Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹41.8 L+₹6.8 L (19.5%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance Not being L1 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
19 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR M K YADAV
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
PROVISION OF PARTITION WALL WITH DOORS AND CUPBOARDS IN AIRMEN BILLETS AND ADDITION ALTERATION TO P 19 AT AF STATION SALUA UNDER GE AF STN KALAIKUNDA
2024_MES_642825_1
C/8937/E8
Open Tender
Civil Works
Item Rate
180 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹87,000
Yes
31 Mar 2024
16 Feb 2024
20 Mar 2024
16 Feb 2024
19 Mar 2024
1 Mar 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil ,complete all as specified and directed Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this regard GE's decision will be final.
Returning filling in any type of soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
Materials and Labour for plain cement concrete (1:4:8) Type D-2 using 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
M & L for RCC M-25 design mix concrete with using 20mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc all as specified
M&L for Steel Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
M & L for brick work with Fly Ash bricks, straight or curved on plan to exceeding 6m mean radius, built in 1:6 cement mortar complete all as specified.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces applying 1.5 mm thick wall care putty and rubbing with sand paper to achieve a level and smooth to wall and applying two coats of oil bound distemper over a coat of primer on walls complete all as specified
S&F of TMT reinforcement bar, conforming to Fe-500, 6mm to 8mm dia and over cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, as in stirngs spaces and binders hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with chips.
S&F TMT reinforcement bar, conforming to Fe-500, 10mm dia and over cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with chips.
Demolition of cement concrete (un reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground (level) and lowering if necessary, removal of the rubbish off the premises all as specified and directed.
Material and labour for Providing, cement concrete (1:2:4) type B1 using 20 mm graded stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including all necessary form work, Complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position and removing the rubbishes off the premises
M & L for RCC M-25 design mix concrete with using 20mm graded stone aggregates as in chajjas all as specified
M & L for RCC M-25 design mix concrete with using 20mm graded stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified
M & L for RCC M-25 design mix concrete with using 20mm graded stone aggregates as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified.
M&L for Steel Formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for Steel Formwork to flat sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing and depositing serviceable tiles where directed, and rubbish off the premises.
Materials and Labour for, Vitrified Ceramic tiles, light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 20 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified .
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm and n.exc 4.00 Sqmm each complete all as specified and as directed (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, size 125 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
M &L PCC (1:3: 6) type C1 using 20 mm graded crushed stone aggregate as in bed plates & filling in prssed steel door frame complete.
S & F 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, panelled shutters (two panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated complete all as specified.
M & L for 35 mm thick,Factory made timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified
Supply only 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S&F 150mm aluminum extruded aluminium alloy handles (fabricated type) anodised of mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S&F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S&F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F og 18/19mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination , fixed with screws to timber frame work
M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) over and including 12mm thick screed bed or bedding layer in cement mortar (1:3) and jointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/Blankets/ Slabs, any description and any thickness including Cover Fillets, Cornices, etc., complete all as specified and as directed.
Taking down cement or cement lime plaster on brick or stone walls etc. including racking out joints hacking for key scrubbing down with water etc.complete.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, at any height with ensuring safety measures complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
M&L for Rendering 5mm thick in Cement Mortar 1:3 on ceiling surfaces finishing even and smooth without using extra cement complete all as specified.
Supply only liquid water proofing compound.
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of oil bound distemper on the wall all as specified and directed
Material and labour for preparation of new plastered surfaces applying 1.5 mm thick wall care putty and rubbing with sand paper to achieve a level and smooth to wall and applying two coats of cement base paint over a coat of primer on walls complete all as specified and as directed.
Material and labour for preparation of new plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and as directed.
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling including cornices, pilasters and other wall features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white wash on ceiling all as specified and directed
Material and labour for complete removal of existing treatment and applying 1.5 mm thick wall care putty and rubbing with sand paper to achieve a level and smooth to wall and applying two coats of cement base paint over a coat of primer on walls complete all as specified and as directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital glazed ceramic coloured tiles, 300 X 200 X 8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
S&F of Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Glazing with sheet glass 4.8 mm thick ordinary quality in panels of aluminium windows, ventilator, door etc. fixed with glazing clips, rubber beading and EDPM gasket in square not exceeding 0.5 Sqm in each pane.
S&F of 140mm long (Overall length of cover plate) Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
Supply and Fix, steel ventilator with top hung shutter including hinges, steel peg stay, complete, dovetailed or welded, including making good disturbed surfaces as per existing specfication complete all as specified and directed.
Supply & fix sheet glass, ordinary quality, 4 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
S & F 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S & F stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and Fix, factory made solid panel Plain PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of both sides plain PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
Supply and Fix, solid PVC door frame of size 50 mm X 47 mm made out of 5 mm Prelam PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed.
S & F 20mm bore PVC coated MS conduit drapery rods, suitable for door/widows curtain with incl necessary fancy type dooms as approved by GE, and fitted to each end, brackets and fixed to wall complete all as specified and directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.25 mm thickness, size 105 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
Supply only 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
M&L for preparation of old painted surfaces of Steel surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel painting complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 type C1 with using 20 mm graded stone aggregate as in plinth protection laid in panels with 10mm joints at 3m interval and corner, finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
M&L for filling joints of depth 50mm with bitumastic mix with 80/25 bitumen and coarse sand mixture. 1:3 by weight
Taking up or down, steel tubing 15 mm bore, and connection including cleaning for re-fixing or removal from site of work complete all as directed.
Taking up or down, steel tubing 20 mm bore, and connection including cleaning for re-fixing or removal from site of work complete all as directed.
Materials and Labour for galvanized steel tubing, medium grade, 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed.
Materials and Labour for galvanized steel tubing, medium grade, 20 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed.
Refixing old steel tubing and connections 15mm bore in new or old position (wall, ceiling , floors) etc complete all as specified and as directed.
Refixing old steel tubing and connections 20mm bore in new or old position (wall, ceiling , floors) etc complete all as specified and as directed.
Supply and Fix in repairs , stop valves, cast copper alloy , fancy type, chromium plated, screwed down, high pressure with long shank and cup (concealed type), screwed both ends for steel pipe of for unions, 15 mm bore, complete all as specified and directed.
Supply and Fix in repairs , stop valves, cast copper alloy , fancy type, chromium plated, screwed down, high pressure with long shank and cup (concealed type), screwed both ends for steel pipe of for unions, 20 mm bore, complete all as specified and directed.
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant and including CP jet nozzle for EWC incuding connection to GI pipe line complete complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Vitreous China urinals, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S & F of 15mm size PVC connections with PTMT nuts of length 450mm complete all as specified and directed.
S&F Tubular towel rail, 20mm dia, D type, 60cm long between flanges
M&L Cast iron floor trap for 100 mm dia outlet, with SS grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
Supply and Fix bib tap, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
Demolition of brick work built in CM including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing the rubbishes off the premises
Surface excavation n.exc.30 cm deep and averaging 15 cm deep and getting out in soft/loose soil including clearing away all grass vegetation, saplings, shrubs, brush wood, under growth, roots and trees n. exc. 30cm girth and removing rubbish upto a distance of 50 metre out of the periphery of the area complete all as specified and as directed.
M&L for Hardcore of broken stone aggregate of guage n.exc 63mm , deposited, spread and levelled in layers n exc. 15 cm thick, consolidated, watered and rolled/rammed to a true surface
M&L for 100mm thick PCC 1:2:4 type B2 with using 40 mm graded stone aggregate as in sub base to floor finished rough to receioved the top layer complete all as specified and directed by Engr-in-Charge.
M&L for machine pressed precast concrete interlocking paver block of any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade laid over 50 mm thick sand cushion complete all as specified and approved by Engineer-in-Charge.
Dismantling Wrought Iron or Mild Steel Work, viz. Mild Steel Flat Iron, Mild Steel Bars, Bends, Straps and Similar Work including Mild Steel Bolts, Nuts, etc., fixing to RCC Fencing Posts, Struts, etc. complete all as specified and as directed.
Taking down carefully point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall, ceiling etc including seperating serviceabel light fittings, switches etc and keeping in safe custody for reuse and removal of unserviceable materials from site complete all as specified and directed.
M & L for concealed point wiring complete with 1.5 sq mm FRLS, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC insulated 1.5 sq mm copper conductor for earth continuity (Green Colour) and connected to common earth dolly and including pressed steel terminal flush boxes made out of 1.6 mm thick MS sheet or modular metal flush boxes conealed in wall and laminated sheet cover of 3 mm thick for housing the switches, socket outlet, regulator, etc. all as specified and directed by Engineer-in-Charge.,all as specified and directed by Engineer-in-Charge for one light/fan point controled by one one way 5/6 Amp switch Note:- (a) Note :- Cost of PVC conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface, box and cover plate are deemed to be included in the quoted rate.
All as per BOQ item No 91.00 here-in-before but for one 5 pin socket outlet 06 Amps on same board
All as per BOQ item No 91.00 here-in-before but for one 5 pin socket outlet 06 Amps on independent board ( but Not below the switch board of light points in the same vertical plane)
All as per BOQ item No 91.00 here-in-before but for one bell point
All as per BOQ item No 91.00 here-in-before but for one power pointt using by 2.5 sq mm copper conductor cable with 2.5 sq mm PVC insulated single core copper cable for earth continuity conductor, on independent board
Supply & fixing switch piano flush button AC 230 V single pole 5/6 Amps one way.
Supply and fix switch socket combination 6 Amp 5 pin flush type as specified and directed.
Supply & fix switch socket outlet combination, multipurpose 5/15 Amps flush type universal all as specified and directed.
Supply & fixing ceiling fan regulator,electronictype,step type 5 variable speed AC, 230 volts all as directed by Engineer-in-Charge
Supply & fix bell push flush type 5 Amps
Supply & fixing call bell SP 230 volts Ding dong type
S&F Lamp holder, PVC/Polycarbonate, angular type with back plate suitable for batten fittings
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
Supply and fixing for sub main wiring with two run of single core FRLS 4 Sqmm PVC insulated unsheathed stranded cable copper conductor drawn in including through PVC casing caping of suitable size with all fittings including 4.00 sq mm PVC insulated unsheathed single core copper conductor as earth wire complete all as specified including taking out complete existing sub main wiring with conduit. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 4 sqmm and one run of PVC casing caping will be measured as one length.
Supply and fixing for sub main wiring with two run of single core FRLS 6 Sqmm PVC insulated unsheathed stranded cable copper conductor drawn in including through PVC casing caping of suitable size with all fittings including 6.00 sq mm PVC insulated unsheathed single core copper conductor as earth wire complete all as specified including taking out complete existing sub main wiring with conduit. Note : (i) Two run of single core cable 6 sq mm and one run earth wire 6 sqmm and one run of PVC casing caping will be measured as one length.
S&F in repairs DB Box, in sheet metal enclosure VT DB TPN, MCCB DB TPN 6 way, double door With provision for 3 pole and 4 Pole MCCB(Up to 125A) as incomer and SP/TP MCBs as outgoings, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 200 Amp copper bus bar for each phase, with 2 Neutralbar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set, including flushing and fixing DB box in neaty in wall complete all as specified and directed by Engr-in-charge. :
S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated copper busbar, 4 way Double door enclosure made up of CRCA sheet steel, RAL powder coated, IP 43,IK09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with and electrically connecting up complete all as specefied.
All as per BOQ item No 107.00 here-in-before but for 8 way
Supply and fix thermal-magnetic release, Ics = 100% Icu, MCCB 415 volts, 3 phase, 50 Hz, 4 pole of capacity 63 to100 Amps 25 kA including necessary connection complete all as directed by Engr-in-Charge.
S&F MCB SPN 240 volts 40 to 63 Amps, 10 KA breaking capacity, 'B' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S&F MCB FP 240 volts 40 to 63 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S&F MCB TP 240 volts 40 to 63 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S&F MCB SPN 240 volts 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S&F MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S & F in repair single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, complete all as specified and as directed.
S&F LED 20 Watt tube light fitting (T8 type), single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed:
S & F in repair LED street lights nominal power 35 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S&F in repair LED 2 ft, 9-10 Watt light fitting mirror type intergated type, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 epoxy powder coated white extruded aluminium channel housing, life span of minimum 50000 working hours complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed.
Supply , fixing and hanging ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including necessary connection
Supply and Fix, Exhaust Fan, 250 mm sweep made out of high quality engineering plastic with gravity shutter, 1200 RPM, Single Phase, 230 V, 50 Hz, and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan with and including cutting holes of adequate size and making good the disturbed surfaces as per existing, suitable for fixing exhaust fan for complete all as specified and directed by Eng in Charge.
S&F LED indoor wall light 3 W , goose neck arm, aluminium body operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 150 lumens , protection grade IP 20, CRI greater than 80%
Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 3.0 mtr deep below ground level) with top edge of the plate not less than 2.4 mtr below ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Marconite , (4 bags of 25 Kg each ), construction of inspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately
(Note for BOQ Srl No 122.00 : (i) Contractor shall use low reisistivity fresh agriculture soil , mixed with marconite each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 4 x Bags of marconite deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. . (vii) The cost of Copper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil upto a distance of 100 mtrs.
SUMAN CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .