Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.3 L+₹2.5 L (6.70%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹41.2 L+₹3.4 L (8.95%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹41.2 L+₹3.4 L (9.12%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹41.5 L+₹3.7 L (9.92%)Rejected-AOC | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | KOGANTI CONSTRUCTION COMPANY L5 | NEWS CONSTRUCTIONS L4 | M/S P.SWAROOP KUMAR L2 | M/S AMRIT DAS MAHAPATRA L7 | RAJU AND COMPANY L6 | K P R ENTERPRISES L3 | VACON INFRASTRUCTURES L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES :- In case description of any two or more items of the schedule ‘A’ is same and the tenderer quotes different rates for such items, only lowest rate of such items will be considered for acceptance and subsequently payment will be made upon execution of the items accordingly. | ||||||||||
| 1.01 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified. | 25.04 | Cum | 450 ₹11,268 | 350 ₹8,764 | 500 ₹12,520 | 630 ₹15,775.2 | 700 ₹17,528 | 350 ₹8,764 | 150 ₹3,756 Lowest |
| 2.00 | M & L 25 mm thick PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) in sub base of floorings complete all as specified. | 405 | Sqm | 85 ₹34,425 | 75 ₹30,375 | 120 ₹48,600 | 150 ₹60,750 | 120 ₹48,600 | 90 ₹36,450 | 50 ₹20,250 Lowest |
| 3.00 | S&F Non - skid joint free Ceramic colour tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and directed. | 405 | Sqm | 900 ₹3,64,500 | 1,075 ₹4,35,375 | 700 ₹2,83,500 Lowest | 810 ₹3,28,050 | 930 ₹3,76,650 | 1,100 ₹4,45,500 | 1,000 ₹4,05,000 |
| 4.00 | All as per item No. 3 above but in skirting/dado in CM 1:3 , 10mm thick. | 30 | Sqm | 1,300 ₹39,000 | 1,125 ₹33,750 | 750 ₹22,500 | 730 ₹21,900 Lowest | 950 ₹28,500 | 1,150 ₹34,500 | 900 ₹27,000 |
| 5.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. | 160 | Sqm | 32 ₹5,120 | 35 ₹5,600 | 60 ₹9,600 | 100 ₹16,000 | 25 ₹4,000 | 22 ₹3,520 | 20 ₹3,200 Lowest |
| 6.00 | S&F Non Skid joint free colored ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified and as directed complete all as specified and as directed.
Note: Shade and design/pattern of tiles shall be as approved by GE. | 35 | Sqm | 1,150 ₹40,250 | 950 ₹33,250 | 700 ₹24,500 Lowest | 810 ₹28,350 | 860 ₹30,100 | 1,050 ₹36,750 | 800 ₹28,000 |
| 7.00 | M&L, joint free coloured glazed ceramic tiles of size 300 x 450mm, 6 to 7mm thick in dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed. | 115 | Sqm | 825 ₹94,875 | 1,050 ₹1,20,750 | 800 ₹92,000 | 755 ₹86,825 Lowest | 820 ₹94,300 | 1,150 ₹1,32,250 | 900 ₹1,03,500 |
| 8.00 | M&L, 18 to 20mm thick, approved machine cut, coloured Granite, factory polished, edges rounded in steps, cooking platform and the like laid over and including screed bed or bedding layer 20mm thick in cement mortar 1:4, pointing with white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone complete all as specified and directed. | 45 | Sqm | 2,900 ₹1,30,500 | 3,075 ₹1,38,375 | 4,000 ₹1,80,000 | 3,150 ₹1,41,750 | 2,600 ₹1,17,000 Lowest | 3,700 ₹1,66,500 | 2,800 ₹1,26,000 |
| 9.00 | S&F Anodised aluminium snap grid frame work size 605 x 605mm for false ceiling and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified | 20 | Sqm | 450 ₹9,000 | 550 ₹11,000 | 350 ₹7,000 | 5,000 ₹1,00,000 | 420 ₹8,400 | 650 ₹13,000 | 300 ₹6,000 Lowest |
Tender Value
₹46.6 L
EMD Value
₹93,200
Closing Date
20 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Hakimpet
Secunderabad
ADDN/ALTN TO AIRMEN BILLETS (PHASE-II) AND PROVN OF MISC WORKS SERVICES AT FIRE SECTION AT AF STN BEGUMPET UNDER GE (AF) HAKIMPET
2025_MES_722080_1
8809/E8
Open Tender
Civil Works
Item Rate
180 days
Begumpet
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Hakimpet
₹93,200
Yes
14 Oct 2025
23 Jul 2025
22 Aug 2025
23 Jul 2025
20 Aug 2025
6 Aug 2025
Amount
NOTES :- In case description of any two or more items of the schedule ‘A’ is same and the tenderer quotes different rates for such items, only lowest rate of such items will be considered for acceptance and subsequently payment will be made upon execution of the items accordingly.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified.
M & L 25 mm thick PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) in sub base of floorings complete all as specified.
S&F Non - skid joint free Ceramic colour tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
All as per item No. 3 above but in skirting/dado in CM 1:3 , 10mm thick.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
S&F Non Skid joint free colored ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in CM 1:4 complete all as specified and as directed complete all as specified and as directed. Note: Shade and design/pattern of tiles shall be as approved by GE.
M&L, joint free coloured glazed ceramic tiles of size 300 x 450mm, 6 to 7mm thick in dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick backing coat in CM 1:3 complete all as specified and as directed.
M&L, 18 to 20mm thick, approved machine cut, coloured Granite, factory polished, edges rounded in steps, cooking platform and the like laid over and including screed bed or bedding layer 20mm thick in cement mortar 1:4, pointing with white cement (1:2) using marble dust with admixture of pigment to match the shade of granite stone complete all as specified and directed.
S&F Anodised aluminium snap grid frame work size 605 x 605mm for false ceiling and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for Non asbestos fibre cement building boards 6 mm thickness fixed or laid/inserted to timber/GI/Aluminium frame work with screws complete all as specified and directed.
M & L for 25mm dia Stainless Steel Curtain Rod fancy type complete all as specified and directed
M & L for Brackets, Ends Cap and Holder suitable for 25mm dia Stainless Steel Curtain Rod fancy type complete all as specified.
Taking down cement or cement lime plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as apecified
M & L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth complete all as specified and directed.
M&L for Preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each (Without taking off shutters from the frames)
Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 4.8mm thick sheet glass ordinary quality fixing with putty/beading in square in each pane complete all as specified and directed..
M&L for Cement concrete (1:2:4) type B-2 in foundations, filling and mass concrete complete all as directed.
M&F for mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes Fe 410-W (Gde-E-250 quality-A) conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
S&F Rolled sections as in main and cross beams, hip and jack rafters purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates (Fe 410-W Gde-E-250 quality-A) complete all as specified and directed.
M&L Plate (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but not exc 10cm long complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
S&F Mild steel angle/flat iron/chanel framed work such as iron gate, ladder, grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified.
M&L for Preparation of New previously untreated steel surfaces of any description and priming with Red oxide, zinc chrome and applying two coats of synthetic enamel paint over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for Cement concrete type B-1, 1:2:4 (20mm graded aggregate) of 50 mm thick as in floor finishes, finishing the surface even and fair complete all as specified and as directed.
Taking down shutter of any description exc 1 sqm but n exc 2 sqm each complete
S & F, 35mm thick, 2nd class hardwood glazed & skelton shutters, open rebated & prepared to receive glass, gauge, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I section 8 clause 8.20 (a) complete all as specified and directed.
S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
S&F, 100mm size medium wt cold rolled mild steel butt hinges, medium weight complete all as specified and as directed.
S&F, 200mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
S&F, 300mm long aluminium anodized sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F, 150mm size, extruded aluminium anodized handles, fabricated type, complete all as specified and as directed.
M&L for complete removal of existing treatment on wall (Upto plaster surface) and preparing the surfaces and applying two coats of oil bound distemper over a coat of Alkali resistant Primer on 3 mm thick wall care putty, complete all as specified and directed.
M&L for washing, rubbing down and stopping of distempered and painted surfaces of ceiling and applying one coat of distemper oil emulsion, complete all as specified and directed.
M&L for preparation of existing old painted surfaces of walls and applying one coat of cement based paint, complete all as specified and directed.
Demolition of cement concrete in roofs, floors (other than ground floors), etc. (unreinforced) including old tarfelt & cement mortor bedding and plastering etc complete all as specified and as directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M & L cement concrete 1:2:4 Type B1 (using 20 mm graded stone aggregate) as in roof kerbs, bands etc complete all as specified and directed.
M & L 25 mm thick plain cement concrete (1:2:4) type B0 using 12.5mm graded agg as in levelling/padding course on roof slab for water proofing treatment complete all as specified and directed.
M & L rendering 10mm thick on concrete surface in CM 1:4 and finishing even and smooth without using extra cement with using WPC @ 3% by wt. of cement, complete all as specified and as directed (Note:- WPC will be measured and paid separately)
Supply only water proofing compound
M&L for water proofing treatment on existing cleaned RCC roof comprising with the following operation as specified here-in-below:- a) Applying evenly one coat of cold bituminous primer conforming to IS-3384-1986, @ 0.30 litre per square metre on the Cleaned Plastered Surfaces. b) Applying evenly one Coat of blown Hot Bitumen of Grade 85/25 @ 1.20 kilogram per square metre on primed surfaces. c) S&F standard APP modified membrane prefabricated 5 layer 3mm thick with non woven polyster matt centeral core of 160 gsm (mini) impregrnated and coated on both sides with layers of APP modified bitumen and finised with micro perforated heat fusiable polythene film on both surfaces .the weight of membrane shall not be less than 3.5kg/sqm and laid over primed surface by LPG/ butane torch, all as per manufacturers instructions. d) M&L applying two coats of solar reflective bitumen aluminium paint @ 0.1 ltr/Sqm per each coat complete all as directed
M&L for 75mm Cement concrete Type C-2 1:3:6 (40mm graded aggregate) for plinth protection complete all as specified and directed.
M & L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling, mass concrete etc complete all as specified & directed.
M&L for Chequered cement concrete tiles 30cm x 30cm x25mm thick with grey cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors over 15mm thick cement screed bed in cement and sand mortar 1:6 complete all as specified.
M&L for post construction antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc complete all as specified and directed.
Post construction antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for treating at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
M&L for preparing old painted steel and iron surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of previously treated wood or wood based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old decorated wall surfaces and applying one coat of exterior emulsion weather coat, complete all as specified and directed. Make: ’Apex weather proof exterior emulsion XP' or equivalent in Asian make as approved by GE.
S&F in repairs, vitreous china wash hand basin white countertop including cutting for and pinning in ends of brackets or erecting stand including brackets, PVC waste pipe and coupling of suitable size including removal of debries off the premises complete all as directed
S & F in repairs Vitreous china Urinal, half stall type, white (Excluding flushing cistern, flush pipe and waste pipe), PVC Connection pipe 15mm bore, 450mm long with PTMT nuts, Push tap of 15mm size any colour high pressure of PTMT screwed for iron pipe and fixed (Minimum weight 15mm-47gms/20mm-75gms), Urinal Spreader of any colour for fixing with 15mm dia pipe (Minimum weight 60gms) complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in any type of soil, complete all as specified and directed.
Surface dressing in soft/loose soil n exc 15 cm deep complete all as specified.
Removing surplus excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
S&F Mild steel, plain, black sheet 1.60mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required etc complete.
S&F MS Hook heavy duty for hanging of fire extinguiser as per sample kept in GE office complete all as specified.
Material & labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth(without using extra cement) complete all as specified and as directed.
M&L for Preperaing new plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer all as specified.
Mild steel TMT bars 10 mm dia and over, cut to length, bent ot shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified
M&L Hardcore of Broken stone / boulders of gauge n.exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled/rammed to a true surface complete all as specified
M & L for machine cut kota stone slab flooring 18-20 mm thick over and including screed bed or bedding layer 20mm thick in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
M&L Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at the length n exe 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete.
S&F Non - skid joint free Ceramic colour tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
All as per item here in before but in skirting in CM 1:3 , 10mm thick.
M&L, 7 to 8mm thick coloured, joint free Non skid ceramic tiles of size 400 x 400mm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including screed bed or bedding layer 15mm thick in cement mortar 1:4 complete all as specified and as directed. Note: Shade, design/pattern of tiles shall be as approved by GE
Taking up or down GI tubing incl connections of 15 mm dia bore complete all as specified.
Cutting chases, in stone walls, pinning in, making good to facing where required and pointing in cement mortpor 1:3 for concealed water tubing and making good, cuting exc, 10 cm but n.exc 20 cm girth complete all as specified and directed.
Supplying and laying 20 mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F in repairs first quality vitreous China wash down water closet pan (pedestal pattern), white, of size not less than 400mm x 400mm x 340mm (excluding fixing bolts, flushing cistern and flush pipe) but including provision of plastic water closet seat, white , closed pattern with flat bottom, and cover and mild steel chromium plated hinging device complete all as specified and directed.
S&F 15mm bore, bib taps, fancy type cast copper alloy Chromium plated screwed down for iron pipe for brass ferrule and fixed complete.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F 15mm bore two way bib taps, fancy type, chromium plated, cast copper alloy, screwed down, screwed for iron/GI pipe or for brass ferrule complete all as specified and directed.
S&F in repairs, 15mm bore Stop cock/angle valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure, screwed both ends for iron/GI pipe or for union complete all as specified and directed.
Demolition and breaking up drain pipes of 100mm dia complete all as specified.
S&F PVC(SWR) 75mm bore pipes single socketed in any length with rubber ring joints fixed to walls/floor complete all as specified and directed
S&F PVC (SWR) 110mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) 75mm bore floor trap with grating incl jointing to waste pipe and fixed in cement concrete type B-1 (1:2:4) all as specifed
S&F PVC (SWR) 110mm bore bend, any radius.
S&F PVC (SWR) 75mm bore bend, any radius.
Taking down and refixing in the same opening after easing & adjusting shutter of size exc 1 sqm and n exc 2 sqm each complete all as specified.
S & F Factory made single extruded WPC(Wood Polymenr Composite) solid door/window/Ceosetory windows and other Frames/chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated witgh miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame densityy of 750 kg/cum, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), miimum compressive strength of 58 N/mm2, modules of elasticity 900N.mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of requred dia and length complete as per direction of Engineer-in-charge. (M.S hold fast/lugs or SS dash fasteners shall bne paid for separately) manufacturers instructions and as directed by Engineer-in-Charge.
S&F Factory Made single extruded WPC (Wood polymer composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powedr/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face ) and 900 N (Edge), minimum compressive strength 50 N.mm2, modulus of elasticity 850 N.mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hings of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge.
S&F 100 mm size stainless steel butt hinges complete all as specified and as directed by the Engineer-in-Charge
S&F 150 mm size Alluminium, anodised barrel tower bolts of extruted section complete all as specified and as directed by the Engineer-in-Charge
S&F 250mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed .
S&F wall anchor bolt Fasteners 8mm dia for concrete and masonry walls complete.
M&L for PCC 1:1-1/2:3 type A0 using 12.5mm graded mechanically crushed stone aggregate of thickness exceeding 15mm and not exceeding 25mm in repairs of RCC beams, roof and chajjas including setting coat 5mm thick rendering in CM 1:3 with chicken wire mesh and necessary form work complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan,socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed by the Engineer-in-charge. Note: Serviceable tube light fitting to be reused under respective item for fixing only.
Taking down carefully MCB DB SPN/TPN, Metal P&S alongwith MCBs complete and taking credit all as specified and as directed by the Engineer-in-charge.
M& L for point wiring complete with 1.5 sq mm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough existing PVC Conduit including provisoin of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, including teminal box and hylum sheet of suitable module and for fixing switches /sockets/ regulators etc.all specified for :-
One light point controlled by one way switch .
One ceiling fan/ exhaut fan point controlled by one way switch.
One 3 pin socket outlet 5 Amps on the same board with other switches.
One 3 pin socket outlet 5 Amps independent but in the same vertical plane
One Light Control By Two way Switch
All as per item here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by the Engineer-in-charge.
S&F Switch Piano, flush type single pole, one way 5 Amps.
S&F Socket outlet 2 in 1, 3 pin, 6A flush type
S&F Switch socket combination, 2 in 1, 3 Pin, flush type 5 Amps.
S&F switch socket combination, 2 in 1, 5 Pin, flush type 5&15 Amps.
S&F stepped type electronic fan regulator flush type
S&F two way switch 5 A flush type
M&L for Sub main wiring complete with two runs of 2.5 Sq mm Single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with One run of 2.5 Sq mm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including suitable size of PVC conduit and accessories complete all as specified and directed. Note: Two run of 2.5 sqmm cable and one run of earth wire and one run of conduit shall be measured and paid as one unit length
M&L for Sub main wiring complete with four runs of 10 Sq mm Single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with One run of 10 Sq mm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing PVC Conduit including taking down old u/s sub main wiring complete all as specified and as directed. Note. Four run of 10 sqmm cable and one run of earth wire and one run of conduit shall be measured and paid as one unit length.
Cutting chases in stone masonry wall/concrete floor/roof for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 10cm girth.
S&F Rigid non-metallic PVC conduit of outer dia 20mm inclusive of all junction box, tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative batten type with driver, holder LED tube light fitting connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Fixing only tube light fitting of 20 W / 10 Watt complete retrived from taking down (item no.69) complete all as specified by Engr-in-Charge
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer in Charge
S&F ceiling rose 3 terminal PVC/Polycarbonate insulated body.
Taking down existing ceiling fan/ Exhaust fan from it's position and re-fixing the same after cleaning the dust and connecting up including provision of cable from ceiling rose/ connector to fanall as specified and as directed.
Providing suitable hole in brick /stone masonary or any type of wall for exhaust fan of upto 300 mm sweep and repair to the wall to give smooth finish as existing to the disturbed surface of wall all as specified and as directed
Supply and fix louvers/shutters made of galvanised sheet to open and close opening/hole made for exhaust fan of size 300 mm dia automatically complete including necessary plaster work for edging the hole complete all as specified and directed by Engineer-in-Charge.
Supply & fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame complete all as directed by Engr-in-Charge.
Supply & fix vertical mounted MCCB (Moulded Case Circuit Breaker) DB TPN 4 way of IP 43 protection double door with insulated bus bar assembly, neutral bar all as specified and directed. (Note: Incomer MCCB & outgoing MCBs will be measured and paid seperately). Make : Legrand / Indo Asian/ABB/Havells/L&T
Supply & fix MCB DB TPN 8 way double door with neutral bar etc all as specified and directed. (Note: Incomer & outgoing MCBs will be measured and paid seperately)
Supply & fix MCCB (Moulded Case Circuit Breaker) upto 63 Amps, 16KA, 3 pole, 415V suitable for all as specified and directed.
Supply & fix MCB TPN 40 AMP, 10KA, C Curve, 240V all as specified and directed.
Supply & fix MCB TP 40 AMP, 10KA, C Curve, 240V all as specified and directed.
Supply & fix MCB SP 6-32 Amps, 10KA, C Curve, 240V all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600mmx 600mm x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal gound level, earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 4 mm galvanised iron wire as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 40mm dia med grade GI Pipe for protection of galvanised iron strip in the ground further connecting with GI wire 4mm dia to Distribution board, including excavation, earth work, charcoal, Magnesium sulphate 50 Kg, Bentonite 25 Kg, PCC Chamber, RCC Cover slab, watering pipe 20mm dia bore med grade wire net, funnel etc & testing on completion all as specified in plate No 3 of SSR Pt-I including taking down old u/s earthing . Note . (a) GI Pipe for protection of earthing wire and earth strip beyond 7.5 mtr or test point shall be measured and paid seperately under relevant items.
M&L for GI wire 4mm dia as earth continuity wire including taking out the old unsv earthing lead
Removing and refixing Solar Water heater complete set of capacity upto 200 litres including electrical/water connections complete all as specified and as directed
Supply and Fix Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
Supply and laying 50 mm dia GI tubing medium grade ISI marked with all fittings, laid in trenches complete all as specified and as directed for the following sizes. Make:TATA / JINDAL / PRAKASH.
Supply & fix in repairs 50 mm dia bore brass ball Vales, screwed female ends to IS 554 / BS 21 / ISO 7, full bore, two piece design, quarter turn, lever operated, provided with forged brass hard chrome plated ball, premium quality PTFE gland packing and seating on iron pipe line and fixed properly of following sizes including taking out unserviceable gun metal gate / ball valve Make: Zoloto / Leader / Tiger / Cresent.
Supply and fix Submersible Pump starter DOL type suitable for 3 to 5 HP submersible pump, In Sheet Enclosure mounted on 2Nos. of 1.2m long, 40x40x5mm size angle iron stand duly grouted in PCC 1:4:8, 415V, 50Hz, 3 phase, Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1, with Protections - Overload, Single Phasing, Phase reversal, Phase imbalance Auto Restart Feature Vibration proof enclosure with IP54 protection class, Indications Offered - ON/OFF, Voltage and Ampere all as specified and as directed bu Engineer-in-Charge. Make: L&T / GE / Siemens /Havells/Schneider.
Supply and fix 3 phase submersible open well pumpset of capacity 5 HP , 380 volts and connecting to delivery line complete installation , connection of starter ,testing etc., complete all as specified and as directed
M&L for providing PCC Type D-2, 1:4:8 using 40 mm stone aggregate in the base of path complete all as directed.
M&L for Submersible Copper cable 3 core 6 Sqmm PVC insulated
Supply and installation, testing and commissioning of silent Diesel Engine driven generating set 40 KVA/32KW, with acoustic enclosure, 415 volts, 3 phase, 4 wire engine as per IS-10001/10002 and alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on mains failure, control panel having metre and sound proof canopy as per CPCB- IV Norms and foundations etc, developing 56 BHP @ 1500RPM, liquid cooled, electric start coupled alternator as per IS:13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, sound proof canopy, with the following provisions for DG Set complete all as specified and directed. Make : Kirloskar Green /Cummins India Ltd/ Greaves Ltd
(a) Diesel Engine : The engine shall be multi cylinder four stroke, 1500 RPM, Radiator water / coolent cooled, turbo charged complete with instrument panel, electronic governer, starting battery with lead, exhaust pipe and silencer pipe with suitable insulation by glass wool aluminium cladding, safety devices and other standard fittings etc complete as per IS-10000 Part -II (1980) and BHP suitable to the governer as specified.
(b) Alternator : The alternator should be desined for an output of 40 KVA continuous rating at 0.8 PF conforming to IS-4722 or BS-2613, for 1500 RPM including self exiting and self regulating control panel with accessories brush less design, electirc supply terminal box with gland earth terminal etc complete all as specified.
(c) Fuel Tank: The fuel tank shall be mild steel suitable to hold fuel for not less than 12 hours running capacity and shall be including fuel level indicator, fuel line from tank to the engine etc complete all as specified
(c) Generator monitoring panel - comprising of all standard items as mentioned under this schedule or as per standard practice of manufacture, ignition key switch, start/stop arrangement indication for engine parameters, hour run meter, RPM meter, engine oil pressure indication, water/coolant temparature indication, battery volts display, annunciation with indication lamps for, low lube oil pressure, high water temperature, engine over speed, battery low voltage complete.
(d) AMF Microprocessor operated control unit of suitable capacity for automatic operation of DG set and power contactors. Make : Legrand, havell or equivalent. This control unit shall be installed on floor/ wall mounting, in generator monitoring panel or in AMF panel as per manufacturers recommendations. (ii) MCCB 415V. 3 phase 100 Amps adjustable, 35 KA-02 (one for main supply & one for DG set supply) (III) Suitable Power contactor four pole - 02 Nos (one for main supply and one for DG set supply) (iv) Copper bus bar TPN 100 Amps - 01 set (v) Suitable battery charging unit -01 No (vi) DIgital multifunction meter for display of voltage, current, frequency, KVA, KW, KWH and PF. (vii) Electronic hooter (viii) Indication lamp for main ON, load mains, DG set ON, load on DG set, Battery DC supply ON. (ix) Voltmeter and ammeter for battery charging. (x) Suitable for MCBs for control circuit. (xi) Supply and lay control cable LT 1100 volts PVC insulted armoured heavy duty copper conductor of suitable size multicore (from DG set monitoring panel to AMF panel) (xii) Rubber matting of LV grand 19mm thick of suitable size chequered.
(e) Battery: Suitable maintenance free battery with leads and terminals as per OEM recommendations
(f) Civil Work - All civil works including PCC platform and foundation suitable for installation of DG set alongwith anti vibration pad. The depth of foundation & PCC shall be as recommended by the manufactures. Rate quoted is deemed to be inclusive for this provision.
Notes:- (i) LT UG cable for connection between generator and AMF panel will be masured and paid seperatly. (ii) Diesel, grease, engine oil etc required for commissioning and testing shall be supplied by the contractor and cost deemed to be included in the above offer. Testing shall be carried out as specfied in particular specifications. (iii) DG Set shall be provided with suitable size of acoustic enclosure provided with inside ilumination with LED fitting, the enclosure is duly epoxy coated and sound insulation to reduce noise level as per guide of Central Pollution Control Board or least CPCB norms and OEM specification & approved by Nodal agency, cost of same deemed to included in the qouted rate.
Supply & Laying LT UG Cables , XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, of 50 Sqmm, 3.5 Core, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe including cable glands and cable lugs for conecting up with control gear complete all as specified and directed.
M/S P.SWAROOP KUMAR (BID ID -3399851)
K P R ENTERPRISES (BID ID -3392067)
NEWS CONSTRUCTIONS (BID ID -3392758)
KOGANTI CONSTRUCTION COMPANY (BID ID -3391744)
RAJU AND COMPANY (BID ID -3400484)
M/S AMRIT DAS MAHAPATRA (BID ID -3400109)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .