Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹39.7 L+₹2.3 L (6.04%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹40.0 L+₹2.5 L (6.77%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹41.7 L+₹4.2 L (11.3%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 5 | L5₹42.3 L+₹4.9 L (13.0%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
Refer Docs
EMD Value
₹79,600
Closing Date
10 Mar 2021, 6:00 pmClosed
CWE AF Secunderabad
CWE AF Secunderabad Bowenpally Post Secunderabad 500 011
PROVISION OF VACCUM CIRCUIT BREAKER AT CAW AREA PROVN OF TRANSFORMER AT OAC AF STATION BEGUMPET AND PROVN OF TRANSFORMER AND CONNECTED WORKS AT AFS BEGUMPET UNDER GE AF HAKIMPET
2021_MES_419264_1
84646/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF Hakimpet
As Per NIT
8 documents required · 8 mandatory
₹500
GE AF Hakimpet
₹79,600
9 Apr 2021
5 Feb 2021
12 Mar 2021
5 Feb 2021
10 Mar 2021
24 Feb 2021
5 Feb 2021 - 15 Feb 2021
Amount
Supply, installation, connecting electrically & commissioning HT 11 KV. 3 phase 50 Hz totally enclosed metal clad switchgear complete with Vacuum Circuit Breaker having rupturing capacity minimum 250 MVA, overload and earth fault protection, ammeter, voltmeter and of rating minimum 630 Amp 25 / 26 KA / 1 sec outdoor type with inbuilt power pack Horizontal Draw out/Horizontal Isolation VCB, Conforms to IS 2516-1980. IEC-62271-100, IEC-· 60298 & IEC-60694 with the following accessories:‐
(a) 11 KV 25/26 KA/ 1 sec, 630 Amps Breaker , Spring Charging Motor, 230V AC,Tripping Coil‐ 24 VDC, Closing Coil‐ 24 VDC, Aux. Contacts: 12 NO + 12 NC, Limit Switch for Test Position,Limit Switch for Service Position,With Mechanical ON/OFF Indication and Mechanical ON/OFF Emergency Push Button, Inbuilt Antipumping Feature.of Qty -01 Model: EASY PACT/3AHO104 , Make :- Schneider / Siemens or Equivant in ABB
(b) POTENTIAL TRANSFORMER :- 3 No Single Phase Fixed type Epoxy Cast Resin Type having, Ratio: 11KV/√3/110V/√3, and Core 1: 50 VA, 3P/50 VA, Class 1.0. of Qty-03 Make:- Pragati/Jamini/ECS/HUPHEN
(c ) CURRENT TRANSFORMER : -11 KV:- Single Phase Epoxy Cast Resin Current Transformer :‐Rated Voltage: 11KV, BIL=12/28/75 KVp,Freq: 50Hz, Isc: 25KA/1 sec/ 26KA/3 sec. CTR: 50/1-1 A,Core1: 15 VA, Class 1.0, Core2: 15VA, Class 5P10 of Qty- 03 Make :- Pragati/Jamini/ECS/HUPHEN
(d) PROTECTION (1) MICOM P111A Relay with following protection (50,50N,51,51N,86,95) or 3 OC/1 EF-Relay, 7SR- 1003 with RS 485 Communication Make Schneider/Siemens (2) Master Trip Relay Model No : VAJH 13 Make ALSTOM/Siemens (3) C 3 Element Auxiliary Relay Model No: VAA33 Make :- ALSTOM
(f) CONTROL SECTION Breaker Control Switch, Trip‐Neutral‐Close, Spring return to Neutral, Pistol Grip , Breaker LED lamps. Breaker ON‐24 V DC,Breaker OFF‐24 V DC, ,Trip Circuit Healthy‐24 V DC, CB in Test Position‐24 VDC, CB in Service Position‐24 V DC, Indicating Lamps:- R,Y,B PHASE EACH WITH 110 V AC , Power Pack 230 AC to 24 DC with 7 AH battery back-up, Panel Space Heater, 100W, 230V AC. With Thermostat Suitable for 230V AC Setting, Surge Arrester 9 KV 10 KA
(g) Heater Control switch
(h) Cubicle illumination switch
(j) Panel illumination 9 W,230 VAC
(k) Main Bus Bar 630 A, Material CU.With suitable heat shrinkable sleeves incl Bushings
(l) Safety Shutters, Wiring +Labour, 11 KV Bus Support Insulators 6 Nos, Bus Bar Sleeve PVC
(m) Cubicle shall be consisted of 3.15 mm CRCA Sheet for outer shell, minimum 1 mm for partitions and load bearing parts. It will be provided with the Cable termination incoming and outgoing from bottom. Degree of protection, IP-55
(n) The complete fabrication of Cubicle and control wiring shall be carried out by either OEMs or auth dealers/ channel partners of OEMs all as specified and directed by Engr-in- Charge. Make :- Schneider / Crompton Greaves / Siemen / ABB
Supply laying, jointing and testing cable HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm 3 core complete all as specified and as directed.
Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of 95 sqmm to 185 sqmm complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below with top edge of the earth plate not less than 1.5 mtr below normal ground level , earth plate shall be connected tp & including the galvanized iron strip 32 mm X 6 mm by (up to 7.5 mtr) welding and brought upto 1.0 mtr above plinth protection, including provision of suitable size of light grade GI pipe for protection of galvanized iron strip up to plinth and further connecting with GI wire distribution boards, including excavation, earth work, Charcoal & salt, 30 cms layer of two parts of bentonite mixed with one part BC/loomy/garden soil and four parts of water all around the charcoal , salt mixture all as dircted, PCC chamber , RCC cover slab, watering pipe 20 mm dia bore med grade , wire net, funnel etc. & testing on completion all as specified in plate No 3 of SSR Pt I, complete all as specified and as directed. Note: - GI Pipe for earth lead protection will measured and paid separately under relevant items of BOQ.
Material and labour for GI tubing light grade 40 mm bore with fittings in replacement laid for protection of cable under road crossing fixed to walls or pole and earth lead protection pipe etc complete all as specified and as directed.
Excavation in post holes or similar holes, each not exceeding 0.5 Cum, getting out in Hard / Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not .exc 50 mtr & making good surface complete all as specified and as directed.
M & L for Plain Cement Concrete 1:2:4 Type B-2 (using 40 mm graded granite stone aggregate) in walls or retaining walls, any thickness, size or shape including pillasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed.
S&F of Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
Supply only chain link MS galvanised fencing any size or type not exc 4 kg / sqm complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standars, rails, straining bolts etc including provision of building wire complete all as specified and as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and 'scraved the other to be fitted with washers and one hexagonal or square nut not exc 5 cm long and dia 5 to 10 mm complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chrome primer complete all as specified and as directed.
M&L for hard core of gauge 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, etc., and getting out in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr in wide and exceeding beyond 1.5 mtr in depth and upto 3.0 mtr for fixing / laying pole and getting out in the soft / loose soil complete all as specified and as directed.
M & L for Plain Cement Concrete 1:4:8 Type D-2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
Supply , installed, Testing and commissioning Transformer step down , Copper wounded, Outdoor Type complete with standard fittings HT 11 KV/433 volts (at no load) 3 phase 4 wire, 50 Hz, 315 KVA capacity core type double copper wound, oil immersed. naturally cooled,. Oil naturally Air natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with victor group DYn-11 with natural brought out on secondary side (LV side) and having tapping at +- 2.5% & +- 5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temp rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temperature of 40 degree Celsius. including PCC Foundation suitable size. Note:- The Transformer shall be IS- 1180 marked and shall comprises of the following :-
(a) Three Nos porcelain bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers
(b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers with cable glands
(c ) Oil conservator with filter type drain valve and oil level gauge
(d) De- hydrating breather with first type fill of dehydrating agent (Silica Gel)
(e) Explosive vent, thermometer pocket on tank cover .Oil level gauge , Oil drain filter valve, Lifting lugs, Oil filling hole with cap , plug with connection plate complete. Air release valve plug and four nos plain solid cast steel detachable rollers.
(f) One no 100 mm dia dial type thermometer vapour pressure type , having range 0-120 Degree Celsius with metal guard having maximum perimeter temperature reading indicator with re- setting devices
(g) Two earthing terminal on tank cover to facilitate fixing of 32 X 6 mm GI iron earth strip for earthing of body
(h) Rating plate and terminal marking plate
(i) Extra bushing for neutral, out side the cable box for providing independent set of earthing for neutral
(j) First filling of new and unused transformer oil, IS- 335 marked (Make savita / Power link) filtered and tested
(k) Cost of PCC plinth for mounting Transformer is deemed to be included in the quoted rate. PCC plinth shall be provided all as recommended by Transformer manufacturers / Engineer-in-Charge and approved by GE.
Supply & Laying in trenches or passing through pipe / fixed to pole / wall LT XPLE insulated armoured heavy duty electric cable with alluminium conductor , 1100 volts grade , cross sectional area 120 sqmm X 3.5 core complete all as specified and as directed.
Supply & Laying in trenches or passing through pipe / fixed to pole/ wall LT XPLE insulated armoured heavy duty electric cable with alluminium conductor , 1100 volt grade , cross sectional area 95 sqmm X 3.5 core complete all as specified and as directed.
Excavation in trenches in hard / dense soil not exc 1.5 mtr in width and not. exc 1.5 mtr in depth and getting out for laying of cables complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and as directed. (NOTE :- Only punned thickness will be measured and paid)
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed.
Supply, installation, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted of size 1200 mm X 1000 mm X 450 mm suitable for 415 Volts 3 phase 4 wire system 50 Hz supply having aluminum bus bar 600 Amps for phases and neutral, installed on porcelain / epoxy insulator. The panel shall be dust proof, vermin proof (IP55) powder coated with fabricated 3.15 mm thick skelton with angle iron / flat iron frame work and sheet self moulded type and 50 x 50 x 6 mm angle iron frame front and rear opening with double shutter and locking arrangement with 50 mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified and as directed.
The scope of work includes provision of housing the following accessories:- Incoming : - (i) MCCB 400 Amp with , 4 Pole,36KA - 01 No. (ii) Volt meter 0 to 500 Volts, Square flush pattern, digital type – 01 No (iii) Amp meter square flush pattern 0 to 400 Amps digital type -01 No. (iv) Indicating lamp LED type one set in incoming phases. (v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 Volt grade IS 694 marked of appropriate gauge including all copper lugs Outgoing ways :- For 04 Nos outgoing cables (i) MCCB 200 Amp, 4 Pole,36KA 415 volts - 03 Nos. (ii) MCB 40 Amp, SPN 415 volts - 01 No.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or chases or buried in ground or drawn in conduit / pipe or fixed to wall or any other indicated situation for loop earthing etc. as required 4.0 mm dia galvanised iron wire complete all as specified and as directed.
Supply, errection, testing and commissioning of Transformer outdoor type capacity 160 KVA, 3 phase, 50 Hz double wound with copper winding in mild steel tank as per IS -1180, 11KV/433 volts with tapping arrangement to HT side to vary secondary voltage (+) 5 % to (-)5% in step of 2.5% on HV windings of clrcuit, vector group DYN-11, mounted on suitable PCC Plinth, inltial filling of transformer oil and making connection from 11 KV HT bushing to epoxy cable box including all undermentioned accessories complete all as specified and as directed all as per manufacturer's instruction complete all as specified and as directed for the following :- (i) HT side terminal box - 01 No. with suitable bushings - 04 Nos (ii) LT side terminal box - 01 No with suitable bushings - 04 Nos (iii) Lifting lugs - 04 Nos (iv) Oil conservator tank with drain plug - 01 No (v) Silica Gel breather - 01 No (vi) Drain valve with plug - No (vii) Explosion vent - 1 No (viii) Temperature guage with for oil & winding - 1 No (ix) Earthing terminals - 2 Nos (x) Air release plug - 1 No (xi) Offioad tap changer with locking facility - 1 No (xii) Oil level guage - 1 No (xiii) Rating & connection diagram plate - 1 No
(i) HT side terminal box - 01 No. with suitable bushings - 04 Nos (ii) LT side terminal box - 01 No with suitable bushings - 04 Nos (iii) Lifting lugs - 04 Nos (iv) Oil conservator tank with drain plug - 01 No (v) Silica Gel breather - 01 No (vi) Drain valve with plug - No (vii) Explosion vent - 1 No (viii) Temperature guage with for oil & winding - 1 No (ix) Earthing terminals - 2 Nos (x) Air release plug - 1 No (xi) Offioad tap changer with locking facility - 1 No (xii) Oil level guage - 1 No (xiii) Rating & connection diagram plate - 1 No
Note :- Cost of PCC Plinth for mounting Transformer is deemed to be included in quoted rate. PCC plinth shall be all as recommended by Transformer manufacturer / Engineer-in-Charge and approved by GE.
S&F Steel Tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410SP-55 (11 mtr long) inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
S&F Anti- climbing device, spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
S&F Cross arms, bracing supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilled holes for bolts in any shape or size as indicated or as directed inclusive of one primer coat or red oxide, one under coat and finishing coat of aluminium paint complete all as specified and as directed.
S&F Danger Notice board of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts & nuts of approved size for HT 25 X 20 Cm size complete all as specified and as directed.
S&F Lightening arrestor, expulsion type complete with all fittings, transmission class, 10 KA, maximum discharge capacity 65 Kilo Amps suitable for 11000 volts complete all as specified and as directed.
S&F Horizontal Air Break Switch, Gang operated triple pole mechanically operated, mounted on insulators and steel frames with operating mechanism worked from ground level 06 insulators for current rating upto 400 Amps, 11000 volts grade complete all as specified and as directed.
S&F Horizontal Air Break Switch, Gang operated triple pole mechanically operated, mounted on insulators and steel frames with operating mechanism worked from ground level 06 insulators for current rating upto 200 Amps, 11000 volts grade complete all as specified and as directed.
S&F Drop out fuse unit single pole suitable for 11000 Volts grade upto 50 Amps including 02 suitable insulators complete all as specified and as directed.
Supply, laying & testing cable HT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts (Earthed) grade, of size 3 core 120 sq mm complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm complete all as specified and as directed.
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 400 Amps capacity aluminium bus bar, Outdoor type, 3.15 mm thick CRCA sheet with inspection doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40 mm thick including internal wiring with PVC insulated copper cable, grouted in ground using PCC complete with the following accessories, duly pre-treated and powder coated finish including for the following accessaries :- (a) MCCB, 4 pole 250A, 25 KA- 01 No (Thermal magnetic release, Adjustable type) with rotary switch attachment INCOMING (b) MCCB, 3 pole 100A, 25 KA- 01 No (Thermal magnetic release, Adjustable type). OUT GOING (c) MCCB, 3 pole 80A, 25 KA- 02 No (Thermal magnetic release, Adjustable type). OUT GOING (d) MCCB, 3 pole 63A, 25 KA- 02 Nos (Thermal magnetic release, Adjustable type).OUT GOING (e) Only space provision for mounting one 3 pole MCCB (f) Digital display VAF Panel meter- 01 No. (g) LED Indicator RYB - 01 Set of 3
Supply, laying and testing cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and as directed.
Supply and laying un-reinforced pre-cast concrete cable covers, class HV, Type 1, flat, size 300 mmx l80 mm x 40 mm for HT 11 KV cable protection complete all as specified and as directed.
Supply and laying un-reinforced pre-cast concrete cable covers, Class LV, Type I, flat, size 250 mm x 150 mm x 40 mm for LT cable protection complete all as specified and as directed.
S&F Galvanised iron earth strip 32 x 6 mm earth continuity conductor as main earthing lead fixed to equipment etc as required complete all as specified and as directed.
S&F Aluminium conductor steel reinforced (ACSR) including provision of coloured PVC sleaves for phase identification complete all as specified and as directed.
S & F disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball & socket type, two-in-series, white, brown or green with tension clamps for conductors working pressure 11000 volts, grade for single disc assembly complete all as specified and as directed.
S & F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
M&L for Plain cement concrete type C-1, PCC 1:3:6 using 20 mm graded stone aggregate as in coping and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and as directed.
Supply & spreading / loose filling, stone aggregate of size 40 to 65 mm, not exceeding 15 cm bed depth in sub station around the transformer, over the M sand complete all as specified and as directed.
M&L for Sand filling with M-sand as screed bed under stone aggreagate and consolidation complete in sub station complete all as specified and as directed.
S&F Galvanised iron tubing, light grade with all fittings fixed complete to walls, poles, ceilings or laid in floors / trenches / road crossings for the protection of cables for the following sizes complete all as specified and as directed :-
(a) 50 mm bore
(b) 80 mm bore
(c) 100 mm bore
OM SAI POWER SYSTEMS
DURGAI ELECTRICALS
Srinivash Engineers
Saiansh Associates
POWER CONSTRUCTION COMPANY
STANDARD AGENCIES
VBK ELECTRICALS AND AGENCIES PRIVATE LIMITED
general electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .