SE/DEDC/DHARMAPURI
The Superintending Engineer/TANGEDCO DEDC/Dharmapuri
Construction of section office building at Keeraipatty in Harur Division/DEDC/Dharmapuri Electricity Distribution Circle.
2020_EB_171291_1
T.S.N0.031/19-20 of SE/DEDC/DPI
Open Tender
Civil Works
Item Rate
90 days
Keeraipatty
As BQR condition
2 documents required · 2 mandatory
₹0
₹21,400
Yes
4 Aug 2020
14 Jul 2020
23 Jul 2020
14 Jul 2020
22 Jul 2020
15 Jul 2020
14 Jul 2020 - 15 Jul 2020
Amount
Earth work excavation in all types of soils with an initial lead of 10 m and lift of 2m and disposing the excavated earth as directed by the Engineer at site etc complete-Hard gavely soil
Earth work excavation in all types of soils with an initial lead of 10 m and lift of 2m and disposing the excavated earth as directed by the Engineer at site etc complete-SDR not requring blasting
Earth work excavation in all types of soils with an initial lead of 10 m and lift of 2m and disposing the excavated earth as directed by the Engineer at site etc complete-MR and DMR not requring blasting
Earth work excavation in all types of soils with an initial lead of 10 m and lift of 2m and disposing the excavated earth as directed by the Engineer at site etc complete-Hard rock requring blasting
Plain cement concrete 1:4:8, Using 40 mm HBG machine crushed metal for foundation padding concerete including cost of cement all materials,labour,lead,lift curing etc., complete.
PCC 1:3:6 using 40 mm HBG machine crushed metal for septic tank foundation padding concerete including cost of cement all materials,labour,lead lift, curing etc., complete.
Random rubble masonry in CM 1:5 mix using good quality rough stone for foundation and basement including cost of all materials lead and lift etc., complete.
RCC 1 :1.5:3 mix using 12 to 20mm HBG metal for plinth beam with formwork including cost of all labour materials lead lift etc complete but exculding cost of steel reinforcement
Brickwork in cm 1:5, using good quality country brick of size 23x11x7 cm including cost of all materials labour, lead, lift, curing and Transporting charges etc complete.
Brickwork in cm 1:3, for septic tank using good quality country brick of size 23x11x7 cm including cost of all materials labour, lead, lift, curing and Transporting charges etc complete.
RCC 1:1.5:3 mix using 12mm to 20mm HBG metal (machine crushed) for continuous lintel beam. sunshade, slab, with form work including costof all labour materials lead lift curing etc complete but excluding cost of steel reinforcement ( By using mixer machine and vibrator )
Refilling the excavated earth other than sand in basement sides and septic tank including cost of all labour, lead, lift, etc complete.
Filling the basement and dispersion trench with sand including cost of all labour, lead, lift, etc complete.
Filling the dispersion trench with 40mm size HBG jelly including cost of all materials labour, lead, lift, etc complete and as per the instructions of the Engineer at site.
RCC 1:1.5:3 mix using 12 to 20mm HBG metal (machine crushed) for precast RCC slab for septic tank inlet and outlet chamber inspection chamber top cover including cost of cement all materials lead lift curing formwork etc complete but excluding cost of steel reinforcement
Supplying and fixing of non- slippery ceramic tiles of toilets of approved quality laid in cement mortar 1:3 20mm thick over PCC 1:4:8 100 mm thick flooring and finished to slope and hatched including cost of all materials labour, lead lift and curing etc complete..
Daddoing inside the wall at toilet with glazed tiles to a height of 1m over cm 1:3 12mm thick and joint shall be finished with white cement including cost of all materials labour, lead lift and curing etc complete..
Flush pointing with CM 1:3 for RR walls including cost of materials, labour, lead, lift and curing etc complete
Plinth protection in PCC 1:3:6 using 40mm HBG metal for 100 mm thick and finishing the surface with CM 1:3, 20 mm thick including cost of all materials labour lead lift curing etc complete.
RCC Roof slab 1:1.5:3 mix using 12mm to 20mm HBG metal with form work and ceiling plastering with CM 1:3, 12 mm thick including cost of all materials labour lead lift curing etc complete ( Excluding cost of steel reinforcement and using mixer machine and vibrator)
Providing weathering course using best quality of one course of pressed tiles of size 23x23x2cm of approved quality using in CM 1:3 12mm thick and pointed with mortor mixed with crude oil 10% by weight of cement and pointed with the same oil mixed CM 1:3 used over a bed of brick jelly lime concrete of 80mm thick with ratio of 32 : 12.5 etc ( No sand) with the required slope and beaten with wooden beaters including cost of all materials, curing etc complete.
Supplying, fabricating and placing of MS/RTS steel reinforcement for RCC works including cost of cutting, bending, tying and Fixing in position as per specification including cost all materials lead lift cost of binding wire etc complete.
Plastering with CM 1:3, mix 12mm thick for septic tank including all cost of all materials labour lead lift curing etc complete.
Plastering with CM 1:3, mix 20mm thick for septic tank including all cost of all materials labour lead lift curing etc complete.
Plastering with CM 1:5, mix 12mm thick for inside and outside walls including all cost labour materials lead lift etc complete.
Colour washing two coats by using white cement of approved quality with suitable colouring pigments including cost of all materials ,labour lead lift curing etc complete.
Whitewashing two coats by using white cement for inside walls including cost of all materials labour, lead lift curing etc complete.
Distempering two coat over a priming coat with approved by Engineer at site over cement plastered wall surface including cost of all materials, lead, lift, etc., complete - 10M²
Fabricationand supply and fixing of MS steel door with frame of size 40x40x6mm angle and shutter frame of size 35x35x6mm angle using 18 gauge MS sheet 6 nos holdfasts with all fittings including cost of all materials labour, lead, lift priming coat eanmel painting two coats etc and as per the instruction of the Engineer at site etc. complete. Door size 1.20m x 2.10m
Supply and fixing of PVC door of approved quality and colour including cost of all materials, lead, lift etc complete and as per the site Engineers at site.
Supplying and fixing of fully Glazed steel window with outer frame of size 35x35x6mm MS angle and shutter frame of size 25x25x5mm with 10 Nos 12 mm dia MS rod as per the standard specification including cost of all materials , fabrication and transportation charges fixing in position and painting two coats over a priming coat of red oxide and as directed by the site Engineer, glass of approved quality etc. complete.
Fabrication, Supply and fixing of steel glazed ventilator of approved quality and size as dircted by the site Engineer complete in all respects. Ventilator
Wash Hand Basin colour without pedastal of size 550mm x400mm with all acessories such as cast iorn brackets, 32mm dia C.P waste coupling, rubber plug and chain, 32mm dia 'B' class G.I waste pipe, 15mm dia G.M whell value, 15mm dia nylon connection 15mm dia brass nipples, 15mm C.P. Pillar tap etc
Providing and fixing sanitary fittings consisting of Neycer/ Parry ware of oriyya pattern water closet single 60cm with P or S trap connecting with PVC ventilating shaft and Y bend complete including cost of all materials lead lift etc complete.
Supplying and fixing in position of 1000 litres capacity sintex tank of ISI make including cost of all materials transport charges GI nipple, GI Union etc complete
Providing anti termite chemical treatment with approved chemical for the building alround and foundation including cost of materials, labour, making holes etc complete and as per the instructions of Engineer incharge at site
Supplying and fixing of MS grills for window. Collapsible gates, grills for cash counters including cost of all materials, fabrication charges, transportation, fixing etc. complete and as per the instructions of Engineer incharge at site. ( As per standard specification )
Providing projected border of 10 cm width on top of parapet wall in CM 1:3 mix 20 mm thick including cost all materials lead lift curing etc complete.
Providing open drain in cm 1:3 12mm thick with 225mm clear width with PCC 1:4:10 concrete including cost of all materials, labour, lead, lift, curing etc complete.
Supplying, laying and fixing in position of 32mm dia PVC pipe of best quality from approved manufacturer conforming to IS 4985- 1968, 4984- 1970 including cutting threading, jointing with necessary PVC specials including cost of all materials lead, lift, labour etc complete.
Supplying and fixing of 110 mm dia PVC pipe of 4kg/cm2 rain water downfall pipe including all accessories etc complete.
Supplying and fixing of 110mm dia.6 kg/cm2 PVC pipe for sewerage works including all specials like union, elbow etc. complete and as per the instructions of Engineer incharge at site.
Supplying and fixing one side polished 20mm thick cuddappa slab for cupboards including cost of all materials lead lift etc complete
Supplying and fixing 6 levers Godrej lock of approved make and quality including cost of all materials lead lift etc complete.
Supplying and fixing in position 15 mm dia brass screw down bib cock of best quality including cost of all materials, lead, lift, labour etc complete.
Supplying and fixing of 20mm thick paradise granite slab for cash collection points including fixing transport etc compete.in all respects.
Letter writing tariff and slogans including cost of paint, labour for writing complete in all respects.
Labour charges for double nosing the paradise granite slab including cost of labour etc complete in all respects.
Supplying and fixing of ornamental tiles of approved size and model in cm 1:3 20mm thick including cost of tiles, all materials, colour washing etc. complete in all respects.
Supplying and fixing of 110mm dia PVC pipe of 3m height with cowl including all cost of materials lead lift etc complete.for septic tank
Providing inspection chamber of size 0.60x0.60 to a max depth of 0.90m with CI manhole cover including all cost of materails lead lift etc complete.
Engraving the month and year of construction in the plinth of the building including cost of granite stone labour fixing charges etc complete.
Supplying and fixing 100x75mm PVC floor trap in bath room with one PVC door bend , shoe of 75mm dia including cost of all materials lead lift etc complete
Supplying and fixing musical quartz type of wall clock of size 30 *30 cm of approved quality such as Ajantha / Seiko / Citizen etc including cost of transport, fixing charges etc complete.
Wiring with 2x 1.5 sqmm (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitablePVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / Fan point (For Electronic regulator)
Wiring with 2 x 1.5 sqmm (22/0.3) PVC insulated SC. unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid Pipe on wall and ceiling with PVC accessories and with TW switch box and 5A F.T. switch with painting of suitable Colour for open PVC light point / fan point (For electronic regulator. SD 17
Supply and fixing of 5 A 3 Pin and 2 pin combined flush type wall socket with 5A flush type switch concealed in suitable MS box in flush with wall and concealed with 3mm thick hylem sheet. SD 135
Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. SD 88
Supply and fixing of fancy glass shade and 11 W CFL for BH point. SD 80
Supply and fixing of 1200 mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator, with 1 metre down rod with fan clamp with side plates and cross arm of size 450 mm (18")
Supply and fixing of 3 Phase 4 wire ICDB of 16 A per way, with 32 A TPN MC switch with suitable trunking box MS cable entry boxes and internal connection on suitable angle, iron frame work with earth connection only. SD 174
Supply and fixing of 3 Phase 4 wire ICDB of 16 A per way, with 32 A TPN MC switch with suitable trunking box MS cable entry boxes and internal connection on suitable angle, iron frame work with earth connection only. SD 174
Supply and fixing of TNEB meter Board suitable for 32A Three Phase service connection with 3 Nos. 32A Fuse unit (500V) 32A neutral link and earth link (1" x 1/8" Copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit.
Supplying and fixing of AC/DC 76mm Buzzor / call bell suitable for 230v 50 c/s single phase AC supplyon suitable TW board with push switch.SD 101
Earthing as per P.W.D standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32mm complete with necessary masonry work SD 234
P.SELVARAJ
K DHINAKARAN
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .