Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹62.7 LAdmitted-Finance | -23.00% | ₹62.7 L | L1 | Admitted-Finance |
| 2 | L2₹65.2 LAdmitted-Finance | -19.99% | ₹65.2 L | L2 | Admitted-Finance |
| 3 | L3₹65.3 LAdmitted-Finance | -19.90% | ₹65.3 L | L3 | Admitted-Finance |
| 4 | L4₹65.4 LAdmitted-Finance B CLASS S C CONTRACTOR AT ADHEISUNDI PO TRILOCHARPUR PS KANPUR DIST CUTTACK ODISHA | PURI | ODISHA | 752120 | -19.80% | ₹65.4 L | L4 | Admitted-Finance |
| 5 | L5₹67.6 LAdmitted-Finance AT KENDUBILWA PO PRATAPRUDRAPUR PS BALIANTA | KHORDHA | ODISHA | 751001 | -17.01% | ₹67.6 L | L5 | Admitted-Finance |
Tender Value
₹81.5 L
EMD Value
₹81,493
Closing Date
2 Feb 2026, 5:00 pmClosed
Superintending Engineer BBSR R and B Divn No II
Office of S E BBSR R and B Divn No II Surya nagar Unit-7
Construction of Parking Shed and improvemnet of Store Building at Bhubaneswar R and B Division-II office (Ltr no.41887 dt.03.11.2025) (Building Work)
2026_EICCL_124805_1
eTCN-35/2025-26
Open Tender
Civil Works - Buildings
180 days
Bhubaneswar
2 documents required · 2 mandatory
₹10,000
₹81,493
Yes
13 Feb 2026
20 Jan 2026
3 Feb 2026
20 Jan 2026
2 Feb 2026
20 Jan 2026
CIVIL WORK Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto a lead of 1000metres including removal and disposal of top organic soil not exceeding 150mm in thickness as per Clause 201 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost of all labour, T&P, royalty etc complete and as per direction of Engineer-in-Charge.
Dismantling of Cement Concrete Grade M-15 & M- 20 including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres
Dismantling Brick / Tile work in cement mortar including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres
Dismantling of Prestressed / Reinforced cement concrete grade M-20 & above including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead
Dismantling and removing old tiled flooring including stacking the useful materials for reuse and removing the debris within 50m lead.Per 1 sqm
Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep stacking the useful materials for reuse and removing the debris within 50m lead. Per 1 sqm
Removing old lime or cement plaster from walls including racking out joints 12mm deep and removing the debris within 50m lead. Per 1 sqm
Earth work in excavation of foundation trenches in hard soil including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site within 50m initial lead & 1.5m initial lifts with sundries & T&P required for the work complete including cost of all labour,labour cess,T&P,sundries etc. as directed by the Engineer in charge. (a) Upto 1.5m Depth
(b) Beyond 1.5mtr to 3.00 mtr Depth
Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge.
Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge.
Supplying and filling in foundation and plinth with good quality river sand including watering, ramming with cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge
Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (IMIDACHLOPRIED 30.5SC mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.(make-premise-BAYER,Paxton-FMC,ozie-KALYANI)
Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties of all materials with all labour and T&P required for the work etc. complete in all respect and as per the direction of the Engineer-in-charge.
Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Ground floor
Terrace floor
Half brick work with Fly Ash brick masonry in cement mortar (1:4) in super structure having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. Ground floor
Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. Footing
Plinth Beam
Staircase
R.C.C Column & Roof Beam Ground floor
R.C.C Column & Roof Beam Terrace floor
R.C.C Lintel Ground floor
R.C.C Lintel Terrace floor
R.C.C Roof Slab Ground floor
R.C.C Roof Slab Terrace floor
Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding, wastage & over lapping and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. Ground floor
Terrace floor
Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground floor
Terrace floor
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground floor
Terrace floor
Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. Ground floor
Terrace floor
Providing & laying granite stone flooring using 19 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge. Ground floor
Providing & laying granite stone flooring in Floors and landing using 19 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. Ground floor
Terrace floor
Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) Ground floor
Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 1200x600 (homogeneous) of premium quality (JOHNSON / SOMANY/ KAJARIA/ RAK) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. Ground floor
Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plain (Ivory) of approved make (JOHNSON / SOMANY/ KAJARIA/ RAK) as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects. Ground floor
Supplying, fitting & fixing of well dressed and seasoned sal wood choukath of approved size wrought and put up in door frame including two coat of coaltaring to wall and lintel side faces, in all floors including cost, conveyance, cost of all labour, labour cess, T&P etc. complete as directed by Engineer-In-Charge.
Providing & Fixinng factory made 100% Solid WPC ( Wood Polymer Composite )- Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ),Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, , all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. (Make - Green Land / Century/ Alstone)
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge.
Supplying and installing UPVC- 2 tracks sliding windows and 2 sashes (shutters) with ss mesh sash dimension of 58 mm x 32 mm and sash dimension of 61mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 5mm reflective toughened glass of make - Saint gobain/AIS/Gardian/modi . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge. (Make-FENESTA/ Koemmerling/ Saint Gobain/ Prominance) Ground floor
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. Ground floor
Terrace floor
Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. (Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-Charge) Ground floor
Terrace floor
Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make (JK White/ Birla white or equivalent make duly approved by Engineer-in-Charge) and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. Ground floor
Terrace floor
Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. (Make: Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-charge) Ground floor
Terrace floor
Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. (Make-Asian/ Berger/ Dulux/ Nerolac or equivalent make duly approved by Engineer-in-charge). Ground floor
Terrace floor
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. (Make-JINDAL )
Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. Terrace floor
Waterproofing application:-Providing and installing two component acrylic modified cementitious waterproofing coating with Masterseal 551 /Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect. Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakage Potlife @ 25°C 2 hours & @ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L (MYK/FOSROC/SIKA/SUNANDA/ASIAN PAINT/EQV.) Terrace floor
Supplying and fixing G.C.I sheeet on roof drilling hole in wind ties including fixing of ridges valley wind ties etc excluding cost of fittings per 1 sqm of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.
Loosening to a depth of 150mm, leveling and compacting original ground supporting embankment /sub-grade as per approved drawing and technical specifications as per Section 900 and Clause 305, 305.3.4 of MoRT&H Specification for Road & Bridge works (5th Revision) and as per direction of Engineer-in-Charge.
Construction of granular sub-base by providing Grading-VI Material as per table 400-2, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works.(Latest Revision)
Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 as per direction of the Engineer-in-charge.
Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150mm thick, foundation having 50mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 including cost of all materials, labour, T&P, royalty etc complete in all respect and as per direction of the Engineer-in-charge.
Providing & Painting with synthetic enamel paint of approved brand and manufacture to give an even shade as per the instruction of Engineer-In-Charge at all floors and all heights including all material & labour complete.
E.I. WORK Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. GROUP-A- L.P- 7 F.P - C.B.P
GROUP-B- L.P- 11 F.P - 12 C.B.P
GROUP-C- L.P- 9 F.P - 6 C.B.P
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6Amp switch and socket of Modular type including all connection. (Make- Great white/ Legrand / ABB/ Roma/ Havells/ HPL/ Cona or equivalent).
Supply and fixing of Modular metal box on surface or in recess with suitable size of Modular cover in front including providing and fixing of 6pin 6Amp & 16Amp socket outlet and 16Amp Modular switches including all connection. (Make-Great white/ Legrand / ABB/ Romal Havells/ HPL/ Cona or equivalent).
Supply and fixing of Electronics step type Modular fan regulator. (Make- Great white/ Legrand / ABB/ Roma/ Havells/ HPL Cona or equivalent).
S/F of Multipurpose board consisting 2nos. 6Amp plug and switch with all connections. (Modular type) (Make-Great white/ Legrand / ABB/ Roma/ Havells! HPL/ Cona or equivalent).
Recessed wiring to submain in the following sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS- 694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as required. (Make of wire- Finolex/ L&T/ Anchor/ Havells/ V-Guard/ HPL or equivalent). 2 X 2.5 sq.mm +1 X 1.5 sq.mm
2 X 4 sq.mm +1 X 1.5 sq.mm -do-
2 X 6 sq.mm +1 X 2.5 sq.mm in 25mm dia
S/F of Bakelite angle holder/batten holder of ISI marked conforming to IS- 1258/1987 in place of ceiling rose.
Supply and fixing of Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required as per the direction of Engineer-in-charge.
Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (Make-HPL/ Havells/ Legrand/L&T/ C&S or equivalent). 8way, single door
Supply and fixing of 0.5Amp to 32A rating 240 V "C" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make- HPL Havells/ Legrand / L&T/ ABB or equivalent). 6Amp rating to 32Amp (SP)MCB
Supply and Fixing of 24watt recess LED Square (1' x 1') light fitting. (Make- Havells/ Phillips/ Bajaj Crompton or equivalent). as per the direction of Engineer-in-charge.
Supply and Fixing of 70/ 72 watt LED street light fitting. (Make- Havells/ Phillips/ Bajaj/ Crompton or equivalent), as per the direction of Engineer- in-charge.
Supply and Fixing of 18/ 20 watt LED Tube light fitting. (Make-Havells/ 30 Phillips/ Bajaj/ Crompton or equivalent). as per the direction of Engineer- in-charge.
Supply and fixing of following fan. A.C Ceiling fan 36" size. (Make-Polycab -Vital / Crompton -Jural Havells- 12 Velocity or equivalent). as per the direction of Engineer-in-charge.
Indusrtial Exhaust fan 18" size (Heavy Duty) with making hole of required size. (Make-Havells/ Usha/ Almonard/ Orient/ Crompton or equivalent). as per the direction of Engineer-in-charge.
Supply of 32mm HDPE Pipe
Supply of PVC armored cables ISI marked. (Make- Glowstar/ Polycab/ Nicco/KEas per letter No.309 19.01.2011 of SEEC (R&B) Odisha 16sqmm 4core
Trenching with sand spreading and bricks laying and laying of cable in 140 trench in 2 1/2' depth pvc cable upto 25sqmm
Supply and Fixing of extra down rod 20mm dia for 20cm x 5
Supply and fixing of 40mm dia GI Street light bracket. (1mtr long)
Supply, Installation, Testing Charging of 40Amp MCCB Panel board having provision of Incomer- 40Amp MCCB -1 No, Outgoing:- 63Amp Cupper Bus bar, Indicator, 32Amp DP MCB-8Nos, Volt meter, Amp meter
SIF of multipurpose board Modular 6A 3nos. Switch and 3nos. Socket and 1no. Switch and socket 15A on Modular board and cover. (Make-Great whitel Legrand / ABB/ Roma/ Havells/ HPL Cona or equivalent).
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_2.pdf
PDF • 0.74 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_576701.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid