Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹52,900
Closing Date
6 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
Mumbai Central Jagjivan Ram Hospital - Repairing/ replacement of defective parts of Window AC & Split AC units of various makes & capacities at Jagjivan Ram Hospital for 2 years.
EL-Maint-4-344-WA-9~WR
EL-Maint-4-344-WA-9
Open
Works - General
24 Months
Mumbai, Maharashtra
₹0
₹52,900
4 Sept 2026
4 Sept 2026
22 Sept 2026
73 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 26,45,051 | ||
| — | 2000.00 | — | — | ||
| Cleaning of filters, condenser coil, evaporator coil, checking of working of AC unit, electrical connections etc; once in 02 months, as per specifications in Annexure I. | — | — | — | 3,94,000 | |
| — | 15.00 | — | — | ||
| Replacement of defective rotary compressor by new rotary compressor of 1.5 TR capacity, as per specifications in Annexure II. | — | — | — | 1,63,050 | |
| — | 4.00 | — | — | ||
| Replacement of defective rotary compressor by new rotary compressor of 2.0 TR capacity, as per specifications in Annexure III. | — | — | — | 51,648 | |
| — | 10.00 | — | — | ||
| Replacement of defective rotary inverter type compressor by new rotary inverter type compressor of 1.5 TR capacity, as per specifications in Annexure IV. | — | — | — | 1,61,970 | |
| — | 80.00 | — | — | ||
| Supply of gas, flush the system with nitrogen, hold the system on pressure at 275 psi to detect leakage, repairing by brazing, vacuumizing and refrigerent gas charging of window AC - 1.5TR, and split AC 1.5 / 2.0 / 3.0 TR capacities, as per specifications in Annexure V. | — | — | — | 2,11,600 | |
| — | 10.00 | — | — | ||
| Rewinding of defective condenser's fan motor of window ACs, 1.5TR capacity, as per specifications in Annexure VI. | — | — | — | 13,210 | |
| — | 6.00 | — | — | ||
| Replacement of defective condenser's fan motor of window ACs, 1.5TR capacity, as per specifications in Annexure VII. | — | — | — | 14,616 | |
| — | 15.00 | — | — | ||
| Rewinding of defective condenser's fan motor of split ACs, 1.5 /2.0 / 3.0TR capacity, as per specifications in Annexure VIII. | — | — | — | 18,765 | |
| — | 10.00 | — | — | ||
| Replacement of defective condenser's fan motor of split ACs, 1.5 /2.0 / 3.0TR capacity, as per specifications in Annexure IX. | — | — | — | 25,030 | |
| — | 10.00 | — | — | ||
| Replacement of defective DC condenser's fan motor for inverter type split AC 1.5/2.0/3.0 TR capacity, as per specifications in Annexure X. | — | — | — | 31,950 | |
| — | 45.00 | — | — | ||
| Repairing of PCB circuit of window AC 1.5TR and split AC of 1.5 / 2.0 TR capacity non inverter type, as per specifications in Annexure XI. | — | — | — | 56,295 | |
| — | 25.00 | — | — | ||
| Repairing of PCB circuit for window AC 1.5 TR & split AC of 1.5/2.0 TR capacity inverter type for indoor and outdoor units, as per specifications in Annexure XII. | — | — | — | 91,325 | |
| — | 10.00 | — | — | ||
| Replacement of PCB circuit for window AC 1.5 TR & split AC of 1.5/2.0 TR capacity inverter type for indoor and outdoor units, as per specifications in Annexure XIII. | — | — | — | 1,46,110 | |
| — | 5.00 | — | — | ||
| Replacement of indoor unit evaporator's motor DC and non DC for split AC of 1.5 / 2.0 TR capacity, as per specifications in Annexure XIV. | — | — | — | 10,465 | |
| — | 60.00 | — | — | ||
| Replacement of capacitor P2 type 36/45/50 MFD or dual type 36/10, 45/6, 50/6 MFD, as per specifications in Annexure XV. | — | — | — | 23,700 | |
| — | 30.00 | — | — | ||
| Replacement of capacitor P2 type 2.5 to 10 MFD; as per specifications in Annexure XVI. | — | — | — | 4,920 | |
| — | 5.00 | — | — | ||
| Replacement of condenser fan blades for window ACs of 1.5TR and Split Acs of 1.5 / 2.0 / 3.0 TR capacities; as per specifications in Annexure XVII. | — | — | — | 6,255 | |
| — | 5.00 | — | — | ||
| Replacement of blower drum for window AC unit 1.5TR capacity, as per specifications in Annexure XVIII. | — | — | — | 6,255 | |
| — | 3.00 | — | — | ||
| Replacement of defective / aluminum condenser coil by new copper condenser coil for inverter and non-inverter type window AC units 1.5 TR capacity; as per specifications in Annexure XIX. | — | — | — | 17,787 | |
| — | 10.00 | — | — | ||
| Replacement of defective / aluminum condenser coil by new copper condenser coil for inverter and non-inverter type split AC units 1.5 TR capacity; as per specifications in Annexure XX. | — | — | — | 59,290 | |
| — | 2.00 | — | — | ||
| Replacement of defective / aluminum condenser coil by new copper condenser coil for inverter and non-inverter type split AC units 2.0 TR capacity; as per specifications in Annexure XXI. | — | — | — | 13,176 | |
| — | 30.00 | — | — | ||
| Replacement of internal wiring of AC units, by new copper wire with lugs, PVC insulated unsheathed FRLS copper wire flexible multi- strand, of size 1.5 / 2.5 mm², single core; as per specifications in Annexure XXII. | — | — | — | 3,930 | |
| — | 150.00 | — | — | ||
| "Removal of old cable and, supply, fixing, testing and commissioning of PVC insulated & sheathed copper cable flexible multi-strand, 1100 Volt grade, FRLS, confirming to IS: 694 of 2010 or latest / IEC / NEC / NFPA Standards, ISI marked of reputed make, for interconnection to indoor and outdoor unit. The connection shall be made with suitable bi-metallic crimping sockets of proper size & rating. The cable shall be fixed with proper workmanship.Cable size: 2.5 sq.mm., 4 core." | — | — | — | 22,650 | |
| — | 5.00 | — | — | ||
| "Supply and installation of contactor for spilt AC unit. Scope of work covers:• Remove the defective contactor and replace it by new contactor of same size, shape, capacity, specifications and other parameters that of the existing.• Released contactor shall be handed over to Railway Supervisor." | — | — | — | 2,285 | |
| — | 10.00 | — | — | ||
| Installation, testing & commissioning of split AC units of capacity 1.5 TR/2.0 TR at the nominated site complete with all accessories, as per specifications in Annexure XXIII. | — | — | — | 13,920 | |
| — | 130.00 | — | — | ||
| Supply and fixing of refrigerant copper tubing with insulation of required size, copper pipe dia 5/8" or 3/8" or 1/2" as per site requirement, complete with hardware fittings, as per specifications in Annexure XXIV. | — | — | — | 64,480 | |
| — | 130.00 | — | — | ||
| Supply and fixing of refrigerant copper tubing with insulation of required size, copper pipe dia 1/4", complete with hardware fittings as per specifications in Annexure XXIV. | — | — | — | 35,620 | |
| — | 90.00 | — | — | ||
| "Supply and fixing of drainage CPVC pipe line of plumbing grade conforming to Standard - IS 15778, Class-SDR 11, ISI marked, with threaded type accessories.Nominal bore size - 25 mm, thickness - 2.6 mm minimum with tolerance 0.51 mm or Nominal bore size - 40 mm, thickness - 3.8 mm minimum with tolerance 0.51 mm. Size of the pipe shall be decided by the SSE as per site requirement. PVC pipe line shall be fixed by PVC/G I saddling with proper slope so as to drain out the condensate water easily. Drainage pipe line should be terminated at the nearest drain. The work shall be done with proper workmanship." (Qty Unit - RM = (Running Meter) | — | — | — | 7,650 | |
| — | 15.00 | — | — | ||
| Supply of labour with transportation and removing, shifting of AC units from one location / station to another location / station, as per scope of work in Annexure XXV. | — | — | — | 13,665 | |
| — | 20.00 | — | — | ||
| "Supply, installation, testing & commissioning of Digital Thermometers at nominated sites:a) A standard digital LCD fridge thermometer with an external wired probe typically measureing a temperature range of -50*C to +110*C (-58*F to +230*F) with accuracy of ±1*Cb) Probe and Cable: Waterproof external metal/ bullet sensor on a 1-meter to 3-meter (3.3 ft to 10 ft) long cable.c) Mounting Options: Magnetic backing, suction cup, or fold-out stand for placement on or inside the Refrigerator." | — | — | — | 15,900 | |
| — | 5.00 | — | — | ||
| "Supply, installation, testing & commissioning of new indoor evaporator cooling coils replacing defective indoor unit coils:a) Material Composition: Premium inner-grooved copper tubes combined with copper or aluminium fins.b) Tube Diameter / Thickness: Standard outer diameters range from 7mm to 9.52mm, with wall thickness around 0.28mm.c) Surface Treatment: Blue fin, golden fin or epoxy powder coatings to prevent rust, corrosion and salt accumulation.d) Configuration: Multirow staggered copper tubes mechanically expanded into hydrophilic aluminium fins to enhance moisture runoff and heat exchange.e) Testing Pressure: 450-550 PSI " | — | — | — | 47,500 | |
| — | 6.00 | — | — | ||
| "Supply, installation, testing & commissioning of Air Curtains of Size 36" (3 Feet):a) Motor: Single phase 230 VAC, 0.25 HP, 1440 RPM, Class B insulationb) Dimension: 225mm x 230mm x 900mmc) Impeller - Dia & length: Aluminium, 160mm x 360mm - 2 Nos. d) Velocity: 12-14 m/sece) Air outlet: Belowf) Air suction: Frontg) Noise Level: 50-60 DBe) Magnetic Sensor: Model No- 1L- AC-101Sf) The unit shall be provided with an easy mounting arrangement, comprising a flat mounting frame suitable for wall fixing using appropriate coach screws/ suitable arrangement as per site requirement." | — | — | — | 2,48,508 | |
| — | 2.00 | — | — | ||
| "Supply, installation, testing & commissioning of Air Curtains of Size 39" (1 MTR):a) Motor: Single phase 230 VAC, 0.25 HP, 1440 RPM, Class B insulationb) Dimension: 225mm x 230mm x 1000mmc) Impeller - Dia & length: Aluminium, 160mm x 410mm - 2 Nos. d) Velocity: 12-14 m/sece) Air outlet: Belowf) Air suction: Frontg) Noise Level: 50-60 DBe) Magnetic Sensor: Model No- 1L- AC-101Sf) The unit shall be provided with an easy mounting arrangement, comprising a flat mounting frame suitable for wall fixing using appropriate coach screws/ suitable arrangement as per site requirement." | — | — | — | 83,544 | |
| — | 9.00 | — | — | ||
| "Supply, installation, testing & commissioning of Air Curtains of Size 48" (4 Feet):a) Motor: Single phase 230 VAC, 0.25 HP, 1440 RPM, Class B insulationb) Dimension: 225mm x 230mm x 1200mmc) Impeller - Dia & length: Aluminium, 160mm x 500mm - 2 Nos. d) Velocity: 12-14 m/sece) Air outlet: Belowf) Air suction: Frontg) Noise Level: 50-60 DBe) Magnetic Sensor: Model No- 1L- AC-101Sf) The unit shall be provided with an easy mounting arrangement, comprising a flat mounting frame suitable for wall fixing using appropriate coach screws/ suitable arrangement as per site requirement." | — | — | — | 3,89,754 | |
| — | 3.00 | — | — | ||
| "Supply, installation, testing & commissioning of Air Curtains of Size 60" (5 Feet):a) Motor: Single phase 230 VAC, 0.33 HP, 1440 RPM, Class B insulationb) Dimension: 225mm x 230mm x 1500mmc) Impeller - Dia & length: Aluminium, 160mm x 650mm - 2 Nos. d) Velocity: 12-14 m/sece) Air outlet: Belowf) Air suction: Frontg) Noise Level: 50-60 DBe) Magnetic Sensor: Model No- 1L- AC-101Sf) The unit shall be provided with an easy mounting arrangement, comprising a flat mounting frame suitable for wall fixing using appropriate coach screws/ suitable arrangement as per site requirement." | — | — | — | 1,35,228 | |
| — | 20.00 | — | — | ||
| "Supply and fixing of door closers at AC ward's doors for arresting cooling loss and make a perfect enclosure: a) Door Closers: Pneumatically regulated for Light Doors up to 40 Kgs, conforming to IS 6343:1982.b) MAKE: AIDO, HETTICH, IPSA or equivalent suitable make." | — | — | — | 39,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
EL-Maint-4-344-WA-92026-2027.pdf
ATTACHMENT
GCC-April-2022.pdf
ATTACHMENT
GCCCorrectionSlipNo1ofACS-14-07-2022.pdf
ATTACHMENT
GCCApril2022CorrectionslipNo_2RBDtd13122022.pdf
ATTACHMENT
IRSGCC-2022-AdvanceCorrectionSlipNo.3.pdf
ATTACHMENT
GCCApril2022ACSlip4.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo_5.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf Advance Correction Slip No 11
ATTACHMENT
AnnexureVclarificationforonlinesubmissiondated14.05.2024.pdf
ATTACHMENT
BankGuaranteeFormat.pdf
ATTACHMENT
BidSecurityFormat.pdf
ATTACHMENT
E-PG16.6.26.pdf
ATTACHMENT
InsuranceSuretyBondforPerformanceSecurity.pdf
ATTACHMENT
NoRelativeFormatEmployeeofWesternRailway-Annexure-II.pdf
ATTACHMENT
NORETIREDRAILWAYEMPLOYEEGCC2022-Annexure-III.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .