I) Improvement to personnel department staff halls,conference hall,officers chamber and washrooms at Rail soudha Hubballi II) Hubballi Division:- GDG - HG section: Construction ofLimited Height Subway in lieu of LC No.112 KM 247/1-2 in between IDR-LHN station respectivelv.
05UBL2026-27-02
05UBL2026-27-02
Open
6 Months
Dharwad, Karnataka
₹0
₹52,800
3 Jul 2026
3 Jul 2026
20 Jul 2026
01-Schedule-A Chapter-02
02-Schedule-A,Chapter-06
03-Schedule-A, Chapter-07
04-Schedule-A, Chapter12
05-Schedule-A,Chapter-15
06-Schedule-A, Chapter-16
07-Schedule-A,Chapter-21
08-Schedule-A, Chapter-22
Item Breakup - 01-Schedule-A Chapter-02
4.00 17320.00 latest specification/ drawing. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
of foundation and erection of Apparatus Case Half size as per Drg, No.SG/SWR/056, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this item). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor] Total 130732.00
Item Breakup - 02-Schedule-A,Chapter-06
1000.00 except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this item).
1000.00 width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
of Metre Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item).
300.00 capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/ Reservation office / Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor)
48.00 thick as per latest specification.
48.00 for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 97538.00 Density Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 with Amd 3.0 or latest
1.00 14607.00 the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylone rope through it at different places as per direction of engineer incharge or site engineer
20.00 DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.
20.00 300mmX300mm, casting of Concrete foundation of size 300mmX500mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing.
4.00 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor]. Total 382857.00
Item Breakup - 03-Schedule-A, Chapter-07
1.00 110955.00 armoured PIJF underground telephone cable as per RDSO Spn.no. IRS/TC-41-97 or latest.
50.00 copper conductor 35 Sq.mm as per RDSO specification IRS.S 76/89 or latest Total 136055.00
Item Breakup - 04-Schedule-A, Chapter12
2.00 33324.00 input voltage 160V AC - 280 V AC, output voltage 230V AC, Operating Freq 47-63 Hz with back up time 30 minutes (APC, Emerson or similar make). Total 66648.00
Item Breakup - 05-Schedule-A,Chapter-15
Installation, Commissioning of Copper Plate Earthing System complete as per Drg.No.SG/SWR/058 with provision of (i) Copper plate 300 mm X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up with charcoal 10 kg & salt 25 kg in alternate layers up to 2 ft from bottom, (iii) Water funnel on Perforated GI pipe of length 4.5 ft., (iv) Cast Iron top plate 12 x 12 (v) Drawing of copper - earth from earth to location with 25 mm x 3 mm copper strip for termination (All miscellaneous materials to be supplied by the contractor). Total 93292.00
Item Breakup - 06-Schedule-A, Chapter-16
1800.00 on PVC pipe / capping casing, or cable trays, ladder, shelter etc. as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe, outdoor cables if required to be clamped on wall /floor etc. Total 7200.00
Item Breakup - 07-Schedule-A,Chapter-21
6.00 conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 or latest for quad cable.
6.00 type complete for 6 quad cables. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 covered in the supply portion has to be used for this purpose.] The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing
4.00 the fiber and provision of joint chamber of 1.2 mtr dia, 60 Cm height and 50 mm thickness with two-piece top cover and bottom cover. with holes for drainage and cable entry (The reinforcement drawing enclosed). This includes backfilling and ramming of the trench after placing the joint closure and cable loop in the chamber without causing any damage to the same and consolidation of soil as well as disposal of soil as per plan and as advised by RailTel Representative.
4.00 chambers with dry sand mixed with ant termite chemical as required in specification up to 400mm height and the cover is refixed in position.
20.00 ohms or 470:600 ohms or 470:470 ohms as per RDSO spec No. IRS-TC-76-2021 or latest. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
200.00 STP/UTP cable
Item Breakup - 08-Schedule-A, Chapter-22
1500.00 road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation more than 100 Kms. Total 24000.00
Item Breakup - 09-Schedule-B
Rectification and re-splicing of existing of Numbers mid section OFC joints. This includes supply and provision of joint repair kit & sleeves
Supply and installation of 48 fibre Joint Numbers enclosure and Splicing of armoured optical fibre cable (48 fiber) conforming to RDSO spec.RDSO/SPN/TC/68/2014 rev2.1or latest Inspection : RDSO
Supply of XLR male-female connector for Pair microphone cable Make: MX or similar or better ( Inspection : Consignee )
Supply, Commissioning of Flush mount digital discussion conference chairman unit, chairman of the unit has the priority to speak, control key can start the system from remind to attend the researchers note that permanent can be set to terminate or suspend, terminate all speak on behalf of the unit of a state. Chairman in the system unit quantity not restricted, and may be placed on a loop in any position, microphone embedded installation. Using a new numeric controlled design. Microphone have to speak a single bond and Lamp, can speakstraight control / instructions single directional microphones high sensitivity with the function of preventing gas explosion sound. Frequency Response 40- 16KHz, Sensitivity-40dB ± 2dB, Reference sound receiving distance 20-120cm. Microphone should have indications for power and mike activation, as per technical specification and should be compatible for integration with video Conferencing Codec System Make:Bosch ,Heinrich, Shure ,Sennheiser or similar or better. Inspection : consignee HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply, Commissioning of microphone with embedded installation. Using a new Numeric controlled design. Microphone have to speak a single bond and Lamp, can speak straight control/instructions single directional microphones high sensitivity with the function of preventing gas explosion sound. Frequency Response 40- 16KHz, Sensitivity-40dB ± 2dB , Reference sound receiving distance 20 120cm. Microphone should have indications for power and mike activation, as per technical specification,and should be compatible for integration with video Conferencing Codec System Make: Bosch ,Heinrich, Shure ,Sennheiser or similar or better.Inspection : consignee
Supply, commissioning of Control Unit of make BOSCH ,Heinrich, Shure ,Sennheiser or better (Plug-and-play functionality for quick and easy connection of up to 80 Discussion Devices Intuitive web browser interface control for advanced configuration and control Builtin MP3 recorder with internal memory and USB recording Builtin Digital Acoustic Feedback Suppression (DAFS) for ensuring superior speech intelligibility On- board support for automatic HD camera control).Inspection : consignee
Supply and installation of Amplifier 500 watt Numbers Ahuja with builin digital player. Make-Ahuja (UBA 500 DP) or similar. DigitalPlayer-MP3 Player with USB, SD,MMC Card Reader & Bluetooth,Make: UBA-500DP Ahuja or better (Inspection Clause:Consignee)
Supply and installation of Allen and Heath Numbers ZED 10 mixer Inspection : consignee
Supply and Installation Of Conference Metre Multicore Cable for Loop in Loop Out.( Inspection :Consignee )
Supply and installation of Processor similar Numbers to make EV Model DC ONE similar or better ( Inspection : Consignee )
Supply and installation of 5"+1.5" Coaxial Numbers Ceiling speaker with ABS cover, 30W,100v, cutout 185mm, ABS baffle & back cover, metalgrille. The Speaker shall have Max SPL> 102 dB, Frequency Response 90- 20KHZ. The Speaker shall have Multiline tanning as per site requirement of make Bosch or better (Inspection : Consignee )
Supply and installation of Pop up Box with Numbers HDMI, LAN, power point with installation accessories ( Inspection : Consignee )
Installation, testing & commissioning of Job conference system items (including supply of all accessories like extension lead length as per site requirement, connecting cables, microphone cables, speaker cables, connectors etc & required civil work for under floor wiring, if any) etc. As per instructionsby consignee HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
"Supply of 24U Rack specification given Numbers below. 1.Depth of the Rack (mm)-up to 1000.2.Mount Type -free standing.3Secure Locks Available. 4.Support cable entry from top or bottom-yes 5.Number of Rack trays - 1 g.Number of Fan for Heat dissipation (nos)-4.7.PDU Power strips-available. 8.Type of glassused in front door transparent toughened glass etc make Valrack similar or better.Inspection : consignee"
"Supply of 1X8 HDMI Splitters/HDMI Numbers Distribution Amplifier supported upto 4KUHD, Make Impression /Kanex Pro Model :-W/HDCP2.2 /Bestnet Model: BNHDMI- 108SP-V1.4 /Primesol or Similar.Inspection : consignee"
Supply of HDMI 8x8 Switcher Cable Length Numbers 10 meter, Type of Switcher - Fixed, Switching Speed - 200 NS max.,110 Watt, Impedance - 100 Ohm, Video Bandwidth - 600MHz/18Gbps, Automatically Scan Sources Inputs via LED,Max. Transmission - 5 NS +/- 1 NS, Max. Distance - 15 Mtr, Backplane Data Rate Gbps - 12.5, 100-240 VAC, 50-60 Hz, 1.0 A.Inspection : consignee
Supply of 4K support Optical HDMI Cable of Numbers 20 Meter length as per TS-A4. (Warranty Period : Upto 30 months from the date of delivery.) Inspection : consignee
Supply Television Tv 65 Inch LED . Warranty Period: 30 month(s) from the date of Supply Firm's Offer: Make/Brand: SONY K-65S25M2.or similar or better. Inspection : consignee
Supply of wired Cardioid Microphone of Numbers Make: Sennheiser e835-S or similar or better.Inspection : consignee
Supply and installation of Sennheiser Numbers wireless supercardiod microphone similar Sennheiser XSW 2-865 or better .Inspection : consignee
Supply of SIP Based Medium IP Phone with Numbers 240X120 Pixel or better Graphical LCDwith Backlight, Minimum 8 No of One Touch line key as per Specification. Inspection RITES
Supply of SIP Based Video Phones 7 Numbers "Capacitive Adjustable Touch Screen,LCD screen, 720p 30 HD video should run on latest Android along with POE injector or better as per specification. Inspection RITES
Supply anda installation of FXS Gateway 48 Numbers Ports with license, Provides 48 analog FXS ports expandable up to 96,Supports 4 ports Ethernet switch with routing capability, Communicate with the multiple IMS/ soft switch at the same time, Supports various protocols like SIP V2.0, IMS/3GPP, SDP, RTP/ RTCP, MGCP & H.248. The FXS Gateway should be connected with the existing exchange at UBL.Inspection : consignee
Supply and installation of L2 8 port Gigabit Numbers Managed Network POE Switch with 2 SFP ports, Uplink Power Budget 150W Rack, including SM-SFP Module with distance minimum 20 KM, Wave length: TX-1310nm, RX1550nm, 1.25Gbpsspeed. Accepted Make:- DLINK or Netgear. similar or better and should be listed in trusted telecom portal Inspection : RDSO HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply Installation &Commissioning of Numbers Layer 2 Manageable, 24 Port POE+, 24 GE10/100 /1000 BaseX Ethernet port with POE+ support and 4x1GE SFP Port for uplink with 4 no of1GE BX SM SFP modules loaded, with all accessories per RDSO/SPN/TC/65/2021, Rev.6.0 with Amendment No. 1,2&3 o rlatest. and should be listed in trusted telecom portal Inspection :RDSO
Supply of On line 3 KVA UPS with batteries Numbers backup for 60 Minutes, input power single phase 160V 260V sine wave 50 HZ output power single phase 230 Volt, +/-1%sine wave 50 Hz, Onsite OEM warranty 3 Years (Battery & UPS Both) with supply & Installation or any higher specification. Make - Microtek, Luminous, Numeric, APC (Warranty Period : Up to 36 Month from the date of Supply.) Inspection : consignee
Supply of RJ-45 I/O concealed type of Numbers reputed make as crabtre MDS, Legrand or similar.Inspection : consignee
"Supply of RJ 11 two way rosette box Numbers concealed type of reputed make as crabtre MDS, Legrand or similar Inspection : consignee"
"Supply of GI back box for 4 modules to fix Numbers RJ45/RJ-11/TV sockets into the box with suitable 4 way faceplate Inspection : consignee"
Fixing of GI back box of 2 way/ 4way/ 6way Numbers and fixing the RJ11/RJ45/dish socket and terminating the suitable wires into the socket and installation of suitable face plates as per instruction of site incharges
Suppy and fixing of PVC pipes concealed Metre type duly breaking concrete bed /wall levelling surface by using cement, sand etc and drawing different types of cable through it (all the required material for except cable should be arranged by the contractor Inspection : consignee
"Supply of Indoor Access Points Similar to Numbers T P Link EA225-POE or better .Inspection : consignee" Total 1601920.14
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRGCC-2022with_ASC1TO11_compressed.pdf
ATTACHMENT
TechnicalGuidelinesPCSTE.pdf
ATTACHMENT
ConservancyCharges.pdf
ATTACHMENT
AnnexureVGCCcorrespondence_1.pdf
ATTACHMENT
TenderBookSpecialCondition.pdf
ATTACHMENT
InspectionClause_1.pdf
ATTACHMENT
JPO
ATTACHMENT
TechnicalSpecification.pdf
ATTACHMENT
InclusionofnewJPOinWTTLettertoPCOM01.05.2024withencloser-pages_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid