Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹19.9 L+₹51,235 (2.64%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical 0 0 MOH SITARGANJ PIPRI POST UKHLI KATRA SHAHJAHANPUR UTTAR PRADESH 242301 SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242301 | SHAHJAHANPUR | UTTAR PRADESH | 242301 | - | Rejected-Technical Not approved for opening of financial bid as firm is not enlisted in category c(i) as per tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
22 Mar 2021, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR Pin-273008
REPAIR/MAINT OF WINDOW AC, SPLIT AC AND OTHER SUMMER / COOLING APPLIANCES AT AF STN GORAKHPUR.
2021_MES_428080_1
8758/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE(AF) GORAKHPUR
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE(AF) GORAKHPUR
₹40,000
Yes
5 Apr 2021
5 Mar 2021
23 Mar 2021
5 Mar 2021
22 Mar 2021
10 Mar 2021
Amount
Servicing of window type AC of capacity 1.5/2.0 ton of any make/ model including removing the AC and cleaning, oiling, servicing and checking for proper functioning and re-fixing at site complete all as specified and directed. Note:- Spare parts will be measured and paid separately
Servicing of split type AC of capacity 1.5/2.0 ton of any make/ model including removing the AC and cleaning, oiling, servicing and checking for proper functioning and re-fixing at site complete all as specified and directed. Note:- Spare parts will be measured and paid separately
Checking of window / split AC / water cooler / desert cooler, taking out unserviceable parts like wise relay, compressor, blade, motor, gas leakage, condenser coil, capacitor, thermostat, filter, PCB, wiring etc and all mechanical accessories in day to day and making it serviceable in all respect with replacement of any major part but including minor repairs adhesive cable and other connected accessories by providing sufficient and skilled manpower, work shall also include to check & removal of leakage in window / split AC / water cooler / deep freezer as and when directed complete all as specified and directed. The scope also include complete checking of window/ split/ summer appliances. Note:- (a) The rate quoted by the contractor for Each job is deemed to be included all minor repairs. (b) The contractor or his representative will take complaint from MES complaint register through MES Job card. (c) The contractor will made separate items register with location and signature of user. (d) The contractor will maintain complete detail of JOB card and items involved with date and user signature. (e) The ladder and T&P as required will be provided by the contractor (f) Risk Factor will be on the contractor's ends.
Dismantling of window / Split type 1.5 ton Air conditioner and replacing the burnt sealed compressor (Rotary Type) unit by new sealed compressor including all other works such as cleaning and gas charging and re-fixing at site complete all as specified and directed.
Supply only in replacement condenser coil for 1.5 ton window type A.C. complete all as specified and directed.
Supply only in replacement relay for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- Microtech / Renutron
Supply only in replacement overload protector for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- Microtech / Renutron
Supply only in replacement starting capacitor 100-120 MFD, for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- Teslla or equivalent
Supply only in replacement running capacitor 36 MFD, for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier
Supply only in replacement running capacitor 45 MFD, for 1.5/2.0 ton window / split type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier
Supply only in replacement thermostat switch, for 1.5 /2.0 ton window / split type A.C. complete all as specified and directed.
Supply only in replacement air filter for 1.5/2.0 ton window type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier
Supply only in replacement air filter for 1.5/2.0 ton split type A.C. complete all as specified and directed. Make:- LG / Voltas / Carrier
Taking down electronic circuit board (PCB) of window / split type A.C. 1.5/2.0 ton for repairs and fixing the same after repair complete all as specified and directed.
S&F in replacement electronic circuit board (PCB) of window / split type A.C. 1.5/2.0 ton complete all as specified and directed.
Supply only in replacement wiring kit for 1.5/2.0 ton window type A.C. complete all as specified and directed.
Supply only in replacement capacitor 4/6 mfd complete all as specified and directed.
M&L for rewinding of blower motor for 1.5 ton A.C. with superior quality of super enameled copper wire of appropriate sizes in existing weight and gauge including replacement of Bush / Bearing complete all as specified and directed.
All as per item No. 17 above but inner unit of split type AC.
Supply only blower motor for inner unit of 1.5 ton A.C. with superior quality of super enameled copper wire complete all as specified and directed.
Supply only fan motor for outer unit of 1.5 ton A.C. with superior quality of super enameled copper wire complete all as specified and directed.
M&L for gas charging in window type A.C. unit of 1.5/2.0 ton capacity using refrigerant gas as per standard practice after flushing, vacuuming including detecting leakage, rectification of leakage, commissioning and testing upto sufficient pressure complete all as specified and directed.
All as per item No. 22 above but for split type A.C.
S&F in replacement of sheet metal enclosure with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
S&F in replacement of copper tubing 1/2" heavy duty complete all as specified and directed.
S&F in replacement of copper tubing 1/4" heavy duty complete all as specified and directed.
S&F in replacement of copper tubing 5/8" heavy duty complete all as specified and directed.
S&F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 4 Sqm complete all as specified and directed.
S&F in replacement of PVC insulated & sheathed flexible 3 core copper cable of 6 Sqm complete all as specified and directed.
Supply only in replacement of new remote control for split / window type AC 1.5 ton/2.0 ton capacity with battery complete all as specified and directed.
S&F in replacement of new brasmetic hand shut off valve for split type AC complete all as specified and directed.
Installation / re-installation only split type A.C. electrically driven, 230/250 Volt, AC 50 Hz capacity 1.5/2.0 ton with high wall mounted type fan coil unit (FCU) to be fitted in wall with rowl plug including making holes for inlet / outlet in the wall and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including S&F of unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed.
S&F in replacement auto swing motor for window/split type AC 1.5/2.0 ton complete all as specified and directed.
S&F in replacement fan blower set for 1.5 ton split type AC (as per sample) complete all as specified and directed.
M&L for replacement of unserviceable sealed unit of water cooler with new sealed unit for 200 SF 40/40 litre capacity of water coolers complete all as specified and directed. Make: Kirloskar / Tecumsaw
All as per item No. 35 above but for 300 SF 80/80 litre capacity of water cooler.
Supply only in replacement relay assembly for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Microtech / Sriram
All as per item No. 37 above but for 300 SF 80/80 litre capacity of water cooler.
Supply only in replacement overload protector for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Kirloskar / Tecumsaw
All as per item No. 39 above but for 300 SF 80/80 litre capacity of water cooler.
Supply only in replacement starting capacitor for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Usha / Teslla / Universal / Blue star / Gulmerg
All as per item No. 41 above but for 300 SF 80/80 litre capacity of water cooler.
Supply only in replacement running capacitor for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Usha / Teslla / Universal / Blue star / Gulmerg
All as per item No. 43 above but for 300 SF 80/80 litre capacity of water cooler.
Supply only in replacement thermostat switch for water cooler complete all as specified and directed. Make: Indofoss or equivalent of specified make
S&F in replacement of chromium plated push cock, self closing, spring loaded type 15 mm dia, with water waste tray for water coolers complete all as specified and directed.
M&L for gas charging in water cooler by using refrigerant gas as per standard practice after proper flushing vacuuming detecting leakage, commissioning and testing complete for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed.
All as per item No. 47 above but for 300 SF 80/80 litre capacity of water cooler.
M&L for repair to refrigerator 165 to 190 litre capacity complete by cleaning of system properly with CTC, charging refrigerant gas including replacement of unserviceable sealed unit (Compressor) of refrigerator with new sealed unit, complete all as specified and directed. Make: Kirloskar / Tecumsaw
All as per item No. 49 above but for 210 to 315 litre capacity of refrigerator.
S&F in replacement of box type relay for any make and capacity of refrigerator complete all as specified and directed. Make: Microtech / Renutrol
S&F in replacement condensing coil for 165 to 190 litre capacity of refrigerator complete all as specified and directed.
All as per item No. 52 above but for 210 to 315 litre capacity of refrigerator.
Supply only in replacement condensing coil for 200 SF 40/40 litre capacity of water cooler complete all as specified and directed. Make: Usha / Teslla / Universal / Blue star / Gulmerg
All as per item No. 54 above but for 300 SF 80/80 litre capacity of water cooler.
M&L for gas charging by using refrigerant gas as per standard practice after proper flushing vacuuming detecting leakage, commissioning and testing complete for 165 to 190 litre capacity of refrigerator complete all as specified and directed.
All as per item No. 56 above but for 210 to 315 litre capacity of refrigerator.
All as per item No. 56 above but for 180 to 310 litre capacity of Deep fridge.
S&F in replacement vertical water lifting pump, single phase, 1/7 HP or any HP suitable for desert coolers complete all as specified and directed. Make: Summerking / Summer cool / MEI / Crompton
S&F in replacement fan motor, single phase, 1/7 HP or any HP suitable for desert coolers complete all as specified and directed. Make: Summerking / Summer cool / MEI / Crompton
S&F in replacement wood wool pad for desert cooler of suitable size with connected access complete all as specified and directed. (one set of 3 nos)
M&L for rewinding of 5 KVA main transformer of voltage stabilizer using superior quality of super enameled copper wire of core matching size complete with varnishing dying and refixed in stabilizer complete all as specified and directed.
All as per item No. 62 above but for 4 KVA.
S&F in replacement of PCB matching size of voltage stabilizer 5/4 KVA of single phase operation in AC supply complete all as specified and directed.
S&F in replacement of TDR for voltage stabilizer 4/5 KVA complete all as specified and directed.
S&F in replacement of voltmeter 0-300 volt for voltage stabilizer 4/5 KVA complete all as specified and directed.
S&F in replacement of MCB SP 20A for voltage stabilizer 4/5 KVA complete all as specified and directed.
S&F in replacement of thermostat for any make and capacity of refrigerator complete all as specified and directed. Make: Microtech/Renutrol
S&F in replacement of switch Assembly 5A as per sample complete all as specified and directed.
S&F in replacement of plug top 5A/15A as per sample complete all as specified and directed.
S&F in replacement of push cock CP 15 mm dia for water cooler complete all as specified and directed.
M/S SHANKER TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .