| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC FLAT NO 204 SAI ENCLAVE DIPATOLI NEAR KHELGAON CHOWK BARIATU RANCHI | RANCHI | ₹1.4 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC L.N.-185 DT-6.3.24
L.N.-175 DT-6.2.24 |
| 2 | L2₹1.4 Cr+₹9.8 L (7.61%)Rejected-Finance | ₹1.4 Cr+₹9.8 L (7.61%) | L2 | Rejected-Finance L.N.-175 DT-6.2.24 |
| 3 | L3₹1.4 Cr+₹12.5 L (9.69%)Rejected-Finance | ₹1.4 Cr+₹12.5 L (9.69%) | L3 | Rejected-Finance L.N.-175 DT-6.2.24 |
| 4 | L4₹1.5 Cr+₹18.3 L (14.2%)Rejected-Finance | ₹1.5 Cr+₹18.3 L (14.2%) | L4 | Rejected-Finance L.N.-175 DT-6.2.24 |
| 5 | L5₹1.6 Cr+₹34.6 L (26.8%)Rejected-Finance | ₹1.6 Cr+₹34.6 L (26.8%) | L5 | Rejected-Finance L.N.-175 DT-6.2.24 |
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
30 Nov 2023, 5:00 pmClosed
EXECUTIVE ENGINEER,MINOR IRRIGATION DIV.RANCHI
EXECUTIVE ENGINEER,MINOR IRRIGATION DIV.RANCHI
Residual work of Karanji M.I. Scheme, Block-Bero,Dist- Ranchi.
2023_WRD_77583_1
WRD/MID/RANCHI/F2-1/23-24
Open Tender
Civil Works
Percentage
RANCHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹4.0 L
Yes
10 Mar 2024
10 Nov 2023
2 Dec 2023
10 Nov 2023
30 Nov 2023
10 Nov 2023
Amount
PART-B NON-SCHEDULED ITEMS Solar Module Mounting (Galvanised Steel ) surface structure ( for 50 KW) having Hot deep galvanised of zinc thickness 80 micron and as per IS 4759 with C channel & anti theft with nut bolt of grade SS304, which should also withstand high wind velocity upto 150 km/hr. or as per MNRE.
50 KWP SPV module of 330 wP or higher rating, which must have specification as per IS 14286/ EC 61215. The module must have to qualify IS/IEC 61730 part-I & II (or having mechanical load test of 5400 Pa.) for safety purpose. Module to Module wattage mismatch in SPV array shall be +/-3% and to qualify IEC TS 62804:2015 for the detection of potential induced degradation and warrented for output wattage not less than 90% in 10 yrs. and 80% at the end of 25 Yrs as per MNRE.
SPV controller/ VFD integrated with GPRS, having MPPT, protection IP 65 or above as per MNRE to run 10 HP DC Solar pump.
Solar cable 4 Sq.mm used as per IS 694 or as per MNRE
Copper cable 25 Sq.mm used as per IS 694 or as per MNRE
Arrangment of lightening Arrestor excluding earthing as per MNRE for 50 Kw & 5 nos. 10 HP DC solar pump.
10 HP DC (PMSM/BLDC/SRM) Solar pump set of having performance with respect to Total head, Maximum Current, Capacity, Voltage Range etc as per MNRE guidelines.
Array junction box (IP 65 or above) as per MNRE for 50 KW SPV
Miscellaneous accessories for installation of 10 HP Solar Pump.
Supplying, installation and commissioning charge of module and structure for 50 KW.
Maintenance for at least 5 Years or as per MNRE guidelines for 50 KW SPV module & 5 nos. 10 HP solar pump with all accessories
18 % GST on Estimated Amount
1% Labour Cess
Maa Contract Pvt Ltd
M/S JAY GURUDEO ENTERPRISES
NAZ CONSTRUCTION
M/S RAAVI CONSTRUCTION
KIRANSONAM CONSTRUCTION PRIVATE LIMITED
ABHISHEK ANAND
Maa Contract Pvt Ltd
NAZ CONSTRUCTION
M/S RAAVI CONSTRUCTION
M/S Madan Kumar
KIRANSONAM CONSTRUCTION PRIVATE LIMITED
ABHISHEK ANAND
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .