| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC 778 N LOWER CHELIDANGA ASANSOL PASCHIM BARDHAMAN | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.0 L+₹35,379.77 (3.04%)Rejected-Finance RAJBARI PARA JALPAIGURI | JALPAIGURI | JALPAIGURI | WEST BENGAL | L2 | Rejected-Finance Rejected | |
| 3 | L3₹12.3 L+₹71,324.46 (6.13%)Rejected-Finance 266 1 S B GORAI ROAD BESIDE VIDYASAGAR MAIDAN ASANSOL 713301 | ASANSOL | BURDWAN | WEST BENGAL | 713301 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹12.7 L+₹1.1 L (9.50%)Rejected-Finance R C PANDIT LANE NAMOPARA PURULIA | PURULIA | PURULIA | WEST BENGAL | 723101 | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
27 Dec 2024, 6:00 pmClosed
Executive Engineer, BMD, PHE, Dte
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Servicing and rectification work at 4 panel VCB ,Single Panel VCB, AVR,200 KVA Transformer of 11 KV Sub-station of Parsala water supply scheme under BMD, PHE Dte.
2024_PHED_779084_18
WBPHED/EE/BMD/NIeT-13 OF 2024-2025
Open Tender
MECHANICAL
Item Rate
60 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹26,000
Yes
3 Mar 2025
13 Dec 2024
30 Dec 2024
13 Dec 2024
27 Dec 2024
13 Dec 2024
Amount
(Part-A) 4 PANEL VCB
Attending the fault at PARSALA, Bankura District with carrying different Testing, Servicing kit/machine like Insulating Resistance Checking machine (1 KV, 2.5 KV, 5 KV) 3 Phase Variac, Current Injection machine/ kit, Voltage injection machine/kit, Blower, Multimeter, Clamp meter, Different type of tools tackles, Various Testing Wires, MCBs, Wires & Cables, HT insulation Tapes, Gas can with nozzle, CRC WD-40, Lecta Cleaner, Adhesive non Adhesive PVC Tape and items for complete servicing and testing the Transformers, VCBS, AVR with connecting HT, LT cables.
Charges for 11 KV VCB Racked out from 11 KV Panel, 11 KV VCB Mechanism dismantling, 11 KV VI Housing Rubbing, Cleaning by applying CRC, WD-40, Varnishing by applying Red Insulation Varnish and Heating treatment done for IR Improvement, after IR improving 11 KV VCB Racked IN inside Panel and power charging by Expert Electrical Engineer.
Charges for 11 KV HT Cable disconnection, 11 KV CT Primary & Secondary Side disconnection, 11 KV CT Dismantling, 11 KV CT Testing, 11 KV CT Rubbing, Cleaning by applying CRC, WD-40, Varnishing by applying Red Insulation Varnish and Heating treatment done for IR Improvement, finally Re-fitting the 11 KV CT and reconnection of 11 KV HT Cable by Expert Electrical Engineer.
Charges for 11 KV cable Disconnecting, Cleaning, Heating and HT Sleeves replacing for IR Improvement and Re-fitting of AVR input & output cable and 4 panel VCB outgoing cable.
Charges for 11 KV CT Spouts Dismantling from Panel, Rubbing, Cleaning by applying CRC, WD-40, Varnishing by applying Red Insulation Varnish and Heating treatment done for IR Improvement and finally Re-fitting of OG – 1 & Spare VCB Panel.
Charges for 11 KV Bus-Bar Spouts Dismantling from Panel, Rubbing, Cleaning by applying CRC, WD-40, Varnishing by applying Red Insulation Varnish and Heating treatment done for IR Improvement and finally Re-fitting OG – 1 & Spare VCB Panel.
Charges for all 11 KV 4 panel VCB 3-ph Bus-Bar Dismantling Rubbing, Cleaning, Heating by applying CRC, WD-40, for IR Improvement
Supply and Delivery of following items-
O/C & E/F Relay Make: Schneider, Model: Micom P111 / Easergy P1
200-Watt Space Heater
Thermostat
HT Sleeves supply for 240 sq. mm HT cable
HT Sleeves supply for 95 sq. mm HT cable
Current Transformer Ratio: 15/1+1 A Core1: 15 VA, Class: 0.5 Core2: 15 VA, Class: 5P20 STC: 26.3 kA for 1 SEC
11 KV 3-Phase Potential Transformer Ratio: 11 KV/ 110 V IL : 12/28/75 KV,HSV : 12 KV, Phase : 3. Class : 0.5, Burden : 200 VA VF: 1.2, continuous – 1.5 for 30 Sec.
Charges for old defective items O/C & E/F Relay,Space heater,thermostat, CTs,PTs Secondary wire disconnection and dismantling the defective items from circuit and Fitting,Fixing and Installation of newly supplied above items (by suppling nessecary item such as 2.5 sqmm cable etc.) Bus-Bar connection, CT,PT secondary wire re-connection and after re-fitting all items at circuit or existing position testing & Commisioning as per direction EIC.
Supply paint and Painting charges of Incomer Panel inside & Bus Chamber
(Part-B) 250 KVA HT AVR (7 – 12 KV / 11 KV)
Charges for Oil Filtration (B Unit – 300 Ltrs. + (A+C) Unit – 600 Ltrs.)
Charges for Di-Electric Strength Test (BDV Test)
Supply and Delivery of following items-
New Transformer Oil as per IS-335
Silica Gel
240 sq. mm. X 3 core, 11 KV grade, Indoor type, Heat shrinkable End Termination Kit
Control Transformer 50 VA, 240 V / 110 V
Aux Contractor supply (4 NO – 4 NC) Make: Siemens / ABB, Coil Voltage: 110 V AC
Aux Contractor supply (4 NO – 4 NC) Make: Siemens / ABB, Coil Voltage: 220 V AC
PCB Relay Card supply for AVR
Voltage Controller Potentiometer (1K) supply
1100 VA UPS supply Make: APC, Input: 230 V AC
HT Heat Tube supply
Painting Charges of AVR B-Unit and (A+C) Unit (Including Paint supply)
Inspection and Control Operation Rectification Charges of AVR after dismanting part by part.Reassembling newly supplied above items removing damaged items in porper position (including Charges for 100 Ltrs. Oil Top-Up).Commissioning and testing for certain period as per direction of EIC.
All kinds of Gaskets & Oil Seal supply for HT & LT Bushings, Top Cover, Inspection Cover, Valve etc. of (A+C) Unit of 250 KVA AVR
Charges for gasket changes for (A+C) Unit of 250 KVA AVR by disconnecting of all HT and LT terminals, draining transformer oil, opening of top cover, arresting of any oil leakage by changing of gasket and oil seal respectively various gasket portion like top cover, inspection cover, tap switch, conservator tank, radiators, buchholz, drain valve (as where required) and HT-LT bushing portion
(Part-C) SINGLE PANEL VCB
Supply and Delivery of following items-
Power Pack Make: Shruti Electronics, I/P: 110 / 230 V AC, O/P: 110 V DC
200-Watt Space Heater
Thermostat
Fitting fixing charges of above supplied items Power Pack , 4 Nos. Space Heater along with 2 No. Thermostat connection including wiring charges for each VCB Panel by expert technician as per direction of EIC
(Part-D) 200 KVA Transformer (11 KV / 0.433 KV) :
Carring charges for oil filteration machine with Di- electric machine,BDV testing kit from workshop to work site Rudra IBS of Bankura
Oil Filtration charge (370 Ltrs. X 2 Nos. Transformer)
Charges for Di-Electric Strength Test (BDV Test)
Supply and Delivery of following items-
New Transformer Oil for Transformer-2
Transparent Breather with ¼ Kg. Silica Gel
All kinds of Gaskets & Oil Seals supply for HT & LT Bushings, Top Cover, Inspection Cover, Valve etc. of 200 KVA, 11 KV / 433 V Transformer
Charges for 12 Nos. 16 sq. mm. and 12 Nos. 25 sq. mm. Cable Lug connection,replacement of 16 sq. mm. Cable & 3 phase Terminal etc as per requirment at site
Supply and Delivery of following items cleaning of rusted portion, IR improvement etc-
Red insulation Varnish
HT Tape
Gas Can
Charges for gasket changes for 200 KVA, 11 KV / 433 V Transformer by disconnecting of all HT and LT terminals, draining transformer oil, opening of top cover, arresting of any oil leakage by changing of gasket and oil seal respectively various gasket portion like top cover, inspection cover, tap switch, conservator tank, radiators, buchholz, drain valve (as where required) and HT-LT bushing portion, OLTC Top Cover Gasket Change in each transformer.
Add: 18% GST
Add: 1% Cess
MS S G Enterprise (BID ID -5912200)
M/S. SWAPAN BANERJEE (BID ID -5912287)
Premnath Mitra (BID ID -5912268)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .