Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | ₹43.0 L Quoted ₹45.4 L | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹45.5 L+₹11,659.50 (0.26%)Rejected-Finance | ₹45.5 L+₹11,659.50 (0.26%) | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
22 May 2025, 6:00 pmClosed
GE 860 EWS, Karu
GE 860 EWS, Karu Pin-194201
REPAIR/MAINT OF SOLAR POWER PLANT AND CONNECTED ITEMS AT SHESHARTHANG AND REPAIR/MAINT TO LT OH LINE FOR INSULATORS, ACSR CONDUCTORS, LT POLE PAINTING, LT POLES AND CONNECTED WORK SERVICES AT KARU UNDER GE 860 EWS
2025_MES_704742_1
8151/2025-26/E8
Open Tender
Civil Works
Item Rate
270 days
Karu and Shesharthang
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS, Karu
₹1 L
Yes
8 Jul 2025
19 Apr 2025
26 May 2025
19 Apr 2025
22 May 2025
3 May 2025
Amount
Replacement of unsv/broken by new solar photo voltaic modules panel type/model MBSLeLITE 60, 254.79 watt, rated voltage 30.89 V, rated current 8.25 Amp, crystalline silicon PV modules with spare/parts required for smooth functioning, tightenining of electric connection complete and assembling and reconnecting all as per site requirment all as specified and directed by Engr-In- Charge.
Repair/Servicing of Off grid inverter outdoor type incl replacement of unsv parts, IP-65 protection, 200 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, AC power string inverter on three phase side output voltage 415 V(+12.5%, 20% VAC) maximum current ripple 4% PP Reactive power 0.95 inductiveto 0.95 capacity, harmonic distortion less than 3% over all efficiencyof not less than 98%and above at full loadwith all protection (IEC61683), Operating temperature range -30 Degree Celcius to 60 Degree Celcius including making connection as per existing complete all as per site requirment all as specified and directed by Engr-In- Charge. The cost of replacement of unsv parts measured separately.
DC Relay
Boosting Capacitor
EMI Filter
Dismantling and taking down old u/s earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
Dismantling and taking down old u/s earthing and Material and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and as directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2Ώ the earthing will be redone at no extra cost
Dismantling and taking down old u/s earthing complete with copper earth plate 600mm x 600mmx 3.15mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 20x3 mm Copper strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion complete all as specified and directed. Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way. (ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
Replacement and fixing only Copper strip 20x3 mm from earth electrode to test point complete all as specified and directed.
Replacement and fixing only GI earth strip 25x4 mm from earth electrode to test point complete all as specified and directed.
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge.
Supply & fixing in replacement of Integral LED Flood light Luminaries 100 Watts consisting of suitable number of LEDs and mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover with secondary optics lens, IP 66 protection suitable for mast light mounting, 5700K, LED efficiency >130 lm/Watt and system efficiency 110 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -10ºC to 50ºC,built in surge protection of more than 10 kV , Confirm the tests from auth labs : LM79 & LM 80, incl proper fixing and testing of flood lights on 9/11 mtr long steel tubular pole and provide facility of power supply shall be provide as suitable for maint work of light fittings incl make proper connection of new and existing light fittings complete with cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge.
Supply and fixing in replacement or passing through PVC conduit pipe of single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed.
Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates complete all as specified and directed.
Supply and fixing in replacement MCCB TPN 400 Amps, 415 Volts, 50 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 500 Amps, 415 Volts, 50 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 100 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
M&L Servicing and Cleaning of Off grid inverter indoor type, IP-65 protection, 200 KW capacity, AC nominal rating (array to inverter ratio 1:1), 3 P, 50 HZ, including making fresh connection as per existing complete all as per site requirment all as specified and directed by Engr-In- Charge. Make: Optimal Model : Solar inverter GSC-200K(3P-0D-400-50-360-0K).
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, shafts, man holes,for under ground cable / erection of poles, stays, locating fault of LT cable and stay assembly etc not exceeding 10 square metre on plan and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and as directed.
Returning, filling in, in soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified and directed.
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and as directed. Note: Only punned thickness shall be measured and paid.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning complete all as specified and directed by Engr-in-Charge.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and directed by Engr-in-Charge.
Supply and laying, connecting and testing XPLE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4.0 core including Al thimbles laid in trenches/on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc. Note : (i) Earth work, sand, bricks removing, returning filling will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Descrition all as per item ser No. 22.00 here in before but for 4 core 16 Sqmm
Descrition all as per item ser No. 22.00 here in before but for 3.5 core 35 Sqmm
Descrition all as per item ser No. 22.00 here in before but for 3.5 core 95 Sqmm
Descrition all as per item ser No. 22.00 here in before but for 3.5 core 150 Sqmm
Descrition all as per item ser No. 22.00 here in before but for 4 core 400 Sqmm
Supplying and fixing light grade galvanised mild steel pipe 40mm bore and Making Flange end both side for extending ESE lightening arrestor with all fittings like nuts, bolts and washers and making good as existing, secure on ground with SWR (steel wire rope) complete all as specified and directed by Engr-In-Charge. Note:- Above quoted rate is included to secure additional length of SWR.
Supply, installing, testing & commissioning in replacement of outdoor type cubical LT feeder pillar panel box size 1.0Mx1.0Mx0.5m with double door type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and rear openable double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/openable by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl c0pper bus bar of 200 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :- a) On load Change over switch 200 Amps, TPN, 4 pole 415 Volts AC, -01 No. (b) outgoing MCCB 100 Amp, 10 KA, 4 pole, 415 volt AC, -01 Nos.
Material and labour for shifting heavy items / excavation / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley ect as required at site complete all as specified and as directed.
Supply Only PVC braided hose pipe size 01 Inch complete all as specified and as directed.
Material and laying for Steel water tubes ISI marked, medium grade galvanised, 20 mm bore with all fittings such as bends, elbows tees, slort, pieces, connections, back nuts,diminishing pieces caps, plugs and unions etc, laid in trenches or in floor with clamp including taking out of old unsv GI pipes complete all as specified and as directed.
Descrition all as per item ser No. 32.00 here in before but 25 mm bore.
Descrition all as per item ser No. 32.00 here in before but 50 mm bore.
S&F Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20 mm bore including taking out of old unsv gate valve complete all as specified and as directed.
Descrition all as per item ser No. 35.00 here in before but 25 mm bore
Descrition all as per item ser No. 35.00 here in before but 50 mm bore
Supply and fixing in replacement Rotational moulded polyethelene water storage tank triple layer ISI marked capacity 1000 ltr (cylinderical vertical with closed top) hoisted and fixed in position including making connection with existing pipeline complete all as per direction of Engr-in-Charge.
Supply and fix in replacement of Lithium based Energy Efficient Integrated Solar Street Light of 32 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 64/66Wp , Lithium Battery 11.1/12.8V, 33.0AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700°K - 6500°K, Microcontroller based charge controller cum driver, automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10°C to (+)55°C, weight not more than 16-18kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant including tubular pole 6 mtr height with bottom base plate 200x200x12 mm , outdoor dia not less than 65 mm with heavy duty GI pipe or steel thickness 3mm and suitable arrangement to mount solar light as directed on pole including foundation PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate and erection as per manufacturer drawing, providing synthetic enamel aluminium paint over one coat of red oxide complete all as specified and directed Make:- Axxon (AXN-32W) or equivalent of Phillips/Bajaj/wipro/havells
Supply and fixing in replacement of Inverter battery 12 volt, 150 AH, C-10 type, Solar Tubular type complete all as specified and directed by Engineer-in-charge.
Material and labour in replacement of broken earth pit of size 300x300x300 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result all as specified and directed.
Repairing of existing unserviceable PCC coping of supporting PCC blocks for solar paqnels by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of white wash all as specified and directed.
Supply and fixing in replacement of Surge protection Device (SPD) DC 1000 Volt in DC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of DC Fuse 15 Amp in Surge protection Device (SPD) DC 1000 Volt in DC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Surge protection Device (SPD) AC in AC Distribution box in Solar Inverter complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of PVC insulated Solar DC cable 6 sqmm 1.8 KV DC volt for solar plant copper cable including taking down complete all as specified and directed by Engr-In-charge.
Supply and fixing in replacement of cable connector for solar DC cable 6 sqmm 1.8 KV DC volt for solar plant copper cable including taking down complete all as specified and directed by Engr-In-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 m depth for foundation of poles and getting out in hard/dense soil, complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
S&F galvanized iron pipe of 80 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Description all as per srl item No. 50.00 here-in-before but for galvanized iron pipe of 50 mm nominal dia, complete all as specified and directed by Engr-in-Charge. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
M&L for PCC (1:3:6) type C2, using 40mm graded crushed stone aggregate as in coping of pole , with and incl necessary form work where required, fair finish to the exposed surfaces, complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:2:4) type D-2, using stone aggregate 20mm graded, with and incl necessary form work where required for pole foundation and fair finish to the exposed surfaces, complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D-2, using crushed stone aggregate 12.5mm graded as in foundation filling mass concrete, with and incl necessary form work where required and fair finish to the exposed surfaces, complete all as specified and directed by Engr-in-Charge.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 70 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
Description all as srl item No. 55.00 here-in-before but for cable size of 50 sqmm 3.5 core.
Description all as srl item No. 55.00 here-in-before but for cable size of 25 sqmm 4 core.
Description all as srl item No. 55.00 here-in-before but for cable size of 16 sqmm 2 core.
Description all as srl item No. 55.00 here-in-before but for cable size of 10 sqmm 2 core.
Labour only for taking down of old conductor of any description / size from LT Poles of any size, complete all as specified and directed by Engr-in-Charge.
S&F Aluminium conductor, steel reinforced (ACSR) of any size, straining properly on insulators and binding on existing LT poles or new poles with and incl 02mm dia aluminium binding wire,complete all as specified and directed by Engr-in-Charge. Note : The 3% for sag, joints & jumpers shall be added in measurements.
Labour only for taking down of old rusted GI wire of any description / size from LT / HT Poles of any size, complete all as specified and directed by Engr-in-Charge.
S&F contineous GI earth wire/gaurd/cradles of 4mm dia including GI binding wire 1.63 mm and GI holding hook on LT / HT poles, complete all as specified and directed by Engr-in-Charge.
Unbinding from insulators and restretching ACSR conductor of any size on LT / HT poles with and including binding with 2mm dia aluminium binding wire to insullators, complete all as specified and directed by Engr-in-Charge. Note : 1. The cost of binding wire is deemed to be included in quoted rates. 2. The distance between two poles for one single LT / HT conductor will be consider as one span.
Labour only for taking down / dismantling of old unserviceable insulators any type and any make from cross arms / pole of any size, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, pin type insulators, vitreous porcelain white, brown or green of 100 mm height and 65 mm dia, with and incl one galvanised MS spindle, two galvanised iron washers and one galvanised iron nut, suitable for 1100 volts grade, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, shackle type insulators, vitreous porcelain white, brown or green of size 75 mm height and 90 mm dia, with and incl GI strip, two galvanised iron washers and one galvanised iron nut, suitable for 1100 volts grade complete all as specified and directed by Engr-in-Charge.
S&F in replacement, loop type insulators, vitreous porcelain white, brown or green large size with over all dismensions 90x140mm and clearance of hole 25.5 mm complete all as specified and directed by Engr-in-Charge.
Trimming of tree branches around 3 metre of either of LT Overhead Line having any numbers of conductors and removing it from site at a distance not less than 100 metres, complete all as specified and directed by Engr in Charge.
M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
M&L stay assembly complete using stay rod of 16 mm dia complete with accessories as shown in electric plate No. 1 of SSR – 2009 Part –I complete all as specified and directed by Engr-in-Charge.
Labour only for dismantling of LT pole of any size & discription incl coping, foundation etc, complete all as specified and directed by Engr-in-Charge.
Supply and erection in vertical position steel tubular swaged pole type 410 SP- 31 (09 mtr long ) with Mild Steel base plate of size 30cmx30cmx6 mm thick continuously welded to pole , final taper plug ,bolts ,nuts and screws all as specified including factory painted with two coats of black bituminious paint internally throughout and externally for embedded position and two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide strip (total 5 Nos ) with black and yellow paint including numbering, complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge and comprising of following accessories/fittings :-
(a) MCCB 4 pole, 160 Amps,240/415 Volt, 50Hz, 10 KA= 01 Nos (I/C) (b) MCB SPN 63 Amps, 240 Volts - 04 Nos (O/G) Note : Unit rate quoted by the contractor here-in-before also includes for fixing and connecting of MCBs and installation of panel on suitable PCC foundation and PCC plat form incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 45cm(l)x30cm(w)x60cm(h) , dust and vermin proof, fabricated out of mild steel sheet not less than 3.15 mm thick, complete with openable shutters in front and rear having proper locking arrangement including including 04 Nos legs made out of angle iron of suitable size and height of each leg shall be grouted in PCC and aluminium bus bar of size 400 Amps capacity , Three phase and neutral bus bar , making hot and cold drilling holes to aluminium bus bar . Junction box shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and connecting all incomming and outgoing cables with suitable size of Aluminium lugs complete all as specified and as directed by Engineer-in-Charge.
Ms Salaria Builders (BID ID -3299227)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .