Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹37.7 L+₹24,146.63 (0.64%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹38.8 L+₹1.3 L (3.51%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹40.3 L+₹2.8 L (7.57%)Rejected-Finance FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹41.4 L+₹4.0 L (10.6%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
1 Jun 2022, 6:00 pmClosed
GE NORTH PUNE
Garrison Engineer North General Cariappa Marg Camp Pune 411001
GE(N)P/T-10OF2022-2023WEL MAINTTOINTENAL ELECTOFOFFRS MDJCO/ORMD REPAIR/REPLOF FTL/ CFL TYPE LIGHT FITTG WITH NEW ENERGY SAVING LED LIGHT FITTG IN AFMSD 64 ASC DEPOT ZONGA SHIVNERI APSJCOSPLPRO KOHIMAKGSHANTI NIRMAN VIHAROFAGE E/MUNDER GE(N) PUNE
2022_MES_521821_1
GE (N) P/TOKEN- 10 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NORTH PUNE
Refer tender documents.
8 documents required · 8 mandatory
₹500
GE NORTH PUNE
₹88,000
Yes
24 Jun 2022
4 May 2022
3 Jun 2022
4 May 2022
1 Jun 2022
19 May 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fitting fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
(a) One light / fan controlled by one switch one way.
(b) One light point controlled by two 2 way switch.
(c) Socket outlet 05 Amp on same board.
(d) Socket outlet 05 Amp on independent board.
(e) One bell / buzzer point controlled by one bell push
All as per item No : 02 point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH Cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes 1.2 mm thick, 60 mm deep with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches, or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH Cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
(a) One ligh/Fant point controlled by one No one way switch
(b) One three pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(d) One bell / buzzer point controlled by one bell push
All as per item No 4 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board.
M & L in repair for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH Cable with multistranded copper conductor of size 4.0 Sq mm nominal area and drawn through PVC non metallic rigid PVC casing caping and its accessories including one run of PVC insulated 2.5 Sq mm (nominal area) multistranded copper conductor FRLSH Cable as earth wire and connected from DB to DB/ main board complete all as specified and as directed.(Note- Two runs of 4.0 Sqmm main cable, one run of 2.5Sqmm earth conductor and one run of PVC conduit will be measured as one unit)
All as per item No 6 but Submain wiring with 2 runs of 6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor.
All as per item No 6 but Submain wiring with 4 runs of 6 Sqmm size main cable and one run of 4 Sqmm size earth continuity conductor.
All as per item No 6 but Submain wiring with 4 runs of 10 Sqmm size main cable and two run of 10 Sqmm size earth continuity conductor.NOTE:- For Sr no 2 to 9 , Wires test certificates is required from OEM before commencement of contract
S&F modular switch 01 way 6 Amp , 01 module ISI marked complete
S&F modular switch 02 way 6 Amp , 01 module ISI marked complete
S&F modular switch 01 way 16 Amp , 01 module ISI marked complete
M&L for Modular bell push 6 amp 230 volt 50 hz AC supply one way, complete all as specified
S&F modular socket 6 Amp , 2 module ISI marked complete
S&F modular socket 6 / 16 Amp , 02 in 01 , 02 module ISI marked complete
S&F for modular step fan regulator 120 watt 2 module suitable for 230 Volt 50 Hz supply all as specified
Supply & fix CALL Bell ISI marked complete
S&F ceiling rose surface Bakelite 3 terminals 230V 50 Hz ISI marked.
S&F for Lamp holder, PVC/ Polycarbonate type with back plate suitable for batten fitting completes all as specified.
S&F for Switch piano; flush type single pole one way, and 6 amp complete ISI mark
S&F for Switch Socket combination multipurpose having provision for 2 in 1, 3 pin 5 amp piano flush type complete all as specified
S&F for Switch Socket combination multipurpose having provision for 2 in 1, 3 pin 5/15 amp piano flush type complete all as specified
Supply,installation,testing and commissioning of ceiling mount auto light occupancy, dual technology sensor,adjustable of delay timer, infra red and ultrasonic detection,Dia 8mm IP 20, 3 wire with neutral optimum distance between 2 sensors should be 6 Mtr, stand by consumption 0.8W, fixed directly to a false ceiling with mounting claws (included) or installed in a battibox depth 50 mm all as specified and directed. Note:- All necessary FRLSH copper wires to connect complete lights of office bldg/OR living/Messes etc are deemed to be included in the rates quoted above for motion sensors. Make : Legrand Cat no 48806
S & F in repair for LED 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. Make- Bajaj Cat Part No BCLSB 10 NW or its equivallent model in JAQUAR,HALONIX, HAVELLS, PHILIPS.
S & F for for wall/ceiling mounted LED batten tube 20 watts light fitting, 230 volts with out put of 2000 lumens with extruded aluminium housing with decorative end caps and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 20 watts complete all as specified and as directed. Make :- JAQUAR Cat part No LGLZ01X020XN or Halonix Cat part No LL20-281-XXX065-ALI/ PHILIPS
Supply and fix for energy saving new generation 10 watts LED bulk head fitting , 230 volts with connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor from ceiling rose to fitting complete all as specified and as directed. Make :- PHILIPS/JAQUAR Cat No.CWLL01V109XX 10W/Halonix
Supply & fix in repair decorative wall mounted energy saving 03 watt LED bedside light fitting flexible and adjustable to any direction with integeral electronic driver complete with all accessories Cat Part No 48042 of philips or equivalent in Havells/Bajaj/Crompton
S & F in Repair for Decorative wall mounted luminaire with opal glass with nickle finishing wall lamp with E27 lamp holder with and including LED bulb 10/11 watts complete all as specified and as directed. Make- Jaquar Cat part No - JNL-CHR-WLSL-55004E27 , HALONIX HLWB-05-E27 or its equivalent in Philips.
S & F in repair for recess mounted 2' x 2' luminaire to enhance the delight of occupants with comfortable experience through its classic design & glare free sift illumination square LED panel 43 watts, white powder coated CRCA housing with full window acrylic diffuser giving a complete full glow look, operating voltage 140 volts - 270 volts, AC, 50 Hz complete all as specified and as directed. Make- JAQUAR Ultima Ultra Cat Part No LULTU1S036XC or its equivalent in Havells/ Philips
S & F in Repair for LED down light recess mounted luminare, round type 15 watts with efficiency of 100 lumens per watt, sleek design aluminium housing polycarbonate diffuser white finish operating voltage 150 V-270 V AC, 50 Hz all as per Make- Philips Cat Part No DN172B LED9S-6500 PSU, jaquar nero plus LNRP01R012XN or Havells complete all as directed by Engineer- in-charge
S & F in Repair for LED downlight surface mounted luminare round type 12 watts with inbult driver and polycarbonate opal diffuser white finish operating voltage 230V AC, 50 Hz including taking down old unserviceable fitting complete all as directed Make :- Jaquar LNVE02R012SN , philips/ Havells
S & F in Repair for Energy saving new generation 40 watts LED gate post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 complete all as directed. Make :- CG LPTO-40-CDL (White Transparent Glass)/Philips/ Jaquar LGTP06x40xN
M & L for PCC (1:3:6) type C1(using 20 mm graded stone aggregate ) as in foundation of poles and similar works, filling mass concrete complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge.
M&L for cutting roads for laying of cable/pipe and making good road surface with PCC 1:2:4 type B-1 with 20 mm aggergate stone complete all as specified and directed by Engr-in-Charge
Supply and laying galvanised steel tubing, light grade, IS-1239 marked with all fittings (ISI marked) and laid in trenches / under roads / in drains / fixed to poles/wallswith required size flat iron clamp bolts, nuts and washers, pipes of the 100 mm bore sizes :-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Supply and laying 50mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed.
Supply, lay, joint, test and commissioning of LT under ground cable 1100 volt grade , XLPE insulated and PVC sheathed heavy duty armoured with aluminium conductor , IS 7098-I Marked, Laid in trenches/ducts/fixed on poles/walls/laid under roads/paths/drains/culverts or encased in GI pipe including cable glands, lugs jointing material etc complete including taking out old UNSV cable all as specified and directed. cable of the following size.
(a) 25 Sq mm 4 Core
(a) 50 Sq mm 3.5 Core
S&F LED street light fitting 15 Watt 230V energy efficient & environment friendly type. The fitting should have powder coated, pressure die cast Aluminium housing and heat resistant toughened glass with frame having better optics for uniform distribution complete all as per Make JAQUAR Cat No LSRTO1S016XC or equivalent of make Bajaj, Philips, Havells as approved.
S&F LED street light fitting 30 Watt 230V energy efficient & environment friendly type. The fitting should have powder coated, pressure die cast Aluminium housing and heat resistant toughened glass with frame having better optics for uniform distribution complete all as per Make JAQUAR Cat No LSRTO1S025XC or equivalent of make Bajaj, Philips,Havells as approved.
S&F in repair for MCB DB TPN 4 way double door sheet metal enclosure for 63 Amps MCB TPN incomer comprising of OEM/manufacturer specified bus bar, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall all as specified. MAKE:- LEGRAND/L&T/SCHNEIDER
S&F in repair for MCCB DB VTPN 4 way double door sheet metal enclosure for 100 Amps 4 pole MCCB (ICS = ICU= 100%) Incomer comprising OEM/manufacturer specified bus bar, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall all as specified. MAKE:- LEGRAND/SCHNEIDER
S&F in repair for MCCB DB VTPN 8 way double door sheet metal enclosure for 100 Amps 4 pole MCCB Incomer comprising OEM/manufacturer specified bus bar, 415 Volts, 50 Hz bus bar and neutral link complete including inserting in wall all as specified. MAKE:- LEGRAND/SCHNEIDER
S & F MCCB TPN 415 volts 25 KA suitable for fixing on DB of capacity 100 A (ICS=ICU=100%) with extended terminals complete all as specified.
S & F for MCB triple pole and neutral 415 Volts, 63 Amps, 10 KA. (ICS=ICU=100%)
S & F for MCB triple pole and neutral 415 Volts, 32Amps, 10 KA.(ICS=ICU=100%)
S&F in repair for MCB DB SPN 04 way double door sheet metal enclosure with OEM specified common bus bar and neutral link compete including inserting in wall all as specified. MAKE:- LEGRAND/SCHNEIDER
S&F in repair for MCB DB SPN 08 way double door sheet metal enclosure with OEM specified common bus bar and neutral link compete including inserting in wall all as specified. MAKE:- LEGRAND/SCHNEIDER
S&F in repair for MCB DB SPN 12 way double door sheet metal enclosure with OEM specified common bus bar and neutral link compete including inserting in wall all as specified. MAKE:- LEGRAND/SCHNEIDER
S & F for 'C' curve MCB single pole & neutral 240Volts 32/40 Amps.
S&F 'C' curve MCB SP 240 volt 6 to 30 Amp
Supply and fix MCB Protected SRCD box 4 module 25 Amps with surface mounted PVC enclosure SRCD(socket residual current device) single pole with a three pin socket & top complete with 25 Amps MCB single pole. Make: Havells Cat part No DHDTCSN0251020 OR Equivalent C&S/Indo Asian/L&T/Bajaj/Legrand
Supply and fix for sheet metal enclosures single pole and neutral with a three pin earth plug and socket complete with one MCB SP 20/ 32Amps complete all as specified and as directed.
S&F in repair readymade surface mounted Gang box/ PVC box with modular cover plate and frame all ISI marked suitable for holding modular switch socket & regulators for the following module:-
(a) 3 module
(b) 4 Module
(c) 6 Module
(d) 8 Module
S&F in repair surface mounted 20A & 10A modular switch Socket combination ( 4 fixing holes ) with PVC box all ISI marked complete all as specified
S&F in repair 32A DP modular switch W/O fuse with neon indicator ISI marked complete
S & F for casing and capping size 25 mm for existing wires including removal of old unserviceable one complete all as specified and as directed
Material and labour for attending emergent complaints i.e no light, earth leakage, short circuit, neutral break mains/ sub mains/ internal circuits of existing system of main building/ block, making continious electric supply including carrying out minor repairs etc as required to make the system in order/ functional including replacing fuse wire, copper cable, copper thimbles, glands, earthing wire complete all as specified and as directed. Note :- Rate of fuse wire, copper thimbles, glands, earthing wire are deemed to be considered in this item.
Taking down existing cable electrical /fiber/telephone of any type and any description/ size from wall/ roof/floor and refixing the same within PVC conduit pipe or casing capping and making good to the disturbed surfaces to match the existing complete all as specified and directed at site. Note : - Rates of PVC conduit pipe/ casing capping will be measured and paid separately under relavant iterms.
Supply and fix for casing and capping heavy duty, size 20mm with all fittings including removal of old unserviceable one complete all as specified and as directed
Supply and replace for rigit PVC conduit 20mm dia. heavy duty of white/ ivory colour with all accessories and making good the disturbed seurfaces for laying of telephone cable complete including removal old existing unserviceable all as directed
Supply and replace for single core cable PVC insulated and unsheathed multistranded copper conductor of following size from point wiring/Submain wiring including removal old existing unserviceable one complete all as specified and directed.
(a) 1.5 Sq mm
(b) 2.5 Sq mm
(c) 4.0 Sq mm
(d) 6.0 Sq mm
Disconnecting / taking out carefully old unserviceable LT Feeder pillar box and making good the disturbed surfaces including Supply, Installation, Testing & Commissioning Factory made 1Mtr x1.2 Mtr LT feeder pillar box {CPRI approved } 440V AC , Compartmentalized , in door type in 1.6 MM thick CRCA Sheet of Appropriate Size,IP65 Front Open Double Doors with sliding bolt locking arrangement, Dust & vermin proof, Cable Entry through Gland plates - Bottom only, Powder Coated , 3Phase HR Sleeved Colour Coded Aluminium Main Bus bar of 200 Amp , 03 No’s along with one Neutral Half Bus bar . Wiring with 10 Sq mm Copper wire ( FR ) , , Cable glands brass chromium plated of different sizes suitable for incoming MCCB' 125 Amp and fitted with following specified items:- ( Location : Block No : 108/109 kohima line )
(a) MCCB 4 POLE 415 Volt , 100 Amp , Thermal Release Range 25 KA (ICS=ICU=100%) , Make : Legrand /Schneider - 02 No
(b) MCB DP 40 Amp ,Breaking capacity10 KA -12 Nos Make : Lerand / Havells
(c) Digital type VAF + PF meters , 03 Phase with CT's complete, Make : Legrand / Havells / AE -1 No .
(d) Rotary switch - 01 No
(e) Indicator lamp Make : L&T / Legrand / Havells / AE - RYB - 1 Set
(f) . Space for Energy meter, digital type 1 X 240 Volts , single Phase , with optical port rating 10 to 60 amp , - 12 Each . Cat part no WM101BC7DDH of L&T
Supply and fix in repairJunction box IP 65 ready made type having Aluminium bus bar of capacity 60 Amps, box size 190x140x110 mm with connector and including bus bar (3 phase + 1 Neutral) 60 Amps and MCB SP 6 Amps 10 KA 240 volts with necessary connections and entry glands and fixed the box on poles by means of mild steel flat iron 25 mm X 4 mm thick cut to size made to shape and fixed on poles with suitable size of nut, bolts and washers complete all as specified and as directed by Engineer-in-Charge. Make: Hensel or Equivalant in Sintex.
Supply and fix ready made outdoor type heavy duty polymer earth pit chamber box of size 300x300x260 mm with provision of earthing strip/ GI pipe entry glands and cover complete all as specified and as directed by Engineer-in-Charge make JEAF techno earthing. (Note sample is kept in GE Ofiice sample room)
M&L for Maintenance Free Grounding Solution set earthing comprising of High tensile low carbon steel rod of 3 Mts length & 17.2 mm dia with 250micron ( average ) molecularly bonded copper on the outer surface along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Make: JEF Technology or equivalant in True power earthings Note:- a) Test certificate from the OEM has to be produced by the contractor for the material used in earthing. b) If the test result obtain from earthing is not less than 3 Ohms then earthing has to be done again at no extra cost. c) Rates for Excavation and earthwork in any type of soil/strata, testing on completion, GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from Electrode is deemed to be included in rate quoted.)
Supplying and fixing in repair 10Sq mm 2Core, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed in service connections one twin core cable flat or circular Make Havells, finolex
Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site.
anand enterprises
PURVA ELECTRICALS AND ENGINEERS
Chaulya Enterprises
Suchit constructions
RELIABLE ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .