Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹41.0 L Quoted ₹41.4 L | L1 | Accepted-AOC Lowest and accepted |
| 2 | L2₹43.3 L+₹2.0 L (4.75%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹43.3 L+₹2.0 L (4.75%) | L2 | Rejected-Finance L2 |
| 3 | L3₹49.2 L+₹7.8 L (18.9%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹49.2 L+₹7.8 L (18.9%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | - | - | Rejected-Technical Not Recommended for opening due to invalid DD uploaded. |
| 5 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | - | Rejected-Technical Not Recommended for opening due to scanned DD not uploaded. |
| Sl No | Description | Qty | Unit | sapana enterprises L3 | Shree Ayyappa Engineering L2 | M/s Mukesh Engineers L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking up/down under ground cable 11000 Volt grade of size 120 Sqmm, 3 core from trenches, ducts, floor, pipes and removing materials from site of work complete all as directed by Engineer-in- Charge.(Note: Excavation and earth work shall be measured separately) | 1,200 | RM | 100 ₹1,20,000 | 40 ₹48,000 Lowest | 70 ₹84,000 |
| 2.00 | Supply , laying & testing HT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty ) with stranded aluminium conductor 11000 volts (Earthed), grade of size 120 Sqmm 3 core all as specified and directed.
Make: Polycab/ KEI/ Grandley | 1,200 | RM | 2,500 ₹30,00,000 | 1,700 ₹20,40,000 Lowest | 1,800 ₹21,60,000 |
| 3.00 | Supply and fix cable jointing kit for 11 KV grade for indoor termination end Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 Sqmm to 185 sqmm all as specified and directed.
Make: 3M/ M Seal/ Raychem | 6 | Each | 10,000 ₹60,000 Lowest | 14,000 ₹84,000 | 10,000 ₹60,000 Lowest |
| 4.00 | Supply, fixing and testing cold shrinkable type, straight through cable jointing kit, outdoor type suitable for XLPE insulated cable, 120 Sqmm to 185 sqmm size 3 core, 11 KV, as fixed in repairs complete all as specified and directed.
Make: 3M/ M Seal/ Raychem | 5 | Each | 21,000 ₹1,05,000 Lowest | 23,000 ₹1,15,000 | 30,000 ₹1,50,000 |
| 5.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed | 298 | Cum | 900 ₹2,68,200 | 800 ₹2,38,400 | 200 ₹59,600 Lowest |
| 6.00 | Excavation in trenches in hard dense soil/ road cutting/ PCC not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed | 30 | Cum | 550 ₹16,500 | 500 ₹15,000 Lowest | 800 ₹24,000 |
| 7.00 | Supply and laying un-reinforced precast conctere cable cover,class HVP, type 2 with peak size of 450 X 180 X 40 mm.
Make: Mehtab tiles/ National tiles or equivelent | 6,200 | Each | 100 ₹6,20,000 | 150 ₹9,30,000 | 44 ₹2,72,800 Lowest |
| 8.00 | M & Lfor dry screened river bed sand cushioning 8cm before laying the cable and 15cm after laying the cable and further hand punned to form a uniform all as directed by Engr-in-Charge. | 89 | Cum | 1,150 ₹1,02,350 Lowest | 1,600 ₹1,42,400 | 1,500 ₹1,33,500 |
| 9.00 | Returning and filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm | 172 | Cum | 100 ₹17,200 | 120 ₹20,640 | 60 ₹10,320 Lowest |
| 10.00 | Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above Cum the starting point in rocks. | 126 | Cum | 100 ₹12,600 Lowest | 120 ₹15,120 | 300 ₹37,800 |
Tender Value
₹42.4 L
EMD Value
₹84,820
Closing Date
21 Jan 2026, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
ADDN/ ALTN AND DIVERSION OF HT UG CABLES 3 CORE X 120 SQMM FROM EKM TO WED SUBSTATION AND AYUDH VIHAR TO MRS SPDC SUBSTATION AT NAD TROMBAY UNDER GE (NW) MANKHURD
2025_MES_746772_1
8808/E8
Open Tender
Electrical and Maintenance Works
Works
273 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (NW) MANKHURD
₹84,820
15 Mar 2026
1 Jan 2026
23 Jan 2026
1 Jan 2026
21 Jan 2026
14 Jan 2026
Taking up/down under ground cable 11000 Volt grade of size 120 Sqmm, 3 core from trenches, ducts, floor, pipes and removing materials from site of work complete all as directed by Engineer-in- Charge.(Note: Excavation and earth work shall be measured separately)
Supply , laying & testing HT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty ) with stranded aluminium conductor 11000 volts (Earthed), grade of size 120 Sqmm 3 core all as specified and directed. Make: Polycab/ KEI/ Grandley
Supply and fix cable jointing kit for 11 KV grade for indoor termination end Cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 Sqmm to 185 sqmm all as specified and directed. Make: 3M/ M Seal/ Raychem
Supply, fixing and testing cold shrinkable type, straight through cable jointing kit, outdoor type suitable for XLPE insulated cable, 120 Sqmm to 185 sqmm size 3 core, 11 KV, as fixed in repairs complete all as specified and directed. Make: 3M/ M Seal/ Raychem
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed
Excavation in trenches in hard dense soil/ road cutting/ PCC not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide and getting out complete all as specified and directed
Supply and laying un-reinforced precast conctere cable cover,class HVP, type 2 with peak size of 450 X 180 X 40 mm. Make: Mehtab tiles/ National tiles or equivelent
M & Lfor dry screened river bed sand cushioning 8cm before laying the cable and 15cm after laying the cable and further hand punned to form a uniform all as directed by Engr-in-Charge.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above Cum the starting point in rocks.
M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete as specified and directed
S&F of HDPE type pipe, PN-10, 100 mm dia for laying in ground, road crossing etc for cable protection including necessary fittings for wall and ducting with required clamps and supports, etc. all as directed by Engineer in Charge. Note: Required Clamps and supports (PCC) shall be fixed on wall with distance 1.00 RM as directed by Engr- in- Charge. Make: FINOLEX/ TIRUPATI/ SUPREME/ DUPLON (RELIANCE)
S & F cable route indicator made out of 50x50x6mm angle iron, 150mm long embedded in PCC block of suitable size with the letter 'HT CABLE' suitable inscribed on Cl circular plate plate 8mm thick, 100mm dia complete as specified and directed.
Renewal of broken/wornout earth pit including M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) Product Model: ASEEL 19 CP, 3 meter long (Copper Plated) – 100 microns . Fast Electrode, Model FE 80 mm 3 mtr (Pure Copper Single Pipe), Outer Dia is 80 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Fast Electrode Earth Enhancement Compound, Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size : 2 Bags of 25 kilograms, Recommended for normal soil conditions. Confirms to IS : 3043 – 1987. (c) Installation of earthing with bore well machine complete for bore exceeding upto 4.5 meter below ground level complete all as specified and directed by Engr-in-Charge.
Earth continuity conductor or main earthing lead of size 20x3mm copper strip fixed to wall on battenor recess or chases or buried inground or drawn in conduit/pipe orfixed to poles or any other indicatedsituation for loop earthing etc. as required
S&F HT rubber insulsted mat suitable for 11KV panel 3 mm thickness Claas'B' having fire retardant, insulation water resistance of size 1m X 10m X 3mm confirming ISI 15652:2006
S&F Self-amalgamating high voltage electrical insulation tape suitable for 11 KV AC supply of size not less than 50 mm wide x 0.8mm thick x10 Mtrs (EPR Rubber) having property of Moisture seal for all water- proofing needs for insulating protection of bus bars, cable lugs, terminations, transformers other power distribution equipment also incl corona ozone resistance and UV resistance confirming IS 7809:1 (1975) Make: 3M/ Scapa or equivalent
S&F CTC solution for for removing carbon on electrical equiments, each bottle not less than 400 ml solution
Supply and install in repairs AFO (Auto fire off) fire extinguisher ball 150 mm dia (standard orange) with stand complete all as specified and directed.
Supply HT Earth discharge rod suitable for 11 KV equipped with FRP/rubber insulator to increase creepage distance, Excellence dielectric strength, Fiberglass tube manufactured from high quality epoxy resin including canvas bag confiming ISI standard
S&F HT rubber gloves suitable for 11 KV madeup of Bi-polymer coating is a blend that combines the best properties of nitrile and PU (polyurethane) having meet or exceed ASTM D120 and IEC EN60903 Standards Make: Honeywell/ The top gloves/ Or equivelent
S&F 1st Aid box with including all essential 1st aid medicine (minimum 32 medicine) of size 5D x 20W x 10H Centimeters, 4 Partition for medicines organize with lock Inlcuding feature of wall mounting box made from galvanize Metal with 7 Way Processed Powder Coating complete all as specified and directed.
S&F high power torch strong beam suitable for long range, single high power LED with 2 mode light switch having USB type charging port. Operating on 3.7 V DC, battery supply >4000 mAh Make: Phillips/ Eveready/ or equivelent to Phillips
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_836229.xls
BOQ • 0.60 MB
Tenderdocu8808.pdf
Tender Documents • 1.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .