Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹33.7 L+₹1.9 L (6.12%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹34.6 L+₹2.8 L (8.68%)Rejected-Finance 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹34.7 L+₹2.9 L (9.07%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹99,400
Closing Date
3 Jan 2024, 6:00 pmClosed
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
MAINT/REPAIR OF EXTERNAL WATER SUPPLY INSTALLATION AND SEWAGE INSTALLATION AND OTHER MISC WORKS AND REPAIR/MAINT OF HELIPORT LIGHTS ALONGWITH TEXI TRACK OF 660 ARMY AVN SQN (R and 0) UNDER GE NORTH PATIALA
2023_MES_631383_1
GE(N)/TOKEN-77/2023-2024
Open Tender
Civil Works
Item Rate
270 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹99,400
Yes
29 Jan 2024
6 Dec 2023
5 Jan 2024
6 Dec 2023
3 Jan 2024
20 Dec 2023
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm thick, in soft/loose soil complete all as specified and directed.
Removing excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for Sand cushioning for cables complete all as specified and directed .(Note : Punning down thickness shall be measured only.)
Supply and laying un-reiforced precast concret cable cover class LV type-1 Size 250mm X 150mm X 40mm complete all as specified and directed.
Taking out electric cable of any size and description from trenches/ pipe/duct including protection bricks and setting aside for reuse or measurement for credit purpose complete all as specified and directed.
Supplying laying jointing and testing of 16 SQMM PVC sheathed stranded copper conductor single core airport light cable of 5 KV grade conforming to IS 1554 Part-II 1981 complete all as specified and directed.
Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 10 Sqmm 4 core complete specified and directed.(Note –necessary excavation and returning filling ,sand cushioning and bricks protection shall be measured and paid separately under respective item of schedule.
Labour only for removing/refixing AMA LED Elevated Heliport Light and checking serviceability of AMA LED Elevated Heliport Light ,Isolation Transformer and Primary/Secondry connectors with the help of suitable equipment and reassemble the same after replacement of unserviceable componnent and testing complete all as specefied and directed at site by Engr-in-Charge. Note:- Unserviceable components like Isolation transformer,LED Light,Primary connector and Secondry connector will be measured and paid separatly under below mention schedule
Material only for Isolation Transformer 45 Watt, 50 Hz, 5000V grade primery/secondry 6.6 A/6.6A all as specified and directed by Engr-In-Charge Make:- India Isolation Transformer or Equivalent.
Material only for LED Elevated Heliport Light all as per existing installed at helipad make of AMA INDIA complete all as specified and directed by Engr-In-Charge Note:- Prior to placing order for supplyof heliport lights colour of the light will be confirmed from AO/Engr-in-Charge Make:- AMA India
Material only Primary Connector for connection of LED Helipad Light with transformer complete all as specified and directed.
Material and labour for Secondry Connector for connection of LED Helipad Light with transformer complete all as specified and directed.
Supply & Fixing in replacement LED flood Light(used as apron Light) comprising of aluminium die cast body housing,IP 66 with high power LED's as light sourse suitable for architectural features or retail space of capacity 120 Watts (not less than 100 lumen/watt output) inbuilt mounting clamp bracket for mounting flood lights with suitable nut, bolts and washers etc including connecting from pole/box to street light complete all as specified and directed.
Supply and fixing in replacement cable junction boxes IP66 with integrated membrane/metric knockouts for cable entry of size130 mm x 180 mm x 77 mm, all as per Hensel cat part DK1010G of Hensel or equivalent, having arrangement of connecting incoming and outgoing cables including suitable gland of PVC and fixing arrangements with flood lights complete all as specified and directed.
Periodical inspection by qualified team for LED Elevated Heliport Light system complete installed at Patiala cantt incl repair/ replacement of unserviceable/ defective accesories if any and as mentioned below: 1. CCR Panel 8 kVA, Make: NASU systems year of installation 2018 2. Underground cable 16 SQMM PVC sheathed stranded copper conductor single core airport light cable of 5 KV grade: Approx 2400 RM 3. CI housing boxes and LED Elevated Heliport Lights with connected componnents like Isolation transformer,LED Light, Primary connector and Secondry connector: 54 Nos Note 1 : Contractor should inspect the system once in two months or as called upon by Engineer- in -charge. The inspection and repair should incl complete testing of system, rectification of faults occured due to moisture etc incl taping of joints minor repair of the CCR panel. Stores for insulation and water proofing incl tapes, water proofing compound are deemed to be incl in this item. If any Major repair is required the same is to be informed by the contractor alongwith cost to be occured. Unserviceable components like Isolation transformer,LED Light,Primary connector and Secondry connector will be measured and paid separatly. Note 2 : Contractor is advised to visit the complete site prior bidding. Contractor should visit the site upon notification within 24 hrs. Any delay thereafter shall results in penalty of Rs 500/ day.
Material and labour in replacement Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI earth lead of 25x4 mm as earth strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work, GI pipe light grade 25mm/40 mm bore for protection of GI wire /strip from earth electrode supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed
Supply and fixing in replacement of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2. Make: Nature switch: Kakatiya Energy systems/BAJAJ/Healer Contactors: BCH/L&T/Schneider MCBs: Hager/Schneider/L&T Enclosure: Hensel/GE or equivalent Circuit wiring: Polycab/ Finolex or equivalent
Supply and fixing of UPVC pipe of dia 40 mm passing through cables, Poles,walls,across the roads for cable protection with proper clamps, bends, nut & bolts washers etc complete all as specified and directed.
Taking out motor from base frame and transporting into local workshop for re-winding of CF / Monoblock electrical motor by disconnecting electrical & mechanical connections, opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with supper enameled copper wire / insulated copper winding wire as per the existing gauge, replacement of bearing and fan incl reassembling, testing and commissioning of electric motor on full load capacity of 5HP, three phase 415Volts 50 HZ including repair to pump by replacing unserviceable bearings of existing size and lathe work if required and refixing the same complete all as specified and directed by Engineer-in-Charge.
All as per item Srl No. 21 here in before but for CF / Monoblock electric motor of capacity of 3HP, complete all as specified and direcetd.
All as per item Srl No. 21 here in before but for Submersible/CF / Monoblock electric motor of capacity 0.5 to 1 HP, complete all as specified and direcetd.
Taking out the motor from base frame including Re-winding of induction motor by opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with super enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running of the capacity 55 KW/70 HP, complete all as specified and directed Note - (i) Any defective part to be replaced shall be measured and paid separately under respective item of schedule , here in after . Engr-in-charge approval shall be taken before declaring any part defective. However cost of fixing of spare or any machine work required is deemed to be included in the rates quoted by the contractor. (ii) Reassembling the motor and reinstallating in the installation including to and fro transporting charges upto approved workshop is deemed to be included in the rates quoted by the contractor. (iii) Paint to pump and motor with one coat of synthetic enameled paint matching with existing colour of motor is deemed to be included in the rates quoted by the contractor. . (iv) Required T&P such as lifting chain – pulley block and other lifting arrangement shall be contractors responsibility and shall be deemed to be included in quoted rate.
Supply and fix in replacement of bearing (6313)suitable for 55 KW/70 HP induction motor complete all as specified and directed.
Supply and fix in replacement of Fan suitable for 55 KW/70 HP induction motorcomplete all as specified and directed.
All as per item Srl No. 24 here in before but for induction motor of capacity 37 KW/50 HP, complete all as specified and direcetd.
Supply and fix in replacement of bearing (6312)suitable for 37 KW/50 HP induction motorcomplete all as specified and directed.
Supply and fix in replacement of Fan suitable for 37KW/ 50 HP induction motorcomplete all as specified and directed.
All as per item Srl No. 24 here in before but for induction motor of capacity 30KW/40 HP, complete all as specified and direcetd.
Supply and fix in replacement of bearing (6311)suitable for 30 KW/40 HP induction motorcomplete all as specified and directed.
Supply and fix in replacement of Fan suitable for 30KW/ 40 HP induction motorcomplete all as specified and directed.
Material and Labour only for taking out the Vertical Turbine pump of 75 HP along with connected shaft , after unscrewing the nuts /bolts , screws for Overhauling and reassembling after necessary repairs complete all as specified and directed . The cost element includes the following elements. (i) Disconnecting the connection of incoming cables to the motor. (ii) Taking down the 70 HP motor from the pump ( appx – wt 250 kgs ) after disconnecting the coupling and foundations bolts. (iii) Taking out the VT pump from sump . ( Appx. Depth of sump 20 feet and wt appx 500 kg ) complete with outer casing , etc . (iv) Strip opening the pump after unscrewing nuts / bolts , screws etc for servicing and replacement of any defective part. (vi) Reassembling the pump , lowering down , remounting the motor on pump , making connections and testing complete all as specified and directed
Supply and replacement of SS shaft socket for 70 HP VTPump set complete all as specified and directed
Labour for repair of vertical SS shaft 25 mm (threading both side with key way, straight, turning on lathe machine) complete all as specified and directed.
Supply and replace of Gun metal bush 6" to 8" long with stud suitable for VT pump complete all as specified and directed.
Supply and replacement of bearing suitable for VT pump of complete all as specified and directed.
Supply and fix in repairs of nuts, bolts, washer and studs of any size for VT/CF pump as per sample provided by Engr-in-charge, compete all as specified and directed by Engr-in-charge.
Taking out 70HP centrifugal Pump from base frame after unscrewing nuts / bolts , inlet –out flanged pipes and dismantling the pump from motor including transporting into local workshop for repairs and reassembling after necessary repairs which shall include the following elements – (i) Disconnecting the pump from motor after unscrewing the coupling nuts / bolts. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump with one coat of synthetic enameled paint matching with existing colour of motor.
Supply only Gland packing made out of graphite cotton of size 12 mm suitable for 70 HP CF pump set complete all as specified and directed
Turning and machining of 70 HP CF Pump cast Iron impeller with the existing size / design of manufacturer complete all as specified and directed .(Make of pump Mathar / Platt. )
Turning and machining of 70 HP CF Pump steel shaft to match the existing size / design of manufacturer complete all as specified and directed .
Supply and fix in replacement of bearing of 70 HP CF pump DE/NDE matching with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of neck ring for 70 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of stuffing box bush for 70 HP CF Pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of water thrower for 70 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Bearing End Cover for 70 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Sleeve for 70 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Shaft Protection cap for 70 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply only mild steel / cast iron coupling suitable for centrifugal pump of rating 70 HP complete with rubber tyre / coupling nuts bolts and rubber washer, complete all as specified and directed. Note: Making hole in the coupling matching with the size of shaft of pump and motor , cutting key slot shall be deemed included in quoted rate.
Taking out 50HP centrifugal Pump from base frame after unscrewing nuts / bolts , inlet –out flanged pipes and dismantling the pump from motor including transporting into local workshop for repairs and reassembling after necessary repairs which shall include the following elements – (i) Disconnecting the pump from motor after unscrewing the coupling nuts / bolts. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump with one coat of synthetic enameled paint matching with existing colour of motor.
Supply only Gland packing made out of graphite cotton of size 10 mm suitable for 50HP CF pump set
Turning and machining of 50 HP CF Pump cast Iron impeller with the existing size / design of manufacturer complete all as specified and directed .(Make of pump Mathar / Platt. )
Turning and machining of 50 HP CF Pump steel shaft to match the existing size / design of manufacturer complete all as specified and directed .
Supply and fix in replacement of bearing of 50 HP CF pump DE/NDE matching with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in replacement of neck ring for 50 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in replacement of stuffing box bush for 50 HP CF Pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in replacement of water thrower for 50 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Bearing End Cover for 50 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Sleeve for 50 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Shaft Protection cap for 50 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply only mild steel / cast iron coupling suitable for centrifugal pump of rating 50 HP complete with rubber tyre / coupling nuts bolts and rubber washer, complete all as specified and directed. Note: Making hole in the coupling matching with the size of shaft of pump and motor , cutting key slot shall be deemed included in quoted rate.
Taking out 30/40HP centrifugal Pump from base frame after unscrewing nuts / bolts , inlet –out flanged pipes and dismantling the pump from motor including transporting into local workshop for repairs and reassembling after necessary repairs which shall include the following elements – (i) Disconnecting the pump from motor after unscrewing the coupling nuts / bolts. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump with one coat of synthetic enameled paint matching with existing colour of motor.
Supply only Gland packing made out of graphite cotton of size 8 mm suitable for 30/40HP CF pump set complete all as specified and directed.
Turning and machining of 30/40 HP CF Pump cast Iron impeller with the existing size / design of manufacturer complete all as specified and directed .(Make of pump Mathar / Platt. )
Turning and machining of 30/40 HP CF Pump steel shaft to match the existing size / design of manufacturer complete all as specified and directed .
Supply and fix in replacement of bearing of 30/40 HP CF pump DE/NDE matching with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in replacement of neck ring for 30/40 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of stuffing box bush for 30/40 HP CF Pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of water thrower for 30/40 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Bearing End Cover for 30/40 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Sleeve for 30/40 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply and fix in repalcement of Shaft Protection cap for 30/40 HP CF pump with manufacturers design complete all as specified and directed. (Make of pump – Mathar / Platt.)
Supply only mild steel / cast iron coupling suitable for centrifugal pump of rating 30/40 HP complete with rubber tyre / coupling nuts bolts and rubber washer, complete all as specified and directed. Note: Making hole in the coupling matching with the size of shaft of pump and motor , cutting key slot shall be deemed included in quoted rate.
Supply and fix in replacement of rubber tyre coupling with nuts bolts and rubber washer suitable for 30 HP to 70 HP centrifugal pump set, shore hardness 80 degree +- 5 degree and max operating temprature 100 degree centigrate complete all as specified and directed.
Supply and replacement of PVC insulated unsheathed copper cable of size 25 sqmm 2 core 1100 volts grade confirming to IS -694/ 1990 including 40 mm dia PVC hose pipe complete all as specified and directed .
Disconnecting electrical connection of Non Clog submersible pump set of capacity 30 HP and taking out from the sewage well by using chain pulley block or by crane complete assembly with column pipe, electric motor, pump set, transporting to workshop and testing the complete and refixing with new, nuts, bolts & washers and lowering the same in same well (sewage/sludge)after the following repairs as mentioned here in after all as directed . (i) Disconnecting the electrical connection of pump and motorfrom pannel board. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and motor and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump and motor with one coat of synthetic enameled paint matching with existing colour of motor.
Re-winding of Non clog submersible electric motor of capacity 30 HP by opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with PVC insulated supper enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running.
Supply and replacement of 55 mm Mechanical seal suitable for 30 HP non clog submersible pumping set.
Supply and replacement of bearing (3310) suitable for 30 HP Non clog submersible pumping set
Supply and replacement of PCB ring suitable for 30 HP Non clog submersible pumping set
Supply and filling of compressor oil Suitable for non clog submersible pump set of 30 HP
Disconnecting electrical connection of Non Clog submersible pump set of capacity 20 HP and taking out from the sewage well by using chain pulley block or by crane complete assembly with column pipe, electric motor, pump set, transporting to workshop and testing the complete and refixing with new, nuts, bolts & washers and lowering the same in same well (sewage/sludge)after the following repairs as mentioned here in after all as directed . (i) Disconnecting the electrical connection of pump and motorfrom pannel board. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and motor and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump and motor with one coat of synthetic enamelled paint matching with existing colour of motor.
Re-winding of Non clog submersible electric motor of capicity 20 HP by opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with PVC insulated supper enamelled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running.
Supply and replacement of 48 mm Mechanical seal suitable for 20 HP non clog submersible pumping set.
Supply and replacement of bearing (6309) suitable for 20 HP Non clog submersible pumping set
Supply and replacement of PCB ring suitable for 20 HP Non clog submersible pumping set
Supply and filling of compressor oil Suitable for non clog submersible pump set of 20 HP
Disconnecting electrical connection of Non Clog submersible pump set of capacity 15 HP and taking out from the sewage well by using chain pulley block or by crane complete assembly with column pipe, electric motor, pump set, transporting to workshop and testing the complete and refixing with new, nuts, bolts & washers and lowering the same in same well (sewage/sludge)after the following repairs as mentioned here in after all as directed . (i) Disconnecting the electrical connection of pump and motorfrom pannel board. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and motor and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump and motor with one coat of synthetic enameled paint matching with existing colour of motor.
Re-winding of Non clog submersible electric motor of capacity 15 HP by opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with PVC insulated supper enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running.
Supply and replacement of 35 mm Mechanical seal suitable for 15 HP non clog submersible pumping set.
Supply and replacement of bearing (6308) suitable for 15 HP Non clog submersible pumping set
Supply and replacement of PCB ring suitable for 15 HP Non clog submersible pumping set
Supply and filling of compressor oil Suitable for non clog submersible pump set of 15HP
Disconnecting electrical connection of Non Clog submersible pump set of capacity 10 HP and taking out from the sewage well by using chain pulley block or by crane complete assembly with column pipe, electric motor, pump set, transporting to workshop and testing the complete and refixing with new, nuts, bolts & washers and lowering the same in same well (sewage/sludge)after the following repairs as mentioned here in after all as directed . (i) Disconnecting the electrical connection of pump and motorfrom pannel board. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and motor and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump and motor with one coat of synthetic enameled paint matching with existing colour of motor.
Re-winding of Non clog submersible electric motor of capicity 10 HP by opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with PVC insulated supper enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running.
Supply and replacement of 30 mm Mechanical seal suitable 10 HP non clog submersible pumping set.
Supply and replacement of bearing (6209) suitable for 10 HP Non clog submersible pumping set
Supply and replacement of PCB ring suitable for 10 HP Non clog submersible pumping set
Supply and filling of compressor oil Suitable for non clog submersible pump set of 10 HP
Disconnecting electrical connection of Non Clog submersible pump set of capacity 7.5 HP and taking out from the sewage well by using chain pulley block or by crane complete assembly with column pipe, electric motor, pump set, transporting to workshop and testing the complete and refixing with new, nuts, bolts & washers and lowering the same in same well (sewage/sludge)after the following repairs as mentioned here in after all as directed . (i) Disconnecting the electrical connection of pump and motorfrom pannel board. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and motor and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump and motor with one coat of synthetic enameled paint matching with existing colour of motor.
Re-winding of Non clog submersible electric motor of capicity 7.5 HP by opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with PVC insulated supper enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running.
Supply and replacement of 28 mm Mechanical seal suitable 7.5 HP non clog submersible pumping set.
Supply and replacement of bearing (6209) suitable for 7.5 HP Non clog submersible pumping set
Supply and replacement of PCB ring suitable for 7.5 HP Non clog submersible pumping set
Supply and filling of compressor oil Suitable for non clog submersible pump set of 7.5 HP
Disconnecting electrical connection of Non Clog submersible pump set of capacity 5 HP and taking out from the sewage well by using chain pulley block or by crane complete assembly with column pipe, electric motor, pump set, transporting to workshop and testing the complete and refixing with new, nuts, bolts & washers and lowering the same in same well (sewage/sludge)after the following repairs as mentioned here in after all as directed . (i) Disconnecting the electrical connection of pump and motorfrom pannel board. (ii) Strip opening the pump and replacement of unserviceable parts. (iii) Necessary lathe work for repair to pump. (iv ) Reassembling the pump and motor and reinstallating in the installation including to and fro transporting charges upto approved workshop (v) Paint to pump and motor with one coat of synthetic enameled paint matching with existing colour of motor.
Note for ser item No 33,39,51,63,77,83,89,95,101,&107 Any defective part to be replaced shall be measured and paid separately under respective item of schedule , here in after . Engr-in-charge approval shall be taken before declaring any part as defective. Required T&P such as lifting chain – pulley block and tripod (not less than 2 ton capacity and 20 feet lifting arrangement portable type ) or by crane and other lifting arrangement shall be contractors responsibility and shall be deemed to included in quoted rate by contractor)
Re-winding of Non clog submersible electric motor of capicity 5 HP by opening the motor , removing all burnt out coils, cleaning the slots and rewinding the same with PVC insulated supper enameled copper winding wire of same as existing gauge and reassembling , testing and commissioning of electric motor on full load for 4-6 hours continuous running.
Supply and replacement of 25mm Mechanical seal suitable 5 HP non clog submersible pumping set.
Supply and replacement of bearing (6208) suitable for 5 HP Non clog submersible pumping set
Supply and replacement of PCB ring suitable for 5 HP Non clog submersible pumping set
Supply and filling of compressor oil Suitable for non clog submersible pump set of 5 HP
Dismantling gear valve unit fixed in BML water point after unscrewing the nuts / bolts, screws etc, for repair and refixing the same after necessary repairs including servicing, greasing, oiling, gears, all moving parts and replacement of burn out nuts & bolts of sluice gate of size upto 1000 mm complete all as specified and directed . The cost element includes the following elements . (Note: The labour of machine work /welding works if required shall be included in the quoted rate) Note - (a) Any defective part to be replaced shall be measured and paid separately under respective item of schedule , here in after . EIC approval shall be taken before declaring any part as defective. (b)Required T&P such as lifting chain – pulley block and tripod (not less than 2 ton capacity and 20 feet lifting arrangement portable type ) and other lifting arrangement shall be deemed to included in quoted rate.
Replacement of Thrust bearing as per sample/existing model
Replacement of Gun metal nut
Replacement of New SS shaft (threadind)
Labour only for taking out the foot valve assembly of 30 HP to 70 HP along with connected 8 inch suction pipe after unscrewing the nuts /bolts , screws etc and reassembling after necessary repairs complete all as specified and directed . The cost of element includes the following elements, (i) Taking out the foot valve assembly from sump. ( Appx. Depth of sump 15 feet and wt appx 200 kg ) complete with suction strainer etc incl replacement of disc and sheet incl welding and lathe work if required. (ii) Reassembling the same after repair to foot valve , lowering down reassembling and testing complete all as directed. Note - Required T&P such as lifting chain – pulley block and tripod (not less than 2 ton capacity and 20 feet lifting arrangement portable type ) and other lifting arrangement shall be deemed to included in quoted rate.
Taking out unserviceable foot valve along with connected 8 inch suction pipe after unscrewing the nuts /bolts, screws incl supply, fixing and testing of new foot valve assembly suitable for 40 HP to 70 HP pump set 200 mm along with pipe complete with nuts /bolts and washers of appropriate size and rubber gasket etc all as specified and directed. Note - Required T&P such as lifting chain – pulley block and tripod (not less than 2 ton capacity and 20 feet lifting arrangement portable type ) and other lifting arrangement shall be deemed to included in quoted rate.
Taking out unserviceable Non return Valve including supply, fixing and testing of new Cast Iron swing check type Non Return (Reflux) Valve With SS-304 Disc and Nitrile Rubber Lining. Shell Test Pressure - 24.5 Kg/cm g, Seat Test Pressure 16 Kg/cm as per IS 5312, part-I, PN 1.6 without bypass arrangement, ends flanged suitable for 200 mm bore pipe complete with nuts /bolts and washers of appropriate size and rubber gasket etc complete all as specified and directed . Make – KIRLOSKAR/L&T / VENUS / SANT/ZOLOTO
Taking out unserviceable Double flanged centre line type butterfly Valve from BML , Limb II and III including supply and fixing of Double flanged centre line type butterfly Valve with DI body, SS 410 Stem, EDPM liner and with grear in PN 1.0 with SS 304 Disc suitable for 200 mm bore pipe complete with nuts /bolts and washers of appropriate size and rubber gasket etc complete all as specified and directed . Make – KARTAR/ model No K715 and eqvt make of KIRLOSKAR/L&T / VENUS / SANT/ZOLOTO
Taking out unserviceable CI/MS/DI bend from suction line in BML , Limb II and III including supply and fixing of Double flanged dend 90 degree suitable for 200 mm bore pipe complete with nuts /bolts and washers of appropriate size and rubber gasket etc complete all as specified and directed .
Taking down of existing old broken , rusted MS PIt cover with angle iron from valve pit of gear valve from clear water sump, near raw water sump at BML, limb II and III including material and labour for fabrication and fixing of MS cover made out of 3.15 mm thick MS sheet and MS angle iron section 40x40X4mm forsupporting theMS sheet double door with two nos of handle for lifting , locking arrangement including angle iron frame made up of 40x40x5 mm fixed in PCC including painting complete with one coat of super enamelled paint and civil work if required all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement of thimble Copper suitable for 16 sqmm complete all as specified and directed.
Supply and fix in replacement of thimble Copper suitable for 25 sqmm complete all as specified and directed.
Supply and fix in replacement of thimble Aluminium suitable for 50 sqmm complete all as specified and directed.
Supply and fix in replacement of thimble Aluminium suitable for 95 sqmm complete all as specified and directed.
Material and labour for fabricating and fixing of SS ISS Type 304 steel scraper blade(steel trus rake arms) shall be fabricated of 3 mm thick steel plate of 2 Mtr long and 125 mm wide in scraper mechanism, fitted parallel to the tank bottom, adjustable tie rod shall be support sludge rake arms, The rake arm shall be adjustable at the drive cage and shall be designed to meet AISC specification and fastened with stainless steel304 fasteners including fixing of 7 mm thick , 150mm wide and 2 mtr long leather complete all as specified and as directed.
Taking down of SS ISS Type 304 steel scraper blade(steel trus rake arms) including refixing the same with 7 mm thick , 150mm wide and 2 mtr long leather, fastened with stainless steel 304 fasteners complete all as specified and as directed.
Supply and fix in replacement of PVC suction hose pipe 4 inch dia ultra light & flexible with PVC spiral ribbed for extra strength with 2 Nos male connector nipples and 4 Nos clamps complete all as specified and as directed.
labour for cleaining of sewage well from bottom by means taking out soild sludge/sewage wastage to be disposed out side MOD Land from the starting point complete all as per specified and directed by Engr-in-Charge. (Size of well 5 to 7 metre depth , 6 to 8 metre dia approximate ) Sump well 1,2,8 &10. Notes: All safety tools are to be provided by the contractor.
Supply and fix in replacement of Direct on line starters in sheet enclosure type MN/ML of 7.5KW/10HP, ralay range 9-15A, AC-m duty, 415 V ,50 HZ 3 phase cat No SS94531 of L&T and Eqvt make complete all as specified and as directed.
Taking down including supply and replacement of contactor AC 415 volt , operating coil -230 volts , 70 amps Three pole rated capacity make – LT type MNX- 70 or equivalent complete all as specified and as directed.
Taking down including supply and replacement of contactor AC 415 volt , operating coil -230 volts , 50 amps Three pole rated capacity make – LT type MNX- 50. complete or equivalent acomplete all as specified and as directed.
Taking down including supply and replacement of contactor AC 415 volt , operating coil -230 volts , 40 amps Three pole rated capacity make – LT type MNX- 40. or equivalent complete all as specified and as directed.
Taking down including supply and replacement of contactor AC 415 volt , operating coil -230 volts , 32 amps Three pole rated capacity make – LT type MNX- 32. or equivalent complete all as specified and as directed.
Taking down including supply and replacement of contactor AC 415 volt , operating coil -230 volts , 9 amps Three pole rated capacity make – LT type MNX- 9. or equivalent complete all as specified and as directed.
Taking down including supply and replacement of bimetallic over load relay range 45 to 75 Amp, 3 phase, 415 V, for electric motor upto 70 HP Make L&T or equivalent complete all as specified and as directed.
Taking down including supply and replacement of electronic timer suitable for electric motor ST 100 30HP to 70 HP, 415V,3 phase, complete all as specified and directed Make L&T or equivalent.
Supply & fix in replacement of MCCB 3 Pole 415Volts 36KA 250 Amps current capacity adjustable thermal magnetic release range overload/short circuit protection type complete with connected accessories including necessary connection with bus bar and out going cables all as specified and directed
Supply & fix in replacement of MCCB 3 Pole 415Volts 36KA 200 Amps current capacity adjustable thermal magnetic release setting range overload/short circuit protection type complete with connected accessories including necessary connection with bus bar and out going cables all as specified and directed.
Material and labour for painting of Rising /Delivery /Washout/Overflow pipe of sizes 100 to 200 mm of Overhead tanks including cleaning the surface with sand paper and priming with one coat of red oxide primer with two coats of synthetic enamel paint (colour of paint for Blue for Rising main, Red for distribution, Green for Overflow and Yellow for washout) of Tank No 1,2,3,4,5,6,8,9,10,12,13,14,15,16,18,19,20,21,22,23,24 & 25 complete all as specified and as directed by Engr-in-Charge.
Note:- (a) The rates are included of arrangemant of safety equipment, setting of scaffolding upto the height of approx 25 mtrs for painting of pipes or any other technology used by contractor. (b) All Safety measures will be taken care by contractor while execution of work.
Material and labour for painting of Centrifugal pump and motor installed at LIMB II, LIMB III & BML & connected pipes upto SV/NRV including cleaning the surface with sand paper and priming with one coat of red oxide primer and two coats of synthetic enamel paint of existing colour with the help of sprayer and writing MES/SM No both on Pump and motor complete all as specified and as directed.
Suppy only calcium hypochlorite 65% to 70% chlorine content in granular form, calcium based granular chlorination chemical aal as specified and directed. Make of product -DECLIBAC/PURI CHLOR/AQUAFITAQUA PURA or equivalent. as approved by GE Note : (i) High strength calcium based granular chlorination chemical to packed in plastic drum of 45 Kgs each (iii) The brand and make of the chlorination chemical must be stated and certificate of Hygiene & Public Health (Govt of India) conforming compliance to all the above specification technical strength, stability,health, safety and operational point of view as well as the fact that this product is used for water supply installations.
Supply only Alum Ferric grade - IV for RAW water at BML for coagulation and trapping of suspended matter and colour in water in controlled manner to maintain PH value in the range of 7.2 to 7.6 complete all as specified and as directed.
Supply and fixing junction box of size 140mmx140mm x95mm made out of hot pressed moulded SMC with weather proof hinged door incl self locking arrangement outdoor type weather and vrming proof complete comprising of insulated/high quality PVC sleeves aluminium bus bar of capcity 63 Amps 02 Nos (1 phase and neutral) including 25x3 mm flat iron mounted on insulators, having arrangemnet of connecting and outgoing cables with suitable size of lugs complete all as specified and as directed.
Supply and fix crown shaped LED post top lantern 1 x 25 watt LED luminaire incl 20 Watts LED lamp IP 65, energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution , spun alumiminium landscape luminaire with high power LEDs and in soothing opel finished made up of polycarbonate B 22 base clear cover offers bright illumination all specified and directed by Engr-in-charge. Make : Havells/CG or any equivalent make
Material and labour for fixing of light grade GI pipe of size 40mm, length 3mtr (50mm below ground) including PCC 1:2:4 (20mm aggregate) 50mm below ground and 20 mm above the ground (coping) for fixing of post top lantern in BML (VT pump room to chlorination plant room), TW No 3 and 09 all specified and directed by Engr-in-charge. Note :- (i) Size of PCC below ground is 50mm x40mm x40mm and size of coping is 20mm x 20mm x 20mm. (ii) PVC junction and light wiill be fixed under relevent items. (iii) Cost of wire from PVC Junction box to light and excavation for fixing of GI pipe is deemmed to be included in quoted rates.
Supply and laying XLPE insulated heavy duty electric cables with aluminium conductor 1100 Volt grade cross sectional area 6 Sqmm 2 Core complete all as specified and as directed.
S&F GI pipe light grade 25 mm passing through cables, walls, across the roads, pole with proper clamps, nuts & bolts complete all as specified and directed.
Supply and fix LED light fitting 45 watt 230 V AC outdoor type new generation energy saving and enviromental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening seperate driver compartment with IP 66 protection and impact resistance of IK08 including GI bracket of 40 mm dia pipe light grade 1.0 mtr length fixed with MS clamps for mounting of light all as specifired and as directed by Engr- in-charge.
Supply and fixing of Flexible copper cable of size 1.5 sqmm 2 core making connection to aviation obstruction light including 15 mm dia heavy duty PVC pipe fixing with clamp complete all as specified and directed.
supply and fix submersible cable 3 core copper conductor flat type,16 sqmm complete all as specified and directed.
Supply and install Glow sign board fabricated with GI sheet 20 SWG of size 4000 x 750 x 200 mm frame box type made out of angle iron / conduit round pipe including wiring 23/.0076 PVC copper wire twin core and connecting to LED tube light fitting 1*20 watts- 04 Nos (Make :- Havells/ Philips) and the front side should be covered with good quality of flex sheet blue colour 3mm thick and to be mounted on square / round MS pipe and fixing at BML installation, complete all as directed. Notes:- (a) Glow sign board should openable from one side for repairs. (b) Square/round MS pipe should fixed on the wall all as directed by Engr - in -charge. (c) The word on board shall be written with computrized machine CLEAR WATER PUMP HOUSE AND SUMP (04 NOS) AGE E/M, GE(NORTH) PATIALA
M&L for 'B' check of DG Sets of capacity 100 KVA complete as per following :-(i)Draining out engine/lubricant oil, flushing including filling fresh oil after drain out old oil by skilled tradesman of DG set including replacement of oil pan /chamber gasket. (ii)S& F in replacement lubricant oil filter element. (iii)S&F in replacement fuel filter element. (iv)S&F bypass filter element. (v)checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirment. (vii) Cheking hose and fuel pipe and fix new if required.Note- Cost of Engine/lubricating oil, oil Filter element, fuel filter element, bypass filter element ,fuel/hose pipe are included in this item and nothing shall be paid extra on this account
All as per Srl item No 161 above but DG Set DG Set Cap 200 KVA complete all as specified and directed.
All as per Srl item No 161 above but DG Set DG Set Cap 380/400 KVA complete all as specified and directed.
M&L cleaning of diesel tank of DG Set of any capacity 100 to 400 KVA including replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as specified and directed.
Supply and fixing in replacement Battery Terminals heavy duty Copper.(Positive & Nagative) complete set complete all as specified and directed. .
Supply and fixing in replacement Battery Copper cable Red having length not less than 2.2 metre and size 50 Sqmm with plug complete all as specified and directed.
Supply and fixing in replacement Battery Copper cable black having length not less than 2.2 metre and size 50 Sqmm with plug complete all as specified and directed.
Supply and fix in repalcement of 12 volts 150 AH battery with float guide to indicate Electrolyte level,spill proof, moulded handles, top vented lid with anti splash guards fitted with coin flush vent plugs, spark arrestor fitted in float to restrict fumes and acid during operation Complete all as directed by Engineer-in-charge.Make of battery Exide or any eqvt approved make
Supply and fix in repalcement of 12 volts 180 AH battery with float guide to indicate Electrolyte level,spill proof, moulded handles, top vented lid with anti splash guards fitted with coin flush vent plugs, spark arrestor fitted in float to restrict fumes and acid during operation Complete all as directed by Engineer-in-charge.Make of battery Exide or any eqvt approved make
Material and labour for servicing of automatic mains failure panel 24 volts DC and 440 Ac supply operated system locating by fault and replacement of unservicaeble parts and components complete all as specified and directed as per the following:- (a) Repair of worn out /faulty internal wiring DC/AC for engine starting and off with adeqaute and suitable size copper conductor wire, connected with proper copper lugs and terminals through protection pipe/casing.(b) Replacement of worn out faulty internal wiring of controls and timers indicating /measuring instruments through various control fuses and relays with suitable and adeqaute size of copper conductor wire connected with suitable copper lugs and terminals. (c) Replacement of worn out small control fuses, indicating lamps various types of type of copper thimble , lugs terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order. (d) Material and labopur for painting of AMF Panel metalic body surface with one coat of superior quality synthetic enamel paint of approved colour and 1st quality including replacement of worn out rubber beading.(e) Testing of system on load
(Note: Supply only spare parts for repalcement where require shall be measured and paid seperately.) of various capacity of Dg sets installed at various locations of capacity 380/400 KVA-01
Supply and fixing in replacement solid state electronic engine starting relay 24 volts
Supply and fixing in replacement alternator voltage monitor relay 3 phase 415 volt
Supply and fixing in replacement main voltage monitor relay 3 phase 415 volt
Supply and fixing in replacement under voltage monitor relay 3 phase 415 volts
Supply and fixing in replacement solid state electronic timer 0-60 seconds 24 volts DC
Supply and fixing in replacement Electronic earth faulty relay for alternator protection 24 volts DC
Supply and fixing in replacement electronic over load relay for alternator protection 24 volts DC
Supply and fixing in replacement battery charging rectifier 4 plate 24 volts DC
Supply and fixing in replacement concord 11/244 pin 24 volts DC
Supply and fixing in replacement of 3 pole F line contactor for resistive load 4630 A , 400 KW TESYS F Series , power pole contact composition 3 No ,operational current 1000A at 440 V AC AC-1 ,motor power 375 KW at 415 V AC 50/60 Hz (AC-3) Model No LC1-F630 of Schneider confirming to IEC 60947-4-1 or any equivalent make
Supply and fixing in replacement of HRC fuse link 630 A IS IEC size 3 model No CDFL3 630 A OF C&S ELECTRIC or any equivalent make
SWAMI ENGINEERS
krishna engineers
Arneja Builders
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .