| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAccepted-AOC WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹5.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹5.7 CrRejected-Finance | ₹5.7 Cr | L2 | Rejected-Finance not lowest bidder |
| 3 | L3₹5.7 CrRejected-Finance | ₹5.7 Cr | L3 | Rejected-Finance not lowest bidder |
| 4 | L4₹5.7 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹5.7 Cr | L4 | Rejected-Finance not lowest bidder |
| 5 | L5₹5.8 CrRejected-Finance | ₹5.8 Cr | L5 | Rejected-Finance not lowest bidder |
| Sl No | Description | Qty | Unit | M/S Shiv Shakti Enterprises L1 | M/S RAJ KUMAR GUPTA L6 | RAGHUSONS INFRA ENGINEERING PVT. LTD L4 | S.G.ENGINEERING COMPANY L5 | SREEKRISHNACONSTRUCTIONS L2 | M/s Khanna Enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I | 1 | Lump sum | 68,00,000 ₹68 L | 66,56,000 ₹66.6 L | 65,00,000 ₹65 L | 63,63,000 ₹63.6 L | 61,99,000 ₹62.0 L | 58,14,900 ₹58.1 L |
| 2.00 | Lump sum price worked out by the tenderer for “INTERNAL ELECTRIC SUPPLY WORKS" as listed in Schedule ‘A’ Section - II | 1 | Lump sum | 2,00,000 ₹2 L | 2,31,068 ₹2.3 L | 1,85,700 ₹1.9 L | 1,82,500 ₹1.8 L | 2,20,000 ₹2.2 L | 1,25,000 ₹1.3 L |
| 3.00 | Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III | 1 | Lump sum | 30,000 ₹30,000 | 35,000 ₹35,000 | 32,770 ₹32,770 | 18,300 ₹18,300 | 21,000 ₹21,000 | 20,000 ₹20,000 |
| 4.00 | Lump sum price worked out by the tenderer for “PATH, HARDSTANDING WORKS" as listed in Schedule ‘A’ Section - IV | 1 | Lump sum | 1,35,000 ₹1.4 L | 1,57,500 ₹1.6 L | 1,07,530 ₹1.1 L | 1,09,000 ₹1.1 L | 1,00,000 ₹1 L | 90,661.84 ₹90,661.84 |
| 5.00 | Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Section - V | 1 | Lump sum | 22,000 ₹22,000 | 29,500 ₹29,500 | 20,716 ₹20,716 | 19,800 ₹19,800 | 20,000 ₹20,000 | 15,000 ₹15,000 |
| 6.00 | Lump sum price worked out by the tenderer for “DEMOLITION/DISMANTLING WORKS" as listed in Schedule ‘A’ Section - VI | 1 | Lump sum | 55,000 ₹55,000 | 78,200 ₹78,200 | 97,290 ₹97,290 | 77,700 ₹77,700 | 78,900 ₹78,900 | 1,00,000 ₹1 L |
| 7.00 | Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VII | 1 | Lump sum | 1,00,000 ₹1 L | 1,15,200 ₹1.2 L | 1,07,700 ₹1.1 L | 96,100 ₹96,100 | 95,000 ₹95,000 | 80,438.16 ₹80,438.16 |
| 8.00 | Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - VIII | 1 | Lump sum | 2,50,000 ₹2.5 L | 2,98,500 ₹3.0 L | 1,79,500 ₹1.8 L | 1,91,300 ₹1.9 L | 2,10,000 ₹2.1 L | 2,50,000 ₹2.5 L |
| 9.00 | Lump sum price worked out by the tenderer for “AIR CONDITIONING" as listed in Schedule ‘A’ Section - IX | 1 | Lump sum | 1,80,000 ₹1.8 L | 2,07,335 ₹2.1 L | 1,44,040 ₹1.4 L | 1,99,100 ₹2.0 L | 1,89,990 ₹1.9 L | 1,75,000 ₹1.8 L |
| 10.00 | Lump sum price worked out by the tenderer for “FIRE FIGHTING SYSTEM" as listed in Schedule ‘A’ Section - X | 1 | Lump sum | 2,15,000 ₹2.1 L | 2,46,531 ₹2.5 L | 2,31,770 ₹2.3 L | 2,49,800 ₹2.5 L | 2,25,900 ₹2.3 L | 2,05,789 ₹2.1 L |
Updated dates
Tender Value
₹4.9 Cr
EMD Value
₹5.6 L
Closing Date
14 Jan 2026, 6:00 pmClosed
Chief Engineer Bathinda zone
HQ CE Bathinda Zone, Bathinda Mil Stn-151004
PROVN OF CENTRALISED AC AND ACOUSTIC PANELING FOR AUDITORIUM AT SUTRAGARH MIL STN
2025_MES_742664_1
84553 CE BTZ/SOG/TOKEN-59 OF 2025-26
Open Tender
Miscellaneous Works
365 days
GE (A) Suratgarh
As per NIT
8 documents required · 8 mandatory
₹2,000
Yes
GE (A) Suratgarh
₹5.6 L
Yes
HQ CE Bathinda Zone, Bathinda Mil Stn-151004
27 Jan 2026
3 Dec 2025
16 Jan 2026
3 Dec 2025
14 Jan 2026
31 Dec 2025
3 Dec 2025 - 31 Dec 2025
15 Dec 2025
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIC SUPPLY WORKS" as listed in Schedule ‘A’ Section - II
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III
Lump sum price worked out by the tenderer for “PATH, HARDSTANDING WORKS" as listed in Schedule ‘A’ Section - IV
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Section - V
Lump sum price worked out by the tenderer for “DEMOLITION/DISMANTLING WORKS" as listed in Schedule ‘A’ Section - VI
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VII
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - VIII
Lump sum price worked out by the tenderer for “AIR CONDITIONING" as listed in Schedule ‘A’ Section - IX
Lump sum price worked out by the tenderer for “FIRE FIGHTING SYSTEM" as listed in Schedule ‘A’ Section - X
Lump sum price worked out by the tenderer for “ACOUSTIC PANELING AND TANK STAGING WORK" as listed in Schedule ‘A’ Section - XI
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Section - XII
Sch 'A' Section- XIII, MISC ITEMS
Supply, installation, testing and commissioning of DALI dimmable recess mounted accent light with non-integral fixed output driver having LED light source engine, 12 to 36° beam angle of light source, luminous flux ≥ 2000 lm, rated luminous efficacy ≥ 120 lm/W, 50000 burning hours, power consumption ≤ 20 W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 4000K, colour rendering index (CRI) ≥ 80, Power Factor (fraction) ≥ 0.9, median useful life L70B50 @ Ta = 45 °C ≥ 40000 hrs, surge protection level ≥ 2.5 kV with aluminium alloy housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 240 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia. ≤ 5" (125 mm) and fixture height ≤ 150 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of DALI dimmable recess mounted accent light in fixed type with non-integral fixed output driver having COB type LED, 36° beam angle of light source, luminous flux ≥ 4000 lm, rated luminous efficacy ≥ 120 lm/W, 50000 burning hours, power consumption ≤ 42 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 4000/6500K, colour rendering index (CRI) ≥ 80, power factor (fraction) ≥ 0.9, median useful life L70B50 @ Ta = 45 °C ≥ 40000 hrs, surge protection level ≥ 4 kV with die cast aluminium housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 140-270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia. ≤ 8" (200 mm) and fixture height ≤ 75 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning low height recess mounted downlight in circular form-factor with non-integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 2000 lm, rated luminous efficacy ≥ 120 lm/W, 50000 burning hours, power consumption ≤ 19 W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5 kV with aluminum die cast housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 130- 320 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia ≤ 5" (125 mm) and fixture height ≤ 40 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning low height recess mounted downlight in circular form-factor with non-integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 1500 lm, rated luminous efficacy ≥ 120 lm/W, 50000 burning hours, power consumption ≤ 13.5 W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5 kV with aluminum die cast housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 130- 320 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia ≤ 5" (125 mm) and fixture height ≤ 40 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of surface mounted circular downlight with integral fixed output driver having LED light source engine, luminous flux ≥ 2000 lm, rated luminous efficacy ≥ 120 lm/W, 50000 burning hours, power consumption ≤ 19 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) > 80, SDCM < 5, THD < 10%, Power Factor ≥ 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5 kV with aluminium pressure die cast housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, safety class I, and suitable for mounting on normally flammable surfaces, 220- 240 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, overall diameter ≤ 7" (175 mm) and fixture height ≤ 60 mm along with mounting bracket and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify SM296C LED20S-6500 PSU WH or equivalent model of iGuzzini, Trilux or ENDO Lighting
Supply, installation, testing and commissioning of surface mounted, dust penetration protected, jet-proof LED downlight having LED light source engine, integral driver, luminous flux ≥ 4000 lm (±10%), rated luminous efficacy ≥ 120 lm/W, 50000 burning hours, correlated colour temperature (CCT) 6500K, colour rendering index (CRI) > 80, high-gloss mirror optic, reflector type optical cover, luminaire light beam spread 60°, power factor (fraction) ≥ 0.9, power consumption ≤ 36 W (±10%), initial chromaticity (0.31, 0.32) SDCM < 5, driver failure rate ≤ 1% at 5000 h, median useful life L70B50 50000 hrs, aluminum die cast housing, reflector and optic, IP65 & IK02 protection, safety class I, suitable for input voltage 220 to 240 V and line frequency 50 Hz complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of 4' surface mounted / suspended batten having LED light source engine delivering full window illumination, integral fixed output driver, 120° beam angle of light source, luminous flux ≥ 4000 lm, luminous efficacy ≥ 120 lm/W, power consumption ≤ 34 W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, power factor > 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 4 kV with steel housing, polycarbonate optical cover / lens, IP20 & IK02 protection, and and suitable for mounting on normally flammable surfaces, 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class I safety, along with surface / suspended (asymmetric / symmetric) mounting device and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify BN308C LED40S-6500 L120 PSU WH or equivalent model of iGuzzini, Trilux or ENDO Lighting
Supply, installation, testing and commissioning 4' waterproof surface mounted / suspended batten having LED light source engine delivering full window illumination, integral fixed output driver, SY120° / diffused light distribution, luminous flux ≥ 4400 lm, luminous efficacy ≥ 120 lm/W, power consumption ≤ 37 W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD < 20%, power factor > 0.85, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5 kV with polycarbonate co-extrusion housing, high transmittance PC diffuser, IP65 & IK08 protection, BIS approbation & RoHS sustainability compliance and suitable for 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range -10 to 45 °C, class B serviceability, along with Click Fix mounting bracket and all necessary accessories complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning water-proof wall light (mirror / bathroom light) having built-in water-resistant LED light source, luminous flux ≥ 450 lm, lifetime up to 15000 hrs, power consumption ≤ 8 W, IP44 protection (Class of Protection II- double protection) with electrical connection complete all as specified and directed by engineer-in-charge.
Supply, installation, testing and commissioning neatly designed step light having long life LED source, beautiful light pattern, robust finish, aluminum housing, LED integrated lamp base, luminous flux ≥ 85 lm, initial correlated colour temperature (CCT) 3000K, power consumption ≤ 3 W, IP44 protection with electrical connection complete all as specified and directed by engineer-in-charge.
Supply, installation, testing and commissioning LED strip of dimension 1 mm X 8 mm X 5000 mm (H X W X D) for indirect illumination of false-ceiling coves in officers' chambers having 120° luminaire light beam spread, symmetric optic, luminous flux ≥ 800 lm, luminous efficacy ≥ 105 lm/W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 4000K, colour rendering index (CRI) ≥ 80, SDCM < 5, power factor (fraction) > 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, 2P connection unit and 1P cables without plug, with aluminum housing, IP20 protection, RoHS compliance and suitable for 24 V DC input voltage, ambient temperature range -20 to 35 °C, class III safety, along with all necessary accessories complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of emergency exit sign having 3 hrs duration, LED light source engine with luminaire light beam spread 55°, upward light output ratio 0.01, luminous flux 85 lm, luminous efficacy ≥ 32 lm/W, luminous flux tolerance ±5%, initial chromaticity ≤ 0.33, colour rendering index (CRI) > 80, initial colour rendering index tolerance ±2%, correlated colour temperature 6500 K, standard tilt angle post top 0°, standard tilt angle side entry 0°, power factor 0.4, internal control interface (no external connection), suitable for input voltage 220-240 V at line frequency 50 Hz having initial / average / end CLO power consumption 4 W, inrush current 4 A, inrush time 100 ms, power consumption 4 W, 2 Push-in connector 3-pole connection, lithium battery (LiFePO4) suitable for 4 W power consumption during central DC emergency mode, 85 lm emergency lux, polycarbonate housing, UV stabilized polycarbonate optic cover, having overall dimensions 30 X 186 X 330 mm (H X W X D) complete all as specified and directed by the engineer-in-charge.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium protection stove enamelling rigid steel conduit as per IS 9537 (Part-II): 1981 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
Supply and fix single pole & neutral, modular type, double door, metallic distribution board 18 way conforming to IEC 61439-3, suitable for flush / surface mounting with provision for DP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Note:- MCCB/ RCCB / RCBO / Isolator / MCB shall be measured and paid separately.
S & F triple pole & neutral double door, modular type, PPI DB 04 way, per phase isolation metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Note:- MCCB/ RCCB / RCBO / Isolator / MCB shall be measured and paid separately.
S & F triple pole & neutral double door, modular type, PPI DB 06 way, per phase isolation metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Note:- MCCB/ RCCB / RCBO / Isolator / MCB shall be measured and paid separately.
S & F triple pole & neutral double door, modular type, PPI DB 08 way, per phase isolation metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Note:- MCCB/ RCCB / RCBO / Isolator / MCB shall be measured and paid separately.
S & F triple pole & neutral double door, modular type, PPI DB 12 way, per phase isolation metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Note:- MCCB/ RCCB / RCBO / Isolator / MCB shall be measured and paid separately.
S & F vertical triple pole & neutral, double door metallic modular distribution board 12 Way, conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 160 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 160 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earth bars, cable ties for cable management, pre-fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed by engineer-in-charge. Note:- MCCB / MCB shall be measured and paid separately.
Supply & fix BLDC Wall Mounted fan of 400 mm sweep, 30 W, 230 V, 50 Hz, 1350 revolution per minute, Air delivery: 65 m3/min including remote control complete all as specified and directed by Engr-in-charge.
S & F MCB 10 A, 230 V, 50 Hz, 1P (C Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 16 A, 230 V, 50 Hz, 1P (C Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 6 A, 230 V, 50 Hz, 1P (D Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 16 A, 230 V, 50 Hz, 1P (D Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 32 A, 415 V, 50 Hz, 3P (D Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 40 A, 415 V, 50 Hz, 3P (D Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 40 A, 415 V, 50 Hz, 3P (C Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 32 A, 415 V, 50 Hz, 4P (D Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 40 A, 415 V, 50 Hz, 4P (C Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F MCB 40 A, 415 V, 50 Hz, 4P (D Curve) for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F residual current device (RCD) 16 A, 30 mA, 230 V, 50 Hz RCBO conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected terminals suitable for cable sizes up to 35 mm², colour coded on / off indication on dolly, integrated label holder, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F residual current device (RCD) 25 A, 30 mA, 230 V, 50 Hz RCCB conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected terminals suitable for cable sizes up to 35 mm², colour coded on / off indication on dolly, integrated label holder, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F residual current device (RCD) 25 A, 100 mA, 230 V, 50 Hz RCCB conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected terminals suitable for cable sizes up to 35 mm², colour coded on / off indication on dolly, integrated label holder, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.
S & F moulded case circuit breaker (MCCB) 160 A 415 V 25 kA 50 Hz, four pole, in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instantaneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 25 kA as per IEC 60947-2 complete all as specified and directed by engineer-in-charge.
S & F moulded case circuit breaker (MCCB) 100 A 415 V 25 kA 50 Hz, four pole, in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instantaneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 25 kA as per IEC 60947-2 complete all as specified and directed by engineer-in-charge.
Supply, installation, testing and commissioning 3 channel DALI high frequency ballast controller for T4 / fluorescent / LED lamps with 3# 20A relay, allowing to control up to 192 DALI devices with 3 channels altogether, having DIN-rail mountable integral DALI bus power supply removing the need for an additional external device, programmed to operate automatically isolate the power circuit when all associated DALI channels are at 0%, suitable for 100 to 240 V, 50 / 60 Hz, 1-Ph supply at 0.1 A complete with accessories all as specified and directed by the engineer-in-charge. The DALI high frequency ballast controller shall consist of the following: [i] Control Outputs: 3 X DALI control outputs, each supporting a full DALI universe of 192 channels including backward channel DALI bus power supply [ii] Internal 24 V rated 250 mA Control IO: 1 X RS485 DyNet serial port / DMX, 1 X AUX programmable dry contact input [iii] DC supply 12V @ 200 mA
Supply, installation, testing and commissioning of wall-mounted 6 button keypad, mounted on a 2 module GI box, having front cover with backlight, built-in proximity & temperature sensors capable of automatically adjusting air-conditioning when integrated into the system, loaded icons like presentation scenario / meeting scenario / master on-off, power saving mode, etc. along with an LED indicator for each operation, available with icon labelling customization, having fully programmable options for individual control / group control / scene control / tasks, etc. and suitable for operating on 12 to 24 V DC SELV class II @ 32 / 20 mA from network complete with accessories all as specified and directed by the engineer-in-charge.
Material & Labour for RoHS compliant and UL listed category 6A, 4 pair F/UTP (shielded) LSZH 23 AWG twisted pair cable, having bare copper conductor, polyolefin insulation, LSZH jacket, aluminium / polyester shield (tape), characteristic impedance 100 ±15% Ω , maximum DC resistance 7.8 Ω/100 m, maximum delay skew 45 ns, normal velocity of propagation (NVP) 69%, maximum operating voltage 80 V, segregation Class c, fully compliant with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of fully microprocessor-based, online double conversion, indoor, compact UPS of 30 kVA rating with latest generation 3-level IGBT (high-frequency PWM) inverter bridge technology, connected in parallel to have N+X redundancy up to a maximum of 4 units with built-in isolation transformer, VRLA-AGM lead-acid, sealed, maintenance-free batteries of suitable size and quantity along with mounting rack(s) to provide 60 minutes back up time, connecting cables (for UPS to battery and battery to battery) suitable size, 5” touch-screen display to monitor UPS status in real-time, relay contact board, Modbus RS485, SNMP-ethernet, USB, net interface, configurable acoustic alarms and signals, complete with all necessary components and accessories as specified and directed by the engineer-in-charge. The UPS shall conform to the following specification: [A] General Features [1] Power: 30 kVA [2] UPS Topology: ON LINE- Double Conversion [3] Nominal Apparent Output Power: 30 kVA / 30 kW (unity power factor) [4] Efficiency in Double Conversion Mode: Up to 94% [5] Efficiency of AC to AC conversion in Eco Mode: > 98% [6] UPS Operating Temperature: 0 to 40 °C [7] Relative Humidity (non-condensing): < 95% [8] Degree of Protection: IP20 [9] Audible Noise Level: < 65 dB [10] Electromagnetic Compatibility EMI: As per IEC EN 62040-2 (CE marking) [11] Safety: AS per IEC EN 62040-1 [12] Test and performance: As per IEC EN 62040-3 [13] Accessibility: Front access [14] Installation: Against the wall [15] Front Panel: 5" touch-screen [16] Serial Communication Interface: RS485 (Modbus RTU protocol) [17] Parallel Configuration: Up to 3+1 (redundant parallel) or up to 4 (power parallel)
M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 2.5 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from pipe electrode to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Providing and laying 80 mm thick factory made chamfered edge cement concrete paver block of M-40 conforming to IS 15658: 2021 grade with approved colour, design and pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness, size and shape, made by table vibratory method using polyurethane mould, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand having gradation as per IRC SP 63: 2018 and 2 to 4 mm wide joints filled with fine sand having gradation as per IRC SP 63: 2018, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed.
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 170, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.
Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.
M & L for construction of new valve pit/chamber of size 1200 mm (Length) X 1200 mm (Breadth) X 1200 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed.
Supplying & laying ductile iron specials (class K12 as per IS 9523: 2000) of any type, any radius/ angle, any nominal dia for mechanical and push on flexible joints for cast iron or ductile iron pressure pipe lines complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately.
Supply, testing, commissioning and installing outdoor type compact substation consisting following: - (A) HT SWITCHGEAR: - 11 kV 630 Amps, 21 KA for 03 Sec Non-Extensible Ring Main Unit with metering Panel Compact Switchgear consisting of one number Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst) protection, earth fault protection and thermal overload relay for transformer. Interconnection between HT switchgear and transformer shall be using 1 core x 3 x 95 sqmm aluminium unarmoured XLPE cable (B) Transformer Section:- mineral oil immersed, natural air-cooled, outdoor type, double wound (copper) distribution transformer, three phase, 315 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available.
Supplying, installing, commissioning and testing Silent type Diesel Engine driven Generating Set, radiator cooled, with AMF panel capable of delivering 320KVA or nearest higher rating 415 volts AC 3 phase, 4 wire system of supply, 50Hz. The DG set shall consist of diesel engine coupled through flexible coupling to matching alternator and mounted on foundation pads on common base frame in the CPCB approved acoustic enclosure (the complete set confirming to and test certificate as per latest CPCB norms and as specified) with AMF control panel standardised by manufacturer, inbuilt fuel tank, flexible exhaust pipe, including necessary PCC foundation as per manufacturer instructions complete all as specified and as directed and comprising with the following:-- Engine (Prime mover) : Diesel Engine 1500 RPM of suitable BHP as recommended by manufacturer (at rated RPM), water cooled, 4 cylinder, inline, 4 stroke, performance class of Generator Set ISO 8528-562 as per latest norms with turbo charged air cooled , 1x88 AH 12 Volts batteries start, mechanical FIP, Electronic Governor, pulse tuned exhaust manifold, stainless steel exhaust flexible connection complete with flywheel and all standard fittings/fixture as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp and pressure gauge, water temp starter, dynamo, fuel tank, fuel and lube oil filter, Dry type replaceable paper element air cleaner etc. Alternator: AC alternator, self-excited, self-regulated, self-ventilated, brushless design, confirming to BS 2613/5000, 3 phase, 415 volts, 4 wire, output at PF 0.8, 1500 RPM, insulation class ‘H’ enclosure IP 23 complete with AVR with ± 1% voltage regulation, directly coupled to and matched with engine. Anti-vibration pad for mounting engine alternator assembly on the base frame/plate. Base frame/plate made out of structural steel as per manufacturer’s recommended design/specifications.
Acoustic Enclosure: Engine Alternator assembly mounted on AV mounts with silencer and SS exhaust bellow suitable optimised to meet stringent noise emission standards as laid down by MOEF/CPCB. Base rail with draw out type fuel tank provided with drain plug, air vent, inlet and out let connection, level indicator, manhole etc. 01 No 12-volt x 88 AH maintenance free batteries complete with suitable size copper lead. AMF control panel : RAL 9003 white powder coated control panel made out of CRCA sheet provided with AMF system (automatic starting of main failure) and Start Stop push button for manual operating, provide with MCCB of suitable rating with short circuit protection, controller which display voltage, current, KW, PF, Frequency, KWH, lube oil pressure, indicating lamps for ‘load ON’ and ‘set running’ current transformer of suitable rating etc, aluminium bus bar of suitable rating with incoming and outgoing termination complete all as per manufacturer’s recommended design/specifications. The contractor shall supply following maintenance spare part and tool kit for the generator set: - (i) Fuel filter - 02 Nos (ii) Lube oil filter - 01 No (iii) Air filter - 01 No (iv) V-belt - 02 Sets (v) Tool kit socket set - 01 No (vi) DE Spanner set - 01 No (vii) Ring Spanner set - 01 No (viii) Clamp meter - 01 No Note: - (i) Any item left out for successful operation of AMF panel is deemed to be included in overall cost quoted. (ii) DG set should be sound proof as per latest policy (iii) Cost of maintenance free batteries as per recommendations of manufacture shall deemed included in unit rate quoted by contractor (iv) Cost of PCC foundation as per recommendations of manufacturer shall deemed included in unit rate quoted by contractor. (v) Initial filling of lubricating oil/coolant and fuel required for testing of DG set shall be provided by the contractor without any extra cost. (vi) Exhaust from DG set shall be as per latest CPCB IV norms. Alternatively, emission control device within overall cost quoted shall be provided (vii) Pre commissioning test shall be carried out by rep of Accepting Officer. All necessary equipment’s, consumables and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor. (viii) Contractor shall produce test certificate of DG set; no payment shall be allowed without test certificate.
Designing, manufacturing, supplying, fixing, erecting, testing and commissioning LT APFC panel with capacitor bank, conforming to IS 16636: 2017, 150 kVAR, outdoor installations, rated system voltage of the panel 440 V ± 10%, rated frequency 50 Hz, 3 phase, 4 wire, delta connected, rated impulse withstand voltage 8 kV, free standing, pedestal mounted, made of cold rolled close annealed sheet of minimum 2 mm thick for the load bearing structure and minimum 1.6 mm thick for door and partition, 50?C ambient temperature, IP 54 Ingress Protection, 800 Amp rated copper busbar, metallized polypropylene (MPP) dielectric type, resin filled box type, self-healing type, shunt capacitor as per IS 13340: 2012, switching configuration: 50 kVAR X 2 Nos + 25 kVAR X 1 No + 10 kVAR X 2 Nos + 5 kVAR X 1 No (total six steps), suitable protection in line with IEC and IS for overheating, over current, earth fault, over voltage, short circuit, thermal overload and over pressure, suitable size power and control cable as per Indian Standards, powder coated in grey colour, including microprocessor based automatic power factor correction controller with human machine interface, cooling fans, capacitor duty contactors, 7% detuned reactors, two earth terminals in the panel and as per the details mentioned below complete all as specified and as directed. and shall be including the followings: - (A) INCOMING: (i) MCCB rated current(In): 400A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, suitable for 415 V, 50 Hz AC supply – 1 No (ii) Microprocessor based automatic power factor correction controller (minimum 6 steps)- 1 No (iii) Cooling Fans to be provided for forced cooling (B) OUTGOING: (a) (i) 5 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 15A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 5 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 5 kVAR 7% detuned reactor copper wound – 1 No
(b) (i) 10 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 2 Nos (ii) MCCB rated current(In): 20 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 2 Nos (iii) 10 kVAR capacitor duty contactors – 2 Nos (iv) ON indication lamp – 2 Nos (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 4 Nos (vi) 10 kVAR 7% detuned reactor copper wound – 2 Nos (c) (i) 25 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 1 No (ii) MCCB rated current(In): 50 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 1 No (iii) 25 kVAR capacitor duty contactors – 1 No (iv) ON indication lamp – 1 No (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 2 Nos (vi) 25 kVAR 7% detuned reactor copper wound – 1 No (d) (i) 50 kVAR MPP dielectric type, resin filled box type, self-healing type, shunt capacitor- 2 Nos (ii) MCCB rated current(In): 100 A, ultimate short circuit breaking capacity (Icu): 36 kA, service short-circuit breaking capacity (Ics): 100% of Icu, impulse withstand voltage (Uimp): 8 kV, insulation voltage (Ui): 690 V, utilization category: A, pollution degree 3, degree of protection: IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, three pole, suitable for 415 V, 50 Hz AC supply – 2 Nos (iii) 50 kVAR capacitor duty contactors – 2 Nos (iv) ON indication lamp – 2 Nos (v) 230 V AC ON, OFF push button with 2NO + 2 NC – 4 Nos (vi) 50 kVAR 7% detuned reactor copper wound – 2 Nos Note: (a) The kVAR rating of capacitor mentioned is for rated voltage of 440 V. However, the capacitor shall be provided for rated voltage of 480 V by enhancing the kVAR rating suitably.
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 125 mm, minimum inside dia 94 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.
M & L for earthing complete with galvanised steel pipe electrode 40 mm nominal bore, medium grade, 2.5 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from pipe electrode to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Supplying, installing, testing and commissioning of Mono-bloc centrifugal chilled water pump (2 W), factory mounted on a common base with electric motor for recirculation of water for the central air conditioning system. All pumps shall be provided with bronze impeller and mechanical seal aligned properly as required. The pump motor shall be suitable for 415 +1-10% volts, 50 cycles, 3 phase power supply. The quoted price shall include cost of thermal insulation and cladding of chilled water pumps including following: - Flow: 144 USGMP Head: 24-27 m (As per actual calculation of pressure drop) Casing: Cast Iron Impeller: Bronze Shaft: Stainless Steel
Supply, Installation, Testing & Commissioning of Hi- wall Split Hydronics unit having below features : - i. Cooling Capacity 24000 BTU/HR ii. Air Flow ( High/Med/Low) - 700/580/355 CFM. iii. 2 RWD cooling Coil. iv .Multi-function LED display. v. 3 Speed Control. vi.2/3-way electromagnetic valve. vii. Multi pipe connection directions to meet varies installation rooms. viii. LCD display on remote control. ix. Air cleaning devices and high efficiency filter keep the air clean x. Ball valve in supply and return water line shall be provided.
Supply, Installation, Testing and commissioning of factory built floor mounted out door type chilled water double skin type horizontal air handling unit 16000 CFM , 65 MM SP , 8 Row deep Cooling Coil, 37 TR Coil Capacity , Mixing Box , Weather proof canopy (for chilled water centralized AC plant) made of 40±2 mm thick panels consisting of pre practised G.I. casing of thickness 0.8 mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tube thickness not less than 0.5 mm) cooling coil of following row deep, filter section with 50 mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE 3 suitable for 415 ± 10 % volts, 50 Hz , 3 Phase AC supply suitably designed for variable frequency drive applications, drain connections, stainless steel (18 G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.) and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specifications and of following capacities. Note : AHU will have Weather proof canopy, Mixing Box for Return air connection.
Supply, laying, connecting, fixing and testing of Chilled/Hot water MS ERW class "C" pipe 100 mm Dia Pipe with 25 mm thick insulation complete with all fitting duly insulated as mentioned therein for closed cell elastomeric insulation 30 to 40 kg /cum density & 26 G Aluminium cladding laid underground / floor etc complete all as specified and directed.
Supply, laying, connecting, fixing and testing of Chilled/Hot water MS ERW class "C" pipe 80 mm Dia Pipe with 25 mm thick insulation complete with all fitting duly insulated as mentioned therein for closed cell elastomeric insulation 30 to 40 kg /cum density & 26 G Aluminium cladding laid underground / floor etc complete all as specified and directed.
Supply, laying, connecting, fixing and testing of Chilled/Hot water MS ERW class "C" pipe 40 mm Dia Pipe with 25 mm thick insulation complete with all fitting duly insulated as mentioned therein for closed cell elastomeric insulation 30 to 40 kg /cum density & 26 G Aluminium cladding laid underground / floor etc complete all as specified and directed.
Supply, laying, connecting, fixing and testing of Chilled/Hot water MS ERW class "C" pipe 32 mm Dia Pipe with 25 mm thick insulation complete with all fitting duly insulated as mentioned therein for closed cell elastomeric insulation 30 to 40 kg /cum density & 26 G Aluminium cladding laid underground / floor etc complete all as specified and directed.
Supply, laying, connecting, fixing and testing of Chilled/Hot water MS ERW class "C" pipe 25 mm Dia Pipe with 25 mm thick insulation complete with all fitting duly insulated as mentioned therein for closed cell elastomeric insulation 30 to 40 kg /cum density & 26 G Aluminium cladding laid underground / floor etc complete all as specified and directed.
S & F 100 mm butterfly valve of PN-16 rating having Cast iron body, SG iron disc & AISI 410 shaft along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be applied.
S & F 80 mm butterfly valve of PN-16 rating having Cast iron body, SG iron disc & AISI 410 shaft along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be applied.
S & F 40 mm butterfly valve of PN-16 rating having Cast iron body, SG iron disc & AISI 410 shaft along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be applied.
S & F 100 mm balancing valve of PN-16 rating having Body: CI: IS: 210 FG:220, Bonnet: SG Iron IS:1865 GR 420/7, Seat: Nitrile/EPDM, Stem: AISI 410// Disc: EN3 along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be apply.
S & F 80 mm balancing valve of PN-16 rating having Body: CI: IS: 210 FG:220, Bonnet: SG Iron IS:1865 GR 420/7, Seat: Nitrile/EPDM, Stem: AISI 410// Disc: EN3 along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be apply.
S & F 40 mm balancing valve of PN-16 rating having Body: CI: IS: 210 FG:220, Bonnet: SG Iron IS:1865 GR 420/7, Seat: Nitrile/EPDM, Stem: AISI 410// Disc: EN3 along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be apply.
S & F 80 mm Dual Plate Check valve of PN-16 rating having Body Cast Iron, Disc SS-304 along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be apply.
S & F 80 Y-Strainer of PN-10 rating having Body: Cast Iron/MS fabricated, Screen: SS-304, End Connection: Flanged End Connection along with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be apply.
S & F 80 mm 3-Way valve of PN-10 rating along actuator, Thermostat & transformer with all necessary fittings like flange, nut bolts, Gasket etc. After fixing of valve insulation of pipe thickness along with 26 G aluminium cladding shall be apply.
S & F automatic Air pressure valve of 15 mm complete all as specified and directed.
S & F ball valve 20 mm complete all as specified and directed.
S & F ball valve 15 mm complete all as specified and directed.
S & F strainer 20 mm complete all as specified and directed.
S & F strainer 25 mm complete all as specified and directed.
S & F strainer 32 mm complete all as specified and directed.
S & F dial type pressure gauge complete all as specified and as directed by Engineer-in- charge.
S & F temperature gauge complete all as specified and as directed by Engineer-in- charge.
S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.
S & F water flow switch complete all as specified and as directed by Engineer-in- charge.
Supplying & installing 450 mm x 50 mm x 2 mm perforated Galvanised Iron cable tray with perforation more than 17.5 % in convenient sections, joined with connectors, suspended from ceiling with GI suspenders including GI Bolts & nuts etc. as required complete all as specified and as directed.
Supplying & installing 300 mm x 50 mm x 1.6 mm perforated Galvanised Iron cable tray with perforation more than 17.5 % in convenient sections, joined with connectors, suspended from ceiling with GI suspenders including GI Bolts & nuts etc. as required complete all as specified and as directed.
Supplying & installing 150 mm x 50 mm x 1.6 mm perforated Galvanised Iron cable tray with perforation more than 17.5 % in convenient sections, joined with connectors, suspended from ceiling with GI suspenders including GI Bolts & nuts etc. as required complete all as specified and as directed.
Material and labour for MS iron for support & Expansion tank stand including one coat of red oxide & one coat of black paint complete all as specified and as directed by Engineer-in- charge.
Material and labour for hydronic balancing of HVAC Equipment water flow by NEBB Certified agency. Contractor has to submit the NEBB certificate before starting of work complete all as specified and as directed.
Modification of Site fabricated GI sheet metal ducts of 24 gauge and zinc coating not less than 120 g/m2 in accordance with approved drawings including necessary hangers, rubber gaskets, rivets, flanges, scaffolding required for work, etc., all as specified and/or directed etc., complete all as specified and as directed. Note: 1) The rate quoted for the GI ducting shall be including the cost of scaffolding, steel supports, nuts, bolts, etc. and the same will not be measured and paid separately
Modification of Site fabricated GI sheet metal ducts of 22 gauge and zinc coating not less than 120 g/m2 in accordance with approved drawings including necessary hangers, rubber gaskets, rivets, flanges, scaffolding required for work, etc., all as specified and/or directed etc., complete all as specified and as directed. Note: 1) The rate quoted for the GI ducting shall be including the cost of scaffolding, steel supports, nuts, bolts, etc. and the same will not be measured and paid separately
Modification of Site fabricated GI sheet metal ducts of 20 gauge and zinc coating not less than 120 g/m2 in accordance with approved drawings including necessary hangers, rubber gaskets, rivets, flanges, scaffolding required for work, etc., all as specified and/or directed etc., complete all as specified and as directed. Note: 1) The rate quoted for the GI ducting shall be including the cost of scaffolding, steel supports, nuts, bolts, etc. and the same will not be measured and paid separately
Providing and laying thermal insulation for supply/Return air ducts with 25 mm thick self-adhesive closed cell elastomeric (nitrile rubber) sheet or closed cell physically crosslinked polyolefin foam fixed with adhesive (Armaflex 520 or equivalent) for insulation & finally wrapped with Fiber glass cloth & two coat of UV paint (Star bond) suitable for extreme weather complete all as specified and as directed by Engineer-in- charge.
Providing and laying acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation of thickness not less than 15 mm, density of open cell nitrile rubber insulation shall not be less than 130 kg/m3 including adhesive or density of open cell physically crosslinked polyolefin foam shall not be less than 25 kg/m3 including adhesive (Armaflex 520 or equivalent) for insulation suitable for extreme weather, fixing accessories all as specified and/or directed etc., complete. Note : Acoustic insulation shall be applied inside plenum & duct upto 6 mtr in length.
Supplying, installation, testing and commissioning of GI volume control dampers as per specifications complete all as specified and as directed by Engineer-in- charge.
Supply, erection, testing, balancing and commissioning of aluminium powder coated Supply air grill (without volume control dampers) as per requirement /approved drawings including fixtures, gasket, screws etc. complete all as specified and as directed by Engineer-in- charge. Make : Servex/Caryair/Airflow
Supply, erection, testing, balancing and commissioning of aluminum powder coated return air grill (without volume control dampers) as per requirement /approved drawings including fixtures, gasket, screws etc. complete all as specified and as directed by Engineer-in- charge.
Supply, Installation, Testing & Commissioning of motorized combined fire damper complete with control panel, inter connecting wiring at location shown in approved shop drawing complete all as specified and as directed by Engineer-in- charge.
Supply, Installation, Testing & Commissioning of actuators complete all as specified and as directed by Engineer-in- charge.
Supply, Installation, Testing & Commissioning of control panel and wiring complete all as specified and as directed by Engineer-in- charge.
Supply, fabrication, installation and testing of flexible connection constructed of fire-resistant double resin sleeve as per approved shop drawings and specifications, complete all as specified and directed.
Supplying, installation, testing and commissioning of 320 mm dia Jet diffuser with volume control dampers for supply air as per specifications, complete all as specified and directed.
Supplying, installation, testing and commissioning of GI volume control dampers as per specifications, complete all as specified and directed.
Supplying, fixing, testing and commissioning of powder coated extruded aluminium section fresh air grill in weather maker room with volume control dampers, bird screen etc complete all as specified and as directed by Engineer-in- charge.
Supply, installation, testing and commissioning of HDPE expansion tank of size 1000 Ltrs complete with suitable FR-XLPE/XPE 13 mm thick of minimum bulk density 28 + 4Kg/cum covered with vapour barrier and finished with 0.5mm thick aluminium cladding applied with rubber based adhesive recommended by OEM complete with air vent and drain connection float valve, quick fill and control valves etc as required all as specified and directed.
Material and labour for making of platform of 2-3 Feet height with brick work , Soil filling & PCC for 3# Chiller, 3 # Pump, Main HVAC panel & Cover shed above the 3 # Pupms. Making of foundation of AHU unit - 2# Breaking of wall and repair it ( Duct & Pipe only) as per the existing site condition including painting etc . complete all as specified and as directed by Engineer-in- charge.
Supply, Fixing, testing & commissioning of M.S. pipe 200 mm dia, Medium grade as per IS:1239 part-1 including all accessories such as flanges, tees, bends, reducers jointing rubber gaskets, nuts & bolts, excavation of all type of earth and making goods the same and painting with the 2 coats of first quality enamel paint on pipe exposed to surface complete all as specified and as directed.
Supply, Fixing, testing & commissioning of M.S. pipe 100 mm dia, Medium grade as per IS:1239 part-1 including all accessories such as flanges, tees, bends, reducers jointing rubber gaskets, nuts & bolts, excavation of all type of earth and making goods the same and painting with the 2 coats of first quality enamel paint on pipe exposed to surface complete all as specified and as directed.
Supply, Fixing, testing & commissioning of M.S. pipe 80 mm dia, Medium grade as per IS:1239 part-1 including all accessories such as flanges, tees, bends, reducers jointing rubber gaskets, nuts & bolts, excavation of all type of earth and making goods the same and painting with the 2 coats of first quality enamel paint on pipe exposed to surface complete all as specified and as directed.
Supply ,installation ,Testing & Commissioning of 200 mm dia C.I Non-Return valve double flanged type with sealing ring of nitrile rubber complete all as specified and as directed.
Supply ,installation ,Testing & Commissioning of 100 mm dia C.I Non-Return valve double flanged type with sealing ring of nitrile rubber complete all as specified and as directed.
Supply ,installation ,Testing & Commissioning of 80 mm dia C.I Non-Return valve double flanged type with sealing ring of nitrile rubber complete all as specified and as directed.
Providing and fixing of cast iron flanged foot valve with nuts, bolts 1.5mm thick CAF gasket complete FITTED WITH STRAINER AND all accessories as per IS :4038 , 200 mm NB complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of C.I full way/BALL VALVE Confirming to IS: 778 class-11of screwed type, 25mm dia complete in all respects complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of single headed stainless steel Landing valve flanged inlet with 63mm. female instataneous outlet conforming to IS-5290 with necessary fittings of ISI Marked complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of FIREhose pipe 63mm(RRL)in 15mtrs. Length confirming to IS:636 type11 of wound with gi wire over S.S male/ female coupling confirming to IS:903 complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of external cabinat fabricated from M.S.sheet of 16 GAUGE 525mmx1050mmx250mm with 4mm glass infront .the cabinat should have provision of 2nos,of hose pipe and one no. of branch pipe complete all as specified and as directed.
Providing & Fixing of swinging type first aid firehose reel with 30mtrs long discharge rubber pipe of 20mm.dia with shut off nozzel of 5mm. dia, CONNECTING PIPE WIRE BRAIDED and M.S fitting complete as required As per IS-884 specification. complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of FIRE brigade inlet valve Four way with non return valve and butterfly valve complete in all respect complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of 1200 mm long cylindrical type air vessel of dia 200mm fabricated with 8mm thick plate suitable for12sq/cm.working pressure complete with BALL valve and pressure gauge confirming to IS specification complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of pressure switch along with accessories complete in all respects complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of pressure gauge100mm dial alongwith stop cock with accessories complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of S.S short branch pipe NOZZLE as per IS:903 of ISI MARKED complete all as specified and as directed.
Supply ,installation ,Testing & Commisioning of cubical type foot mounted control panel complete with suitable relays,contractor ,indicating lamps, fuses instruments, isolator automatic star delta type motor starter suitable for main fire pump, jockey pump and deisel engine driven pump confirming to IS:1822 and auxlliary switch including connection complete all as specified and as directed.
Supply, installation, testing and commissioning of air release valve 25 mm gun metal, complete in all respects, as required, specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of Intelligent Addressable Double Action Indoor Application Manual Pull Stations / Manual Call Points suitable for wall/column mounting. MCP shall have red coloured housing with moulded, raised-letter operating instructions of contrast colour. The MCP shall latch mechanically upon operation and shall remain so until manually reset with its key by an authorized operator. The MCP shall have operating temperature range from 0°C to 50°C and humidity tolerance range up to 93% RH, Non-Condensing.as specified and directed by engineer-in-charge.
Providing & fixing of main control panel micro controller based type of min 4 zone "ases" make fitted with automatic battery charger, with lcd display, complete with two numbers of batteries of 12 v each complete all as specified and as directed by Engineer-in- charge.
S & F two core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.
Providing & fixing of M.S pipe 25 mm dia B CLASS, ISI marked, (confirming to IS:1239) including accessories like, bends, Tee, Flanges, Nut bolts, Rubber insertions, cutting, welding & painting etc. complete all as specified and as directed.
Providing & fixing of M.S pipe 32 mm dia B CLASS, ISI marked, (confirming to IS:1239) including accessories like, bends, Tee, Flanges, Nut bolts, Rubber insertions, cutting, welding & painting etc. complete all as specified and as directed.
Providing & fixing of M.S pipe 40 mm dia B CLASS, ISI marked, (confirming to IS:1239) including accessories like, bends, Tee, Flanges, Nut bolts, Rubber insertions, cutting, welding & painting etc. complete all as specified and as directed.
Providing & fixing of M.S pipe 80 mm dia B CLASS, ISI marked, (confirming to IS:1239) including accessories like, bends, Tee, Flanges, Nut bolts, Rubber insertions, cutting, welding & painting etc. complete all as specified and as directed.
Providing & fixing of M.S pipe 100 mm dia B CLASS, ISI marked, (confirming to IS:1239) including accessories like, bends, Tee, Flanges, Nut bolts, Rubber insertions, cutting, welding & painting etc. complete all as specified and as directed.
Providing & Fixing of Brass sprinkler Head PENDENT TYPE of 15 mm Orifice with Taper to operate at 68 C complete all as specified and as directed by Engineer-in- charge.
Material and labour for 40 mm thick brick tiles laid over and including 15 mm thick screed bed with cement mortar 1:6 with WPC and joint grouted flush in cement mortar 1:3 over roof surfaces complete all as specified and as directed by Engineer-in- charge.
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 5000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of Internal Emulsion paint over one coat of alkali resistant primer over one coat of wall care putty to match the existing surfaces complete all as specified and as directed.
M & L for preparation of old surface of wall and applying two coats of Internal Emulsion paint over one coat of alkali resistant primer complete all as specified and as directed.
S & F LED building security light fitting of 25 W pressure die cast Aluminum housing/body, luminous efficacy 120 lm /watt ,50000 burning hour, heat resistant clear toughened glass, better optics for uniform distribution Security luminaire, with driver complete fitting with all accessories including connecting up with three core flexible copper conductor cable with suitable size completes all as specified and as directed
S & F LED flood light fitting 50 W, including driver, luminous efficacy 120 lm /watt ,50000 burning hour all accessories and connecting up with three core flexible copper conductor cable complete all as specified and directed by Engr-in-charge.
Taking down concealed copper/aluminium point wiring (light, fan, socket or power) complete without conduit, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, wall light fittings , tube light fittings, surface light fitting , ceiling light fittings , any types of fittings etc. removing materials to store for keeping in safe custody or for taking on credit and making good disturbed surfaces of walls, floors, etc. to match the existing surfaces complete all as specified and as directed.
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 450mm sweep with blades and frame including new mosquito stainless steel wire mesh of gauge 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners10mm dia100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking out of unserviceable Central Air-cooling plant including motors, air blowers and complete ducting and depositing at AGE E/M store complete all as specified and as directed by Engineer-in-charge.
Supply, installation, testing & commissioning of electrical HW generator equipped with sufficient number of electrical immersion heaters. The pressure vessels shall be constructed and insulated on all sides with 100 mm thick density 48kg/cum fiber glass and cladded with 0.63 mm aluminum sheet in a neat and clean manner. The generator shall be equipped with all automatic and safety controls such as manual reset high temperature water outlet, step controller and recycling relay, 'ON' 'OFF' switch thermostat, pilot light, low water cut off and other controls as per manufacturer’s recommendations. All control and terminals shall be located in an integral control cabinet factory wired and tested. The generator shall be suitable for 415+/- 10 % volts, 50 cycles 3 phase power supply. The entire generator shall be factory assembled and tested at 350 PSI pressure. The hot water generator shall be of 100 KW capacity Multi Heater Bank made of MS sheet and dish end made of MS with heaters arranged in in banks and controlled by electronic controller and thermostat so that hot water is generated at 70 Degree C with nominal variation including necessary controls including inlet and outlet connections for water as per specifications complete with water drain line with necessary fitting, air purging valve on top, pressure release valve, low level cutout, auto vent sight glass foundation for HWG as per specifications complete as required and including connected items required for installations complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Soak Cord, kerfed edge, fabric wrapped magnesite bonded pinewood fiber panel of size 600 x 1200 x 25 mm, for Ceiling, Density 400 kg/cum, weight 10 kg/sqm installed by using strut framework system with non-visible fasteners using Strut H-Spline. The Strut ceiling framework system shall include Strut WC25 wall channel, fully knurled, sectional thickness 0.55 mm, length 3600 mm, unequal flanges of 20 & 30 mm and web of 25 mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300 mm centers. Then suspend strut MC45 main channels, fully knurled sectional thickness 0.8 mm length 3600 mm equal flanges of 15 mm and web 45 mm from soffit at 1200 mm centers with Strut SA25 fully knurled suspender angle with sectional thickness 0.55 mm, unequal flanges of 25 mm & 10 mm. Strut CC 25 cross channel fully knurled, sectional thickness 0.55 mm, length 3600 mm, web 35 mm depth of 20 mm and equal flanges 9.5 mm each fastened to the strut MC 45 perpendicularly at 300 mm centers PVC vinyl core UV treated H spline having sectional thickness 2 mm and length 2400 mm to be fixed perpendicular to the cross channel CC25 at 600 mm centers. The kerfed edge strand ebony panels shall be then inserted into the H spline along their long edge of 1200 mm agist framework to perfect fit with staggered short edge. The system is back lined with acoustical infill Synth PF 10 x 25. Technical parameters: - (a) Fire class – 1 & P (b) Acoustics- NRC 0.95 (c) Thermal conductivity (W/MK) -0.08 (d) Climate (degree Celsius, RH)- 50, 90 (e) Light reflectance – low light reflectivity (f) Green (VoC, RC %)- Low, 30
Supply and fixing Soak Cord, kerfed edge, fabric wrapped magnesite bonded pinewood fiber panel of size 600 x 1200 x 25 mm, for Wall Paneling, Density 400 kg/cum, weight 10 kg/sqm installed by using strut framework system with non-visible fasteners using Strut H-Spline. The Strut ceiling framework system shall include Strut CC50 cross channel having thickness 0.7 mm, length 3600 mm, knurled web 50, depth 50 mm and equal flanges 15 mm each fastened to wall positioned horizontally in a regular manner at 600 mm C/C. H spline having sectional thickness 2 mm and length 2400 mm to be fixed perpendicular to the strut CC50 cross channel at 600 mm centers. The kerfed edge fabric wrapped panel shall be then inserted into the Strut H spline along their long edges of 2400 mm against framework to perfect fit with staggered short edges. Note: - Thickness is given for bare panel. 04 mm for cord fabric (fabric colors as per choice) The system is back lined with acoustical infill Synth PF 10x50 held in position with wire mesh. Technical parameters: - (a) Fire class – 1 & P (b) Acoustics- NRC 0.95 (for 25 mm C50 mounting) (c) Thermal conductivity (W/MK) -0.08 (d) Climate (degree Celsius, RH)- 50, 90 (e) Light reflectance – color dependent (f) Green (VoC, RC %)- Low, 30
S & F 15 mm wash basin mixture, centre hole, mixing hot & cold water, fancy type, cast copper alloy, chromium plated with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe etc and fixed in repairs complete all as specified and directed by engineer in charge.
Subtotal
SREEKRISHNACONSTRUCTIONS (BID ID -3523977)
M/s Khanna Enterprises (BID ID -3524045)
RAGHUSONS INFRA ENGINEERING PVT. LTD (BID ID -3523671)
S.G.ENGINEERING COMPANY (BID ID -3523690)
M/S RAJ KUMAR GUPTA (BID ID -3523358)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
td1.rar
Tender Documents • 8.17 MB
tendercomplete.pdf
Tender Documents • 1.40 MB
td2.rar
Tender Documents • 30.76 MB
BOQ_831636.xls
BOQ • 2.04 MB
drawings.rar
Tender Documents • 2.76 MB
acceptance84553.pdf
Tender Documents • 0.62 MB
Download all tender documents and submit your bid