Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 254 MG ROAD LAMBA LANE JUNGLIGHAT PORT BLAIR SOUTH ANDAMAN ANDAMAN AND NICOBAR ISLANDS 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.5 L+₹50,000 (3.34%)Rejected-Finance | L2 | Rejected-Finance Rejected due to L2 | |
| 3 | L3₹17.5 L+₹2.5 L (16.6%)Rejected-Finance | L3 | Rejected-Finance Rejected due to L3 | |
| 4 | L4₹22.4 L+₹7.5 L (49.7%)Rejected-Finance SUBAN BAZAAR DIGLIPUR NORTH ANDAMAN 744202 | DIGLIPUR | NORTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744202 | L4 | Rejected-Finance Rejected due to L4 |
| Sl No | Description | Qty | Unit | Kakolil Trade Agencies L1 | AMR TRADERS L2 | MOHAMMED SAFIQUE L4 | OPS Associates L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation and testing of retrofitting of emission control device (RECD) on existing 200 KVA DG set with complete fittings and attachments as per CPCB norms. The exhaust of DG set post fitment the exhaust limits are as follows :-
(a) Nox+HC < 4.0
(b) CO < 3.5
(c) PM < 0.2
(d) Smoke limit (light absorption co-efficient, m1)< 0.7
Job to be carried out as per the satisfaction of engineeer in charge. Make of RECD to be procured from one of the five central pollution board (CPCB) recognised labs. | 3 | Each Job | 4,11,000 ₹12,33,000 Lowest | 4,27,000 ₹12,81,000 | 6,15,000 ₹18,45,000 | 4,49,500 ₹13,48,500 |
| 2.00 | Supply , installation and testing of retrofitting of emission control device (RECD) on existing 100 KVA DG set with complete fittings and attachments as per CPCB norms. The exhaust of DG set post fitment the exhaust limits are as follows :-
(a) Nox+HC < 4.0
(b) CO < 3.5
(c) PM < 0.2
(d) Smoke limit (light absorption co-efficient, m1)< 0.7
Job to be carried out as per the satisfaction of engineeer in charge. Make of RECD to be procured from one of the five central pollution board (CPCB) recognised labs. | 1 | Each Job | 2,66,000 ₹2,66,000 Lowest | 2,68,000 ₹2,68,000 | 3,99,000 ₹3,99,000 | 3,99,500 ₹3,99,500 |
| 2.10Note for item No 1 & 2: The quotated rates includes the following:- (i) Design, supply and installation of the MS pipe ducting from the DG exhaust to the inlet of RECD machine, in the line with the dimensions provided in the technical specifications. (ii) Water connection piping near the water cleaning mechanism for periodic refilling of the water tank. (iii) Construction and provision of a leveled flat surface near the DG sets for proper placement of the RECD system. (iv) Electrical socket installation with 2.5 sqmm near RECD system to ensure reliable power connectivity. (v) All other necessary civiel/electrical work for smooth functioning of RECD system. | |||||||
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
4 Feb 2026, 6:00 pmClosed
Garrison Engineer (South) Diglipur
Garrison Engineer (South) Military Engineer Services RK Gram, Diglipur North Andaman - 744 202
PROVISION OF RETROFITTING EMISSION CONTROL DEVICE (RECD) UNDER GE (SOUTH) DIGLIPUR
2026_MES_748570_1
8191/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
DIGLIPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (South)
₹32,000
Yes
3 Mar 2026
14 Jan 2026
9 Feb 2026
14 Jan 2026
4 Feb 2026
28 Jan 2026
15 Jan 2026 - 22 Jan 2026
Supply, installation and testing of retrofitting of emission control device (RECD) on existing 200 KVA DG set with complete fittings and attachments as per CPCB norms. The exhaust of DG set post fitment the exhaust limits are as follows :- (a) Nox+HC < 4.0 (b) CO < 3.5 (c) PM < 0.2 (d) Smoke limit (light absorption co-efficient, m1)< 0.7 Job to be carried out as per the satisfaction of engineeer in charge. Make of RECD to be procured from one of the five central pollution board (CPCB) recognised labs.
Supply , installation and testing of retrofitting of emission control device (RECD) on existing 100 KVA DG set with complete fittings and attachments as per CPCB norms. The exhaust of DG set post fitment the exhaust limits are as follows :- (a) Nox+HC < 4.0 (b) CO < 3.5 (c) PM < 0.2 (d) Smoke limit (light absorption co-efficient, m1)< 0.7 Job to be carried out as per the satisfaction of engineeer in charge. Make of RECD to be procured from one of the five central pollution board (CPCB) recognised labs.
Note for item No 1 & 2: The quotated rates includes the following:- (i) Design, supply and installation of the MS pipe ducting from the DG exhaust to the inlet of RECD machine, in the line with the dimensions provided in the technical specifications. (ii) Water connection piping near the water cleaning mechanism for periodic refilling of the water tank. (iii) Construction and provision of a leveled flat surface near the DG sets for proper placement of the RECD system. (iv) Electrical socket installation with 2.5 sqmm near RECD system to ensure reliable power connectivity. (v) All other necessary civiel/electrical work for smooth functioning of RECD system.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.69 MB
BOQ_838317.xls
BOQ • 0.39 MB
8191TENDER.pdf
Tender Documents • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .