Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹35.6 L+₹1.2 L (3.45%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹36.1 L+₹1.7 L (5.05%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹36.7 L+₹2.3 L (6.60%)Rejected-AOC SHOP NO 4 SUN STAR CHS LTD PLOT NO 309 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹36.8 L+₹2.4 L (7.01%)Rejected-AOC 1ST FLOOR SIDDHI PUJA BUSINESS SQUARE SONY PAITHANI CHOWK NASHIK MAHARASHTRA INDIA PIN 422 002 | NASHIK | MAHARASHTRA | 422002 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
18 Jan 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-88
REPAIRS TO ROOF, LEEKAGE/ SEEPAGE,WATER PROOFING TREATMENT AND CERTAIN CIVIL WORKS AT OTM AND MD ACCN OF TS MAHUL UNDER GE (NW) MANKHURD
2024_MES_636373_1
8287/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹70,000
15 Feb 2024
8 Jan 2024
22 Jan 2024
8 Jan 2024
18 Jan 2024
11 Jan 2024
Amount
M & L for aluminium anodised suspended false ceiling fixed in repairs in the panels of size consisiting of 600x600 mm lay in tiles 8 mm thick with PVC lamination on the face side and metalized polyester film on backside as granular pattern of saint gobain/Armstrong /equivalent; with aluminium anodised angle 30 x30 x 2 mm fixed along the wall and main and cross tees of size 31.75 x 31.75 x 1.6 mm screwed along side of walls fixed with wooden plugs and hanging from existing slab/ steel truss including 6 mm dia GI wire suspended adjustable level from rafter purlins(length as per site requirement) including complete all as directed by Engineer-in-charge. Note : The contractor's quoted rates shall also be deemed to include for making/ cutting opening in the ceiling of the required size and shape for fixing light fitting, cat walk and provision of neccesary scaffolding for complete work at maximum height of 8mtrs etc, complete all as directed.
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty over new surfaces Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on concrete surfaces etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 5mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete all as specified. and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 5mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including Preparation of new plastered surfaces and applying three coat of white wash complete all as specified.
Providing and fixing additional steel bar in various structural elements like column ,beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc.
S&F in repairs Pre-painted Corrugated galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. completely all as specified and as directed. upto maximum height of 12 Mtr
S&F in repairs Pre-painted Plain galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. completely all as specified and as directed. upto maximum height of 12 Mtr
M & L for special treatment for sunken portion of WC bath toilet kitchen etc executed in following stages stage 1 providing 15 mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr fixit or shalicrete R of STP ltd in the proportion/quantity all as per manufacturers instructions stage 2 Application of 1 st coat of tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces Stage 3 Application of 1 st coat of tarfelt LM of STP Ltd (without dilution with water) @ 1kg/sqm by brush all as per manufacturers instructions. Stage 4 Laying fibre glass cloth ( weight not less than 50 gm/sqm) over 1 st coat while the coated surface is still sticky Stage 5 After 6 to 7 hours iterval, apply second coat ie final coat of tarflet LM of STP ltd (without dilution with water) @ 1 kg/sqm by brush as per manufacturers instructions. Stage 6 Providing 10 mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250 ml/50Kg cement all as per manufacturer's instructions. Stage 7 Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion. Notes: (i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid.
M&L for Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc to a distance exceeding 500m and not exceeding 1.0km complete all as specified and directed by the Engineer-in-charge and providing complete surface preparation prior to further application using wire brush the surface ,ensure complete crack filling using polymer modified mortar of Dr Fixit Crack -xX Paste, Dr Fixit Crack -X Shrinkate of Shaliseal CPM from STP Ltd ,allow to dry it for 24 hrs afterwards wet the surface , brush apply 1 primer coat of Dr Fixit Primeseal or equivalent primer ,over that brush apply 1 coat of water proofing coating over the primed surface , over that over lay a open woven fibre glass mesh , min 40 GSM of size 2 mm x 2 mm & allow it to soak completely and immidiately apply the second coat of Dr Fixit New coat , Water seal concerntrate of M/s Krishna Conchem Products, Shalicryl 215 of STP Ltd with a roller , to ensure complete coverage of the fibre mesh. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L for Providing waterproofing treatment as specified below and at any height of roof surface including removal of watertank, plumbing line during waterproofing making good if any holes and refixing the same as directed by Accepting officer and Engineer in charge complete 1) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-charge 2) M&L for averaging 50 mm thick PCC 1:2:4, type -B-1, using 20mm graded stone aggregated as in padding concrete of roof mixed with WPC in the proportion as recommanded by the manufacturer(s), complete all as specified and directed, 3) M&L 10 mm thick Screed bed or bedding layer in CM (1:3) with WPC when the concrete is still green complete all as specified and directed. 4) M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a). The roof surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b). The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane. (c). Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before. (d). The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. (e). The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant.
M&L for Providing waterproofing treatment as specified below and at any height of roof,parapet wall, facia and Chajja surface including removal of watertank, plumbing line during waterproofing making good if any holes and refixing the same as directed by Accepting officer and Engineer in charge complete 1) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-charge 2) M & L for APP modified roof treatment over parapet wall, facia and Chajja etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a). The roof surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b). The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane. (c). Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before. (d). The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. (e). The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Prepolished Kota stone slab 20-25mm thick in riser/treads/landing of steps,in full piece with bull nosing and laid over cement screed and jointed including Screed/backing coat 15mm thick in CM 1:3.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured 450x300x6mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the colour of tiles, over and including 10mm thick cement mortar backing coat in CM 1:4, complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured vitrified tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile not exceeding 0.36 Sqm in floors/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed.
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of grills (where exists), complete all as specified and directed and S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately as supply only under respective items.
S&F aluminium anodised Grills of approved design for window / Bolcony ventilators and fixing with F/U channel for window, ventilators, balcony openging in architectual or rectangular type in existing building with C.P. brass/ stainless steel screws @ 200 mm centre to centre, , including drilling as required in RCC sections, complete all as specified and directed. Note: The Grills shall be of Model DG-102/DG-104 of Make Deco or equivalent make as approved by the GE.
M&L for 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/rectangular size as required in each pane for Partition/Door/Window/Ventilator and similar works etc.
Supply and fixing in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Supply only stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
M&Lfor Granite (of any tpe), fixed in repairs 20 mm work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
M&L Rounding to edges of stone slabs of Granite or Green Marble of any thickness one edge such as in steps (Bull nosed) or Half round in cooking platform,and other similar situations completely all as specified and as directed by Engineer in Charge.
Taking down chowkats or frames, not exc 2 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall beacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.
S&Faluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixedd nuts, four on bolt plate and two on staple plate and fixed,300mm complete. fixed in repairs
S&F aluminium, anodised, barrel tower bolts of extruded section and fixed 150 mm fixed in repairs
S&F Stainless butt hinges with brass screws, size 100mm fixed in repairs
S&F extruded aluminium alloy handles, fabricated type., anodised,150 mm fixed in repairs
S&F in repairs vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia fancy type pillar tap of Make ESSCO Model no DLX-507KN or equivalent of make Parko as approved by the GE, , chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.
S&F in repairs vitreous china urinal half stall type (back or corner wall type ), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with discharge pipe etc complete all as specified and as directed by Engineer In Charge.
S&F in repairs vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, with 'P' or 'S' trap, integral foot rests including flush pipe, trap, lime concrete bedding inlcuding taking out of old lime concrete bedding, unserviceable connections etc and connecting up new complete all as specified and directed by the Engineer-in-charge
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete. Jaquar Essco Model No of EWC - ECS-WHT-551SNPP183LZ or ECS-WHT-551PNPP183LZ
M&L for fixed in repairs 15 mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified , Cat No 187 of Prayag or equivalent make as approved by the GE complete all as speicified
S&F fixed in repairs Two way Bib cock with flange 15mm dia Model no DLX-512ANKN of ESSCO or equivalent of MarC ,Parko as approved by the GE complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Stop Cock, Make ESSCO Model no DLX-526NKN or equivalent of make Parko as approved by the GE, complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Bib Tap, Make ESSCO Model no DLX-511KN or equivalent of make parko as approved by the GE, complete all as specified and directed.
S&F in repairs brass chromium plated, shower rose, 125mm size with and including 195mm long 15mm bore brass chromium plated shower arm with bend of 45 degree, complete all as specified and directed.
S&F for PVC (SWR) multi floor trap 75mm dia with grating including jointing with solvent cement
Supplying and laying in repairs against any dia GI tubing of 16mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
Supplying and laying in repairs against any dia GI tubing of 20mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
Supplying and laying in repairs against any dia GI tubing of 25mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors 110 dia.
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors but 75mm dia
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 110mm dia
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 75mm dia
M&L for PVC (SWR) bends fixed in repairs any radius of 110mm dia
M&L for PVC (SWR) bends fixed in repairs any radius of 75mm dia
M&L for PVC (SWR) bends fixed in repairs any radius of 110mm dia provided with access door
M&L for PVC (SWR) bends fixed in repairs any radius of 75mm dia provided with access door
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 110mm dia bore provided with access door
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 75mm dia bore provided with access door
M&L for PVC (SWR) fixed in repairs vent cowl of 110mm dia
M&L for PVC (SWR) fixed in repairs vent cowl of 75mm dia
Cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for and forming channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required internal dia of pipe 150mm maximum
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity 1000 Ltr complete fixed to pipe etc all as directed
S&F in repairs ball brass valves high pressure with polyuthene float valve and fly nutcomplete screwed for iron pipe or brass ferrule and fiexed in repairsFloat valve 20mm
S&F in repairs Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in repairs 20mm bore
M&L for Cement concrete in C1 type (1:3:6) using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement.
M&L Precast cement concrete cover slabs 75mm thick and Crossectional area exc 0.36 Sqm and n.exc 0.5 Sqm each for drain cover and similar work with plain faces set in cement mortar 1:6 complete all as speicified and directed.
Preparation of old surfaces on walls (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
Preparation of old surfaces on ceiling (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
M & L for complete removal of existing treatement preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty of minimum 1mm thickness over new surfaces
M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.
Preparation of old surfaces on walls (plastered or unplastered or previously colour washed) and applying one coat of Colour wash complete all as specified.
Preparation of old surfaces on ceiling. (plastered or unplastered or previously colour washed) and applying one coat of Colour wash complete all as specified.
Preparation of old surfaces on walls (plastered or unplastered or previously distempered ) and applying one coat of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. complete all as specified.
M & L for preparation of old wooden surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old wooden surfaces of any description n.exc 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old painted steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old Steel surfaces of any description n.exc 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old surfaces for applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm Note : A sum of Rs 39262.00 towards sch of credit shall be deducted to arrive the contract sum.
SHREE SHIV SHANKER ENTERPRISE
M/s Mukesh Engineers
Parmatma Enterprises
M/s Mohd Altaf Hanif Qureshi
Joy builders
KRISHNA ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .