| 1 | L1₹31.5 LAccepted-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹35.1 L+₹3.6 L (11.5%)Rejected-Finance 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹37.4 L+₹5.9 L (18.7%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹38.4 L+₹6.9 L (21.9%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹38.9 L+₹7.4 L (23.4%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹33.3 L
EMD Value
₹66,600
Closing Date
17 Aug 2022, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
SPECIAL REPAIR FOR REPLACEMENT OF BER DG SET CAP 125 KVA AT TECH AREA SUB STN AND SPECIAL REP REPLACEMENT OF BER CEILING FAN GEYSER EXHAUST FAN ENERGY METER AND COOLING APPLIANCE AT AF STN OJHAR
2022_MES_541995_1
8903/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹66,600
Yes
24 Sept 2022
29 Jul 2022
19 Aug 2022
30 Jul 2022
17 Aug 2022
11 Aug 2022
Amount
Supply, installing, commissioning and testing static Silent Diesel Engine driven generating set capable of delivering 125KVA, 415 volts AC 3 Phase, 4 wire system of supply, 50 HZ at power factor 0.8 minimum, as per IS: 10001/10002 and alternator as per IS:13364 complete with relay panel for automatic starting on mains failure, control panel (AMF) having meters, sound proof canopy and The DG set shall consist of a diesel engine coupled directly to a matching alternator and mounted on Anti vibration pads of approved make on a common base frame and thereafter installed in the CPCB norms approved acoustic enclosure complete with control panel standardized by manufacturer, complete all as specified and directed and shall comprise of the following:- (a) Engine (prime mover) : Directly coupled Diesel engine water cooled suitably de-rated of matching BHP for driving 125 KVA capacity alternator electric start, four stroke designed to run continuously at 1500 RPM confirming to latest IS 10001/10002 , ISO-3046, BS 5514 standerd with an over load capacity of 10% for for one hour in every 12 hrs operation complete with following accessories :- (i) Fly wheel to suit flexible coupling (ii) Flexible coupling with guards (iii) Dry type Air cleaner with filters iv) Lubricating oil filter v) Anti-vibration pad as recommended by manufacturer’s vi) PT/Mico fuel pump with electronic governor of suitable capacity (vii) Self-starter 12 volts DC (viii)Battery chargine alternator (ix) Lead acid storage or dry type battery as recommended by manufacturer along with flexible copper battery lead and connector x) Battery rack made out of MS angle ingle frame as recommended by manufacturer’s (xi) standard safety device as recommended by manufacturer’s (xii) daily service fuel tank for full running capacity of DG set for min 08 hours enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain pug, air vent and locking arrangement’s etc. (xiii) Exhaust system shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and stage for operator.
(xiv) Engine display should have following:- (a) KW, KVA, KWH, KVAR, Power Factor, Phase to Phase & Phase to Neutral Voltage, Ampere etc., (aa) Lubrication oil temperature (ab) Lubrication oil pressure (ac) water temperature ad) Battery voltage (af) Indicator lamp etc (ag) Safety measure :- (i) Low lubricant oil pressure trip (ii) High coolant temperature trip iii) Engine over speed tripiv) Battery charging alternator (v) Emergency stop pressed. (b) Alternator : 125 KVA at 0.8 power factor, self-regulated 3 phase with neutral 415 Volts 50 Hz 1500 RPM , in SPDP enclosure, self-excited & self-reregulated, brush less as per IS 4722, BS EN 60034-1& will be suitable for tropical condition complete with automatic voltage regulator and foot mounted regulator and foot mounted including making cable connection. The salient feature of alternator are as under:- (i) Voltage regulation under static condition + 1.5% (ii) Class 'H' insulation (iii) Permanently lubricating bearing (iv) Capable to make 10% over load for one hour for every 12 hours
(c) AMF Panel as per OEM Recommendation suitable for 125 KVA DG set incl the following AMF control panel factory made, cubical type double door, IP-54 protected floor mounted totally enclosed fabricated out of CRCA seat 3.1MM thick CPRI approved over and including angle made out of 50x50x6mm angle with removable side cover hinged front panel rear panel fpr esay accessibility power coated complete with internal wiring with suitable size copper conductor cable and cable gland for external connection complete suitable for 125 KVA DG set with by pass arrangement including all necessary operating and control device such as contractor, MCCB, volt meter, amp meter, indicating lamp, energy meter with protection fuse for panel instrument battery charges with indicator cut of low and high oil pressure, high speed, over load and earth fault protection, reverse current protection programmable microprocessor based controller with auto manual switch, start/stop control switch with flexible copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufactured Make Kirloskar ,Cummins, Greaves cotton, or as approved Note: rate quoted shall be deemed to include for with suitable auxillaiary contracts, suitable MCB, MCCB, Bus bar, AMF control, control phase fitting control reat, CT, contractor and relay of make L&T are quuavakent as approved, batery charger, hooter part, terminal control, auto MCB, etc mounted inside CPRI approvedcubical typed outdoor LT distributuion panel fabricated out of 3.1.5mm thick CRC seat with seprate looking arrangement, IP54 protected duly painted with expoxy powder quoted over coat of redexide primere factorymade, cubical type, both side openable, air finace for ventilastion and all other auxiliary items required notmentioned here in above but necessary are smooth operation of DG set /AMF panel (complete)
Supply and lay LTcable XLPE insulated screened PVC Bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 V grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core.
Shifting of existing BER D G set 125 KVA ( Floor mounted ) from Tech area sub stn to MES stor Yard (Distance up to 2.0 KM) by disconnection all electrical connection Engr - in- charge. : The rate of T&P (Crane and other eqpt as reqd at site for shifting and loading/unloading are also included in the quoted rates.
M&L for earthing in repair and earthing complete with GI earth plate electrode 600x600x6 mm thick,burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the pl;ate not less than 1.5 Mtr below normal ground level,connected to G I strip 32x6 mm as earth lead by means of bolts,nuts ,washer and check nut of galvanized steel, protected by and including GI pipe 50 mm bore (light grade) and connected to main switch / MCB DBs box point / LP test point as directed and including cement concret pit in 1:2:4 type B1 using 12.5mm graded aggregate, with cast iron miled steel frame embedded in the concrete enclouser fineshed flushed & PCC cover of size (300mmx300mm) all as shown under electrical plate of SSR Pt - I 2009 and as directed including painting the external surface of chamber & cover with enamel paint in diffrent colour as directed and writing earth results & date of test carried out with white paint on black painted background, wiremesh funnel 20 mm bore GI pipe medium grade for watering adequate quantity of charcol and common salt in alternate layer of 15cm 3ft x 3ft thick all around the electrode including necessery excavation & earth work in any type of soil complete testing on completion all as directed. Note:- i) Filling the pit with black cottan soil brought at site. ii) The excavated soil will be removed & paid separtely.Note:-(a).Earth resitance should be less than 5 Ohm up to Warranty period one year. (b).In case earth resitances not found satisfactorily contractor will redo the same earthing.
Supply and fixing ceiling fan complete with blades, down rods, and other connected accessories, 230 Volts, 1200 mm sweep, min air delivery 210CFM in glossy white in colour with service value 6.00 BEE. Five star rated with BLDC motor.Make Havells , Usha, Bajaj, Crompton.
Supply and install testing & commissioning hi wall split Air conditioners with indoor/out door unit with rotary compressor , electric driven single Phase of capacity of 1.5 TR,BEE, 5 star rating, cordless remote control unit with in built air ioniser for better indoor air quality ,inverter type, duly mounted on MS Brackets including copper tubng with insulation for inter connection from out door to indoor unit complete all as specified and directed by Engineer-In-Charge Make :Make LLoyd cat Pt No- GLS18I56WBEL or equivalent in Voltas/Hitachi/ Blue star.
Supply and install testing & commissioning hi wall split Air conditioners with indoor/out door unit with rotary compressor , electric driven single Phase of capacity of 2.0 TR,BEE, 5 star rating, cordless remote control unit with in built air ioniser for better indoor air quality ,inverter type, duly mounted on MS Brackets including copper tubng with insulation for inter connection from out door to indoor unit complete all as specified and directed by Engineer-In-Charge. Make LLoyd cat Pt No- GLS24 I56WBEL or equivalent in Voltas/Hitachi/ Blue star.
Supply and install testing & commissioning Window type Air conditioners with rotary compressor , electric driven single Phase of capacity of 1.5 TR,BEE , 5 star rating cordless remote control unit and with in built air ioniser for better indoor air quality ,inverter type, all as specified and directed by Engineer-In-Charge Make : Voltas/Hitachi/ Blue star.
Supply and fix desert cooler,electric driven (single phase),having nominal air flow capacity of 4000 cum/hr .plastic/ pvc body, complete all as specified& as directed by Engineer-in-charge.Make : Symphony/Bajaj/Usha
Supply and install Frost free refrigerator electric driven single phase 230 Volts capacity 320 litre BEE 3 star rated, Double door, inverter type complete all as specified & as directed by Engineer-in-charge.Make : LG cat Pt No- GLFF343AHGT 1 PB or equivalent Samsung/whirpool/Lloyd.
Supply and install frost free refrigerator electric driven single phase, 230 Volts capacity 300 litre BEE 3 star rated, Double door complete all as specified & as directed by Engineer-in-charge.Make : LG cat Pt No- GL T322SPZX or equivalent Samsung/ whirpool/ Lloyd.
Supply and install Direct cool refrigerator electric driven single phase 230 Volts capacity 210 litre BEE 3 star rated, Single door complete all as specified & as directed by Engineer-in-charge.Make : LG cat Pt No- GL B221APZD or equivalent Samsung/ whirpool/ Lloyd.
Supply install testing & commissioning voltage stabilizer 4 KVA automatic operation,single phase naturally air cooled , digital display , indoor type & designed for input variation betwee 170 to 260 V for output voltage 230 A with +-5% and of capacitycomplete all as specified& as directed by Engineer-in-charge.Make Blue bird/ Volina
SUNIL ENTERPRISE
sapana enterprises
E M CONSTROL SYSTEM
MAHIMA CONSTRUCTION
SHRI SULAI ELECTRICALS
M/s.TIRUPATI BUILDERS
Takshashila electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .