| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹13.9 L+₹57,352 (4.30%)Rejected-Finance | L2 | Rejected-Finance Due to higher rate offered | |
| 3 | L3₹14.1 L+₹74,553 (5.59%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L3 | Rejected-Finance Due to higher rate offered | |
| 4 | L4₹14.2 L+₹81,976 (6.14%)Rejected-Finance B 16 280 KALYANI NADIA 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | L4 | Rejected-Finance Due to higher rate offered | |
| 5 | L5₹14.4 L+₹1.1 L (7.93%)Rejected-Finance 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | L5 | Rejected-Finance Due to higher rate offered |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
1 Dec 2018, 3:00 pmClosed
EE CKHED PWDte
EE CKHED PWDte P 12 CIT RD 1ST FLOOR KOL 14
Electrical Installation and Air conditioning work at Orthodontic Dept old building of Dr R Ahmed Dental College n Hospital Air conditioning arrangement
2018_WBPWD_196712_1
WBPWD/EE-I/CKHED/NIT-16/ 18-19
Open Tender
A/C ORG
Item Rate
30 days
Dr R Ahmed Dental College n Hospital
as per NIT
4 documents required · 4 mandatory
₹36,000
EE CKHED PWDte P 12 CIT RD 1ST FLOOR KOL 14
25 Sept 2020
15 Nov 2018
3 Dec 2018
15 Nov 2018
1 Dec 2018
22 Nov 2018
20 Nov 2018
Amount
SITC of Ceiling Suspended Unit
Supply ,Installation ,Testing & Commissioning of Ceiling Suspended Ducted unit with 132000 btu/hr Cooling capacity,4400 CFM Air Flow, with twin scroll compressor,Microprocessor based Controler of 11 TR nominal capacity with R-410A/R407C Refrigerant. (Make:-Hitachi/Voltas/Blue-Star/Carrier)
SITC of Refrigerant Gas Charging R410a/R407C gas per site requirements
SITC of Copper Refrigerant Piping with Suitable Insulation.
SITC of Hard Drawn Copper Pipe with Nitrile Rubber Insulation
7/8 inch Dia Suction Line ,1/2 inch Dia liquid line with insulation.
5/8 inch Dia Suction Line ,1/4 inch Dia liquid line with insulation.
Supply ,Installation and Testing of rigid PVC Drain Piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
40 mm dia
32 mm dia
supply & fixing of control cum transmission wiring of Copper conductor cable for looping between indoor & outdoor VRF system & to main Central remote controller system. Make: Polycab,Finolex,KEI.
7 C X 1.5 Sq. mm
Ducting
SITC of Site Fabricated Duct with 13 mm thick Nitrile Rubber Insulation complete with supports dampers etc. as per specifications & drawings. Make: SAIL,TATA,Jindal.
SITC of Plenum Chamber with 20 Gauge GI Sheet & 48 kg/m³ x 12mm thick Rigid Board with RP tissue and 24G Al. perforated sheet.
Duct Thermal Insulation
Providing and fixing closed cell crossed linked polyethylene insulation on duct complete with all accessory as required. Make:-Supreme,k-Flex.
13 mm thick
Duct Acoustic Lining
SITC of Acoustic Insulation of 48 kg/m³ x 12mm thick Rigid Board with RP tissue and 30G Al. perforated sheet. Make: Twiga/Universal.
Grilles/Diffusers
Supply, Installation and Testing of Circular diffusers as per specifications and drawings. Make:- Premier,Systemair,Dynacraft.
Aluminium supply air Diffuser with VCD
Providing and fixing fire retardant nonporous double layer flexible connection between each unit and duct.
Manual Volume Control Duct Dampers:
Supply, Installation and Testing of 16 G GI Frame / 24 G GI aerofoil blades type Volume Control Duct Dampers complete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete.
Supplying, fabrication & fixing 3Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of 1m. lengthfor making platform for installation of outdoor unit of ductable split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge, for transmitting the load centrally through 2Nos.(50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire platform should be baricaded & safe for ODU maintenance. Area of the platform is 3Mtr. x 1Mtr.
SITC of ODU placement structure with heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration.
Lifting & Shifting of IDU & ODU
Supply & Febrication of Fresh Air Arrangement with rain protective cowl.
Rate should be quoted incl. of all taxes and cess.
IDEAL INCORPORATE SOLUTION
CARRION AIR COOLING
REFRICON
WEATHER MAKERS INDIA
ELECTRIC REFRIGERATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .