ratio 4 digit display , class 1.0 in 96X96 Sq mm flush mounted case suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement panel mounted Ammeter three phase incl with CTs/ PT ratio 4 digit display, class 1.0 in 96X96 Sq mm flush mounted case suitable for APFC Panel complete all as specified and as directed
Material and labour in replacement of indicator lamp in red, yellow and blue colour with lamp holder multi LED type complete including wiring with copper conductor cable of suitable size all as specified .
M&L for painting of panel board inner & outer complete with synthetic enamel paint by spraying including filling cavaties with filler one coat after cleaning all dust/rust including writing the Distribution/Panel Number and panel details all as directed .. Note: The Quoted rates are inclusive of white wash to fountation of Panel Board/ Painting to Angle Frames complete
Supplying and laying synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006,(supersending IS 5424) suitable for electrical shock safety of size 2mx1 m all as specified
Supplying and laying synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006,(supersending IS 5424) suitable for electrical shock safety of size 2mx1 m all as specified
Supply & fixing in replacement current transformer CT 400/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement current transformer CT 160/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed.
Supply & fixing in replacement current transformer CT 100/5A CL 1 5VA Spare suitable for APFC Panel complete all as specified and as directed .
Supply & fixing heavy duty cylindrical capacitor 25 KVAr, 3 Phase, 440 V , 50Hz suitable for APFC Panel complete all as specified and as directed.
Supply and Fixing in replacement 3 Pole MCCB 63 TO 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and as directed.
Supply and Fixing in replacement 3 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed by Engr-in-charge.
Supply and Fixing in replacement 3 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed.
Supply and Fixing in replacement 3 Pole MCCB 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and as directed.
Supply and Fixing C Curve TPN MCB 16 to 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and as directed by Engr-in-charge
Supply and Fixing C Curve TPN MCB 40 to 100 Amp, 50 Hz, 415 V with rupturing capacity 10 KA complete all as specified and as directed by Engr-in-charge
Supply & fix PVC exhaust fans (8") AC single phase 150 mm sweep with louver all as specified.
M/S Pee Kay Builders
M/s Mukand Lal Khanna
M/S N Maini Constrution
B.L. Chaudhri and Co.
shivam builders
M/s Bansi Lal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .