Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.6 CrAdmitted-Finance GSTIN: 21AAQCS7499N1ZCAT PLOT NO 16 SWEETY COMPLEX P O GANGA NAGAR BHUBANESWAR KHURDA 751003 | BHUBANESWAR | KHURDA | ODISHA | 751003 | -0.50% | ₹4.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.8 CrAdmitted-Finance GSTIN: 21BGLPM0264J1ZIHABITAT STREET MAIN ROAD VIII WARD NO 10 GP WARD WARD NO 10 BLOCK ULB NABARANGAPUR MPL P O DIST NABARANGAPUR 764059 ODISHA | NABARANGPUR | ODISHA | 764059 | +2.00% | ₹4.8 Cr | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical GSTIN: 21ACFPP6964P1ZZ | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Rajani Kanta Panigrahi has not sufficient work experience and intime completion work |
| 4 | Not Admitted-Fee/PreQual/Technical GSTIN: 21BFXPP5441P1ZO | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Sandip Kumar Padhi has not sufficient work experience and intime completion work |
| 5 | Not Admitted-Fee/PreQual/Technical GSTIN: 21ALHPN8902G1Z9 | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Sujit Kumar Nahak has not sufficient work experience and intime completion work |
Tender Value
₹4.7 Cr
EMD Value
₹4.7 L
Closing Date
14 Dec 2025, 4:00 pmClosed
EXECUTIVE OFFICER
CHATRAPUR
Construction Of New Office Building Of NAC Chatrapur
2025_ORULB_122107_1
CTP-NAC-04/2025-26
Open Tender
Civil Works - Buildings
365 days
CHATRAPUR NAC OFFICE
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹4.7 L
Yes
10 Feb 2026
28 Nov 2025
15 Dec 2025
28 Nov 2025
14 Dec 2025
28 Nov 2025
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300mm, removal of stumps of trees cut earlier and disposal of serviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 100 metres including removal and disposal of top organic soil not exceeding 150mm in thickness.
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge. Excavation up to 1.5m height
Supplying filling in F&P with sand including watering, ramming, poking & compacting including Cost, Conveyance, Royalties and Taxes of all materials and cost of all labour with T&P required for the work etc. complete as directed by Engineer-in-charge.
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floor using cement, 4 cm. size black hard crusher broken granite stone metal, screened and washed sharp sand for mortar of approved quality from approved quarry, including hoisting, lowering, laying concrete , ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15cm. thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost of all labours, sundries, T&P required for the work including shoring, shuttering and dewatering, hire & running charges of water pump complete if required as per instruction of the Engineer-in-Charge.
Anti Termite Treatment Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge.
Filling in foundation, plinth and other low laying area with excavated materials including cost of all labour, T&P etc compete including watering and ramming as directed by the Engineer-in-charge.
Double under reamed pile foundation with R.C.C. M25 using 12mm size black hard granite (crusher broken) stone chips including cost of boreholes but excluding cost of M.S. rod/Tor steel and labour chrages for cutting, bending and binding of steel. 375 mm shaft diameter x 7.0 mtr bug double under reamed pile
Double under reamed pile foundation with R.C.C. M25 using 12mm size black hard granite (crusher broken) stone chips including cost of boreholes but excluding cost of M.S. rod/Tor steel and labour chrages for cutting, bending and binding of steel. 375 mm shaft diameter x 7.75 mtr bug double under reamed pile
FOUNDATION Pile Cap
FOUNDATION Plinth Band PB
FOUNDATION RCC Wall
GROUND FLOOR Columns Ground Floor
GROUND FLOOR Beam Ground Floor
GROUND FLOOR RCC Roof slab Ground floor
GROUND FLOOR Lintel ground floor
GROUND FLOOR Chajja Ground floor
GROUND FLOOR Staircase Ground Floor
FIRST FLOOR Columns First Floor
FIRST FLOOR Beam First Floor
FIRST FLOOR RCC Roof slab First floor
FIRST FLOOR Lintel First floor
FIRST FLOOR Chajja First floor
FIRST FLOOR Staircase First Floor
SECOND FLOOR Columns Second floor /terrace Floor
SECOND FLOOR Beam Second floor /terrace Floor
SECOND FLOOR RCC Roof Slab Second floor /terrace Floor
SECOND FLOOR Lintel Second floor
SECOND FLOOR Chajja Second floor
Pile Cap
Plinth Band PB
Columns Ground Floor
Columns First Floor
Columns Second floor /terrace Floor
Roof Beam Ground Floor
Roof Beam First Floor
Roof Beam Second floor/terrace Floor
RCC Roof slab Ground floor
RCC Roof slab First floor
RCC Roof Slab Second floor /terrace Floor
Lintel ground floor
Lintel First floor
Lintel Second floor
Chajja Ground floor
Chajja First floor
Chajja Second floor
Staircase Ground Floor
Staircase First Floor
RCC Wall
Reinforcement Ground Floor (pile +pile cap+grade beam +columns+roof beam+roof slab)
Reinforcement First Floor
Reinforcement Second/Terrace Floor
Providing & laying Brick work with Fly ash bricks of 25 Cm. x 11 Cm. x 8 Cm. size having crushing sfength not less than 75 Kg./Crn2 with dimensional tolerance + 2 % in cement mortar ( 1 : 6 ) in foundation and plinth including the cost of all materials, cost of all labour, conveyance, all taxes, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P etc. complete as per the direction of the Engineer-in-Charge.Foundation
Ground Floor
First Floor
Second /Terrace Floor
Ground Floor
First Floor
Second /Terrace Floor
Ground Floor
First Floor
Second /Terrace Floor
Ground Floor
First Floor
Second /Terrace Floor
First Floor
Second /Terrace Floor
Ground Floor
First Floor
Secound Floor
Ground floor
First Floor
Secound Floor
Ground Floor
Ground Floor
First Floor
Ground Floor
First Floor
Ground Floor
First Floor
Secound Floor
Paneled door Providing and fixing 32 mm local teak wood panelled shutter moulded panels with all labour and fittings and wooden hinged cleats etc. fiitted and fixed complete excluding the cost of Iron fittings. Ground Floor
Fixing glass panes with wooden beading including cost of nails and beadings(Rate as per SOR-2022) Ground floor
Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete :(Rate as per DSR9.56.2 dsr 2023)100x75x3.50 mm
Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete. (Rate as per DSR 9.82 dsr 2023)
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (Rate as per DSR 9.82 dsr 2023)
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (Rate as per DSR 9.83 dsr 2023)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (Rate as per DSR 9.97.1 dsr 2023)250x10 mm
Providing and fixing bright finished brass handles with screws etc. complete : (Rate as per DSR 9.81 dsr 2023)125 mm
Dressed seasoned Sal wood work framed and fixed (wrought and put up) in truss purlins,frames of doors,windows
Ground Floor
First Floor
Secound Floor
Supplying , fitting and fixing of two Track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.
Ground Floor
First Floor
Secound Floor
Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and design with cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.
Ground Floor
First Floor
Secound Floor
Painting Two Coats to New Wood/ Iron Work With S.E Paint over a coat of red oxide primer including cost, conveyance, cost off all materials, cost of all labours, T&P etc. complete as per the direction of the Engineer-in-Charge.
Ground Floor
First Floor
Secound Floor
Finishing wall surface with Acrylic wall putty (water based) of approved make and finished smooth & even surface to receive painting including cost of scaffolding etc. with cost of all materials, labour T&P etc. complete.
Ground Floor
First Floor
Secound Floor
Providing and Painting with Two Coats Plastic emolution
Ground Floor
First Floor
Secound Floor
Paint (interior grade) of approved make & shade / manufactured by reputed manufacture like NEROLAC/ ASIAN/ BERGER/ DULOX or equivalent to make an even finished surface over a coat of water bound cement primer and wall putty in all heights with all scaffolding and staging charges including cost, conveyance, cost off all materials, cost of all labours, T&P etc. complete as per the direction of the Engineer-in-Charge.
Ground Floor
First Floor
Secound Floor
Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade/manufactured by reputed manufacture like NEROLAC/ASIAN/ BERGER/ DULOX or equivalent to make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, cost off all materials, cost of all labours, T&P etc. complete as per the direction of the Engineer-in-Charge.
Ground Floor
First Floor
Secound Floor
Ground Floor
First Floor
Secound Floor
Providing fitting and fixing of Gypsum false ceilling with Aluminium anodised T Section No. 3215 with 2'-0" center to center, L section No. 1705 upto 15 micron on 4 walls to be fixed by means of steel screw and P.V.C plug and the Aluminium grid 2'-0"x2'-0" suspended from ceiling etc complete
Supplying , fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16mm of approved design and quality complete with frame and all fitting and fixtures.
PH WORKS
Structural Glazing Providing and fixing of fixed glazing with top part hung of approved make to be fabricated from roll formed sections made of pre painted steel (base steel as per IS 513 of 0.6 mm thick "d" quality,galvanized as per IS - 277
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge
Ground Floor
First Floor
Secound Floor
Ground Floor
First Floor
Secound Floor
25mm dia C - PVC pipe SDR - 11
32mm dia C - PVC pipe SDR - 11 Top Floor
40mm dia C - PVC pipe SDR - 11 Top Floor
50mm dia C - PVC pipe SDR - 11 Top Floor
Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
15 mm dia CP S.B. Bib cock(CON-CHR-037KN)
15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
25mm dia brass full way valve (Shakti make)
32mm dia brass full way valve (Shakti make)
40mm dia brass full way valve (Shakti make)
50mm dia BFW Valve (Shakti make)
gyser ELM-WHT-V006
WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR)
Hand Dryer SMART FLOW (As per Cat no HDR-WHT-M04A of Jaquar)
15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
15mm CP Extension piece
125mm CP grating
15mm size C.P. flange
Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge
2000 liters capacity PVC water storage tank roof of 2nd floor
Ground Floor
First Floor
Secound Floor
supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.
Ground Floor
First Floor
Secound Floor
Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge
Ground Floor
First Floor
Secound Floor
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
110mm U-PVC SWR Pipe (Supreme /Ashirvad)
110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)
110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.
580mm size Orissa pan (Hindware/Parryware/Neycer make)
Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connec
tion with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
Supplying all materials,labour,T&P and fixing Flat back lipped wall urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge ( stall urinal)
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge
European water closet with 'p' trap plain (Hindware/ Parryware/ Neycer make)
Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge
Halfpedestal basin(560x450)Hindware No.91049+91115
Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink steel sink Single bowl (Mousumi make)
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
25mmx600mm long CP towel rail
Towel ring
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.
600mmx125mm plate glass shelf with CP/NP guard rails.
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge.
600mmx450mm size B.E mirror (swivelled type)
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
CP soap holder
Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge.
½” x 5” CP Shower (Plaza Deluxe Make)
Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge
Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge
Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site.- 60.12 x 0.15
Supplying all materials, labour, T&P and providing cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge - 60.12 x 0.10
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Ground Floor - 60.12 x 0.10
First Floor - 33.98 x 0.10
First Floor
Second Floor - 10.80 x 0.10
Providing & applying water proofing treatment (Two Component glass fibre reinforced specially formulated acrylic modified, cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent (glass fibre cloth) @ 3Kg/Sq.mtr before one coat of Sika Top Seal 109 hi or equivalent Primer @ 200 gm/Sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T&P,
Ground Floor
First Floor
Second Floor - 10.80 x 0.10
Second Floor
Ground Floor
First Floor
Second Floor - 10.80 x 0.10
Supplying all materials, labour, T&P and providing and fixing Vitrified tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed
Ground Floor
First Floor
Second Floor - 10.80 x 0.10
with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge ) Kajaria/Somany/Johnson tile 60cmx60cm
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 650kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. of make Rajshri Plastiwood/ Alstone/Aramstrong or euivalant as per direction of Engineer-in-charge. 27 x 0.76 x 2.13
Factory made Solid WPC door frame of size 90mmx45mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification. of make Rajshri Plastiwood/ Alstone/ Aramstrong or euivalant as per direction of Engineer-in-charge. 27 x 5.02
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge
100mm dia P.V.C. pipe (Type C - 1)
150mm dia P.V.C. pipe (Type C - 1)
Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification.
MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
1 No 100 Users R.C.C.Septic tank
First Lift
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
Second lift
Supplying all materials, labour, T&P and providing cement concrete ( 1:3:6) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.In ground floor
Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -chargeIn ground floor
Supplying all materials, labour, T&P and providing cement concrete M 30 with 20mm and down graded size crusher broken hard granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Base slab
Supplying all materials,labour,T&P and providing 6mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Roof slab
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge in ground floor
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Construction of 20000 Liters RCC Under ground Reserver of Inside size- 4.00 X 3.00 X2.00m
Supplying all materials, labour, T&P and providing,fitting and fixing 160mm x 160mm x 100mm UPVC SWR Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm si
ze h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge
Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department. UGR - 1x5.00x4.00x1.50
-do- with Ist additional depth of 1.50 m over the initial lead and lift UGR - 1x5.00x4.00x0.50
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. UGR - 1x5.00x4.00x0.15
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge UGR - 1x5.00x4.00x0.15
Supplying all materials, labour,T&P and providing cement concrete M 30 for RCC work using 20mm and down graded size crusher broken HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete.
Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. @ 100 kg / cum =
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.
RCC floor roof, chajja etc
RCC Beam, Column, wall etc
RCC Plinth bend/ Raft
Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) over CC work including watering curring and conveyance of all materials to site.
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
Providing fitting and fixing CI/MS step iron including fixing to wall etc. complete
Providing fitting and fixing RCPC cover etc complete as per direction of Engineer-in-charge
RAIN WATER HARVESTING SYSTEM(PIT)(2 nos)
Earth work in hard soil or gravelly soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge.
Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning and bitumen painting over top of wall including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs, landings, balconies, projecting sunshades and
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floorSlab
providing and filling filter media40mm Boulder-
providing and filling filter media20mm Boulder-
Course sand-
Sinking of tube well(200) for PIT
Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
Drilling of 200mm dia bore - 0 mtr to 50 mtr
Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials.
200mm dia PVC pipe
cost of 200mm pvc pipe ASTMD-1785/89 Sch - 80 PVC pipe
providing and filling filter media40mm Boulder-
Cutting slot in casing pipe for recharge of rain water
Course sand-
labour for packing gravel outside the tube well
Construction of 1 no production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories
Cost of washed gravel
Drilling of 200mm/150mm dia bore 00 mtr to 100mtr
Lowering of 200mm dia P.V.C casing pipes 00 mtr to 30 mtrs
Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department)
Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in
order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber 'O' ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length . cost of 200mm dia ASTMD - 1785/89 sch-80 PVC pipe
Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH Rig
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make)
1 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100% standby)
DOL Control panel
40mm dia steel short piece
Well cap
50mm size CI bracket
20mm dia rigid UPVC pipes
Steel rope with cover
Labour charges for lowering including transportation
Supplying filling in F&P with sand including watering, ramming, poking & compacting including Cost, Conveyance, Royalties and Taxes of all materials and cost of all labour with T&P required for the work etc. complete as directed by Engineer-in-charge.
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floor using cement, 4 cm. size black hard crusher broken granite stone metal, screened and washed sharp sand for mortar of approved quality from approved quarry, including hoisting, lowering, laying concrete , ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15cm. thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost of all labours, sundries, T&P required for the work including shoring, shuttering and dewatering, hire & running charges of water pump complete if required as per instruction of the Engineer-in-Charge.
Filling in foundation, plinth and other low laying area with excavated materials including cost of all labour, T&P etc compete including watering and ramming as directed by the Engineer-in-charge.
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge 32mm HDPE pipes (Finolex/Supreme make)
LANDSCAPING WORK (HARD)
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300mm, removal of stumps of trees cut earlier and disposal of serviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 100 metres including removal and disposal of top organic soil not exceeding 150mm in thickness.
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.Excavation up to 1.5m height
Providing, lifting, hoisting and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading. unloading, royalties, watering and curing for the required period, T&P, hire & running charges of concrete mixer and vibrator, cost of admixturs in recommended proportions (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. as per direction of the Engineer-in - charge but excluding the cost of steel reinforcement. FOUNDATION
LANDSCAPING WORK (HARD)
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300mm, removal of stumps of trees cut earlier and disposal of serviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 100 metres including removal and disposal of top organic soil not exceeding 150mm in thickness.
Drainage footing
RCC Drain Slab
RCC Drain Wall
Drainage Footing
Providing & fixing TOR Fe-500 reinforcement bars (make of sail, Tata) for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding welding, joining (if necessary) and placing in position as per the approved design & drawings including cost, conveyance and taxes of reinforcement bars or tor steel and binding wire of 18 to 20 gauge and labour required for the work in all heights as per the specification & direction of E-I-C (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement. Reinforcement Ground Floor
Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018.
INTERNAL ELECTRICAL
A.Sub-Head I (modular Wiring Items) OSR-2018
1.Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. 1.1 MODULAR
a-1)GROUP-A 1.1.1 M
a-2)GROUP-B 1.1.2 M
a-3)GROUP-B 1.1.3 M
b)Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
c)Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
d)Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all requir
ed accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
e)Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
f)Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (flame retradant type) with suitable size modular box & metallic cover plate (both side)( falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
2.a)Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
2.b)Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
2.c)Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
2.d)Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
2.e)Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4)
2.f)Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
3.Supplying and fixing of following sizes of HMS PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak/Kinjal.(Only for data, telephone, CCTV)
4.Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
3.Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with alum
2.Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
1.Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
B Sub-Head II (Light fitting Fixture & Fan)
6.S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
5.Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider (Zencelo)/ legrand( ( Myrius)) /Panasonic (vision)as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
inium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)
9.S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision))
8.Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
7.SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
6.SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
5.Supplying an fixing of recess/surface mounted 2'x2' 25 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years.
4.Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
C BDBS,DB,AC DB,FLOOR PANELS,MCBS
1.Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
a)4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years (FOR LIGHT,ComputerDB)
b)8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years (CONFERENCE ROOM)
c)Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
2.Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year..
3.Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
4.Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year.
5.Supplying and fixing 63Amps 4P 415 volts MCB 415 volts, C series,10KA breaking capacity, Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 years.
6.Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year.
7.Supplying and fixing 40 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year.
D (Earthing) INSTALLATION
1.Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
2.Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. Tapping from 50mm x 6 mm bus bar to all sub panel
3.Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. 2 runs from main LT room to electrical shaft upto 5th floor
e)CABLING AND END
TERMINATION MAIN AREA
1.Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge.
a)3.5core x 240 sq mm FOR TRANSFORMER
b)3.5core x 150 sq mm FOR DG
c)3.5core x 50sq mm FDB POWER
e)3.5core x 25 sq mm FDB LIGHT
2.LAYING OF CABLE
2.1Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
2.2Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
2.3Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 120 SQ. MM but not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
2.4Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
2.5Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
2.6Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge.
2.7Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
2.8Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
2.9Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
2.10Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
3.Supplying and making end termination with brass double compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
3.5 core x240 sq mm
3.5 core x50 sq mm
3.5 core x25sq mm
4.Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
a050 mm dia
5.Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
a)200 mm dia
F PANELS
1.MAIN CONTROL PANEL AT SERVICE AREA S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint fallowed by 9 tank acid treatment is designed as G.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.60X10MM Separate Aluminium Earth bus bar should be installed.
a)In commer-1-01 number of 400(250-400) 4P Icu=100%Ics,36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula
b)In commer-2-01 number of 200A(160-200) 4P Icu=100%Ics,25kA LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
c)In commer-2- 01 no of 200A 4P onload changeover switch (160 KVA DG 01 NO)(Make-C&S/LK(L&T)/Siemens/Schneider/ABB)
d)Busbar-1&2 04 numbers of 500Amps COPPER busbar with busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing)
e)Out going- 03 numbers of 100A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
f)Out going- 06 numbers of 63A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
g)Out going- 4 numbers of 40-63A rating,10 KA breaking capacity,C series, 4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB sb200)
h)Outgoing-01 number of 200A(160-200) 4P Icu=100%Ics,25kA LSIG MCCB with TMR Release ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
i)Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
j)(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.
k)1 no. 3P+N 65kA type 1+2 SPD with 63A rating,10KA breaking capacity ,4P MCB(Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200)
2.FLOOR PANEL POWER 1F,2F,3FS/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.
f)Out going- 06 numbers of 63A 4P MCCB,,25Ka MCCB withTMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula)
In commer - 01 no 100A 4P MCCB 25kA, with ROM & S. Link. withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) (Icu=100%Ics)with shunt trip.
Busbar- 04 numbers of 250Amps, Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
i)Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse.
j)(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.
Out going- 04 nos 63A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
Out going- 02 nos 63A 2P MCB 10kA,C ,240V series . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
(ii) 01 set of MFM with CTS.(DIGITAL)(Sicure/L&T,CT-KAPPA or equievalant make & model)
3.FLOOR PANEL LIGHT S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.
In commer - 01 no 63A 4P MCCB 16kA, with ROM & S. Link. withTMR based release with adjustable overl
j)(ii) 02 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication with RS 485 COMPACTIVITY FOR bms data.
oad ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) (Icu=100%Ics)with shunt trip.
Out going- 04 nos 40A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
Out going- 04 nos 32A 2P MCB 10kA,C ,240V series . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
4.UPS PANEL S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. BUILDING VRF AC)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list. Type 2 SPD 3P+N 40kA shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed.
In commer - 01 no 63A 4P MCCB 16kA, with ROM & S. Link. withTMR based release with adjustable overload ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) (Icu=100%Ics)with shunt trip.
Busbar- 04 numbers of 250Amps, Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
Out going- 04 nos 32A 4P MCB 10kA,C series,415V . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(UPS BDB EACH FLOOR)
Out going- 04 nos 32A 2P MCB 10kA,C ,240V series . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200
Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse.
G CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER
1.Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
2.Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge.
3.Supplying,fixing of FLOOR RACE WAY WITH JUNCTION box GALVANIZED(GC) type AS PER EN-ISO-1461 , with internal dimensions of size 38mm(H) x 225mm(W), of MAKE- Profab/OBO/Neidax .(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge.
LIGHTENING PROTECTION SYSTEM OF NEW OFFICE BUILDING OF NAC CHATRAPUR
Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent
Supply of Roof conductor holder SS Conductor holder with bottom section & conductor holder (v2a) bottom section with 8.5mm dia slot. as per direction of engineer in charge.Make-OBO/Dehn/ABB/Equivalent.
Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB/Equivalent
Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent
Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB/Equivalent
Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent
Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO/Dehn/ABB/Equivalent
Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB/Equivalent
Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO/Dehn/ABB/Equivalent
Supply of universal clamp made of SS to connect rod with flat conductor Make-OBO/Dehn/ABB/Equivalent
Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB/Equivalent
Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO/Dehn/ABB/Equivalent
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
EXTERNAL ILLUMINATION OF NEW OFFICE BUILDING OF NAC CHATRAPUR
Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge.
Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
ELV SYSTEM OF NEW OFFICE BUILDING NAC CHATRAPUR
Subhead- 1 (Lan System)
SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,
Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit
SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
SITC of Cat6 I/O with Single Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit
1mtr Length
2mtr Length
SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand
SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19” ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit
SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
SITC of 1G-LX/LH SFP transceiver module,. Make: Cisco, Digisol, Netgear
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002
incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
Subhead - 3 (IP-CCTV System)
Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR Fixed Lens Dome/Bullet Camera, 1/2.8" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 2 IR LEDs, Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265, H.264 & MJPEG , Fixed Lens 2.8mm, Field of View FoV H:90°, V:62°, BLC, HLC, WDR, 3DNR, White Balance - Auto/Manual, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, Defog, HTTPS, IP Filter, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 2-Way Audio Full Duplex Line IN/Out, 256GB SD card support, Alarm: 1In/1out, PoE (802.3 af) and 12V DC, Max 5W, IP 66/67 & IK10 with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant,, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA compliant. Make-Honeywell(Series 20), Pelco, Axis
Supply, Installation, Testing & Commissioning of 5MP IP Network TDN Low-Light IR motorized Lens Bullet Camera, 1/2.8" CMOS or better, 5MP (2592 x 1944) @ 25fps or better, triple stream at various resolution & Frame Rates, Min. Illumination required 0.007 lux (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG , Triple stream, Fixed Lens 2.8mm, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Video Motion Detection, Tampering, Loitering, Intrusion, & People Counting, 4 Privacy Mask, 8 Region Of Intreset, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, Dual channel Audio, Alarm: 1In/ 1out, 256GB SD card support, PoE (802.3 af) and 12V DC, Max 6W, IP 66, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, CE (EN 50130-4), FCC Part 15, EN 55032 & RoHS (EN63000)/NDA compliant. Make-Honeywell(Series 20), Pelco, Axis
Supply , Installation, testing , commissioning of 32 Channel NVR with 4 SATA; 384 Mbps incoming bandwidth, Up to 8 Megapixels Resolution Display and Recording, H.265 video compression technology with real time encoding, Full function CMS (Central monitoring software) supported, Two way audio supported, Dual streaming technology to encode recording stream and network stream separately, Supports remote monitoring on Mobile Client (Android, IOS), TCP / IP, PPPoE, DHCP, DNS, DDNS, UPnP, NTP, SMTP, Time/ Date, Alarm, Motion Detection & Exact Search (accurate to second), Record Snapshot, FTP, Preset Calling, Email notification supported, Manual/ Alarm/ Motion Detection/ Continuous, CE, FCC, RoHS). Make-Honeywell series 20/Pelco/Axis
Supply, Installation,Testing & Commisioning of Surveliance 10 TB HDDMake:- WD/Segate/Toshiba
SITC of Certified HDMI® Interface Cable, 18 Gbps, 15 m Makes: Honeywell, Extron, Kramer
SITC of 55" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
UPS SYSTEM OF NEW OFFICE BUILDING OF NAC CHATRAPUR
Supply ,installation ,testing & commissioning of 10KVA UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sequence corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 100AH, 40 No.s) protection for fault by OL,UV,EF,GF,OC,Ph. (Make:Numeric/APC/ Vertiv/) LOAD OF computer,emergency) as per direction of Engg.-in-Charge. Warranty period of all accessories & component & system must be 2 years & complete test certificate must be submitted along with ups including component list & SLD.
FIRE FIGHTING WORKS OF NEW OFFICE BUILDING OF NAC CHATRAPUR
A.PUMPS AND APPURTENANCES
Supply , installation, testing & commissioning of Motor driven end suction Back pullout type Centrifugal pump delivering 2280 LPM at 70 Mtr head with CI casing bronze impeller and SS shaft with mechanical seal (for Wet riser & Sprinkler system) with 2 pole TEFC motor suitable for operation on 415 V ,3 ph, 50 C/s AC supply and complying to TAC norms including providing base frame coupling,coupling guard as per direction of Engineer-in-charge (Make:PUMP:KBL/ Grundfos / KSB/ Wilo)
Supply , installation, testing & commissioning of Diesel Engine driven end suction Back pullout type Centrifugal pump having 2280 LPM at 70 Mtr head with CI casing bronze impeller and SS shaft with mechanical seal and suitable diesel engine complying to TAC norms along with all accessories including control wiring between panel & DG set and fuel storage tank including providing base frame coupling,coupling guard as per direction of Engineer-in-charge..(Make:PUMP:KBL/ Grundfos / KSB/Wilo)
Supply , installation, testing & commissioning of Motor driven end suction Back pullout type Centrifugal Jocky pump delivering 180 L
SITC of 55" UHD IPS Commercial Digital Display for Small Size Discussion & Chambers: Brightness (440 nits or higher), Dynamic Contrast Ratio (Dynamic MCI (Hz)):1000000:1), 1000000:1, Static (Panel) Contrast Ratio-1200:1, Response Time (G to G)-8 ms, Refresh Rate.-60 Hz, Life span (hrs)-30,000, Speaker (Sound Output):10W + 10W, Speaker System: 2.0 ch, DVB-T2/C Broadcasting System, Commercial Smart UX, webOS version (webOS 6.0), BIS Certification with 3 years onsite warrenty. Make: LG/Samsung/Sony
Supply & Laying of XLPE power cable of 1.1 KV grade of following size on Cable POLYCAB/KEI/HAVELLS /GLOSTER/FINOLEX/RR KABEL
a) 3C X 70 sqmm
b)3C X 16 sqmm
Cable laying
Laying & fixing of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on Cable Tray as required.
a)Upto 35 Sqmm
b)Above 35 Sqmm and upto 95 sqmm
End Termination
b)3C X 16 sqmm
Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable)
a)3C X 70 sqmm
Supply,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 150 mm NB and IS 3589 for above 150 mm 6mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size including laying in ground after excavation and refilling of trench along with providing 4mm thick pipecoat for underground pipe after applying wrapping coating primer as required as per direction of Engineer-in- charge.Make-TATA/JINDAL/SAIL
b)3C X 16 sqmm
Laying & fixing of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on Cable Tray as required.
B PIPE & VALVES ETC.
Supply,Installation,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 150 mm NB and IS 3589 for above 150 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-TATA/JINDAL/SAIL
Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C.Make-Zoloto/Kartar/Kirloskar/Leader
SITC of CI Gate valves as per IS:14846 and rising sprindle type with flanges, bolts, nuts, washers , gaskets, etc.Make-Zoloto/Kartar/Kirloskar/Leader
Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Make-H.Guru/G.Guru
Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Danfoss/Grundfoss/Indfoss
Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia h
loes with stainless steel flange as required. Make-Zoloto/Kartar/Kirloskar/Leader
Supply,Installation,Testing & Commissioning of Air vessel made of 250mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint as required.
a)150mm NB
b)100mm NB
c)80mm NB
a)200mm NB
Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/Kartar/Kirloskar/Leader
Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
C WET RISER CUM DOWN COMER SYSTEM
Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge.Make-Minimax/Newage/Fireshield/Safex
Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge.
Providing, fitting & fixing of 4-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Karatr/Kirloskar
E EXTINGUISHER SYSTEM
Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge. Make-Safex/Fireshield/Ceasefire
Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire
Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
F AUTOMATIC FIRE ALARMING SYSTEM
Supply, Installation, Testing & commissioning of Addressable Manual Call Point soft addressable type with in built fault isolator as required.Make-Morley IAS/Siemens/Bosch/Edward
Supply, Installation, Testing & commissioning ofAddressable Loop Powered Hooter cum Strobe (sound output of minimum 90db) cum strobe (strength of light 10cd) complete with inbuilt isolator as required. Make-Morley IAS/Siemens/Bosch/Edward
Supply & Fixing of 2 core 1.5 sq.mm, multi strand, copper conductor, FRLS (Fire Retardent Low Smoke)-PVC insulated GI Screened Armoured cable with saddle and required accessories.& Power Cable. Make-Polycab/RR cable/finolex/havells/KEI/Gloster
Supply, Installation,Testing & Commisioning of Microprocessor based Addresable fire alarm control panel , fully networkable with each loop capable of taking 99 devices, 8 line x 40 character alpha- numeric liquid crystal display .The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. The fire alarm panel shall be suitable for software integration with BMS & PA system.Make-Morley IAS/Siemens/Bosch/Edward(2 Loop)
G PA SYSTEM
Supplying, installation, testing & commissioning of 6 zone,voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required .Make. Honeywell/Bose/Bosch
Supplying, installation, testing & commissioning of digital audio amplifier 450Watt, 25V rms operating at 240 Volt AC Supply complete as required. Make. Honeywell/Bose/Bosch
Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/15 Watt in ABS enclosure complete as required Make. Honeywell/Bose/Bosch
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
BOQ_567564.xls
BOQ • 1.08 MB
DTCN.pdf
Tender Documents • 3.86 MB
Download all tender documents and submit your bid