| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | ₹34.8 L Quoted ₹35.3 L | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹36.4 L+₹1.1 L (3.25%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹36.4 L+₹1.1 L (3.25%) | L2 | Rejected-Finance Being Other than Lowest Tenderer |
| 3 | L3₹36.6 L+₹1.3 L (3.64%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹36.6 L+₹1.3 L (3.64%) | L3 | Rejected-Finance Being Other than Lowest Tenderer |
| 4 | L4₹37.1 L+₹1.8 L (5.18%)Rejected-Finance NOT AVAILABLE | ₹37.1 L+₹1.8 L (5.18%) | L4 | Rejected-Finance Being Other than Lowest Tenderer |
| 5 | L5₹37.9 L+₹2.6 L (7.36%)Rejected-Finance ROOM NO 214 GANESH MURTHY NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹37.9 L+₹2.6 L (7.36%) | L5 | Rejected-Finance Being Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | SHRI SAI ENTERPRISES L2 | ASHOK ENTERPRISES L3 | Pragathi Infrastructure Co. L5 | MAA VAISHNAV CONSTRUCTION L1 | SHREE JAGDISH FURNITURE CO. L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for comprehensive maintenance by attending complaints of ceiling fan/exhaust fan/wall mounted fan etc to make serviceable by replacement of defective parts complete all as specified and directed by Engr-in-Charge for the following locations :-
(a) Vajrabahu (b) DGNP (c) CG Complex (d) LWT (e) HQ WNC (f) NAD (g) New flotila Niwas (h) CCDT (j) CNAI
Note : (i) Spare parts of for repair/replacement shall be measured and paid separately under respective items.
(ii) Cost of manpower (01 electrician and 01 helper for replacement of spare parts as per requirement basis deemed to be included in the quoted rate. | 11 | Each month | 43,000 ₹4,73,000 | 23,000 ₹2,53,000 Lowest | 50,000 ₹5,50,000 | 30,000 ₹3,30,000 | 27,000 ₹2,97,000 |
| 2.00 | M&L for comprehensive maintenance by attending complaints of ceiling fan/exhaust fan/wall mounted fan etc to make serviceable by replacement of defective parts complete all as specified and directed by Engr-in-Charge for the following locations :-
(a) INS Angre (b) HQ MNA (c) Noorbuoy (d) Rafiya Manzil (e) PCDA office (f) INS Kunjali (g) BV Yard
Note : (i) Spare parts of for repair/replacement shall be measured and paid separately under respective items.
(ii) Cost of manpower (01 electrician and 01 helper for replacement of spare parts as per requirement basis deemed to be included in the quoted rate. | 11 | Each month | 43,000 ₹4,73,000 | 23,000 ₹2,53,000 Lowest | 50,000 ₹5,50,000 | 30,000 ₹3,30,000 | 27,000 ₹2,97,000 |
| 3.00 | Supply and fixing in replacement of of BLDC ceiling fan 1200 mm sweep, BEE 5 Star rated, 230 Volt alongwith connected accessories complete all as specified and directed.
Note : The cost of taking down existing and fan and depositing to MES store yard is deemed to be included in the quoted rates. | 210 | Each | 2,010 ₹4,22,100 | 2,600 ₹5,46,000 | 2,000 ₹4,20,000 Lowest | 2,300 ₹4,83,000 | 2,700 ₹5,67,000 |
| 4.00 | All as per item No. 3 above here-in-before but for BLDC ceiling fan 1400mm sweep complete all as specified and directed. | 160 | Each | 3,630 ₹5,80,800 | 2,800 ₹4,48,000 | 2,400 ₹3,84,000 Lowest | 2,600 ₹4,16,000 | 3,700 ₹5,92,000 |
| 5.00 | All as per item No. 3 above here-in-before but for remote operated BLDC ceiling fan 1200mm sweep complete all as specified and directed. | 140 | Each | 2,010 ₹2,81,400 Lowest | 2,600 ₹3,64,000 | 2,800 ₹3,92,000 | 3,000 ₹4,20,000 | 2,985 ₹4,17,900 |
| 6.00 | Dismantaling / opening exhaust fan of 300 mm sweep, transporting to civil workshop and taking out all burnt/damaged windings insulating materials & cleaning internally as well as externally, rewinding the fan motor with super enamelled copper wire as as per existing size /specification, replacement of complete insulating materials, varnishing drying up, cleaning & greasing of bearing / buses using new grease, reassembling and testing complete all as specified and directed.
NOTE : Necessary spares such as bearing / bushes, capacitor, 3 core flexible wire, canopy etc. shall be measured and paid separately under relevant item here in after. | 355 | EACH JOB | 500 ₹1,77,500 | 230 ₹81,650 | 280 ₹99,400 | 330 ₹1,17,150 | 145 ₹51,475 Lowest |
| 7.00 | All as per ser item No. 6 here-in-before but for exhaust fan of 380/450 mm sweep complete all as specified and directed. | 200 | EACH JOB | 500 ₹1,00,000 | 230 ₹46,000 | 330 ₹66,000 | 280 ₹56,000 | 148 ₹29,600 Lowest |
| 8.00 | M&L for replacement of ball bearing suitable for exhaust fan 300 mm sweep size including taking down the unserviceable one complete all as specified and directed
MAKE : TATA/NBC/SKF | 355 | Each | 50 ₹17,750 Lowest | 230 ₹81,650 | 50 ₹17,750 Lowest | 50 ₹17,750 Lowest | 147 ₹52,185 |
| 9.00 | M&L for replacement of gun metal bush suitable for exhaust fan 300 mm sweep size and make after taking down the unserviceable one complete all as specified and directed. | 355 | Each | 50 ₹17,750 | 230 ₹81,650 | 30 ₹10,650 Lowest | 40 ₹14,200 | 95 ₹33,725 |
| 10.00 | M&L for replacement of ball bearing suitable for exhaust fan 380/450 mm sweep size including taking down the unserviceable one complete all as specified and directed
MAKE : TATA/NBC/SKF | 200 | Each | 50 ₹10,000 Lowest | 250 ₹50,000 | 50 ₹10,000 Lowest | 50 ₹10,000 Lowest | 125 ₹25,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
4 Aug 2026, 6:55 pmClosed
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8349 COMPREHENSIVE REPAIR AND MAINTENANCE OF VARIOUS TYPES OF FANS, FITTINGS AND FIXTURES AND OTHER CONNECTED WORKS OF INTERNAL ELECTRIC SUPPLY FOR BLDGS UNDER HQ MNA AND HQ WNC AT GE (NW) KUNJALI
2026_MES_778541_1
8349/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
11 Sept 2026
14 Jul 2026
6 Aug 2026
25 Jul 2026
4 Aug 2026
29 Jul 2026
14 Jul 2026 - 25 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for comprehensive maintenance by attending complaints of ceiling fan/exhaust fan/wall mounted fan etc to make serviceable by replacement of defective parts complete all as specified and directed by Engr-in-Charge for the following locations :-
(a) Vajrabahu (b) DGNP (c) CG Complex (d) LWT (e) HQ WNC (f) NAD (g) New flotila Niwas (h) CCDT (j) CNAI
Note : (i) Spare parts of for repair/replacement shall be measured and paid separately under respective items.
(ii) Cost of manpower (01 electrician and 01 helper for replacement of spare parts as per requirement basis deemed to be included in the quoted rate. | 11 | Each month | - | - |
| 2 | M&L for comprehensive maintenance by attending complaints of ceiling fan/exhaust fan/wall mounted fan etc to make serviceable by replacement of defective parts complete all as specified and directed by Engr-in-Charge for the following locations :-
(a) INS Angre (b) HQ MNA (c) Noorbuoy (d) Rafiya Manzil (e) PCDA office (f) INS Kunjali (g) BV Yard
Note : (i) Spare parts of for repair/replacement shall be measured and paid separately under respective items.
(ii) Cost of manpower (01 electrician and 01 helper for replacement of spare parts as per requirement basis deemed to be included in the quoted rate. | 11 | Each month | - | - |
| 3 | Supply and fixing in replacement of of BLDC ceiling fan 1200 mm sweep, BEE 5 Star rated, 230 Volt alongwith connected accessories complete all as specified and directed.
Note : The cost of taking down existing and fan and depositing to MES store yard is deemed to be included in the quoted rates. | 210 | Each | - | - |
| 4 | All as per item No. 3 above here-in-before but for BLDC ceiling fan 1400mm sweep complete all as specified and directed. | 160 | Each | - | - |
| 5 | All as per item No. 3 above here-in-before but for remote operated BLDC ceiling fan 1200mm sweep complete all as specified and directed. | 140 | Each | - | - |
| 6 | Dismantaling / opening exhaust fan of 300 mm sweep, transporting to civil workshop and taking out all burnt/damaged windings insulating materials & cleaning internally as well as externally, rewinding the fan motor with super enamelled copper wire as as per existing size /specification, replacement of complete insulating materials, varnishing drying up, cleaning & greasing of bearing / buses using new grease, reassembling and testing complete all as specified and directed.
NOTE : Necessary spares such as bearing / bushes, capacitor, 3 core flexible wire, canopy etc. shall be measured and paid separately under relevant item here in after. | 355 | EACH JOB | - | - |
| 7 | All as per ser item No. 6 here-in-before but for exhaust fan of 380/450 mm sweep complete all as specified and directed. | 200 | EACH JOB | - | - |
| 8 | M&L for replacement of ball bearing suitable for exhaust fan 300 mm sweep size including taking down the unserviceable one complete all as specified and directed
MAKE : TATA/NBC/SKF | 355 | Each | - | - |
| 9 | M&L for replacement of gun metal bush suitable for exhaust fan 300 mm sweep size and make after taking down the unserviceable one complete all as specified and directed. | 355 | Each | - | - |
| 10 | M&L for replacement of ball bearing suitable for exhaust fan 380/450 mm sweep size including taking down the unserviceable one complete all as specified and directed
MAKE : TATA/NBC/SKF | 200 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_871974.xls
BOQ • 2.17 MB
8349TENDERDOCUMENT.pdf
Tender Documents • 1.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .