Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC 43 228 5 OM VILLA GOPAL NAGAR CHIRAHULA HUZUR REWA REWA M P | REWA | REWA | MADHYA PRADESH | ₹21.5 L Quoted ₹22.3 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹27.6 LRejected-Finance SHOP NO 48 KHARAR ALIPUR ALIPUR HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | ₹27.6 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹28.0 LRejected-Finance 1849 JUGRAJPUR SACHENDI KANPUR KANPUR NAGAR UTTAR PRADESH 208023 UDYAM UP 43 0012110 | KANPUR NAGAR | UTTAR PRADESH | 208023 | ₹28.0 L | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | OM CONSTRUCTION CO. L1 | Balaji Construction Co. L3 | M/S SM BUILDER CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Receiving, recording, registering and lodging complaint(s) of any nature through computer in excel as per the format given by the Engineer-in-Charge and bifurcating the complaint(s) and preparing docket(s) as per the nature of complaint(s) e.g. Civil Works and Carpentry Works and as per the building Nos and assigning the complaint(s) to their workmen for rectification. Attending the complaint(s) entered into the docket pertaining to Civil Works (incl carpentary, plumbing, masonary, sanitary, sewage, welding etc) rectifying the defects and resolving the complaint(s) complete all as specified and as directed.
Note : (a) All the complaint(s) entered into the same docket shall be treated as one unit of complaints and shall be measured for payment.
(b) The complaint(s) shall be received from Resident/RWA/JE/Engineer-in-Charge personally, telephonically, online, ARMAAN etc.)
(c) One complaint entered in one docket required multiple visit to same location for rectification of the same complaint will be treated as one docket.
Contd/-.................................... | 6,500 | EACH Complaint | 15 ₹97,500 | 30 ₹1.9 L | 50 ₹3.3 L |
| 1.10(d) The complaint(s) rectified shall be measured under the respective or relevant items of schedule “A” if the respective and relevant items are matching with the requirement of complaint(s) to the extent of 85% to 115%. The remaining complaint(s) with the docket shall be treated as one unit and shall be paid if it shall be more than zero. (e) The complaint(s) to be rectified shall include transportation, conveyance, labour, tools and plants including the cost of minor materials and the quoted rate shall be inclusive of all these factors. (f) The complaint(s) entered into the same docket i.e. one unit of complaint(s) shall be treated as resolved if all the complaint(s) pertaining to the dockets have been resolved. (g) The manpower shall be deployed by the contractor as per the requirements. The requirement of manpower shall be updated and estimated by the contractors fortnightly as per the complaints to have been received and it shall be used as tentative guidelines for further period. Contd/-.......................... | ||||||
| 1.20(h) The contractor shall receive and record complaint(s) from 0900 hours to 1700 hours on each day at MES service centre. The docket shall be prepared within one hour from the receipt of the complaint(s) and shall be assigned to their workmen within two hours from the receipt of the complaint(s). (i) The complaint(s) shall be attended and resolved within 24 hours from the receipt of the complaints and the docket duly signed by the occupants regarding resolution of complaint(s) shall be submitted. (j) If the complaint(s) have not been resolved within 24 hours from the receipt of the complaints, failing which penalty @ Rs. 100/day/complaint shall be levied upon the Contractor and deducted from the payment due. (k) Format of docket slip and complaint register which shall be kept in complaint cell. (l) Stationery i.e. log sheets, docket slips, job cards, complaint registers, handing taking registers, store issue register, etc. shall be provided by the contractor without any extra cost to the department and cost there of shall be deemed to be included in quoted rates by the contractor against respective items of schedule “A”. Contd/-.................. | ||||||
| 1.30(m) The minor materials shall (mean nails, screws, nuts, bolts, washers, flexible wires, tapes, thimbles, Teflon tape, clothes, rawl plugs, hinge, cement upto 1 Kg for each unit of complaints including required quantities of sand/stone dust, white cement upto 0.25 Kg for each unit of complaints, putty, welding rods, painting works, spindle etc.) be provided by Contractor, if required, without any extra cost. (n) The contractor shall have minimum stocks of materials to meet the requirement of one month. The minimum stock of the materials of the first month shall be estimated and calculated as per the quantities of the contract and as per the completion period. The minimum stocks of the materials shall be recalculated, estimated, updated fortnightly on the basis of the consumption of the previous fortnight and the calculation details shall be submitted to the Engineer-in-Charge for approval. However, the completion period to resolve any complaint shall have no connection with the minimum stocks and the contractor shall arrange the materials to resolve the complaint(s) within the prescribed period. (o) Material, to be replaced wherever required, will be of same brand & model or as directed by Enigneer-in-charge | ||||||
| 2.00 | S&F in repair golden brass tap spindle of suitable size 4 no for CP bib tap/angle cock/pillar tap of any type complete all as specified and directed by Engr-in-Charge. | 600 | Each | 45 ₹27,000 | 50 ₹30,000 | 60 ₹36,000 |
| 3.00 | S&F in repair long golden brass spindle of suitable size for concealed stop cock, mixer of any type complete all as specified and directed by Engr-in-Charge. | 60 | Each | 35 ₹2,100 | 60 ₹3,600 | 60 ₹3,600 |
| 4.00 | S&F in repair 15 mm bib tap ( fancy type) , cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge. | 60 | Each | 300 ₹18,000 | 300 ₹18,000 | 500 ₹30,000 |
| 5.00 | S&F in repair CP angle valves (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed by Engr-in-Charge. | 70 | Each | 300 ₹21,000 | 280 ₹19,600 | 300 ₹21,000 |
| 6.00 | S&F in repair chromimum plated 15mm bore pillar taps with capstan head (but fancy type) screwed down high pressure with or without lettered Hot or cold with long screwed shank and fly nuts screwed for iron pipe and fixed all as specified. | 15 | Each | 280 ₹4,200 | 300 ₹4,500 | 550 ₹8,250 |
| 7.00 | S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required complete all as specified and directed by Engr-in-Charge. | 15 | Each | 450 ₹6,750 | 500 ₹7,500 | 700 ₹10,500 |
Updated dates
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
25 Dec 2025, 6:00 pmClosed
GE Hisar
GE Hisar
DAY TO DAY MAINT OF MD ACCN AT DSTV SOUTH IN THE AOR OF AGE B/R-I UNDER GE HISAR AT HISAR MIL STN
2025_MES_741389_1
GE(H)-57/2025-26
Open Tender
Civil Works
330 days
GE Hisar
As per NIT
6 documents required · 6 mandatory
₹500
GE Hisar
₹64,000
Yes
19 Mar 2026
25 Nov 2025
1 Jan 2026
25 Nov 2025
25 Dec 2025
10 Dec 2025
Amount
Receiving, recording, registering and lodging complaint(s) of any nature through computer in excel as per the format given by the Engineer-in-Charge and bifurcating the complaint(s) and preparing docket(s) as per the nature of complaint(s) e.g. Civil Works and Carpentry Works and as per the building Nos and assigning the complaint(s) to their workmen for rectification. Attending the complaint(s) entered into the docket pertaining to Civil Works (incl carpentary, plumbing, masonary, sanitary, sewage, welding etc) rectifying the defects and resolving the complaint(s) complete all as specified and as directed. Note : (a) All the complaint(s) entered into the same docket shall be treated as one unit of complaints and shall be measured for payment. (b) The complaint(s) shall be received from Resident/RWA/JE/Engineer-in-Charge personally, telephonically, online, ARMAAN etc.) (c) One complaint entered in one docket required multiple visit to same location for rectification of the same complaint will be treated as one docket. Contd/-....................................
(m) The minor materials shall (mean nails, screws, nuts, bolts, washers, flexible wires, tapes, thimbles, Teflon tape, clothes, rawl plugs, hinge, cement upto 1 Kg for each unit of complaints including required quantities of sand/stone dust, white cement upto 0.25 Kg for each unit of complaints, putty, welding rods, painting works, spindle etc.) be provided by Contractor, if required, without any extra cost. (n) The contractor shall have minimum stocks of materials to meet the requirement of one month. The minimum stock of the materials of the first month shall be estimated and calculated as per the quantities of the contract and as per the completion period. The minimum stocks of the materials shall be recalculated, estimated, updated fortnightly on the basis of the consumption of the previous fortnight and the calculation details shall be submitted to the Engineer-in-Charge for approval. However, the completion period to resolve any complaint shall have no connection with the minimum stocks and the contractor shall arrange the materials to resolve the complaint(s) within the prescribed period. (o) Material, to be replaced wherever required, will be of same brand & model or as directed by Enigneer-in-charge
S&F in repair golden brass tap spindle of suitable size 4 no for CP bib tap/angle cock/pillar tap of any type complete all as specified and directed by Engr-in-Charge.
S&F in repair long golden brass spindle of suitable size for concealed stop cock, mixer of any type complete all as specified and directed by Engr-in-Charge.
S&F in repair 15 mm bib tap ( fancy type) , cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in repair CP angle valves (chromium plated fancy type) 15 mm dia, cast copper alloy, screwed down, high pressure with crutch or butterfly handles, screwed both end for iron pipe or for unions complete all as specified and directed by Engr-in-Charge.
S&F in repair chromimum plated 15mm bore pillar taps with capstan head (but fancy type) screwed down high pressure with or without lettered Hot or cold with long screwed shank and fly nuts screwed for iron pipe and fixed all as specified.
S&F in repair 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as required complete all as specified and directed by Engr-in-Charge.
S&F in repair complete set of flush kit as required shape & size of 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white complete all as specified and directed by Engr-in-Charge.
S&F in repair handle for flushing cistern with sutaible size for cistern of 10 Ltr capacity low level white complete all as specified and directed by Engr-in-Charge.
S&F in repair 15 mm dia PVC connections, 600 mm long with PTMT nuts of suitable size at two end complete all as specified and directed by Engr-in-Charge.
S&F in repair 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed by Engr-in-Charge.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white with P or S trap with and including plastic water closet seat cover , connection to trap, flushing pipe & anti -syphonage pipe etc including necessary materials for fittings & making good to floor complete all as specified and directed by Engr-in-Charge.
S&F in repair vitreous China, squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PTMT trap of suitable size ( P or S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of lime concrete bedding & making good to floor complete complete all as specified and directed including taking out old one.
S&F in repair Vitrous china wash hand basin, white, flat back of size 550 x 400 mm white excluding taps, and plug and porcelain stopper but including bracket, cutting for and pinning the ends of brackets, PTMT waste coupling & waste pipe as suitable complete all as specified and directed by the Engr-in-Charge.
S&F in repair PVC flexible waste pipe 32mm dia & 90cm long including adopter complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC flexible waste pipe 40mm dia & 90cm long including adopter complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC flush bend 32mm dia for low level flushing cistern to connect flush cistern to WC any type complete all as specified and directed by Engr-in-Charge.
S&F in repair CP Central Hole Basin Mixer with ‘U’ shape Round Casted Spout with 450 mm Long Braided Hoses complete all as specified and directed by Engr-in-Charge.
S&F in repairs, seat cover for EWC with flat bottom and cover and mild steel chromium plated or aluminised hinging complete all as specified and as directed by Engr-in-Chrge.
S&F in Repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repairs 15mm bore dia ball valves high pressure of PTMT with epoxy coated Aluminium rod length 30cm & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer-in-Charge.
S&F in Repair butterfly jet spray mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long including making connections and fixed in position complete in all respect as specified.
S&F in repair 15mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms).
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-Charge.
Supply&Laying of CPVC pipe, SDR 11 ,16mm outer dia & fittings on walls/ceiling or laying in floors complete all as specified.including taking down old pipe
S&F 15 mm dia steel water GI tube medium grade with all fittings and fixed with concealed to walls, ceilings or laid in floors including taking up or down old one complete all as specified and directed by Engr-in-Charge. Make
S&F in repair 20 mm dia steel water GI tube medium grade with all fittings and fixed with concealed to walls, ceilings or laid in floors including taking up or down old one complete all as specified and directed by Engr-in-Charge. complete all as specified and directed by Engr-in-Charge.
S&F Brass Elbow for special fitting of 16 mm bore CPVC pipe complete all as specified and directed.
S&F Brass Tee for special fitting of 16 mm bore CPVC pipe complete all as specified and directed.
S&F Male Brass Threaded Adaptor(MTA/ MBTA) for special fitting of 16 mm bore CPVC pipe complete all as specified and directed.
S&F Female Brass Threaded Adaptor(FTA/ FBTA) for special fitting of 16 mm bore CPVC pipe complete all as specified and directed.
S&F UNION for special fitting of 16 mm bore CPVC pipe complete all as specified and directed.
Dismantling water tank of capacity exceeding 250 liters but not excedding 500 Ltrs complete all as specified and directed by Engr-in-Charge.
Dismantling water tank of capacity exceeding 500 liters but not excedding 1000 Ltrs complete all as specified and directed by Engr-in-Charge.
S&F 500 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I. complete all as specified and directed by Engr -in-Charge.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I. complete all as specified and directed by Engr -in-Charge.
S&F 20mm bore dia ball valves high pressure of PTMT with epoxy coated Aluminium rod length 30cm & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) including suitable socket as required complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 20mm bore dia ball valves high pressure of PTMT with epoxy coated Aluminium rod length 30cm & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of (ANTI LIFT MONKEY PROOF) removable metallic lid cover of PVC OH tank with fixing arrangement imcl threaded GI nut and bolt and other fixing arrangements required complete all as specified and directed.
S&F GI tank Nipple suitable for HDPE water tank 20mm bore (Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms) complete all as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from tanks by mechanical means from mouths of circulating pipes, etc. of tanks exc 250 and n. exc 500 Ltr incl disconnecting, reconnecting and refixing if necessary and treating tanks with UV radiations complete all as specified and as directed.
Repair/replacement to joints of GI / composite water tubing (15-25mm dia) by replacing existing joints / use of reducer / provision of new GI fittings with and including re-positioning the water tubing on required basis at site during execution of works as per suitable method / directed by Engr-in-Charge . Note : Following itmes may be requried for replacement of joints namely Tank nipples, reducers, tees, elbows, nipples, unions, sockets, CP brass nozzle male/female etc. Provision of new water tubing required at any place during re-positioning the water tubing / carry out repair works will be measured in respective itmes and paid seprately in relevent plumbing items.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
S&F in repairs, butt hinges, medium weight, cold rolled, mild steel of size 125mm long including taking down shutters and re-fixing the same in position with door frame with and including necessary cutting & welding to existing steel door frame and necessary carpentry works for proper functioning of wooden shutters complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair acrylic transparent sheets 3mm thick in square / rectangular area of each pane not exc 0.5 sqm and fixed /lock with window frame by using PVC snap beeding with necessary self tapping reviting / screwing and suitable method with and complete all as specified and directed.
Supply and fixing in repair acrylic frosted/figured sheets 3mm thick in square / rectangular area of each pane not exc 0.5 sqm and fixed /lock with window frame by using PVC snap beeding with necessary self tapping reviting / screwing and suitable method with and including and complete all as specified and directed.
S&F in repair 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F in repair 200mm size aluminium anodised, barrel tower bolt of extruded section complete all as specified and directed.
S&F in repair extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed.
S&F in repairs mild steel 300mm, ordinary rat rail rod pattern springs, including roller and roller plate complete all as specified and directed.
S&Fin repair 100mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door complete all as specified and directed.
S&F in repairs, 75mm long Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-Charge.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each and complete all as specified and directed.
S&F for 1mm thick factory made pressed steel shutter fixed with 1.25mm thick pressed steel frame of 105 x 60mm and as reqd for cupboards (consisting two shutters) including 06 Nos hinges of size 75mm long and Godrej pattern three way locking system with suitable shape & size 12mm dia MS rod & 01 Nos chromium plated handle of size 150mm long with & including two coats of shop spray synthetic enamel painting over a coat of red oxide primer as colour approved by GE. Note 1: Cupboards frame to be fixed with 06 Nos nuts & bolts of dia 12mm & 150mm long at vertical outer edge of cupboards brick wall / concrete surface including making good the distrubed surfaces complete all as specified and directed. 2 Front Face shall only be measured for payment purpose.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed by Engr-in-Charge.
Providing 18mm thick factory made 100% solid rigid PVC ( Poly Vinyl Chloride ) foam sheet prelam colour having density of 600 Kg/cbm Manufactured by an ISO 9001-2015 Certgied Company. for kitchen cabinet/ Cupboard self, Termite proof, water proof and flame retardant PVC sheet, manufactured by single layer extrusion process, for one side laminated solid PVC foam sheet PVC film laminate should be pasted on PVC sheet with suitable continuous hinge, 100mm long decorative ss handle, magnet for receiving door shutter, adhesive,hasp staple and of approved shade, manufacture embossing, barcode and hologram on door, test certificates and authorization letter complete all as specification approved by engineer-in-charge
S&F in repair brass chromium plated shower roses of size 125mm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engr-in-Charge.
S&F in repair CP grating dome without waste pipe hole 100 mm dia (minimum weight 25 gms) complete all as specified and directed by Engr-in-Charge.
S&F in repair CP grating dome with waste pipe hole 100 mm dia (minimum weight 25 gms) complete all as specified and directed by Engr-in-Charge.
S&F in repair Aluminium anodised Brackets for curtain rails complete all as specified and as directed.
S&F in repair 20mm dia a CP curtain rod fancy type, with fixing fancy type CP brackets (02 Nos for each opeing), fancy type side stoppers (02 Nos for each opening) complete all as specified and directed.
S&F in repair towel rail 600 mm long of chromium plated fixed incl screws complete all as specified and directed by Engr-in-Charge.
S&F in repair CP sink Waste Coupling 100 mm including reducer to fixing waste pipe complete all as specified and directed by Engr-in-Charge.
S&F in repair 15 mm CP bib tap long body with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in-Charge.
S&F in repair CP Waste Coupling Full Thread, 32/40 mm complete all as specified and directed by Engr-in-Charge.
S&F 40mm dia, brass polished cupboard knobs fixed with nut, screw and washer of mild steel, bright finished
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 25mm thick (1:2:4) Type-B-0 (using 12.5mm graded crushed stone aggregate) as in levelling course of floors and roofs complete all as specified and directed by Engr-in-Chargre.
M&L non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) compete all as specified and directed.
M&L non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) compete all as specified and directed.
M&L non skid ceramic tiles coloured pattern as required of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in flooring etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in CM (1:4) compete all as specified and directed.
M&L glazed ceramic coloured, designer & pattern (dark & light shade combination) tiles in 450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:3 and d complete all as specified and directed.
M&L for Cutting or uprooting grass on old mud phuska, removing rubbish off the premises, cleaning surface and preparing to receive new mud plaster complete all as specified and as directed.
M&L for preparation of roof surfaces (old or new) with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particles complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (12.5mm) as in levelling course to match the undulations of roof and in covering coping and kerb portion etc complete all as specified and directed.
M&L 10 mm thick cement screed in CM 1:3 mixed with water proofing compound of approved make over RCC roof slab/brick tiles and vertical surface, finished even and smooth by using steel trowel complete all as specified and directed. (WPC shall paid seperatly)
Supply and apply acrylic based waterproofing and heal reflecting system having following key performance properties: 1. Acrylic polymer dispersion single component liquid applied system. 2. Fully reinforced with glass fiber reinforced sika Fab or Equivalent The installation company of roofing system should be trained and authorized by Manufacturer & installation to be carried out as per manufactures approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacture as a part of system. Any component used which is not manufacturer by the roofing manufacturer can only be used with official approval from manufacturer. Application system :- (a) Providing and Applying Primer Coat primer over the prepared surface with Sika® CoolCoat Primer or Equivalent Consumption @0.2-0.3 kg/m² (b) First coat: sika coolcoat or or Equivalent / Consumption @ 0.75 kg/m² (c) Fiber Reinforcement Make Sika or Equivalent (d)Second coat: sika coolcoat or Equivalent / Consumption @ 0.75 kg/m² (e) Top Coat Sika® CoolCoat Primer or Equivalent Consumption @0.05-0.08 kg/m²
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for Brick work with Fly Ash Bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete and all as specified and directed.
M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement / manufacturer's instructions on brick/concrete wall surfaces of any description, and finishing the surfaces even and fair complete all as specified and directed.
Supply only liquid water proofing compound.
M&L preparing new plastered or unplastered surface of walls and applying two coats of cement based paint over a coat of primer complete all as specified and directed by Engineer-in-charge. Note: The work is required to be carried out G+2 storey HT Bldg. The rate quoted by the bidder are deemed to be included upto the entire Ht and nothing extra is admissible in this account.
Taking down cement plaster of any description upto three storeys including necessary scaffoldings including raking out joints, hacking for key, scrubbing down with water etc. from wall & ceiling surfaces complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:6 on fair face of brick /concrete surfaces of any description and finishing the surfaces even and smooth without using extra cement complete with complete all as specified and directed.
M&L for rendering 5mm thick in CM 1:3 as in ceiling/landing etc on concrete surface finish even and smooth without using extra cement complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar (monotop) as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed .
M&L for preparing new plastered or unplastered surfaces of walls and applying three coats of white wash on undecorated surface complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer and 2mm average putty of same make complete all as specified and directed.
M&L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash on undecorated surface complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer of same make with and including complete removal of existing treatment of any layer of wall by sanding with internal dust extraction system for clean environment and complete all as specified and directed.
M&L preparing old plastered or unplastered surfaces of walls and applying two coats of white wash on old decorated surface with and including complete removal of existing treatment of any layer of wall complete all as specified and directed.
M&L for preparing old plastered or unplastered surfaces of ceiling and applying two coats of white wash on old decorated surface with and including complete removal of existing treatment of any layer of ceiling surfaces complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.
S&F 110 mm PVC (SWR) access door bends any radius complete all as specified and directed.
S&F 75 mm PVC (SWR) access door bends any radius complete all as specified and directed.
S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.
S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed.
Taking down and refixing after repairing cast iron pipe 100mm bore fixed to walls with necessary fittings/ connection/ heads/ shoes/ bends/ swan neck etc & MS clamps/ clip and necessary screwing as required in new or old position complete all as specified and directed.
Taking down and refixing after repairing cast iron pipe 75mm bore fixed to walls with necessary fittings/ connection/ heads/ shoes/ bends/ swan neck etc & MS clamps/ clip and necessary screwing as required in new or old position complete all as specified and directed.
Demolition of cement concrete in ground floors and paving not exc 15cm thick (below or above ground level) un-reinforced.
M&L for 75mm thick (1:3:6) Type-C-2 (using 40mm graded crushed stone aggregate) as in plinth protection complete all as specified and directed.
M&L for Kota stone slab 15mm thick in riser of bricks steps & riser of staircase , skirting, dado and pillar laid over cement screed and jointed with pigment to match the shade of the slab including rubbing and polishing with & including backing coat in 10mm thick CM (1:3) to receive Kota Stone complete all as specified and directed (Note : Single piece tiles will be placed on the surface of stair case riser area).
M&L for treatment of sunken floor slab comprising of the following specifications with and including demolition of sunken floors complete all as specified and directed:- (i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seppage and where dampness / seppage is noticed, nozzles shall be fixed and grouting carried out. (iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc / Thremax as approved by GE. Contd/-.....................
(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or or equivalent make in Fosroc / Thremax as approved by GE in two coats @ 3kg/sqm to sanwiched with glass fibre reinforcemnt: Sika Fab-1 or or equivalent make in Fosroc / Thremax as approved by GE over base coat as per mnaufacturer's instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer expand still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound SIKA plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed as per manufacturer's specification including rounding of corners and injuctions sloping towards spout. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint . (viii) The sunken floor shall be filled with lean concrete 1:7:12. Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all M&L is inclued in the rates quoted above. Contd/-.....................
Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all M&L is inclued in the rates quoted above.
M/S SM BUILDER CO (BID ID -3507703)
Balaji Construction Co. (BID ID -3501953)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TenderDocumentsGE57.pdf
Tender Documents • 1.69 MB
BOQ_830176.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid