Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹24.6 L+₹1.8 L (7.77%)Rejected-Finance DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹24.6 L+₹1.8 L (7.82%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹25.5 L+₹2.7 L (11.8%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹29.4 L+₹6.6 L (28.9%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
5 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
CERTAIN REPAIRS TO SERVICE DUCTS AND RELATED WORKS AT IN JETTY UNDER AGE E/M AT GE HADDO, PORT BLAIR
2021_MES_493908_1
8594/GE/H/PB
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Haddo, Port Blair
E b(i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹46,000
Yes
25 Jan 2022
10 Dec 2021
10 Jan 2022
10 Dec 2021
5 Jan 2022
24 Dec 2021
10 Dec 2021 - 20 Dec 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide, depth exceeding 1.5 m but not exceeding 3.0 m, for foundation of poles, stays, struts or for laying cables/pipes etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
NOTE for Item No 1 & 2: 1. If new cable is laid as replacement of old cable in the same trench, all excavation and earth work shall be measured only once. 2. If any pipe is laid in trenches as cable protection, all excavation and earth work shall be measured either for cable or for pipe only and not for both. 3. If cable is laid in tiers and in loops, all excavation and earth work shall be measured accordingly.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed.
Removing excavated material (soils) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for poles/stays/feeder pillar boxes etc., complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in copings of poles/stays including necessary form work, exposed surfaces of concrete finished even and smooth without using extra cement complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) for support complete all as specified and directed.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Lifting RCC cover slabs of size 2 to 4 metres long, 1 to 2 metres width and upto 300 mm thick and about 2.5 to 4.0 tons in weight lying on jetty (as required at suitable intervals all along the jetty) by cutting/chipping the clearance groove all around, stacking aside carefully using suitable lifting machinery/crane without causing any damage to the existing structure, carrying out cleaning of cable duct of size 2 to 4 metres in width and 1.0 metre depth, lifting and placing the cables aside, any numbers of size 3½ core x 240 to 500 Sqmm or taking slightly above the duct with and including cost of minor tools etc., pumping out the stagnated water from the duct, removing all mud/sludge and clean the entire duct, cleaning the cables and placing back in position side by side or on supporting angles and replacing the RCC cover slabs back in position over the duct at Naval wharf and pointing the joints with CM (1:2) and removing the rubbish from site to outside MD land complete all as specified and as directed. NOTE: Cover slabs at suitable intervals only need to be lifted to facilitate cleaning of jetty duct and removal of unserviceable trash lying inside the jetty duct such as cables, pipes etc., and removal/pumping out of mud and stagnated water. Each cover slab lifted shall be measured and paid as ONE UNIT (JOB) whereas cleaning of duct shall be for full length of jetty complete. The tenderer shall make note of this requirement and no claim whatsoever shall be entertained at a later stage.
Lifting of RCC cover slabs, each of size 2.0m x 1.0m (approx) and of 150mm thickness (approx) and about 0.2 to 0.6 tons in weight from position lying over cable duct or cable trench by cutting/chipping the clearance groove all around the slab, without causing any damage to the existing structure, keeping aside, carrying out cleaning of duct and laying of cables with and including cost of minor tools etc., and replacing the covers back in existing position over duct after completion of work and pointing the joints in CM (1:2) complete all as specified and as directed. NOTE: Each cover slab lifted shall be measured and paid as ONE UNIT.
Disconnecting old serviceable HT/LT UG cables of size 3 core / 3½ core, 120 to 500 Sqmm from its connections, drawing out from the pipe underneath jetty slab from power house to jetty, jetty to cope box points, checking the cable for faults with megger, rectifying the faults, if any by using cable joints and re-using the serviceable cable in the same location by drawing through pipes fixed with suitable clamps/saddles and connecting up with suitable size of lugs, glands and jointing material complete all as specified and as directed. NOTE: Removal of jetty slab covers and replacing back in position shall be measured and paid separately under relevant item of this BOQ.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 300 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 400 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 500 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 4 core, 16 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 4 core, 25 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 50 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed.
M&L for LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 3½ core, 70 Sqmm laid in trenches/floors/ducts or fixed on poles/walls with suitable clamps/saddles or drawn through pipes etc., and connecting up with suitable size of lugs, glands and jointing material including taking out old unserviceable cable complete all as specified and as directed. NOTE for all items of cable: 1. Cable test results like continuity test, megger test shall be submitted to Engr-in-charge before the cable is laid. 2. Necessary excavation and earth work shall be measured and paid separately under relevant items of this schedule.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for mild steel chequered plates conforming to Fe-410-W (Gde-E-250) Quality 'A', of any thickness by cutting/ making into required shape, providing necessary angular supports and handles with 6 mm dia rod as per the site conditions by welding etc., including painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and laid over cable trenches of various substations including dismantling old unserviceable ones complete all as specified and as directed.
M&L for Cast iron fittings (specials) such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing of double socket etc), Tee pieces, single branch, Y-junction, double branch, tail piece, cross (all sockets or spigot and socketed ends), collars, caps and plugs up to 150mm dia or bore of pipe complete all as specified and as directed. MAKE: ELECTRO STEEL CASTINGS/ TISCO/ KESORAM/ JINDAL
M&L for Cast iron fittings (specials) such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing of double socket etc), Tee pieces, single branch, Y-junction, double branch, tail piece, cross (all sockets or spigot and socketed ends), collars, caps and plugs from 200 to 250mm dia or bore of pipe complete all as specified and as directed. MAKE: ELECTRO STEEL CASTINGS/ TISCO/ KESORAM/ JINDAL
S&F Galvanised iron strip 32x6mm buried in ground or fixed to walls/poles with necessary clamps, bolts and nuts including taking down old unserviceable strip complete all as specified and as directed.
M&L for preparation of old painted surfaces of LT panels/ feeder pillar boxes by cleaning/rubbing with coarse cloth/ wire brushes to remove dust deposits, oil, grease, levelling the undulations using oil putty and painting by applying one spray coat of synthetic enamel paint of existing tint without disturbing/ damaging the electrical net work system/ equipment including marking the details such as capacity/ rating/ incoming/ outgoing/ Danger notice board in capital English alphabets with red colour radium sticker of required size complete all as specified and as directed.
Fabricate, supply, install, test and commissioning of cope box of size 0.9mx0.6m and 1.0m height made out of 50x50x6mm angle iron frame covered with 6mm thick aluminium sheet all over fixed with stainless steel bolts, nuts and washers, provision for bottom cable entry, top opening hinged lid with handle and two side canopy with cable entry 06 Nos and copper bus bars of 2000 Amps capacity and with cable entry 03 Nos and copper bus bars of 800 Amps capacity and bakelite sheet of 20 mm thick, 80 cm (2x40cm) long as separators of bus bars, cope box mounted over existing RCC jetty slab by making necessary cutting, chipping and making good the disturbed surfaces and finally connecting to existing cables including taking out old unserviceable cope box complete all as specified and directed.
Material and labour for laying Cast iron pipes with flanged ends, centrifugally cast, class B of size 200mm bore , in any length laid in trenches / ground complete all as specified and as directed
Material and labour for laying Cast iron pipes with flanged ends, centrifugally cast, class B of size 150mm bore , in any length laid in trenches / ground complete all as specified and as directed
Material and labour for laying Cast iron pipes with flanged ends, centrifugally cast, class B of size 100mm bore , in any length laid in trenches / ground complete all as specified and as directed
S&F mild steel section as in support/ staging/chamber cover along with breaking support, clamps and fabricated back plate including nuts and bolts including welding and bending, cold and hot drill holes for bolts, in any shape or size as indicated or directed complete all as specified and as directed.
Supply & install steel tubular pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS2713 (part-I) 1980 made out of MS tubing including painting of two coats of synthetic enamel aluminium paint of approved quality over one coat of red oxide primer length 11.00 mtr long 410 SP -55 for stud pole all as specified.
Disconnecting all electrical connections of LT panel boards/ pillar boxes of 415 / 380 / 230 Volts, 3 phase with bus bar chamber and decarbonising / cleaning complete LT panel boards/ pillar boxes after removing the complete bus bar from the bus bar chamber, cleaning with CTC and ensure proper decarbonising including new bakelite of adequate size where ever required re-fixing the same bus bar and re-connecting all cables with new aluminium lugs of suitable size after applying Becktrol (Red) solution to the spout, checking all the connections, tightening the nuts, bolts, thimbles for incoming and outgoing system complete including renewal of defective/ rusted bolts, nuts, insulators etc. complete all as specified and as directed by Engineer in charge.
M&L for servicing of 10 to 20 Ton capacity EOT/HOT crane by taking down the pulley blocks and winch assembly including gear shaft and chains followed by greasing, oiling and overhauling and checking for defects in wheel mechanisms for horizontal and transverse movements including rectification of defects and checking the rails for crane movement and alignment the same including bending, fabrication by welding including necessary reinforcement and connected PCC work and painting the HOT/EOT crane complete including brackets, cross members etc. with two coats of synthetic enamel paint over a coat of red oxide primer after due cleaning of the entire surface and testing complete all as specified and as directed by Engineer-in-charge.
M&L for servicing of 2 to 5 Ton capacity EOT/HOT crane by taking down the pulley blocks and winch assembly including gear shaft and chains followed by greasing, oiling and overhauling and checking for defects in wheel mechanisms for horizontal and transverse movements including rectification of defects and checking the rails for crane movement and alignment the same including bending, fabrication by welding including necessary reinforcement and connected PCC work and painting the HOT/EOT crane complete including brackets, cross members etc. with two coats of synthetic enamel paint over a coat of red oxide primer after due cleaning of the entire surface and testing complete all as specified and as directed by Engineer-in-charge.
Taking out old unserviceable butterfly valve and S&F new MS butterfly valve of 80 mm dia, heavy duty, side handle operated complete all as specified and directed.
Taking down old unserviceable hydrant valve and Supply and fixing of Single Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm to 80mm dia oblique type with instantaneous hose coupling adaptor etc. with all necessary fitting materials complete required at site complete all as directed.
Taking down old unserviceable hydrant stand post and Supply, Installation and Testing of new Yard Fire hydrant stand Post of 80mm dia GI / MS both flanged type 1.5m Height both ends flanged with one end bend to 90 degrees suitable for long single fire hydrant valves including duck foot bend double end flanged and sluice valve all as specified and directed.
Taking out old Sluice valve of size 150/200mm bore, cast iron both ends flanged for repairs like cleaning, greasing and replacement of brass/stainless steel spindle and check nut including re-fixing of sluice valve with new Rubber gasket, stainless steel nuts, bolt and washers etc complete all as specified and directed.
Taking out old Sluice valve of size 80/100mm bore, cast iron both ends flanged for repairs like cleaning, greasing and replacement of brass/stainless steel spindle and check nut including re-fixing of sluice valve with new Rubber gasket, stainless steel nuts, bolt and washers etc complete all as specified and directed.
M&L for taking out old U/s foot valve of size 150/200mm size by disconnecting the existing CI/GI Pipes from fire fighting pump sets of capacity upto125 HP using suitable chain pulley system all as required as per site conditions and to carry out repairs like cleaning, greasing and replacement of leather washer including re-fixing of foot valve with new rubber gasket, stainless steel nuts, bolt and washers etc, including reconnecting of suction line of pump set using nuts, bolt and washers or by welding complete and testing the pump set complete at Sea water pump houses complete all as specified and directed. Note:(a) Cost of all spares shall be deemed to be included in the quoted rate. (b) Cost of equipments /T&P required for the work , including transportation to site shall be included in the quoted rate. (c) Contractors are advised to visit the sites before quoting the rates.
M&L for taking out old U/s foot valve of size 50 to 100mm size by disconnecting the existing CI/GI Pipes from fire fighting pump sets of capacity upto125 HP using suitable chain pulley system all as required as per site conditions and to carry out repairs like cleaning, greasing and replacement of leather washer including re-fixing of foot valve with new rubber gasket, stainless steel nuts, bolt and washers etc, including reconnecting of suction line of pump set using nuts, bolt and washers or by welding complete and testing the pump set complete at Sea water pump houses complete all as specified and directed. Note:(a) Cost of all spares shall be deemed to be included in the quoted rate. (b) Cost of equipments /T&P required for the work , including transportation to site shall be included in the quoted rate. (c) Contractors are advised to visit the sites before quoting the rates.
M&L for suction strainer/foot valve of size 150mm dia complete all as specified and directed.
S&F in repairs of GI Pipe 100mm dia medium grade, outside with red/blue in colour including necessary fittings like bends, elbows, unions, tees, nipples etc complete all as specified and as directed by Engineer- in- charge.
S&F in repairs of GI Pipe 80mm dia medium grade, outside with red/blue in colour including necessary fittings like bends, elbows, unions, tees, nipples etc complete all as specified and as directed by Engineer- in- charge.
Taking out old U/S sluice valve complete including fittings and Supply and fixing of 200 mm bore Sluice valve cast iron both ends flanged of class 1.6 PN, ISI marked with stainless steel spindle including joints and jointing material (Rubber gasket, stainless steel nuts, bolt and washers etc) complete all as specified and directed.
Taking out old U/S sluice valve complete including fittings and Supply and fixing of150 mm bore Sluice valve cast iron both ends flanged of class 1.6 PN, ISI marked with stainless steel spindle including joints and jointing material (Rubber gasket, stainless steel nuts, bolt and washers etc) complete all as specified and directed.
Taking out old U/S sluice valve complete including fittings and Supply and fixing of 100 mm bore Sluice valve cast iron both ends flanged of class 1.6 PN, ISI marked with stainless steel spindle including joints and jointing material (Rubber gasket, stainless steel nuts, bolt and washers etc) complete all as specified and directed.
Supply and fix fire hose cabinet made out of 18 gauge MS sheet but not less than 800 x 600 x 250mm with double door with 4mm thick glass and door frame made out of 16 gauge MS sheet painted with two coats of epoxy paint of fire red colour for external faces and brilliant white for inside faces over a coat of red oxide all as per directed.
S&F Controlled Percolating Hose 15 Meter length all as specified and as directed
M&L for surface cleaning 200/250mm dia CI/DI Pipe with wire brush, emery paper, removing dust dirt, washing with water, cleaning, drying surface and applying two coat of synthetic paint (Post Office Red colour) over a coat of red oxide all as directed.
M&L for surface cleaning 150mm dia CI/DI Pipe with wire brush, emery paper, removing dust dirt, washing with water, cleaning, drying surface and applying two coat of synthetic paint (Post Office Red colour) over a coat of red oxide all as directed.
M&L for surface cleaning 63mm fire hydrants with wire brush, emery paper, removing dust dirt, washing with water, cleaning, drying surface and applying two coat of synthetic paint (Post Office Red colour) over a coat of red oxide all as directed.
Supply and fixing Pressure gauge 4" dial having pressure rating of 0-21kgs complete all as specified and as directed by Engineer-in-charge.
M& L for fabricating, installing fire stand duly made with angle iron/GI pipe structure of size 2 mtr x 1.5 mtr including slopping top 1.6 mm thick MS sheet at either sides with provision for hanging 6 Nos Fire buckets incl mounting hook etc complete duly painted with 2 coats of PO red and grouting the supporting legs in PCC 1:3:6 at a location shown at site including dismantling of old structures and comprising of the following: a) GI fire bucket - 6 Nos b) Fire beater - 1 No c) Fire hook - 1 No d) ABC type fire Extinguisher of 5 Kg - 2 Nos e) Foam type fire Extinguisher of 5 Kg - 2 Nos f) CO2 type fire Extinguisher of 5 kg - 2 Nos
Material and labour for preparation of old painted surface of Diesel Driven fire pump set / electrical driven pump set of capacity upto 150 HP by scraping out old painted surfaces and painting with spray painting of gray colour synthetic enamel paint over two coat of red oxide primer all as directed by Engr-in-Charge.
Supply and fix in repairs maintenance free lead acid battery 12 volts, 24 plate, 180 AH and outer case having the low/high electrolyte indication.
M&L for Overhauling of fire fighting pump set of capacity 150 HP after removing from base plate disconnecting from pipe line and dismantling pump set, replacing gland packing, gun metal bush, bearing and water seal and applying grease etc, reassembling the pump set and refixing back on the base plate and connecting with existing pipe line with nuts, bolts and new gasket including dismantling the motor, cleaning the rotor, starter, varnishing, backing etc and reassembling the motor and painting motor and pump sets including suction and discharge pipe line with one coat of paint with spray painting also connecting the existing cable etc. including testing the pump set for full satisfaction of in -charge, complete all as specified and as directed by Engineer-in-charge.
M&L for Mechanical seals suitable for 150 HP pump sets to prevent leakages all as per OEM recommendations (Make:Kirloskar) all as specified and as directed
Annual maintenance / servicing and replacement of unserviceable consumable items of reverse osmosis water purifier of capacity 1000 Ltrs/Hrs installed at various locations, by rectifying any type of blockage, loose connection in electric and electronic components of plants, servicing of the plant to be carried out complete all as specified and directed. Make of Water Purifier: Delta Ion Exchange or equivalent NOTE:- (i) All the spares / components required for the repair and servicing shall be included in the quoted rate (ii) Quoted rate shall include technician charges (iii) This item shall be executed as and when required.
Laying only HT/LT UG cables of size 3 / 3.5 Core 120 to 500 Sqmm removed under item No.11 above and placing the removed cables in the same duct after meggering of cables with necessary clamping where required complete all as specified and directed
PTech Engineers
SRI HARSHITA ELECTRICALS
A. R. ELECTRICALS
NAVJEEVAN ENTERPRISES
Sree Tirumala Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .