| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 WB | KOLKATA | WEST BENGAL | 700026 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹45.9 L+₹1.4 L (3.11%)Rejected-Finance 197 PATHAK PARA ROAD KOLKATA 700060 | KOLKATA | KOLKATA | WEST BENGAL | 700060 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹47.2 L+₹2.6 L (5.93%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹50.6 L+₹6.0 L (13.5%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹52.4 L+₹7.9 L (17.7%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.4 L
EMD Value
₹78,760
Closing Date
31 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) KOLKATA
D9 COMMISSARIAT ROAD HASTINGS KOLKATA 700022
ADDN/ALTN TO COOK HOUSE IN BLDG NO. BI-1A INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2021_MES_455806_3
GE(FW)/KOL/8742/E8
Open Tender
Civil Works
Item Rate
180 days
FORT WILLIAM KOLKATA
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE(FW) KOLKATA
₹78,760
Yes
29 Oct 2021
18 Aug 2021
1 Sept 2021
18 Aug 2021
31 Aug 2021
18 Aug 2021
60 days
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling of Asbestos cement corrugated, semi-corrugated sheet in roof covering complete all as a specified and as directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No. 3 above but fixing only old serviceable sheets obtained from dismantling
All as per Item No. 3 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
Dismantling structural steel work with mild steel sheet covering as in doors, gates, hangar doors etc but excluding framed trusses complete all as specified and directed.
M&L for cutting holes in brick wall exceeding half brick but not exc one brick thick walls for inserting hold fasts for mild steel grills and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 (using 20 mm graded aggregates) including necessary formwork and making good surfaces as per existing finisjhes complete all as specified and directed.
S&F Expanded metal cut to length bent to shap required and tying with and including annealed mild steel wire not less than 0.9mm dia weight exceeding 4 Kg per Sqm or fixing with galvanised steel staples fixed to wooden of steel frame including all rebating etc complete all as specified and directed.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed.
M&L mild steel in framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed by Engineer-in-Charge.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ fly-ash Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B1 usi ng 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like includinguding weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
Taking down cement plaster on brick or concrete surfaces incl racking out joints, hacking for key, scrubbing down with water etc. all as specified and directed.
M&L 15mm thick cement plaster on brick or concrete walls in cement mortar 1:6 finishing even and smooth without using extra cement complete all as a specified and as directed
M&L for dubbing out cement plaster (1:4), average 10 mm thick on irregular faces of walls (when specially ordered in writing) complete all as a specified and as directed
M&L rendering 15mm thick on fair faces of brickwork or concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound as per manufacturer's instruction, surfaces finished even and smooth without using extra cement complete all as a specified and as directed. (NOTE: Water proofing compound shall be measured and paid seperately)
Supply only liquid water proofing compound all as specified and as directed.
M&L for preparation of wall surfaces and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 2 mm thick wall putty complete all as specified and directed.
M&L for complete removal of old treatment on walls and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over 2 mm thick wall putty complete all as specified and directed.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L preparation of new or previously untreated wooden or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as specified and directed.
M & L applying one coat of synthetic enamel paint on old steel surface of any description over 10 cm width or girth incl preparation of surfaces complete all as specified and directed.
M & L applying one coat of synthetic enamel paint on old wooden surfaces of any description over 10 cm width or girth incl preparation of surfaces complete all as specified and directed.
Grinding of existing floor such as kota stone, terrazo floor, mosaic floor, etc of any description with carborundum stone and cleaning with oxalic acid complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
M&L joint free non skid ceramic 7 to 8 mm thick coloured tiles, joint free, (square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, set and jointed in neat cement slurry and pointed in white cement mixed with pigment as in floor, laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
-ditto- but as in skirting, fixed over 10mm thick screed bed in cement mortar 1:4.
M&L glazed coloured ceramic tiles in vertical surface 300 X 450 X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and including 10mm thick screed bed in cement mortar 1:3 complete all as specified and directed.
S&F for mild steel stack clamps, fabricated out of 50 x 5 mm flat iron and 16 mm dia round iron stay, including suitable size bolts and nuts and securing ends of stays to wall or roof for 150/160 mm dia pipes including painting with two coats of synthetic enamel paint over coat of red oxide primer complete all as specified and directed.
S&F in repair galvanized, plain mild steel sheeting 0.8 mm thick, with minimum zinc coating of 120 gram/Sq m, as in ridge, hips, valley gutters, drip and straight flashing, complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over 20 mm thick screed bed in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed by the Engr-in-Charge.
-ditto- but kota stone in riser of steps, skirting etc fixed over 10 mm thick screed bed in cement mortar 1:3 complete
M&L granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for applying two coat of exterior acrylic emulsion weather proof paint over a coat of suitable exterior primer (as per manufacturer's instructions) after applying 2 mm thick wall putty to newly plastered surfaces of walls of any description, over 10cm width or girth not otherwise described, including preparation of surfaces complete all as specified and directed.
M&L for removal of existing treatment on walls and applying two coat of exterior acrylic emulsion weather proof paint over a coat of suitable exterior primer (as per manufacturer's instructions) after applying 2 mm thick wall putty to newly plastered surfaces of walls of any description, over 10cm width or girth not otherwise described, complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as directed.
Taking down shutters of any description n.exc 1.00 Sqm each all as directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each all as directed.
S&F for 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
S&F 35mm thick Factory made 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc. with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as directed.
All as per item no. 46 above, but 30 mm thick for windows, ventilators etc, provided with stiles and rails as specified in SSR Part-I section 8 clause 24(b) with sash bars
All as per item no. 46 above, but 30 mm thick for windows, ventilators etc, provided with stiles and rails as specified in SSR Part-I section 8 clause 24(b) without sash bars
S&F 2nd class hard wood factory made 35mm thick plain, framed, panelled shutters (two panels), with lock rail and panel of 9mm BWP commercial ply or 12mm verneerd particle board with commercial veneering on both faces the size of rail and stile as per IS: 1003 (Part 1) Kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, treating ends of posts, back of chowkhats etc, with tar or coal tar black paint, area tarred exc 0.1 sqm but n. exc 0.5 sqm each complete all as specified and directed.
-ditto- but treating small articles such as holdfasts, ends of posts, back of chowkhats, etc, area n exc 0.1 sqm each
M&L mild steel small articles such as flat iron 25x3 mm thick for hold fasts etc, conforming ti Fe 410-0 or 310-0 complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregates) for fixing of holdfasts, finished to match with existing surfaces including necessary formwork complete all as specified and directed.
S&F 100 mm long mild steel butt hinges (medium weight) cold rolled complete all as specified and directed.
All as per item no. 54 above, but 75 mm long hinge
S&F 200 mm aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
All as per item no. 56 above, but 150 mm long tower bolt
S&F 300 mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
S&F 150mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
All as per item no. 59 above, but 125 mm long handle
S&F floor door stopper of aluminium alloy body and tounge, anodised, with hard drawn steel spring, fixed in floor. 150mm overall length of cover plate complete all as a specified and as directed
All as per item no. 59 above, but brass floor door stopper
S&F stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
-ditto- but including taking down of existing wire cloth
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq m in each pane complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches/or fixed on walls, of 100 mm internal dia complete all as specified and as directed.
All as per Item No. 66 above, but for 150 mm bore cast iron/RCC pipes
S & F Cast iron (sand cast) soil, waste and vent pipes 100 mm bore of any length with or without ears with cement joints all as specified, fixed on walls complete all as specified and directed.
All as per Item No. 68 above, but for 150 mm bore cast iron pipe
S & F CI bend (any radius), diminishing pieces or tapers (larger bore measured) for 100 mm bore pipe complete all as specified and directed.
All as per item No 70 here in before but for 150mm bore pipe
Taking up or down existing steel tubing and connection, 20 mm bore and keeping aside for re-fixing or removal to store complete all as specified and directed.
All as per item No 72 here in before but for 15mm bore pipe
Supplying, fixing, jointing and testing galvanised iron tube, 20 mm bore, medium grade with all fitting fixed to walls and ceiling or laid in floors complete all as specified and directed.
All as per item No 74 here in before but for 15mm bore pipe
Dismantling of water tanks exc 500 Ltrs and n exc 1000 Ltrs capacity, after disconnetion of incoming and outgoing water lines and removal from site complete all as specified and directed.
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 1000 Litres, multi-layered (ISI marked), with GI tank nipple & cover, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed.
S&F 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-152 or equivalent model in JEXON / POLYTUF / SHAKTI)
M&L for mild steel wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified. (NOTE: Measurement shall be taken for the ms flat only. Quoted rate is deemed to include for the cost of securing bolts etc)
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description not exc 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
Dismantling of ceiling board alongwith snap grid frame of any thickness complete all as specified and directed.
S&F Suspended metal grid Ceiling System with mineral fibre acoustic tiles as per following specifications:- a) Ceiling Tiles:- Mineral fibre acoustic tile of 16mm thickness having sand textured finish with acoustical punchers, bevelled tegular edge and 8mm drop in module size of 600 x 600mm. Tiles shall have humidity reistance (RH) of 99%, NRC 0.50 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 33db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of class 0/1 as per BS 476 Part 6/7 and Class A as per ASTM E84. b) Metal Grid:- The grid system shall be 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”.
(Item No. 82 Contd....) All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. The ceiling grid sections shall be fixed to ceiling with 6 mm dia GI hangers upto required length by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5mm dia 40 mm long. MAKE OF CEILING GRID : ARMSTRONG, Model: SUPRAFINE 38 or equivalent in GYPROC / USG BORAL / UNISTEEL MAKE OF CEILING TILES: ARMSTRONG, Model: DUNE or equivalent item in GYPROC / USG BORAL / U TONE)
SCHEDULE 'A PART-II (INT ELECTRIFICATION) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No. 84 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 84 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box).
All as per item No. 84 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box).
PIANO SWITCH, 5/6 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type
PIANO SWITCH, 15/16 AMPS, SINGLE POLE, ONE WAY
S & F new Switch piano, flush type
SOCKET OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new socket outlet, flush type
SWITCH SOCKET COMBINATION OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS,
S & F new switch socket combination outlet, flush type with indicator lamp
SOCKET OUTLET, 5 PIN, 5/6 AMPS,
S & F new socket outlet, flush type
SWITCH SOCKET COMBINATION OUTLET, 3/5 PIN, 5/6 AMPS,
S&F new switch socket combination outlet, flush type
CEILING ROSE, THREE TERMINALS, 240 VOLTS
S&F new Ceiling rose, surface type
FAN REGULATOR, STEPPED TYPE, 5 SPEED CONTROL, 230/240 VOLTS
S&F stepped type electronic fan regulator, flush type
LAMP HOLDER, PVC/POLYCARBONATE BODY
S&F lamp holder with back plate suitable for batten/pendant fittings or to be mounted on walls
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, with LED tubelight, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size incl taking down existing fitting complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (d) having in built short circuit and surge protection (e) colour temperature not less than 5700 degree K (f) life not less than 25000 hours of operation
S&F in repairs surface mounted LED industrial luminaire, 2 X 18 Watt, 4 feet long, in polycarbonate housing, with LED tube lights, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size incl taking down existing fitting complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (d) Weather protection grade: IP65 (e) having in built short circuit and surge protection (f) colour temperature not less than 5700 degree K (g) life not less than 25000 hours of operation
Supply and Fix in repairs recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
NOTE FOR ITEM NO. 97 to 99 :- (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work. (2) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of work. The product will be replaced free of cost in following cases :- (a) Manufacturing Defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 metre) below 90% of claimed value of lumen (or lux at 1 metre) of the LED/luminaire. (d) Decision of GE in this regard shall be final and binding. (3) All LED/luminaire shall meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/Section 13. (4) The contractor shall submit the LM-80 and LM-79 test report as specified in Particular Specifications.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 4 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Five runs of single core 10.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 101 above but with two runs of 6.0 Sqmm cable and one run of 6.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 101 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
Material and labour for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
S&F DB, VTPN, 4 way, vertical type, IP 43 protection, double door (premium quality) 415 volts with provision for MCCB as incomer and MCB as outgoing and electrically connecting up complete all as specified and directed. (MAKE : LEGRAND, Cat No: 5077 45 / L&T, Cat No. DBVTL004DD / ABB, Cat No: E-SVTDB M 4XT1 /HAGER, Cat No: VYV04DM-P /SCHNEIDER, Cat No: A9HVD04L)
Supply and fixing TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
NOTE FOR ITEM NO. 107 to 110 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
Supply and fixing MCCB 4 pole, 415 volts 16 KA AC, 50 Hz , thermal magnetic release, 100 Amps capacity with Icu=Ics complete all as specified and directed. (MAKE : LEGRAND, Cat No: 4200 15 / L&T, Cat No: CM90518OOKO / ABB, Cat No : 1SDA066818R1 / SCHNEIDER, Cat No: LV426167 or equivalent item in HAGER))
Supply and fixing MCB, 'C' series, 4 pole, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.
Supply and fixing MCB, 'C' series, SPN, 40-63 Amps, breaking capacity 10KA complete all as specified and directed.
Supply and fixing MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
Supply and fixing MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
JAGATMATA ENTERPRISE
dutta and dutta
KWALITY CONSTRUCTION
M/S R G Construction
ARATI TRADING CO
PINKY CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .