| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹10.3 L+₹80,670 (8.54%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹10.4 L+₹94,070 (9.95%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹10.9 L+₹1.5 L (15.5%)Rejected-Finance MALANGPORA MALANGPORA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹11.1 L+₹1.6 L (17.4%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
7 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
CERTAIN REPAIR TO INTERNAL ELECTRIFICATION INCLUDING FITTING AND FIXTURE IN OTM ACCN, DOMESTIC AND TECHNICAL AREA AT 8 FBSU, AF STATION AWANTIPUR
2020_MES_361666_1
GE (AF) AWA -10/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹32,000
Yes
18 Aug 2020
17 Jul 2020
10 Aug 2020
17 Jul 2020
7 Aug 2020
31 Jul 2020
60 days
Amount
Taking down carefully aluminium/copper point wiring (light, bell, fan, socket) complete including batten/casing caping/conduit, block, ceiling rose, holder, fittings and terminal box sheets complete, stacking material at site and making good the disturbed surface of walls/ floors to match with existing surface, complete all as specified and directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping, ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel terminal boxes made out of MS sheet duly painted with two coats of black bituminous paint over a coat of red oxide primer with 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and as directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one No, one way switch on same board.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent, controlled by one No. one way switch on independent board.
Description all as per serial item No. 2 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and as directed.
Point wiring with two single core PVC insulated, unsheathed, FR type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in existing conduit including one single core multistanded PVC insulated FR type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and as directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one No, one way switch on same board.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent, controlled by one No. one way switch on independent board.
Description all as per serial item No. 4 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 1.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified.
Piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed.
Piano type bell push switch, one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and as directed.
Piano type socket outlet, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and as directed
Piano type switch socket combination, flush type, 6 pin, 6/16 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and as directed.
Electronic type ceiling fan regulator, 230 volts, single phase, flush type, complete all as specified and as directed.
Ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body, 230 volts AC, 50 Hz, complete all as specified and as directed.
Electric call bell, ding dong type suitable for 230 volts, single phase AC supply, complete all as specified and as directed.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in and including casing caping of suitable size and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in existing conduit with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 4Sqmm cable shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified. Note :- 2 +1 run of 6Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in existing conduit along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 6Sqmm cable shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 10sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and as directed. Note :- 2 +1 run of 10Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of existing DB's double door With new factory made load line DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link and earth link suitable for MCCB TP as incomer and MCB SP/TP as out going complete with and including one No. MCCB 100 Amps, 3 pole, 25 kA fixed type for incoming, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 2 way, single door, 230 volts AC, surface mounting complete with suitable for MCB SP/SPN, fixed in repair, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB TP/TPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 12 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and as directed.
Replacement of existing Sheet steel plug & socket DB's with new Sheet steel plug & socket DB's SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, concealed type, complete with & including one MCB SP, 20 Amps, 10 kA, including grouting in wall and making good to disturbed surfaces to match existing, complete all as specified and as directed.
MCB SP, 10-32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and as directed.
MCB SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and as directed.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type,fixed in repair, complete all as specified and as directed.
MCB TPN, 40-63 Amps, 415 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and as directed.
Replacement of existing LED tube light fitting with new LED tube light fitting box type 230 volts AC suitable for & including 18/20 watts LED tube rod with bipin holders prewired, LED driver including making of electrical connection with & including three core flexible copper conductor cable of suitable size, ccomplete all as specified and as directed. Make: Havells Model: Regal batten for Fitting and Photon Ultra LED for tube rod or equivalent in Philips/Crompton.
Replacement of existing LED surface mounted light fitting with new LED surface mounted light fitting diecast body , round shape 6W 230 volts, 50Hz, including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessories, complete all as specified and as directed. Make: Havells model: Comet ROUND, cat part No.LHEAAVP7IL1W006 or equivalent in Crompton/Philips.
Replacement of existing LED tube light fitting with new ED tube light fitting box type 230 volts AC suitable for & including 8 watts LED tube rod including bipin holders prewired, LED driver including making of electrical connection with & including three core flexible copper conductor cable of suitable size, complete all as specified and as directed. Make of fitting: Crompton model: Mirrorlite or equivalent in Havells/Philips and make of LED tube: Compton model: Retro LED or equivalent in Havells/Philips.
Replacement of existing recess mounting LED light fitting with new recess mounting LED light fitting 36W, 230 volts AC suitable for armstrong/grid ceiling, glare free symmetrical illumination type complete with LED driver, lamp suitable for cutout of size 600mmx600mm including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessories, complete all as specified and as directed. Make: Crompton cat part No. LCTLRN-36-FO-CDL or equivalent in Philips /Crompton.
Replacement of existing LED wall light fitting with new LED wall light fittings 9 watt, 230 volts AC, indoor type made up of polycarbonate complete with B-22 type lamp holder, LED Lamp 9 watts, connector block pre-wired including making of electrical connection with & including two core flexible copper conductor cable of suitable size with all accessories , fixed in repair, ccomplete all as specified and as directed. Make: Havells Model City-1 or equivalent in Philips /Crompton.
Replacement of existing LED bulk head light fitting with new LED bulk head light fittings 10 watt, 230 volts AC made up of pressure die cast housing, IP65 protection, 5700K including making of electrical connection with & including two core flexible copper conductor cable of suitable size with all accessories, complete all as specified and as directed. Make: Crompton cat part No. LBHN-10-CDL or equivalent in Philips/Havells.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit inplain cement concrete 1:2:4, type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, and as directed . Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of galvanized iron wire 4mm dia, complete all as specified and directed.
Note :- An amount of Rs. 24,265.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
MS Ghulam Hassan and Sons
M/S BASHIR AHMAD AND SONS
BHAT CONTRACTORS AND GENERAL ORDER SUPPLIERS
FG CONSTRUCTION
M/S ABBAS M. ENTERPRISES
ORISON ENTERPRISES
M/S GEE EMM MIR
GH MOHD SHAH AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .