Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹23.9 L+₹91,512 (3.99%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
28 Sept 2020, 6:00 pmClosed
GE MINNIEBAY
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / MAINT AND ATTENDING WATER SUPPLY COMPLAINTS FOR LEAKAGES/ BLOCKAGES OF PIPE LINE INCLUDING CONNECTED WORKS AT MINNIEBAY AREA UNDER AGE E/M II AT GE MINNIEBAY, PORT BLAIR
2020_MES_373320_1
8874/E8
Open Tender
Civil Works
Item Rate
365 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE, Minniebay, Junglighat (PO), Port Blai
₹60,000
Yes
30 Jan 2021
1 Sept 2020
3 Oct 2020
1 Sept 2020
28 Sept 2020
14 Sept 2020
Amount
M&L for detecting and repairing leakage in CI/DI pipe lines of size 300/350/400mm bore, taking up unserviceable /serviceable CI/DI water main with spigot and socket ends (including fittings) of any type/grade and joints from trenches and laying new CI/DI pipe lines of size 300 /350 /400mm bore in trenches or placing on existing pillers /supports as directed and specified to includnig the following:-
Execution and earth work in soil / mud by using machinery/labour to suitable length (Appx 10 mtrs) and forming bund with excavated soil to avoid sea / row water entering into the working area including pumping / bailing out water by using portable desal engine driven pump set.
Cutting of CI / DI pipe of size 300mm/350mm/400mm bore after through inspetion for the damaged pipe line including disconnecting / dismantling.
Taking out CI/DI pipe with CI/DI specials after removing from joints/burning out joints and removing lead at both ends with the help of hydrolic crane other machinery and keeping aside for further disposal.
Cutting of new pipe into pieces as per rquirement and laying using machinery.
Alinging the pipe line as per site condition, in setting the CI Collar suitable for 300/350/400mm CI/DI pipe.
Attending repair work within the minimum time frame/period as specified by Engr - in - charge.
Notes for Items No 01 above :- (a) The unit rate is deemed to include cost of tools and plants and transprtation required for attending the repair work. (b) Supply only CI/DI pipe shall be measured & paid for seperately under relevant item of this schedule. (c) Extra soil required for refilling / making bunds to prevent water entering into the work place shall be deemed to include in the unit rate. (d) Specials / rubber or fiber/ lead joints shal be measured and paid for seperately under relevent items of this schedule. (e) Old unsv CI/DI pipes, fittings, lead, nuts, bolts, washer, gaskets etc. shall become contractors property and necessary recovery as per schedule of credit shall be deducted from contractor..
All as per item No 1 above but for CI/DI pipe line of size 200/250mm
All as per item No 1 above but for CI/DI pipe line of size 80/100/150mm
M&L for attending of water supply complaints for any leakage/blockage in GI pipe lines of size 20mm/25mm bore taking up serviceable / unserviceable GI water pipe lines with all fitings/fixtures from trench including supply and laying GI tubing 20mm/25mm bore up to 1 mtr length (max) including necessary cutting, treading and replacement of unserviceablel GI fittings such as GI socket /Nipple/union socket, Tee, Tee reducer etc. of size 20mm/25mm including necessary excavation and earth work upto 1 mtr length to repair the leakage/clearing the blockage in the pipe line and testing on completion Note : Replacement of unserviceable GI fittings such as GI socket /Nipple/union socket/Tee/Tee reducer etc. shall be measured and paid separately under relevant items of this Schedule
All as per item No 4 above but of size 40/50mm bore GI pipe line
All as per item No 4 above but of size 80/100mm bore GI pipe line
All as per item No 4 above but of size 25/25mm bore GI pipe lines on wall/floor/roof
All as per item No 4 above but of size 40/45mm bore GI pipe lines on wall/floor/roof
All as per item No 4 above but of size 80/100mm bore GI pipe lines on wall/floor/roof
Excavating in trenches in soft / loose soil, n.exc 1.5m wide and n.exc 1.5m in depth: for foundation, etc. or for shafts, wells, cessapits, manholes, pier holes, etc. n.exc 10 Sq.m on plan and in.exc 1.5m in depth and getting in soft/dense soil out all as specified and directed.
Excavating in trenches in hard / dense soil, n.exc 1.5m wide and n.exc 1.5m in depth: for foundation, etc. or for shafts, wells, cessapits, manholes, pier holes, etc. n.exc 10 Sq.m on plan and in.exc 1.5m in depth and getting in hard/dense soil out all as specified and directed
Returning, filling in, using excavated soil including spreading, levelling watering and well ramming in layers n.exc. 25cm as specified and as directed.
Removing the surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point.
Taking up or down old/chocked water tubing 20/25/50 mm bore with fittings from trenchs/walls cleaning for refixing in new or old position or credit to contractor all as specified and as directed.
Supply and fix in replacement of 20mm dia CPVC pipes SDR 11 including fittings on walls/ceilings/laying in trenches complete all as specified and as directed.
Supply and fix in replacement of 25mm dia CPVC pipes SDR 11 including fittings on walls/ceilings/laying in trenches complete all as specified and as directed.
Supply and fix in replacement of 50mm dia CPVC pipes SDR 11 including fittings on walls/ceilings/laying in trenches complete all as specified and as directed.
Supply and Fix CPVC male brass threaded adaptor (MTA/MBTA) suitable for 20 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC male brass threaded adaptor (MTA/MBTA) suitable for 25mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC male brass threaded adaptor (MTA/MBTA) suitable for 50mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC female brass threaded adaptor (FTA/FBTA) suitable for 20 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC female brass threaded adaptor (MTA/FBTA) suitable for 25 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC female brass threaded adaptor (MTA/FBTA) suitable for 50 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC tank adaptor suitable for 20/25 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC union suitable for 20 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC union suitable for 25 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC union suitable for 50 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC ball valve suitable for 20 mm CPVC pipe Complete all as specified and directed
Supply and Fix CPVC ball valve suitable for 25 mm CPVC pipe Complete all as specified and directed
S&F in replacement tubes medium grade galvanized with all fittings, laid in trenches/fixed on wall/on roof etc of the following sizes all as specified as directed :-
20mm dia
25mm dia
40mm dia
50mm dia
80mm dia
100mm dia
M&L for Ductile Iron pipes with spigot and socket ends centrifugally cast class in any length, laid in trenches of following sizes all as specified and directed :-
80mm bore
100mm bore
150/200/250mm bore
Supply and fixing in replacement Gun Metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of the following sizes all as specified and directed :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and fix in replacement of flanged type Sluice valve hand wheel operated CI Body with SS spindle PN-1.0 rating, IS-14846 of following sizes all as specified and directed :-
80mm bore
100mm bore
150mm bore
200/250 mm bore
S&F in replacement of CI/DI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot or flanged) collars, caps and plugs upto 150mm bore all as specified and directed
Supply only Union socket GI medium grade of following sizes all as specified and directed :-
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
Supply only GI Nipple 6" long of following sizes :-
20mm dia
25mm dia
40mm dia
50mm dia
S&F in replacement joint with rubber or fiber board gasket (flange joints) suitable for flanged pipes and fittings of the following sizes :-
(a) 80mm bore
(b) 100mm bore
(c ) 150mm bore
Supply only of GI Tee Reducers medium grade Make Bansal/Jindal/Tata of the following sizes :-
S&F Gland packing 12.5mm/10mm dia / thick for sluice valve / pumps
Taking down UNSV sluice valves and Re-fixing the same in its original position/location with flanged ends including necessary cleaning, resetting & minor repairs for its smooth functioning , any pattern of following sizes :-
S&F in replacement rubber gasket joint suitable for spigot and socket pipes and fittings for the following size as specified and directed.
S&F in replacement Lead wool joint suitable for spigot and socket pipes and fittings for the following size as specified and directed :-
S&F in replacement Run lead joint suitable for spigot and socket pipes and fittings for the following size as specified and directed
M&L for fabrication of MS sheet (3.15mm thick) for valve chamber cover with plates of Fe 410W, Gde E-250, quality -A (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment for locking arrangements complete including painting with two coat of synthetic enamel paint black colour/shade over a coat of redoxide primer complete all as specified and directed including taking down old one.
Taking down UNSV/rusted MS ladders of any size / type from site and transporting to store yard for further disposal.
M&L for fabrication of mild steel (MS) Ladder at local civil work shop made out of angle iron of size 65X65X6mm for main member, 50X50X6mm for steps and 40X40X5mm for support to existing wall of the building including necessary cutting, welding, grainding etc, the distance between two concecutive steps shall be 0.30 mtr, the distance between 1st step and ground level shall be 1mtr and over all width of the ladder shall be 0.68 mtr,total length of the ladder shall be suitable for multi storey bldgs viz G+1 , G+2 and G+3 / under ground sump as required & transporting to site in Minniebay Area, grouting the ladder in ground (at various locations of Ajay Baugh and Srinagar area) and grouting the supporting angle iron member with existing wall of the bldg with PCC 1:2:4 and top of the ladder shall be supported with parapet wall/top slab of the bldg including painting with two coats of synthetic enamel paint black/smoke grey colour/shade over a coat of red oxide primer all as specified and directed
Supply and lay in replacement DI pipes of grade K-9 with S/S ends centrifugally cast in any length complete all as specified and as directed for following sizes:
350 mm dia
400 mm dia
M&L for tyton joints suitable for DI pipe of size :-
80 mm dia
100 mm dia
150 mm dia
200/250 mm dia
350 mm dia
400 mm dia
M & L for CI/DI pipe specials of class 'A' and 'B' such as Tees, bends, sockets, collars, junctioning couplings etc for new position with the help of connecting pieces for up to 350 mm dia CI/DI pipe line all as specified and as directed including taking down existing specials.
Supply, lay and testing of ERW MS pipes, in replacement ISI marked grade 6 mm thick as per IS : 3589 grade 330 suitable for welded joints and flanged joints including fabricating tailor made sepials as per site requirement including painting with two coats of anticorrosive paint complete all as specified of 250 mm dia after bailingout water from existing semi UG sump of Cap.30000 Gallons with Appx. 7 Mtr.depth at command Swimming Pool filtration Plant at minniebay.
Supply and fix nuts,bolts, washers for valves and pump sets of various sizes as required.
Supply only TDS testing kit for pump house to check TDS valve
Supply only Chlorine testing kit fo pump house to calibirate chlorine value
Supply only Orthotodiline chemical solution for checking chlorine content in water
Supply and fix in repalcement of MCCB 250 Amp , 3 pole,415 volts for Motor starter incoming all as specified.
Supply and fix in repalcement of MCCB 160 Amp , 3 pole,415 volts for Motor starter incoming all as specified.
Supply and fix in repalcement of Contactor 3 pole 415 volts 70 Amps ML-4(control voltage 230/415 as per existing model.) all as specified and directed.
Supply and fix in repalcement of Contactor 3 pole 415 volts 40 Amps ML-3(control voltage 230/415 as per existing model.) all as specified and directed.
Disconnecting electrical connection of Centrifugal pump set of capacity 30/40HP/60 HP and taking out complete assembly with electric motor, transporting to workshop and testing the complete and refixing with new, nuts, bolts & washers and fitting the same after the following repairs as mentioned here in after all as directed.
M&L for re-winding of unserviceable/burnt Centrifugal pump set of capacity 30/40/60HP HP, removing all burnt out coils, cleaning the slots and rewinding the same with supper enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running of the capacity 30 /40/60HP complete in all respects to the entire satisfaction of Engr-in-Charge
S&F in replacement of Rotational moulded polyetheylene (HDPE) Water Tanks, Cylindrical & Vertical Type, double layered, ISI marked, hoisted and fixed in position including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete including taking down old tanks and removing to store complete all as specified and as directed of following capacities :-
500 Ltr capacity
1000 Ltr capacity
2000 Ltr capacity
M&L for repair / maintenance to Decrin dozing pump including replacement of UNSV spare parts Rotor assy with bearings bracket, Pump tube,Injection check valve 3/8",Weighted suction line strainer 3/8",Connecting nut 3/8" with adopter,Ferrule 1/4" etc and testing on completion for its smooth functioning to the entire satisfaction of Engr-in-Charge .
S&F in replacement, CI foot valve of size 250/200/150/100mm, heavy duty ( confirming to relevant IS fixing with provision of new rubber flange gasket, nut, bolt, double washer, etc., complete including dismantling of unserviceable valve from UG sump at command Swimming Pool filtration Plant/ minniebay pump house. all as specified and as directed.
Taking down unserviciable air release valve and refixing the same in its original position / location with nuts and bolts by replacing / repair of minor spare parts like ball valve tap, gaskets and necessry cleaning for its smooth functioning of following sizes:-
Kathir Marketing Services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .